• 제목/요약/키워드: Test evaluation

검색결과 15,249건 처리시간 0.04초

자동차 시트의 피로도 평가를 위한 근전도 평가를 위한 근전도 측정기의 사용 (The Use of Electromyography for Fatigue Evaluation of Automotive Seats)

  • 이영신;이의신;박세진
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1997년도 춘계학술대회논문집
    • /
    • pp.10-16
    • /
    • 1997
  • The ride comfort is one of the most important indices which decide the quality of automotive seats. A subjective evaluation is the general method for comfort evaluation of automotive seats. But the subjective evaluation assess the individual sensibility using questionnaire. Therefore, a need to develop methodologies to obtain objective measurements of the fatigue evaluation is evident. In an effort to monitor muscle activity during driving electromyography (EMG) was employed. In an experimental setting the subjective evaluation was conducted using questionnaire under the static conditions (8 subjects) and the fatigue was induced in muscles using EMG under the dynamic conditions (2 drivers). The resultant EMG signals were then sampled for three different muscles. In test involving 2 subjects of similar size and build, utilizing four different automotive seats, test results support the use of EMG to quantify muscular fatigue as a viable means of objective evaluation for the different automotive seats.

  • PDF

Test Plan for Anti-Jamming System Performance Evaluation

  • Park, Ji-Hee;Kwon, Seung Bok;Shin, Dong-Ho
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제4권1호
    • /
    • pp.17-23
    • /
    • 2015
  • With the increase in the risk of GPS jamming, the development and application of anti-jamming GPS techniques have been actively performed. As the objective performance verification of developed techniques is important, equipment development for verification and discussion on anti-jamming performance test method and procedure have also been conducted. However, most tests are related to the specification of equipment and therefore detailed procedure of the performance verification of an anti-jamming system needs to be developed. In this study, requirements for anti-jamming performance verification were described, and test configurations and performance evaluation items depending on three kinds of test methods (lab test, basic outdoor test, and chamber test) were suggested for anti-jamming performance verification.

자율실습교육에서 스마트폰 동영상을 활용한 자가평가 학습법이 간호술기 수행능력, 자율실습만족도, 학습동기에 미치는 효과: 유치도뇨를 중심으로 (Effects of Self-evaluation using Smartphone Recording on Nursing Students' Competency in Nursing Skills, Satisfaction, and Learning Motivations: Focusing on Foley Catheterization)

  • 장은화;박수현
    • 기본간호학회지
    • /
    • 제24권2호
    • /
    • pp.118-127
    • /
    • 2017
  • Purpose: The purpose of this study was to identify effects of self-evaluation using smartphone recording on competency in nursing skills, satisfaction and learning motivations in nursing students'. The setting was the open laboratory hours. Methods: A quasi-experimental pre/post-test design was conducted in September 2015. The participants were 82 sophomore nursing students from one University. The experimental group did self-evaluation by watching recorded video clips of their performance. The control group did not have any self-evaluation. The primary outcomes were scores from the foley catheterization checklist, scores from a student satisfaction tool, and scores from a learning motivation tool. Data were analyzed using ${\chi}^2$ test, Fisher's exact test, independent t-test, and paired t-test. Results: There was a significant higher mean score in levels of satisfaction by students in the experimental group compared to the control group (t=2.26, p=.027). In addition, improvement in communication skills by the experimental group was significantly higher than improvement in the control group (t=3.96, p<.001). Conclusion: Findings show that self-evaluation using smartphone recordings has positive effects on increasing both communication skills and satisfaction with practice during open laboratory hours. These results indicate that, self-evaluation using smartphone recording is useful as a supplement to traditional open laboratory education.

75톤급 추진기관 시험설비 화염유도로 냉각해석에 관한 수치적 연구 (A Computational Study on Cooling Analysis of the Flame Deflector for the 75 tonf Class Propulsion Test Facility)

  • 문성목;조남경;김성룡;전성복;이경훈;김동환
    • 한국추진공학회지
    • /
    • 제19권2호
    • /
    • pp.55-64
    • /
    • 2015
  • 본 연구에서는 75톤급 추진기관 시험설비 화염유도로 설계안에 대한 열적 안전성 및 연소가스의 안전한 배출을 평가하기 위하여 3차원 화염냉각해석을 수행하였다. 화염과 냉각수 간의 열전달 및 상변화 과정을 모사하기 위하여 Mixture 다상모델을 적용하였으며, 단일 화학종 비반응 플룸모델을 이용한 화염냉각해석을 수행하였다. 본 해석결과를 통하여 냉각수 유량에 따른 화염유도로 벽면에서의 최고 온도값을 예측하였으며, 또한 콘크리트 내화온도에 해당하는 최소 냉각수 유량을 도출하였다.

