• Title/Summary/Keyword: Test Setup Design

Search Result 76, Processing Time 0.023 seconds

Design of INS Simulated Equipment for Evaluation of Enhanced Jamming Resistance of INS-aided GPS Receivers (위성항법장치의 재밍대응 성능향상 검증을 위한 관성항법장치 모의 장치 설계)

  • Jung, Junwoo;Park, Sungyeol;Ahn, Byoung-Sun;Kang, Haeng-Ik;Kim, Kap Jin;Park, Youngbum
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.4
    • /
    • pp.339-346
    • /
    • 2017
  • We propose the design of an INS simulated equipment to evaluate the enhanced jamming resistance of an INS-aided GPS receiver with INS, when a jamming signal is injected into a simulated high dynamic platform. We propose the design of a relative cheap INS simulated equipment, instead of an expensive INS simulator connected to GPS simulators. Based on the design, we implement the equipment and setup high dynamic test environment using the equipment to evaluate an INS-aided GPS receiver. In the GPS L1 C/A and L2C simulations that inject jamming signals of the narrow and wide bandwidth into the GPS receiver with and without INS-aided algorithm, we obtain increased jamming resistance performance as +5 dB compared with the GPS receiver without INS-aided algorithm in all kinds of jamming bandwidth. Based on the simulations, we verified that the INS simulated equipment can be used to evaluate the enhanced jamming resistance of INS-aided GPS receivers.

Effects of the Complexity of 3D Modeling on the Acoustic Simulations and Auralized Sounds (3D 모델의 구체성이 건축음향 시뮬레이션 및 가청화시재에 미치는 영향)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.22-32
    • /
    • 2011
  • The present study examined the effects of the complexity of the 3D models on the results of acoustic simulation which is the predominant tool of the acoustical design of buildings. Also, the effects of the 3D model on the auralized sounds were investigated. In order to carry out the study, four 3D models with different levels of complexity were introduced for a real auditorium which have different numbers of surfaces in the persuit of the guidance of odeon room acoustic software. The set-up of models was also based on the level of transition order of the program. And the acoustic experiments were performed measuring room acoustic parameters including SPL, RT, C80, D50. Acoustic computer simulations were performed using four different models. Then, the results of the computer modeling were compared with the measured acoustical parameters. In addition, sound sources were recorded in the field and auralized sounds were made in convolution with the impulse source made from acoustic modeling. Then, subjective tests were undertaken using auralized sounds. As the results, it was found that the result of the acoustic simulation were closer to the real room acoustic properties when 3D model was more particularly made. For the subjective test, the listening materials were acknowledged as similar with the real sound source when more complex 3D model was used. Then, it could be concluded that the complexity of the 3D model affects the results of the acoustic modeling as well as subjective tests.

High-Temperature Structural-Analysis Model of Process Heat Exchanger for Helium Gas Loop (I) (헬륨가스루프 시험용 공정열교환기에 대한 고온구조해석 모델링 (I))

  • Song, Kee-Nam;Lee, Heong-Yeon;Kim, Yong-Wan;Hong, Seong-Duk;Park, Hong-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1241-1248
    • /
    • 2010
  • In large-scale production of hydrogen, a PHE (Process Heat Exchanger) is a key component because the heat required to carry out the Sulfur-Iodine chemical reaction that yields hydrogen is transferred from a VHTR (Very High Temperature Reactor) by the PHE. Korea Atomic Energy Research Institute established a helium gas loop for conducting performance test of components that are used in the VHTR. In this study, as a part of high-temperature structural-integrity evaluation of a designed PHE prototype that is scheduled to be tested in the helium gas loop, we carried out high-temperature structural-analysis modeling, thermal analysis, and thermal-expansion analysis for the designed PHE prototype. An appropriate constraint condition is proposed at the end of the in-flow and out-flow pipelines of the primary and secondary coolants and the proposed constraint condition will be applied to the design of the performance-test loop setup for the designed PHE prototype.

Analysis on the Shear Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel (L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 전단 거동 분석)

  • Yu, Sung-Yong;Ju, Ho-Seong;Ha, Soo-Kyoung
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.2
    • /
    • pp.105-117
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

Evaluation of thermal-hydro-mechanical behavior of bentonite buffer under heating-hydration condition at disposal hole (처분공 가열-수화 조건에서 벤토나이트 완충재의 열-수리-역학적 거동 특성 평가)

  • Yohan Cha;Changsoo Lee;Jin-Seop Kim;Minhyeong Lee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.2
    • /
    • pp.175-186
    • /
    • 2023
  • The buffer materials in disposal hole are exposed to the decay heat from spent nuclear fuels and groundwater inflow through adjacent rockmass. Since understanding of thermal-hydro-mechanical-chemical (T-H-M-C) interaction in buffer material is crucial for predicting their long-term performance and safety of disposal repository, it is necessary to investigate the heating-hydration characteristics and consequent T-H-M-C behavior of the buffer materials under disposal conditions considering geochemical factors. In response, the Korea Atomic Energy Research Institute developed a laboratory-scale 'Lab.THMC' experiment system, which characterizes the T-H-M behavior of buffer materials under different geochemical conditions by analyzing heating-hydration process and stress changes. This technical report introduces the detail design of the Lab.THMC system, summarizes preliminary experimental results, and outlines future research plans.

Analysis on the Shear Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel (U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 전단 거동 분석)

  • Ha, Soo-Kyoung;Son, Guk-Won;Yu, Sung-Yong;Ju, Ho-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.18-28
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of U-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D, agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.