• 제목/요약/키워드: Test Temperature

검색결과 10,026건 처리시간 0.038초

소비자 조사와 착의 실험을 통한 온도감응형 기능성 의류개발을 위한 기초연구 (Thermo-sensitive Clothing Development by Consumer Investigation and Wearing Test)

  • 상정선;정경화;박주현;오경화
    • 한국의류산업학회지
    • /
    • 제19권1호
    • /
    • pp.90-100
    • /
    • 2017
  • In this research, consumer awareness investigation and wearing test were carried out for obtaining useful data on the development of thermo-sensitive functional clothing material. A survey involved 216 people in Seoul and Kyeonggi-do, and 200 questionnaires data were analyzed by descriptive statistics and frequency using SPSS 17.0. Four healthy men in twenties were participated for wearing test. Subjects in normal loungewear were exposed to temperature change from the initial temperature $30^{\circ}C$ down to $5^{\circ}C$ for an hour in a climate chamber. The environmental temperature, surface temperature of garment and skin were measured. As a result, most of respondents have all season clothing products such as underwear, hosiery, and jogging suit for loungewear. Also, thermo regulator y functional clothes are frequently used as underwear and sweat shirt. The consumer awareness investigation on thermo regulatory functional clothing showed that the most important key buying factor is quick climate temperature response, easy maintenance, design and cost, in that order. Surface temperature of garment went down with the cooling down of environmental temperature. The lower environmental temperature, the greater temperature difference by body part showed. Skin temperature change by environmental temperature showed similar tendency of garment surface temperature. In comparison between garment surface and body skin, temperature difference became larger under the lower environmental temperature.

온도보상형 전기저항 프로브의 현장 적용성 평가 (Application of Temperature-compensated Resistivity Probe in the Field)

  • 정순혁;윤형구;이종섭
    • 대한토목학회논문집
    • /
    • 제31권4C호
    • /
    • pp.117-125
    • /
    • 2011
  • 최근 신뢰성 높은 지반조사를 실시하기 위하여 국부적인 영역에서 해상도 높은 데이터의 획득이 가능한 전기비저항의 활용이 증가하고 있다. 본 연구의 목적은 온도 효과를 고려하여 보다 신뢰성 높은 전기비저항 값의 획득을 위한 현장용 온도 보상형 전기비저항 프로브의 개발 및 현장 적용성 평가이다. 프로브에 삽입된 온도센서는 온도전이 실험결과와 실험시 안정성 등을 고려하여 선단부로부터 15mm, 30mm, 그리고 90mm 지점에 부착하였고, 프로브 관입시 지반의 교란과 기하학적 형상을 고려하여 콘 형태로 제작하였으며 선단부의 각도는 $60^{\circ}$로 결정하였다. 현장실험에 사용되는 표준 콘과의 비교를 위하여 직경은 표준 콘과 동일한 35.7mm로 제작하였으며, 관입 속도도 동일하게 20mm/sec로 적용하였다. 관입 실험 시, 콘이 지반에 관입 되는 순간 약 $4^{\circ}C$의 온도 변화를 관찰하였으며 이를 보정하여 표준 콘에서 획득한 값과 비교하면 전기비저항을 이용한 지반조사시 반드시 온도에 대한 영향을 고려해야 함을 알 수 있었다. 본 연구에서는 현장용 온도보상형 전기비저항 프로브의 개발 및 현장검증을 통하여 관입 실험 시 온도 보정이 반드시 필요함을 보여준다.

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

  • Hyeongi Moon ;Sujong Yoon;Mauricio Tano-Retamale ;Aaron Epiney ;Minseop Song;Jae-Ho Jeong
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3874-3897
    • /
    • 2023
  • A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High-Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next-generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds-averaged Navier-Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.

대형디젤엔진 배출가스 저감을 위한 DPF의 재생특성 연구 (A Study on Characteristics of DPF for Heavy-duty Diesel Engine on Pollutant Emission Reduction)

  • 엄동섭;이승호;오상기
    • 동력기계공학회지
    • /
    • 제12권5호
    • /
    • pp.34-39
    • /
    • 2008
  • The combustion purpose of diesel engine is to reduce the emission of green gas and to produce high output. Generally, the regulation matter of emission gas is largely diveded by 'THC', 'NOx', 'CO' and 'PM'. Among those matters, the most problem is to disgorge into 'PM', the character of diesel combustion. Diesel PM can be controlled using Diesel Particulate Filter, which can effectively reduce the level of soot emissions to ambient background levels. $NO_2$ generated by the DOC is used to combust the carbon collected in the DPF at low temperature. To certificate DPF device that is suitable to domestic circumstances, it is necessary to exactly evaluate the DPF devices according to the regulation of DPF certificate test procedure fur retrofit. To do carry out the above-mentioned description the understanding of that regulation like the standard of PM reduction is needed. In this study the test procedure including test cycle and BPT test condition was examined, and also the test result for specific DPF was analyzed. In every test like field test, PM reduction efficiency test and Seoul-10 mode test, no defect was showed.

  • PDF

장기간 사용된 발전설비용 고온 스터드 암나사부 관리방법 (Managing method for stud female threads used long period under high temperature on the power plants)

  • 정남용;김문영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.199-205
    • /
    • 2000
  • The stud female threads for stud bolts tend to degrade faster by high temperature over 450 C. Therefore, inspection for replacement cycle of stud bolts is used to carry out many kinds of method such as ultrasonic test(UT), magnetic test(MT), wobble test, visual test and hardness test. The visual inspection among those has been only applied for stud female threads generally and wobble test is often used to apply stud bolts. In this paper, wobble test is applied for evaluation of stud female threads on the contrary stud bolts especially. It is also applied three types of inspection method included wobble test on the two sites which is used for each other different operation cycle and three kinds of acquisition data are compared with evaluation methods. From the results, we have studied the characteristic exchanging of integrity evaluation data distribution according to using time and proposed managing method for female thread of stud on the power plants.

