• Title/Summary/Keyword: Test Device

Search Result 3,559, Processing Time 0.035 seconds

A Study for Application of Standard and Performance Test According to Purpose and Subject of Respiratory Medical Device (호흡보조의료기기의 사용목적 및 대상에 따른 규격적용 방안 및 성능에 관한 연구)

  • Park, Junhyun;Ho, YeJi;Lee, Duck Hee;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.215-221
    • /
    • 2019
  • The respiratory medical device is a medical device that delivers optimal oxygen or a certain amount of humidification to a patient by delivering artificial respiration to a patient through a machine when the patient has lost the ability to breathe spontaneously. These include respirators for use in chronic obstructive pulmonary disease and anesthesia or emergency situations, and positive airway pressure devices for treating sleep apnea, and as the population of COPD (chronic obstructive pulmonary disease) and elderly people worldwide surge, the market for the respiratory medical devices it is getting bigger. As the demand for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, the boundaries between the items are blurred due to the purpose, intended use, and method of use overlapping similar items in a respiratory medical device. In addition, for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, in this study, we propose clear classification criteria for the respiratory medical devices according to the purpose, intended use, and method of use and provide safety and performance evaluation guidelines for those items to help quality control of the medical devices. And to contribute to the rapid regulating and improvement of public health. This study investigated the safety and performance test methods through the principles of the respiratory medical device, national and international standards, domestic and international licensing status, and related literature surveys. The results of this study are derived from the safety and performance test items in the individual ventilator(ISO 80601-2-72), the International Standard for positive airway pressure device (ISO 80601-2-70), The safety and performance of humidifiers (ISO 80601-2-74) and the safety evaluation items related to home healthcare environment (IEC 60601-1-11), In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers and importers, certified test inspection institutions, academia, etc., the final guidelines were established through revision and supplementation. Therefore, in this study, we propose guidelines for evaluating the safety and performance of the respiratory medical device in accordance with growing technology development.

A study on the acoustic performance test method using speaker of a noise reduction device for noise reduction of the 400km/h class high-speed railroad (스피커를 이용한 400km/h급 고속철도 소음저감용 방음벽 상단장치의 음향성능 시험방법에 관한 연구)

  • Yoon, Je-Won;Kim, Young-Chan;Jang, Kang-Seok;Eum, Ki-Young;Jang, Seung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.625-629
    • /
    • 2014
  • For the purpose of the acoustic performance evaluation of noise reduction device(NRD) installed at the top of noise barrier for further decreasing of noise level of 400km/h class high-speed railroad(HEMU), the acoustic performance test method using speaker instead of really running railway vehicle was suggested in this paper. For this, noise source location and frequency spectrum of HEMU was analyzed through the field noise test. These data were used for the determination of speaker's installation positions and frequency correction values applied to the speaker noise source. And, 400 meters long NRD was installed at the site where HEMU will be running at a speed of 400km/h. Finally, the outdoor speaker test with and without NRD showed that this NRD could decrease noise level even more than 3dB(A). In the future, the acoustic performance results of NRD conducted with speaker test will be compared with that of field test for HEMU running at a speed of 400km/h.

  • PDF

Design of a Torque Application Device in Test Rig for a Wind Turbine Gearbox (풍력발전기용 증속기 시험 장비의 토크 인가 장치 설계)

  • Kim, Jeong-Gil;Park, Young-Jun;Lee, Geun-Ho;Nam, Yong-Yun;Oh, Joo-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.5
    • /
    • pp.507-515
    • /
    • 2015
  • This study was conducted to develop and verify a torque application device for use in a mechanical power-circulation test rig for 5.5 MW wind turbine gearboxes. The design and analysis of the torque application device was conducted. In addition, the torsional stiffness of the test rig was calculated using the rotational angle measurements for each of the components. The calculated stiffness of the test rig was $231.13kN{\cdot}m/rad$ for a clockwise torque application. The rated torque can be applied when the stiffness of the gearbox is greater than $1,064,400kN{\cdot}m/rad$ for a clockwise torque application. Because of the limited rotational angle of the test rig, the potential application of the rated torque is determined according to the torsional stiffness of the test gearbox.

Student Responses to Smart Device-Based Test on Competency Evaluation in Dental Education

  • Kim, Jooah;Kim, Soo-Yoon
    • Journal of Korean Dental Science
    • /
    • v.12 no.2
    • /
    • pp.58-65
    • /
    • 2019
  • Purpose: This study was aimed to investigate the possibility of utilizing smart device-based test (SBT) for competency evaluation in dental education and to analyze the student responses on overall competency evaluation using SBT method, in comparison to ubiquitous-based test (UBT). Materials and Methods: Questionnaire surveys have been conducted at Yonsei University College of Dentistry from 2015 to 2018 to obtain students' feedback on the application of SBT to competency evaluation. In addition, in order to supplement the competency evaluation procedure, considerations were explored by comparing the expected and actual difficulty of each item when preparing items for competency evaluation with SBT. Result: According to the survey results, student responses between the initial two years (2015 and 2016) differed from those in next two years (2017 and 2018). Students in 2017 and 2018 had more positive responses on competency evaluation with SBT. To determine the test validity, criterion-referenced evaluation was adopted to compare the data in 2017 and 2018 and slight differences in test difficulty in 2018 between the expected and actual difficulty of items were found. Conclusion: The results indicated that SBT was more appropriate for competency evaluation than UBT, based on four-year period of competency evaluation. The SBT was not affected by either the file size or the number of test-takers. Interestingly, students were not sensitive to test version of competency evaluation (paper-based test and SBT). This study suggests that the quality of the test items should be measured by continuous monitoring of the expected and actual difficulty of items for determining test validity. More detailed results and discussions of the findings are given for the development of test procedure and further potential research directions in dental education.

