• Title/Summary/Keyword: Test Device

Search Result 3,559, Processing Time 0.029 seconds

A Study on the Standard of Test Method for Estimation of Usage Environment Safety and Performance of U-health Medical Device (유헬스케어의료기기의 사용환경 안전성 및 성능평가를 위한 표준시험방법 연구)

  • Park, S.K.;Cha, J.H.;Hur, C.H.;Park, K.J.;Moon, I.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.9-14
    • /
    • 2010
  • According to graying of population and income enlargement of people, interest about U-Healthcare of new form fusing with IT technology are enlarged. Need a estimation technology and standard of test method for safety and performance considering usage environment of U-Healthcare medical device. In this research, developed the standard of test method for usage environment safety and performance of U-Healthcare medical device referring IEC standards and KS standards.

Performance Tests and Development of the Cyclic Load Device Using a Bellows (벨로우즈를 이용한 반복 하중부과장치의 개발 및 성능시험)

  • Choi, Myoung-Hwan;Cho, Man-Soon;Park, Sung-Jae;Kim, Bong-Goo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.9
    • /
    • pp.903-909
    • /
    • 2007
  • A fatigue capsule is one of the special capsules to investigate the fatigue characteristics of the nuclear materials during an irradiation test in a research reactor, HANARO. In this study, the performance test and the preliminary fatigue test results by using a cyclic load device newly developed for a fatigue capsule are described. In order to obtain the characteristics such as a realization and a controllability of the periodic wave shape and the relationship between the pressure and the load, a spring and rigid bar specimens are used. The fatigue test for the 316L stainless steel specimen with 1.8mm in diameter and 12.5mm in gage length is also performed under the same conditions as the temperature($550^{\circ}C$) of the specimen during irradiation tests. As a result of the test, the fracture of the specimen occurs at a total of 70,120 cycles(about 12 days), and the displacement in this case is 2.02 mm. It is expected that these results will be used for determining test conditions and a comparison of the in-pile fatigue test results.

The Effect of a Self-exercise with Ankle Movement Control Device through Visual Feedback on Ankle Movement and Balance Ability for the Elderly: Case-study (시각적 피드백에 따른 발목 움직임 조절 도구를 이용한 자가 운동이 노인의 발목 움직임 조절과 균형 능력에 미치는 영향: 사례 연구)

  • Cho, Sun Young;Shin, Su Jung
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.3 no.2
    • /
    • pp.25-32
    • /
    • 2013
  • Objective : The purpose of this study was to investigate the effect of the ankle movement and the balance when the elderly conducted self-exercise with ankle movement control device through visual feedback. Method : This case-study included pre-test and post-test. The elderly women aged 80 did self-exercise for 20 minutes both morning and afternoon every day. The pre-test and post-test was conducted tracking test for evaluating ankle control movement and running time measurement of standing on one foot and Timed up-And-Go test for balance. Result : The subject improved the ankle control movement on tracking test and improved the balance in running time measurement of standing on one foot. But, Timed up-And-Go test was no change. Conclusion : The self-exercise with device of ankle movement control through visual feedback improved the ankle control movement and the balance for elderly.

  • PDF

Development with multi-layer passivation films for OLED with longer life time

  • Jung, Jae-Hoon;Lim, Jong-Sun;Rhee, Jung-Soo;Kim, Hoon;Lee, Sang-Pil;Kim, Nam-Deog;Ju, Byeong-Kwon;Lee, Joo-Won;Chung, Kyu-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.684-687
    • /
    • 2004
  • We have developed multi-layer passivation films of UV-polymerized film/inorganic composite film to improve the long lifetime of passivated OLEDs for very thin flat panel applications. Preliminary lifetime to half initial luminance ($L_{o}{\sim}\;3,000\;cd/m^2$) of order 300 Hr is achieved on the conventional encapsulated test pixel using a passive matrix drive at room temperature; 570 Hr lifetime is achieved on a de tested multi-layer passivated 9$mm^2$ test pixel.