기계편용 장식사 니트소재의 물성 및 감성 평가 (Physical and Hand Properties of the Knitted Fabrics From Machine Knitting Fancy Yarns)

  • 박기윤;박명자
    • 한국의상디자인학회지
    • /
    • 제10권2호
    • /
    • pp.125-138
    • /
    • 2008
  • For physical and hand property evaluation of fabrics, the knitted fabrics from 11 types of machines knitting fancy yarns, boucle (M1), knot (M2), snarl (M3), and slub (M4), tamtam (M5), tubular (M6), fur 1 (M7), bead (M8), fur 2 (M9), fur 3 (M10), and ladder (M11) yarns, were prepared with 7-10 G plain stitch. Washing test and pilling test had also been carried out. For hand properties by objective sensibility evaluation, 17 items of sir mechanical properties using KES-FB (Kawabata Evaluation System) had been measured. Then hand values of knitted fabrics were calculated with a calculation formula, namely KN-402-KT. Finally the total hand values were obtained through KN-301-WINTER. As a result of physical properties and objective evaluation for machines knitting fancy fabrics, most of them shrank in the direction of wale and course after the washing test, in which their shrinkage rate had a maximum of 3.5%. Therefore, the washing test indicated that the shrinkage ratio of knitted fabrics had a minor change. The results of the pilling test are mostly 4-5th grade, and all of the machines knitting fancy fabrics showed good results in the pilling resistance. In hand properties and objective sensibility evaluation, twisted fancy yarns, such as boucle (M1), knot (M2), snarl (M3), and slub (M4), were superior to bonding rigidity (B) and shear rigidity (G). The surface property between course and wale differs in all samples and course direction is tougher than wale direction. FUKURAMI (fullness and softness) of all samples have high values, besides NUMERI (smoothness) of tamtam (M5) and boucle (M1), which were rather good. Most samples except fur 1 (M7) had low KOSHI (stiffness) value. The total hand value (THV) of twisted yarns was low. This study proves that manufacturers, who plan knitting yarn products and knit fashion, can apply these data to develop machines knitting yarns and knits that fit the consumers' demands.

  • PDF

위.장관계 수술 환자간호의 질평가를 위한 도구개발 (Development of an evaluation tool of quality of nursing care for gastrointestinal surgery patient)

  • 이병숙;박정호;조현
    • 한국의료질향상학회지
    • /
    • 제4권2호
    • /
    • pp.260-278
    • /
    • 1997
  • Background : Quality of professional nursing care is the most essential factor for survival and growth of nursing profession. Then, nursing professionals have responsibility for the evaluation of quality of professional nursing care. The purpose of this study was to develope an evaluation tool of nursing care for patients received gastrointestinal surgery with general anesthesia. This study was a primary work for the developement of a computer program for the evaluation of nursing care. Methods : This study was done through some consecutive steps. They were (1) Developement of items for the tool (2) Developement of an evaluation tool of nursing care quality for the G-I surgery patient (3) Test of reliability and validity of the tool. Two groups of experts and expert pannels who had much experience of the QA and the care of G-I surgery patients participated for developement of the items. 85 nursing records were used for the test of reliability and validity of the developed tool. The evaluation tools were developed with two types of scoring, norm-referenced tool and criterion-referenced tool. Results The system of items for tool was evaluation area evaluation item-indicator. There were 7evaluation areas which contained 32evaluation items which contained 7lindicators. Evaluation areas 1, 2, 3, 4 were for the evaluation of process and 5, 6, 7 were for the evaluation of outcome of nursing care for G-I surgery patient. For the test of interrator reliability, correlation coefficients of each scores of items and intragroup correlation coefficients were calculated. The average correlation coefficients between two rators were 0.65, 0.54 and the intragroup correlation coefficient were 0.99 and 1.00 by the types of scoring. The Cronbach alpha coefficients of the tools were 0.54 and 0.46 by the types of scoring. The average content validity index of the items was 0.95 from 4 pairs of experts. Because there were significant differences between some scores of quality of nursing care of 3 general hospitals regardless of the types of scoring, the tools could be thought to have some construct validity. And also, there were significant correlations between some scores of quality of nursing care and admission days and admission days after surgery regardless of the types of scoring, the tools could be thought to have predictive validity. Conclusion In this study, the evaluation tool of nursing care was developed for the very specified group of patient, G-I surgery patient. And the items were developed and tested by the experts of nursing practice. Because of these reasons, it was supposed that the tool could be used effectively in nursing pratice. And the procedures for the development and the test of the evaluation tool of nursing care in this study were supposed to be used for the developement of other tools.

