• Title/Summary/Keyword: Test Monitoring & Control Process

Search Result 87, Processing Time 0.032 seconds

Adaptive Compensation Control of Vehicle Automatic Transmissions for Smooth Shift Transients Based on Intelligent Supervisor

  • Kim, Deok-Ho;Han, Jin-O;Sin, Byeong-Gwan;Lee, Gyu-Il
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.11
    • /
    • pp.1472-1481
    • /
    • 2001
  • In this paper, an advanced shift controller that supervises the shift transients with adaptive compensation is presented. Modern shift control systems for vehicle automatic transmission are designe d to provide smooth transients for passengers' comfort and better component durability. In the conventional methods, lots of testing and calibration works have been done to tune gains of the controller, but it does not assure optimum shift quality at all times owing to system variations often caused by uncertainties in shifting hydraulic systems and external disturbances. In the proposed control scheme, an adaptive compensation controller with intelligent supervisor is implemented to achieve improved shift quality over the system variations. The control input pattern which generates clutch pressure commands in hydraulic actuating systems, is updated through a learning process to adjust for each subsequent shift based on continuous monitoring of shifting performance and environmental changes. The proposed algorithm is implemented and evaluated on the experimental test setup. Results from the experimental studies for several operation modes show both improved performance and adaptability of the proposed shift controller to uncertain changes of the shifting environment in vehicle power transmission systems.

  • PDF

Design and Implementation Testbed of Home Network based PLC (PLC 기반의 홈 네트워크 테스트베드 설졔 및 구현)

  • Kim, Hyeock-Jin;Han, Kuy-Ban;Jean, Byoung-Chan
    • Journal of the Korea Computer Industry Society
    • /
    • v.10 no.4
    • /
    • pp.143-150
    • /
    • 2009
  • Remote control service, monitoring, gear service of information electronic appliance, various services of security service and so on of Home network that is by link of Ubiquitous environment are offered. These services need verification process through priority test to use and are changed. If test using actuality information electronic device for test, much expenses and time may be invested. Home network test bed offers softness of research using control model and simulator, in this paper, Wish to design and embody home network test bed to do environment construction of home network and test of application service. Because use istent power line just as it is without necessity to establish circuit in addition by solution of home network testbed, expense costs to be less and establishment used easy PLC. Also, propriated Wireless sensor network that use Zigbee by solution of home network testbed. Appliance check and monitor square do by Home Auto that know embodied, and embodied by Home Gateway that interlink terminals of Home Auto and out of.

  • PDF

Drug Use Evaluation of Vancomycin in Pediatric Patients (II) -The effect of Approval for Vancomycin Use (소아환자의 Vancomycin에 대한 약물사용 평가 (II) -제한항균제로 사용규제 강화 후의 효과)

  • Lee, Jeongmin;Lee, Soonsil;Kim, Youngjoo;Shin, Wan Gyoon;Lee, Byung Koo;Lee, Hoan-Jong
    • Quality Improvement in Health Care
    • /
    • v.1 no.1
    • /
    • pp.32-43
    • /
    • 1994
  • The 'Pharmacy and Therapeutic Committee' decided to restrict the use of vancomycin which was categorized into restricted antimicrobials, among general, reserved and restricted antimicrobials. The committee also established prescribing guidelines of vancomycin in Seoul National University Hospital, May, 1991. Especially, the restricted antimicrobials should be used after approval by infectious disease specialist physician. A retrospective drug use evaluation (DUE) on vancomycin has been conducted to compare with the previous vancomycin DUE study in 1990. 'Criteria for DUE on vancomycin' was modified from Am J Hosp Pharm. Total 65 charts of patients were retrospectively reviewed from July 1991 to June 1992 in Seoul National University Children's Hospital. The justification of use was improved from 56% to 75% comparing with the previous study. In analyzing process indicators, several criteria including body temperature monitoring, WBC monitoring and use of concomitant antibiotics were well documented, but serum creatinine monitoring, culture and sensitivity test and level monitoring were infrequently performed, while the accepted level has been improved. Accepted level for appropriate initial dosage and duration of therapy were decreased. In outcome analysis, blood culture after discontinuing the drug was relatively well documented compared with the previous study. As the results, the approval vancomycin use was shown to be effective and rational in antibiotic therapy. And it is suggested that the above findings should be communicated to the medical staff, and a active intervention, such as feedback control, also be necessary for rational drug use.