  • PDF

고품질의 기온자료를 이용한 연.계절평균기온의 변화에 관한 연구 (Study for the Changes of Annual and Seasonal Mean Temperature Using Adjusted Temperature Data in the Republic of Korea)

  • 박창용;최영은
    • 대한지리학회지
    • /
    • 제46권1호
    • /
    • pp.20-35
    • /
    • 2011
  • 본 연구에서는 기온자료의 품질검정, 기준시계열 생산, 동질성 검증 및 보정에 대한 체계적인 단계를 제시하고, 이러한 과정을 통해 생산된 연 계절평균기온을 이용하여 보다 정확한 기온변화 경향을 파악하고자 하였다. 품질검정에 의한 오류 자료는 모두 내적 불일치성 검사에 의해 탐지되었다 본 연구에서 사용한 동질성 검증 방법은 관측지점의 이전(relocation) 시그널을 비교적 잘 추출하여 우리나라 기온자료 동질성 검증에 적합한 방법으로 판단된다 연 및 계절별 평균기온의 보정 이후가 보정 이전 보다 증가 규모가 커졌다. 이러한 동질성 검증 및 보정으로 생산된 고품질의 기온자료는 보다 정확한 기후변화 특성 및 경향 연구에 도움이 될 것이다.

Thermo-Mechanical Fatigue Analysis of Ribbon Wire/Ag Electrode Interfaces for PV Module

  • 박노창;홍원식;한창운;김동환
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.48.1-48.1
    • /
    • 2011
  • In this presentation, We monitored weather data, such as global irradiance, ambient temperature, temperature of PV module, relative humidity and windspeed for 2 years, for determining accelerated test condition. then, we determined the temperature limit of accelerated test through weather data and FEM analysis. Detailed procedures will be summarized in this work. After analysing outdoor stress such as thermal stress, we decided main failure modes and mechanisms of PV module, especially solder joint of ribbon wire. we carried out the measurement of material properties such as thermal expansion coefficient for planning of accelerated test. we designed accelerated test based on FEM analysis results. we carried out thermal cycling test with 1 cell mini module for 3 months. We monitored the change of electrical performance every 1 week such as Voc, Isc, Pmax, etc. and then, we analized the ribbon wire/electrode intefaces. Detailed results will be summarized in this work.

  • PDF

열상장비용 스터링 극저온 냉동기 특성평가 (III) : 열환경시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (III) : Thermal environmental test)

  • 김양훈;박성제;홍용주;김효봉;고득용;이승홍;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.163-166
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Linear drive Stilting cryocooler have matured to the stage of undergoing formal qualification test program The thermal environmental test of the Stilting cryocooler is presented in this paper. We performed that low and high temperature keeping test from -4$0^{\circ}C$ to +6$0^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity was determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooling performance of more than 0.8W@80K for 23$^{\circ}C$ ambient temperature with 40 $W_{ac}$ input power.

  • PDF

암모니아의 수평관내 단상 및 응축 열전달계수의 측정 (Measurement of Single Phase and Condensation Heat Transfer Coefficients of Ammonia in a Horizontal Tube)

  • 백영진;장영수;김영일
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.561-569
    • /
    • 2000
  • Single phase and condensation heat transfer characteristics of ammonia in a horizontal tube have been investigated experimentally The horizontal test section is composed of smooth SUS316 tube for refrigerant flow, surrounding annulus for water flow, and temperature and Pressure measuring sensors. For single phase test, subcooled ammonia mass flux was varied from 320 to 501 kg/mrs and temperature was varied from 18 to $47^{\circ}C$. For condensation test, mass flux and saturation temperature were varied from 86 to 128 kg/$m^2$s and 34 to $47^{\circ}C$, respectively. The equations of Gnielinski Soliman et al., Traviss et at., Cavallini and Zecchin, Shah, Chen et al., Tandon et al., and Chilli and Anand were compared with the experimental data. New correlations are proposed based on the experimental results and the absolute mean deviation of the experimental data becomes 1.0% for single phase test and 4.9% for condensation test.

  • PDF

침지시험법 및 전기화학적 분극법에 의한 2205 이상 스테인리스강의 임계공식온도 측정 비교 (Critical Pitting Temperature of 2205 Duplex Stainless Steels Using Immersion and Electrochemical Polarization Test Methods)

  • 신재호;이재봉
    • 한국표면공학회지
    • /
    • 제39권1호
    • /
    • pp.18-24
    • /
    • 2006
  • Although stainless steels have the excellent corrosion resistance by passive film, they are susceptible to pitting corrosion in the environment containing halogen elements such as chloride ions. The resistance to pitting corrosion can be evaluated by measuring the critical pitting temperature (CPT). CPT values can be obtained using immersion, potentiodynamic and potentiostatic polarization test methods. Results on duplex 2205 stainless steels showed that CPT values were measured as $50^{\circ}C,\;55^{\circ}C\;and\;61^{\circ}C$, respectively for immersion, potentiodynamic and potentiostatic polarization test methods, depending upon the different test methods, even though the difference between CPT values are not much.