• Title/Summary/Keyword: Test Plant

Search Result 3,804, Processing Time 0.037 seconds

Antimicrobial Activity and Safety Test of Mixed Plant Extracts Including Phellodendron Amurense and Eucommia Ulmides Oliv (황벽나무, 두충나무 등을 포함하는 복합수목추출물의 항균활성 및 안전성 시험)

  • Kim, Hyunwoo;Shin, Hyejin;Hwang, Danbi;Lee, Jieun;Bak, Manchun;Kim, Jinhong;Kim, Donguk
    • Korean Chemical Engineering Research
    • /
    • v.51 no.5
    • /
    • pp.536-539
    • /
    • 2013
  • In this study, mixed plant extracts including Phellodendro namurense and Eucommia ulmides Oliv were tested for antimicrobial activity and safety. Antimicrobial activity was measured by disc diffusion method using normal skin flora and opportunistic microbes such as Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli and Candida albicans. As safety test, single dose oral toxicity test, single dose inhalation toxicity test and repeat dose inhalation toxicity test were done. From antimicrobial test, plant extracts showed significant antimicrobial activity Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans, however, did not indicate any antibacterial effect on Escherichia coli. From 3 kinds of safety tests, toxicity of mixed plant extracts was not observed. From experimental results, mixed plant extracts including Phellodendro namurense and Eucommia ulmides Oliv showed good potential for natural antimicrobial agent.

Turbopump+Gas generator Startup Simulation Cold Flow Test (터보펌프+가스발생기 연계시험기 시동모사 수류시험)

  • Kim, Seung-Han;Nam, Chang-Ho;Kim, Cheul-Woong;Moon, Yoon-Wan;Seol, Woo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.19-25
    • /
    • 2009
  • This paper includes test results of 30tonf-level TP+GG startup simulation cold flow test using liquid oxygen and kerosene. Test objectives, coupled test plant configuration, test condition, test procedure of performed tests, and test results are presented.

  • PDF

Plant Assay에 의한 비소오염 토양평가

  • 안윤주;이주영;임승윤;정지영;정혜원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.198-200
    • /
    • 2004
  • Four crop plant species were tested to assess an ecotoxicity in arsenic-amended soils. Test plants were Sorghum bicolor, Cucumis sativus, Triticum aestivum, and Phaseolus radiatus. The presence of arsenic decreased the root and shoot growths. Arsenite was more toxic than arsenate to all test plants. Root growths of Phaseolus radiatus and Cucumis sativus seem to be a good protocol to assess ecotoxicity of soils contaminted by arsenic.

  • PDF

Development of a radiation thermometer for the adaptive steel plant (제철소 적응형 복사온도계 개발)

  • Park, Sang-Gug
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.173-178
    • /
    • 2002
  • In this research, we have worked about the radiation thermometer which can be applied to the hazard circumstance such as steel plant. In the results, we have developed radiation thermometer of a measuring range $500-1500^{\circ}C$, accuracy ${\pm}0.1%$, repeatability ${\pm}0.1%$, resolution $0.2^{\circ}C$. We performed extensive field test for 6 months at the hot strip mill in steel plant. Through the test, we have confirmed the reliability of the developed pyrometer.

  • PDF

A Full Scale Fossil Power Plant Simulator For Hadong (하동 화력 발전소 전범위 시뮬레이터 개발)

  • 김성호;김종현;조창호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.204-204
    • /
    • 2000
  • This paper describes the development of training simulator for Hadong fossil Power Plant. The simulator was developed to train operator, test new control Logic and evaluate alternative operating procedure for expert engineer of control system. The most control logics such as Siemens TELEPERM ME and GE Mark V are translated directly from microprocessors. Those HMI are also directly emulated. The simulation was performed by ProTRAX modeling software. The paper discusses the configuration of simulator and the simulation results of 30%, 50%, 75% and 100% normal rate load test.

  • PDF

Cyclic Test of welding connections for Steel-Plate Concrete Column to H-shaped Steel Girders (강판 콘크리트(SC) 기둥과 H형강 보의 용접 접합부에 대한 반복 이력 실험)

  • Park, Ho Young;Kang, Cheol Kyu;Choi, Byong Jeong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.63-71
    • /
    • 2014
  • This study presents an experimental study of the structural behavior for steel plate-concrete column-to-steel girder connections. Experiments were carried out to investigate the moment-rotation characteristics, failure behavior and ultimate moment capacity of these connections. The results of this experimental study involving three welded moment-resisting connections subjected to cyclic loading are presented. The specimens were fabricated at full scale to evaluate their hysteretic behavior. A description of the test specimens, the details of the joint, the test system and the testing methods are described. The test results showed that the structural behavior of these composite connections was influenced by the connection details.

Evaluation of Load Rejection to House Load Test at 100% Power for YGN 4

  • Sohn, Jong-Joo;Jeong, Won-Sang;Chi, Sung-Goo;Seo, Jong-Tae;Kim, Si-Hwan
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.588-595
    • /
    • 1995
  • The Load Rejection to House Load test at 100% power was successfully performed during the YGN 4 PAT period. In this test, all plant control systems automatically controlled the plant from 100% power to house load operation mode. The LTC code, which was used in the performance analysis during the design process of YGN 3&4, predictions of the test agreed with the measured data demonstrating the validity of the code as well as the completeness of the plant design.

  • PDF

Evaluation of Load Rejection to House Load Test at 50% Power for UCN 3

  • Lee, Chang-Gyun;Suk whun Sohn;Sohn, Jong-Joo;Seo, Jong-Tae;Lee, Sang-Keun;Kim, Youngsung;Nam, Kyu-Won;Jung, Yang-Mook;Chae, Kyeong-Sik
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.398-403
    • /
    • 1998
  • The Load Rejection to House Load test at 50% power was successfully peformed during the UCN 3 PAT period. In this test, all plant control systems automatically controlled the plant from 50% power to house load operation mode. The KISPAC code, which was used in the performance analysis during the design process of UCN 3&4, predictions of the test agreed with the measured data demonstrating the validity of the code as well as the completeness of the plant design.

  • PDF

A simulation test of lone rejection for steam turbine generator in nuclear power plant (원자력발전소 증기터빈 발전기의 부하차단 모의시험)

  • Choi, In-Kyu;Jeong, Tae-Woon;Lee, Ki-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2301-2303
    • /
    • 2003
  • A steam turnine in thermal/nuclear power plant drives generator and maintains it at rated speed using high temperature and high pressure steam energy. After synchronization in parallel with the power system, generator output increases according as the governor, that is the controller, increases steam flow into turbine. By the way, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is to limit the speed to its overspeed trip setpoint by stopping the steam flow as soon as possible, the test of which is called load rejection test. It is introduced in this paper for a simulation test of generator load rejection to be implemented on the turbine governor in a 600MW nuclear power plant before its startup.

  • PDF

A Simulation Test of Load Rejection for Steam Turbine Generator in a 680MW Nuclear Power Plant (680MW 원자력발전소 증기터빈 발전기의 부하차단 모의시험)

  • Choi, In-Kyu;Jeong, Chang-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1605-1606
    • /
    • 2007
  • An electrical generator in power plant is driven and maintained its speed at rated by steam turbine. By the way, after synchronization in parallel with the power system, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is to limit the speed to its overspeed trip set point by stopping the steam flow as soon as possible, the test of which is called load rejection test. It is introduced in this paper for a field simulation test of generator load rejection to be implemented on the turbine governor in a 680MW nuclear power plant before its startup.

  • PDF