Experimental Analysis of Ceramic Coated High Power Brake Discs (세라믹 코팅 고에너지 제동 디스크의 마찰특성 연구)

  • 강부병;이희성
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.97-107
    • /
    • 1998
  • Three different kinds of brake discs including two coated brake discs and one steel disc were tested under the same experimental conditions on a reduced scale braking test bench. Braking test bench was specially designed to analyse thermo-mechanical and frictional behaviors of two sizes of brake discs in stop and hold braking modes. And Plasma spray coating technique was used to coat ceramic powder on the discs. In the test four commercial brake pads were coupled with discs. Ceramic coated discs had shown good stability in friction coefficient at high speed and high energy braking conditions. But they caused large pad mass wear loss compared with the steel disc. It was shown that thermal barrier effect in ceramic coated discs adjusted the thermal partition between pad and disc. For a steel disc, it had shown fluctuating friction coefficient at high speed but a fittie pad mass wear loss compared with ceramic coated discs.

  • PDF

A Performance Assessment of 2MW Wind Turbine Gearbox by Considering Various Operating Conditions (다양한 운전조건을 고려한 2MW 풍력증속기의 성능평가)

  • Jo, Joon-Haeng;Park, Koo-Ha;Moon, Byung-Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.391-394
    • /
    • 2007
  • Wind turbine gearbox is a complex mechanical system that includes gear trains, shafts, bearings, and gearbox housings. All these components are interacting with each other therefore it is important to assess the whole performance by considering the individual component design. In this paper, the performance assessment of 2MW wind turbine gearbox was conducted under various operating conditions at test bench and test result was compared with the design calculation.

  • PDF

Optical bench design rule formulated by statistical design of experiment (통계적 실험 계획법을 이용한 광학 벤치 설계 규칙의 설정)

  • 박세근;이재영;이승걸
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.123-127
    • /
    • 2002
  • In order to set up the design rule of micro optical bench, optical coupling efficiencies of two sets of test benches are calculated. Simple linear connections of incoming and outgoing optical fibers with and without ball lenses are designed. Positional errors that are possible in actual fabrication processes are considered in the calculations and their tolerances are determined from 3dB conditions. For a simple fiber-to-fiber connection, the working distance is limited to $2.7\mu\textrm{m}$ and tilt error $5.8^{\circ}$. When ball lenses are located in front of each fiber, the working distance can be extended over $60\mu\textrm{m}$ , but the positional errors have the strong interaction among position parameters and thus should be considered simultaneously for tolerance design.

  • PDF

Changes in Total Work, Total Work Ratio, Heart Rate, and Blood Lactate during 75% 1-RM Bench Press Exercise

  • Kim, Ki Hong;Kim, Byung Kwan
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.153-160
    • /
    • 2021
  • Background and Objectives This study was conducted to investigate the change of total work and total work ratio for each set, peak heart rate during exercise, and blood lactate for each set during the 5-set bench press exercise at 75% one repetition maximum test (1-RM). Materials and Methods Seven men in their 20s with more than 6 months of experience doing resistance exercises were selected as subjects, and their 1-RM bench press was measured two weeks before the experiment and 75% 1-RM was measured one week before the experiment. In this study, total work was measured for each set, and heart rate was measured during rest and set-by-set exercise. Blood lactate was measured during rest time after each set. The raw data were analyzed by repeated one-way ANOVA. Results Total work and total work ratio decreased from 1 set to 4 sets (p < .05), p < .001), heart rate increased from stable at the start of exercise (p < .001) and decreased between 3 sets and 4 sets (p < .05). Blood lactate increased continuously up to 2 sets (p < .001, p < .01). Conclusion In conclusion, total work and heart rate decreased with muscle fatigue during exercise, and blood lactate continuously increased. The results of this study are expected to be useful references for constructing resistance exercise programs in the future.

An Analysis of Bench Mark Accuracy through the Development of Smart Leveling Equipment (스마트기기를 활용한 수준측량장비 개발 및 성능분석)

  • Kim, Yong-Suk;Yi, Gi-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 2017
  • A smart leveling equipment was developed in this study by improving present leveling equipment. Both hardware and software of the equipment was developed and several accuracy tests of bench mark were conducted using various survey equipments. National control point (UO992-A), control points (15-00-06-24)-B and (15-00-06-23)-C were used for the accuracy test. As a result, the stable results in the range of errors were obtained in the cases of auto-level and digital level. Approximately 24mm error in the section of A-B and 26mm of B-C section was occurred in Smart Level equipment. This is due to the lack of technology completion and errors via relatively many numbers of installation tests. 46mm error of RMSE of smart level survey was occurred through the difference of section test. A small error was detected in short range but errors were accumulated far from the bench mark. It's concluded that an in-depth study emphasizing accuracy improvement can be practically applied to the various areas of industry.