  • PDF

Qualification Test of ROCSAT -2 Image Processing System

  • Liu, Cynthia;Lin, Po-Ting;Chen, Hong-Yu;Lee, Yong-Yao;Kao, Ricky;Wu, An-Ming
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1197-1199
    • /
    • 2003
  • ROCSAT-2 mission is to daily image over Taiwan and the surrounding area for disaster monitoring, land use, and ocean surveillance during the 5-year mission lifetime. The satellite will be launched in December 2003 into its mission orbit, which is selected as a 14 rev/day repetitive Sun-synchronous orbit descending over (120 deg E, 24 deg N) and 9:45 a.m. over the equator with the minimum eccentricity. National Space Program Office (NSPO) is developing a ROCSAT-2 Image Processing System (IPS), which aims to provide real-time high quality image data for ROCSAT-2 mission. A simulated ROCSAT-2 image, based on Level 1B QuickBird Data, is generated for IPS verification. The test image is comprised of one panchromatic data and four multispectral data. The qualification process consists of four procedures: (a) QuickBird image processing, (b) generation of simulated ROCSAT-2 image in Generic Raw Level Data (GERALD) format, (c) ROCSAT-2 image processing, and (d) geometric error analysis. QuickBird standard photogrammetric parameters of a camera that models the imaging and optical system is used to calculate the latitude and longitude of each line and sample. The backward (inverse model) approach is applied to find the relationship between geodetic coordinate system (latitude, longitude) and image coordinate system (line, sample). The bilinear resampling method is used to generate the test image. Ground control points are used to evaluate the error for data processing. The data processing contains various coordinate system transformations using attitude quaternion and orbit elements. Through the qualification test process, it is verified that the IPS is capable of handling high-resolution image data with the accuracy of Level 2 processing within 500 m.

  • PDF

Numerical and Experimental Analyses of a Hot-Wire Gas Flowmeter

  • Kim, Byoung-Chul;Joung, Ok-Jin;Kim, Young-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1201-1206
    • /
    • 2003
  • A measurement device for gas flow rate using hot-wire module is developed for the utilization in low-accuracy industrial applications. The module has three wires of measuring and heating, and a bridge circuit is installed to detect electric current through the wire in the module. An amplification of the signal and conversion to digital output are conducted for the online measurement with a personal computer. In addition, temperature distribution in the module is numerically analyzed to examine the measured outcome from the module experiment. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. The experimental relation of measurement and flow agrees with the prediction from the numerical analysis. The outcome of the performance test indicates that the accuracy and reproducibility of the module is satisfactory for the purpose of industrial applications.

  • PDF

Automatic Sweep Flattening for Wavelength Sweeping Laser of SS-OCT (SS-OCT용 파장 스위핑 레이저를 위한 자동 스위프 평탄화)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • In this paper, the automatic sweep flattening for wavelength swept laser of SS-OCT has implemented. Through its performance test applied to the laser, 50 nm flat sweeping range, ${\pm}0.5dB$ fluctuation range, 22 sec the time required, and 10 mW average optical power were obtained. This shows that the realized automatic process can replace the inconvenient manual operation used for polarization control of current sweeping laser. Additionally it cuts costs for optical spectrum analyzer necessary to sweep monitoring.

Thermal Shock Behavior of Barium Titanate Ceramics

  • Jae Yeon Kim;Young Wook Kim;Kyeong Sik Cho;June Gunn Lee
    • The Korean Journal of Ceramics
    • /
    • v.3 no.3
    • /
    • pp.195-198
    • /
    • 1997
  • Post-firing process of electronic ceramic, such as electroding and encapsultion with resin, often causes damage by thermal shock. The thermal shock behavior of $BaTiO_3$ ceramics was investigated by the down-quench test, where the relative strength retained is determined after the sample is quenched from an elevated temperature into a fixed temperature bath. The critical temperature drop, $\DeltaTc$, was evaluated for three kinds of sintered $BaTiO_3$ ceramics, which were formed by extrustioin, uniaxial pressing using granules, and uniaxial pressing using powders. A drastic loss in strength caused by microcracking was observed for the specimens quenched with $\DeltaT\geq150^{\circ}C$. This concentp can be adopted as a method of the quality control by monitoring the sudden drop of the strength of capacitor products after each exposure to heat.