Development of Electro-Mechanical Ignition Safety Device (전기-기계식 점화안전장치 개발)

  • Jang, Seung-Gyo;Kang, Ho-Joon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.332-335
    • /
    • 2011
  • Electro-Mechanical Ignition Safety Device(EMISD) for solid rocket motor is designed and manufactured. The EMISD utilizes a true rotary solenoid for arming mechanism and an electric squib(initiator) for generating ignition energy. In order to prove the ignition capability of the EMISD, 10-cc Closed Bomb Test(CBT) is performed, which measures the pressure built by high temperature and high pressure gas generated by operating EMISD.

  • PDF

Development of The M-PHY AFE Block Using Universal Components (범용 부품을 이용한 M-PHY AFE Block 개발)

  • Choi, Byung Sun;Oh, Ho Hyung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.2
    • /
    • pp.67-72
    • /
    • 2015
  • For the development of UFS device test system, M-PHY specifications should be matched with MIPI-standard which is analog signal protocol. In this paper, the implementation methodology and hardware structure for the M-PHY AFE (Analog Front End) Block was suggested that it can be implemented using universal components without ASIC process. The testing procedure has a jitter problem so to solve the problems we using ASIC process, normally but the ASIC process needs a lot of developing cost making the UFS device test system. In is paper, the suggestion was verified by the output signal which was compared to the MIPI-standard on the Prototype-board using universal components. The board was reduced the jitter on the condition of HS-TX and 5.824 Gbps Mode in SerDes (Serialize-deserializer). Finally, the suggestion and developed AFE block have a useful better than ASIC process on developing costs of the industrial UFS device test system.

The Characteristics of SMD Inductor Core (SMD Inductor Core의 전기적 특성)

  • Oh, Yong-Chul;Kim, Jin-Sa;Lee, Dong-Gyu;Shin, Chul-Ki;Kim, Ki-Joon;Lee, Chul-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.85-88
    • /
    • 2005
  • In this study, it analysis electric field of SMD(Surface Mounted Device) Inductor Core and it get electric field only exist inside of SMD core. Therefore electric fields do not affect any device and equipments. These results are very important to design data acquisition system(several test equipments such as temperature, impedance, and current test), because data acquisition system can place under the SND Inductor core. So, it can be decrease their test error due to electric field.

  • PDF

Environmental Tests of Kick Motor Safety and Arming Device (킥모터 점화안전장치 환경시험)

  • Koh, Hyeon-Seok;Kil, Gyoung-Sub;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.703-704
    • /
    • 2010
  • The environmental tests simulating the flight condition have been performed to manufacture the high reliable safety and arming device(SAD). A motor assay in preliminary design was reinforced with the structure to resist severe vibration and shock environment, and the design change had been verified by conducting the principal environmental test again.

  • PDF

Damage Evaluation of CD-RW Drive by Drop Test and Simulation (CD-RW Drive의 낙하충격 손상평가)

  • Woo Jae Chul;Yun Ki Won;Seok Ki Young;Kim Heon Young;Kim Sang Bum
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.1 s.232
    • /
    • pp.81-87
    • /
    • 2005
  • A fracture of hand held device, such as radio, TV and CD-RW drive, mainly occurs due to drop situation. For CD-RW drive, the need of high reading/writing speed in conjunction with low price accelerates the fracture of the device. Computer simulation can reduce the period of development and enhance impact characteristic of device. In this study, the detailed finite element model of CD-RW drive was developed to predict the damage under drop conditions. Material property for shock absorbing damper was obtained from tensile test of raw material. A MOONEY-RIVLIN type rubber in LS-DYNA was used as the material model of damper. To assess the reliability of the developed model, drop test at 200G-2msec and 150G-10msec condition was conducted and acceleration at pick-up was compared.

The Study of Circuit Model Parameter Generation Using Device Simulation (소자 시뮬레이션을 이용한 Circuit Model Parameter 생성에 대한 연구)

  • 이흥주
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.177-182
    • /
    • 2003
  • In the case of the flash memory, various kinds of transistors and the wide range of operation voltage are necessary to achieve the read/write operations. Therefore, the characteristics of transistors are measured in the silicon for the circuit design, and the test vehicle run must be processed. In this study, an efficient design flow is suggested using TCAD tools. The test vehicle is replaced with well-calibrated TCAD simulation. First, the calibration methodology is introduced and tested for flash memory device. The calibration errors are less than 5% of a full chip operation, which is accepted by the designers. The results of the calibration were used to predict I-V curves and model parameter of the various transistors for the design of flash device.

  • PDF