  • PDF

SLAG 박리성 평가 방법에 대한 고찰 (A study on the evaluation method for slag detachability)

  • 우유철;김희진
    • Journal of Welding and Joining
    • /
    • 제5권1호
    • /
    • pp.57-63
    • /
    • 1987
  • A method which can be used for evaluating slag detachability is proposed in this study. The proposed method was intended to get an absolute value for slag detachability, to give consistent value for a given welded joint, and finally to be simple to test. With a test fig made in this study, an impact by dropping a steel ball (13Kg in weight) is applied on the back side of an as-welded plate having a slag layer on the weld bead. Such impact applied forces the slag to drop off from the bead surface. In order to make a quantitative evaluation the amount of slag removed was measured with increasing the number of drops. Using this method six kinds of fluxes were evaluated in terms of the effects of flux type, basicity and weding variables on the slag detachability. As an initial result of this test, it was found that welding heat input affects the detachability significantly. Most importantly the evaluation made using the presently proposed method gives the same order of ranking as that of the actual practice done by a welder.

  • PDF

Reliability Evaluation of an Oil Cooler for a High-Precision Machining Center

  • Lee, Seung-Woo;Han, Seung-Woo;Lee, Hu-Sang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권3호
    • /
    • pp.50-53
    • /
    • 2007
  • Improving the reliability or long-term dependability of a system requires a different approach from the previous emphasis on short-term concerns. The purpose of this paper is to present a reliability evaluation method for an oil cooler intended for high-precision machining centers. The oil cooler system in question is a cooling device that minimizes the deformation caused from the heat generated by driving devices. This system is used for machine tools and semiconductor equipment. We predicted the reliability of the system based on the failure rate database and conducted the reliability test using a test-bed to evaluate the life of the oil cooler. The results provided an indication of the reliability of the system in terms of the failure rate and the MTBF of the oil cooler system and its components, as well as a distribution of the failure mode. These results will help increase the reliability of oil cooler systems. The evaluation method can also be used to determine the reliability of other machinery products.

제동장치 스퀼소음의 특성 분석을 위한 시험평가시스템 개발 (Development of Testing Evaluation System far Analyzing Squeal Noise characteristic of the Brake System)

  • 박호;김동규;김흥섭
    • 한국공작기계학회논문집
    • /
    • 제10권6호
    • /
    • pp.21-28
    • /
    • 2001
  • Analysis of squeal noise generated during brake operation is an important task for the improvement of brake noise prob-lem. By the use of measuring instrument and techniques, test and evaluation process are to be developed systematically in quantitative analysis. The cost far test and evaluation 7an be reduced, and the technical power can be raised by the devel- oped system.

  • PDF

자동차 조립공정에 대한 작업자세 평가도구의 비교 (Comparison of Evaluation Tools of Work Posture in Automobiles Assembly Process)

  • 서승록
    • 대한인간공학회지
    • /
    • 제25권3호
    • /
    • pp.61-66
    • /
    • 2006
  • Awkward work postures in workshop highly affect on work-related musculoskeletal disorders(WMSDs). Especially, in automobiles assembly process, these awkward work postures of workers may cause serious injury and illness. This study is to compare the performance among the evaluation tools which can measure the work-loads caused by the awkward work postures in automobiles assemble process. RULA, REBA and TVAL(Toyota Verification of Assembly Line) are used as the evaluation tools. The 85 jobs selected in the automobiles assembly process are applied to the three tools and their performances are analyzed after the evaluation of the work-load in each job. Through various measures of performance such as statistical test, DUNCAN test, regression test etc., the tendencies and characteristics among them are analyzed in detail.