Emission test of a domestic fabricated cathode with higher current density

  • Ju, Yeong-Do;Gong, Hyeong-Seop;Kim, Seung-Hwan;Tanwar, Anil;Seok, Yeong-Eun;Lee, Byeong-Jun;Hong, Yong-Jun;Sin, Jin-U;So, Jun-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.205.2-205.2
    • /
    • 2016
  • The emission test a domestic fabricated cathode is conducted using an easy-replaceable-emitter-type test bench. A simple cylindrical button type cathode is dropped vertically into a cathode cup holder. The cathode is heated by a tungsten wire heater located around the cup holder. The cathode temperature is measured by an optical pyrometer. A high voltage pulse power supply gives the anode-cathode gap voltage up to 20 kV with the pulse width of 15 us. The emitted current from the cathode is captured at a faraday cup and is measured using current transformer and oscilloscope. The test bench is installed in the vacuum chamber with easy access door and, therefore, the cathode can be easily replaceable. We confirmed the emission current density of $15A/cm^2$ and $80A/cm^2$ with a domestic fabricated B-type cathode and a Scandate cathode, respectively. The detailed test result for the cathode will be presented.

  • PDF

Development of Helicopter Chassis Dynamometer System for the Scaled Helicopter Ground Test (축소 헬기 지상시험을 위한 헬리콥터 섀시다이나모미터 개발)

  • Kim, Ick-Tae;Kim, Jae-Soo
    • Aerospace Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.185-191
    • /
    • 2012
  • This paper developed Helicopter Chassis Dynamometer System(HCDS) to perform the bench test of the scaled rotor blade and to design a scaled model helicopter flight test bed and accomplished the scaled helicopter ground test. The scaled helicopter should be checked the relation of thrust and power input to maintain regular RPM by collective pitch angle versus throttle input. It showed hovering performance results of IGE with OGE, the max. F.M. was 0.76 without ground effect. The results of the chassis dynamometer test of scaled helicopter will usefully apply to design the scaled helicopter and evaluate the rotor blade performance.

Application of a Hydraulic Rock Splitting System to Bench-Cut Field Experiments (수압암반절개시스템을 이용한 벤치컷 현장 적용 사례 연구)

  • Park, Jong Oh;Woo, Ik
    • The Journal of Engineering Geology
    • /
    • v.32 no.4
    • /
    • pp.725-733
    • /
    • 2022
  • This study applied a hydraulic rock splitting system equipped with a hybrid packer to the bench-cut method. The hybrid packer system is an improvement of the packer developed in previous studies; it is designed efficiently to reduce vibration and noise during rock excavation by combining the two functions of inducing hydraulic fractures using injection pressure and then expanding and extending them using a rubber packer. Field experiments assessed the efficiency of rock excavation with respect to the injection conditions; the adjusted experimental conditions included the distance from the free surface and the test holes drilled at the top of the slope and the injection settings. Using a separation of 5 m left some unexcavated parts, but using a separation of 1 m left no unexcavated parts. The hydraulic fractures generated by the injection pressure developed generally parallel to the free surface and expanded and extended as the rubber packer expanded, thus facilitating bench-cut excavation. For hydraulic rock splitting to be broadly applicable to bench-cut rock excavation, it is important to accumulate results from many field experiments conducted under varying experimental conditions for various types of rockmass.

The Study of Safety Evaluation of Improvement on LOWER ARM (II) (개선설계된 LOWER ARM의 안전성 평가에 관한 연구 (II))

  • 박영철;윤두표;허선철;진두병;이범재
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.3
    • /
    • pp.18-25
    • /
    • 1998
  • This paper performed stress analysis and bench test for the LOWER ARM of H' type which was improved on LOWER ARM with the section of H type. And we investigated the safety of the section of H' type. The results of this study are as follows ; The section of H' type satisfied the required safety factor and has the highest stress value on the B part of the LOWER ARM. And the magnitude is similar to the fatigue strength of the GCD45(300㎫). Hence, the H' type has an advantage to reduce the cost of production.

  • PDF

The Effect of Joint Condition on Rock Fragmentation in Bench Blasting (절리간격과 방향이 벤치발파시 암석파쇄도에 미치는 영향에 대한 실험 연구)

  • Choi Yong-Kun;Lee Chung-In
    • Explosives and Blasting
    • /
    • v.23 no.2
    • /
    • pp.37-44
    • /
    • 2005
  • Recent studies reported that natural block size of rock and joint orientation highly affect on rock fragmentation. In this study, blasting test using high strength cement mortar was carried out to verify this fact. The result of this test indicated that fragmentation is influenced by the joint interval, and at same joint interval condition, fragmentation depends on joint orientation. These results are significantly coincident with field investigations.