  • PDF

Development of Micro-Ceramic Heater for Medical Application (의료용 소형 세라믹스 히터 소자의 개발)

  • Lee, Seung-Min;Lee, Kwang-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.219-229
    • /
    • 2022
  • In this study, we propose a miniaturized micro-ceramic heater device. After screen-printing a silver paste between pre-sintered two aluminum oxide plates to integrate a heating circuit, the device was fabricated through a low-temperature sintering process. In order to configure the optimal heating circuit integration condition, the output current evaluation and heating test were performed according to the number of screen prints of the silver paste at various voltages. A silver paste-based heating circuit printed with a line width of 200 ㎛ and a thickness of 60 ㎛ was successfully integrated on a pre-sintered alumina substrate through a low-temperature sintering process. In the case of the 5 times printed device, the thermal response showed a response rate of 18.19 ℃/sec. To demonstrate feasibility of the proposed device in the medical field, such as bio-tissue suturing and hemostasis, a voltage was applied to pig tissue in the device to test tissue change due to heat generated from the device. These results show the possibility that the proposed small ceramic heater could be used in the medical field based on its excellent temperature response.

A Study on the Ultra-Small Pendulum Generator Applicable to Wearable IT Device (웨어러블 IT 기기에 적용 가능한 초소형 진자 발전기에 관한 연구)

  • Jee, In-Ho;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.3
    • /
    • pp.139-143
    • /
    • 2022
  • In this study, Among the electromagnetic induction power generation (EMG) techniques, the design specifications of the RFPM were set, and a suitable test prototype was manufactured through finite element analysis (FEM, 2D) required for characteristic calculation. In addition, a dedicated testing device (Dynamo-Tester) was designed and manufactured to measure and analyze the test prototype. The test product was measured with a test device and the result is analyzed to suggest a method that can be applied by generating as much output power as possible to charge the battery of the wearable IT device using actual kinetic energy of the human body. As a result of the test, the output power was 1.679W and the efficiency was 79.31% under the conditions of rotation speed of 780.9rpm, torque of 0.264kgf/cm, and load current of 73.6~73.9mA. Therefore, it was analyzed that it was possible to charge the wearable device with the output of the ultra-small RFPM pendulum generator.

Effects of Eye Protective Device and Ear Protective Device Application on Sleep Disorder with Coronary Disease Patients in CCU (수면안대와 귀마개 적용이 중환자실 관상동맥질환자의 수면양상에 미치는 효과)

  • Koo, Yoon-Jung;Koh, Hyo-Jung
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.4
    • /
    • pp.582-592
    • /
    • 2008
  • Purpose: The purpose of this research was to analyze the effects of an eye protective device and ear protective device application on sleep disorder with coronary disease patients in CCU. Methods: The research design was set up as a nonequivalent control group non-synchronized design. The subjects were coronary disease patients in the CCU of a tertiary hospital. The subjects were composed of 20 in the group with an eye protective device, 18 in the group with an ear protective device, 17 in the group with an eye protective device and ear protective device and 20 in the control group. The data was analyzed by $X^2-test$, ANOVA, Repeated measures ANOVA, Sheffe-test, Simple main effect and Time contrast using SPSS Win 12.0. Results: The hypothesis, 'There are significant differences in sleep quantity among the four groups' was supported (F=1,342.71, p=.000). The hypothesis, 'There are significant differences in the subjective evaluation of the general sleep patterns among the four groups' was supported (F=3,638.73, p=.000). In addition the hypothesis, 'There are significant differences in degree of sleep among the four groups' was supported (F=1,616.61, p=.000). Conclusion: It is cost effective and a simple eye protective device and ear protective device should be applied to patients according to their preference and characteristics in the clinical setting.