  • PDF

Development of Implantable Blood Pressure Sensor Using Quartz Wafer Direct Bonding and Ultrafast Laser Cutting (Quatrz 웨이퍼의 직접접합과 극초단 레이저 가공을 이용한 체내 이식형 혈압센서 개발)

  • Kim, Sung-Il;Kim, Eung-Bo;So, Sang-kyun;Choi, Jiyeon;Joung, Yeun-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.168-177
    • /
    • 2016
  • In this paper we present an implantable pressure sensor to measure real-time blood pressure by monitoring mechanical movement of artery. Sensor is composed of inductors (L) and capacitors (C) which are formed by microfabrication and direct bonding on two biocompatible substrates (quartz). When electrical potential is applied to the sensor, the inductors and capacitors generates a LC resonance circuit and produce characteristic resonant frequencies. Real-time variation of the resonant frequency is monitored by an external measurement system using inductive coupling. Structural and electrical simulation was performed by Computer Aided Engineering (CAE) programs, ANSYS and HFSS, to optimize geometry of sensor. Ultrafast laser (femto-second) cutting and MEMS process were executed as sensor fabrication methods with consideration of brittleness of the substrate and small radial artery size. After whole fabrication processes, we got sensors of $3mm{\times}15mm{\times}0.5mm$. Resonant frequency of the sensor was around 90 MHz at atmosphere (760 mmHg), and the sensor has good linearity without any hysteresis. Longterm (5 years) stability of the sensor was verified by thermal acceleration testing with Arrhenius model. Moreover, in-vitro cytotoxicity test was done to show biocompatiblity of the sensor and validation of real-time blood pressure measurement was verified with animal test by implant of the sensor. By integration with development of external interrogation system, the proposed sensor system will be a promising method to measure real-time blood pressure.

A Study on Microbiological Critical Limit in Sterilization processing of Fried Kimchi Soup (볶음김치스프 제조공정중 살균공정에 대한 미생물학적 한계기준에 관한 연구)

  • Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4018-4024
    • /
    • 2012
  • The purpose of this study was to application in the HACCP(Hazard Analysis Critical control) system of fried kimchi soup. The establishment of Critical limit during sterilization processing was measured by sterilization temperature, sterilization time, sensory test, storage test and pH change in storage for 30 days (May 1~30, 2012). Before sterilization, general bacteria, coliform and thermophile bacteria were detected to be $6.00{\times}10^5\;CFU/m{\ell}$, $7.50{\times}10^2\;CFU/m{\ell}$ and $2.75{\times}10^2\;CFU/m{\ell}$, respectively. In contrast, all microbial was not detected after sterilization($90{\pm}5^{\circ}C$, $22{\pm}5$ mins). The sensory test was decided as the most delicious kimchi according to $90{\pm}5^{\circ}C$, $22{\pm}5min$. In conclusion, the sterilization process of fried kimchi soup would be a great alternative to prevention, decreasing and removing of harmful microorganism, such as general bacteria, coliform and thermoduric bacteria etc. Therefore, the critical limit of sterilization temperature and time for quality control and biosafety was established at $90{\pm}5^{\circ}C$, $22{\pm}5$ mins. And it suggested that HACCP plan was necessary for monitoring method, monitoring cycle, problem solving method, education, training and record management during sterilization processing.

Utilizing Software-Defined Radio, Reception Test of AIS Payload Used in a Cube-Satellite (소프트웨어 정의 라디오를 활용한 초소형위성용 선박정보수집장치의 수신시험)

  • Kim, Shin-Hyung;Lee, Chang-Hyun;Kim, Gun-Woo;Cho, Dong-Hyun
    • Journal of Space Technology and Applications
    • /
    • v.2 no.2
    • /
    • pp.121-136
    • /
    • 2022
  • Automatic Identification System used in ship communication is required for marine control way, including monitoring of vessel operation in coastal and exchanging of information for safety navigation between them. But, it uses a very high frequency band of approximately 160 MHz, and at the same time, due to the curvature of Earth, there is a limit to the communication distance. Several demonstrations were made successfully over satellite, but not much work has been done yet through cube-satellite which has low-orbit at 500 km altitude. Here, we demonstrate a reception test of AIS (automatic identification system) receiver for a cube-satellites using software-defined radio (SDR). We collected AIS data from ship at port of Busan, Korea, using R8202T2 SDR and established to transmit them using Adam-Pluto and Matlab Simulink. The process of weakening the signal strength to a satellite was constructed using attenuator. Through above process, we demonstrated whether AIS data was successfully received from the AIS payload.