Development and Evaluation of Smart Jacket with Embedded Wearable Device (웨어러블 디바이스를 이용한 기능성 스마트 재킷 개발 및 평가)

  • Lee, Jeong-Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.3
    • /
    • pp.395-407
    • /
    • 2008
  • As global interest in clothing spreads over the smart clothing which arouses high added-value in the apparel industry, this study is to develop a smart jacket with an electrically-vibrating device maintaining excellent appearance and comfort. The vibrating device has a massage function that could relieve muscle pain near shoulders and neck. The purposes of this research are to develop jacket pattern for men in their thirties considering body shapes and fashion trend, to develop a wearable device that is composed of motor and controller and integrate it into a jacket, and to assess the external appearance and functional satisfaction of the smart jacket through the wearing test. The results are as follows: 1. In order to develope an appropriate jacket pattern for men in their thirties, several patterns were assessed for their fitting comfort. The final pattern was completed after making alterations some parts, and showed high satisfaction as 3.6(on a five-point scale) in all categories. 2. A vibrating device was developed by connecting motor, controller, battery and switch. Developing this device, focus was maximizing the strength of motor and minimizing the heat generated from motor and controller. Snaps were placed between inner and outer cloth of jacket so that the vibrating device could be easily attachable and detachable. The motor was located around Trapezius where muscles often get stiff. A switch was designed to be used in selecting the modes of Strong, Weak, and Cross Tapping. 3. The wearing test was conducted to examine outer appearance, comfort for motion, and functionality of the smart jacket. The results of assessing outer appearance showed that the location for attaching the vibrating device was not noticeable but looked natural, and there is almost no change in outer appearance when the vibrating device operates. The result of assessing comfort of action revealed that wearer's satisfaction was high in all categories about activity, wearer's comfort, etc. The result also showed that wear's satisfaction for effects of vibrating massage, easiness in using the device, heat generation was not less than 3.5 in all categories except a category about noise.

Ergonomic Design of Necklace Type Wearable Device

  • Lee, Jinsil;Ban, Kimin;Choe, Jaeho;Jung, Eui S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.281-292
    • /
    • 2017
  • Objective: This study aims to identify important physical design variables in designing a necklace type wearable device, and to present design guidelines to maximize comfort that a user feels upon wearing the device. Background: Interests in fitness culture and personal health are on the rise recently. In such a situation, demand for necklace type wearable devices is projected to increase a lot, as the devices enable users to use their hands freely and to enjoy various contents through connection with mobile devices. However, the necklace type wearable device's comfort was assessed to have the lowest comfort in a running situation, where human body moves up and down and left and right more than other devices wearable on other human body parts. Therefore, the usability of a necklace type wearable device was low. In this regard, studies on identification of the variables affecting user comfort upon wearing a necklace type wearable device and on physical design direction maximizing comfort and usability are needed. Method: A pretest and a main test were carried out to draw the direction of necklace type wearable device design. In the pretest, wearing evaluation on the diverse types of devices released in the market was conducted to draw physical design variables of the devices affecting comfort. Furthermore, variables significantly affecting the comfort of a device were selected through an analysis of variance (ANOVA). In the main test, anthropometry was performed, and information on anthropometric items corresponding to the design variables selected in the pretest was acquired. Based on the pretest results and the anthropometric information in the main test, the present study produced design guidelines maximizing the comfort of a necklace type wearable device with regard to major design variables upon dynamic tasks. Results: According to the pretest results, the variables having effects on comfort were the angle of side points, width, and height. Due to interactions between variables, those need to be simultaneously considered upon designing a device. Upon dynamic tasks, the angle of side points and width of a device was designed to be smaller than mean angle of the trapezius muscle and neck width, and thus attachment to human body was high. As height was designed to be larger than mean neck front and rear point width, comfort was higher due to feeling of stability. Conclusion: Because user sensitivity to comfort was high at human body's inflection points, a device needs to be designed for users not to feel high pressure on specific body parts with the device fitting human body shape well. A design considering user's situation is also required in further studies.

Design Controller For Rapidity Temperature Measurement-system (넓은 영역의 온도범위를 가지는 급속 온도특성측정시스템 컨트롤러 설계)

  • 신광식;정완영
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.33-36
    • /
    • 2001
  • An automatic TCXO frequency-temperature test apparatus was firstly developed by using thermoelectric device may. The developed system swing stably the test temperature range from -40$^{\circ}C$ to +80$^{\circ}C$ for about 1 hour The rising temperature ratio was fairly linear with time in this test temperature range. The temperature could be controlled error in error range of ${\pm}$0.05$^{\circ}C$ in this system. The frequency-Temperature properties of TCXO or the thermoelectric properties of other electric device.

  • PDF