• Title/Summary/Keyword: Term Remove

Search Result 160, Processing Time 0.024 seconds

Design of Screening Inspection in a Multi-Stage Manufacturing Systems (다공정 제조시스템에서의 전수검사에 관한 연구)

  • 박영현;이창호
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.1
    • /
    • pp.1-16
    • /
    • 1997
  • In this paper, we illustrate how to design screening inspections for minimizing a total quality costs in a multi-stage manufacturing systems. The total quality cost model consists of inspection costs, internal failure costs, external failure costs, and Taguchi's loss function. Although, the use of automatic test equipment such as machnie vision and CMM has greatly increased inspection speed and accuracy, screeing(100% inspection) could be considered only as a short-term method to remove nonconforming items from a population, not for a long-term quality improvement. However, screeing should be used for certain situations such as before costly operations and after unsatisfied operations. This paper ends with an example that demonstrates the usefulness of the model.

Multi-document Summarization Based on Cluster using Term Co-occurrence (단어의 공기정보를 이용한 클러스터 기반 다중문서 요약)

  • Lee, Il-Joo;Kim, Min-Koo
    • Journal of KIISE:Software and Applications
    • /
    • v.33 no.2
    • /
    • pp.243-251
    • /
    • 2006
  • In multi-document summarization by means of salient sentence extraction, it is important to remove redundant information. In the removal process, the similarities and differences of sentences are considered. In this paper, we propose a method for multi-document summarization which extracts salient sentences without having redundant sentences by way of cohesive term clustering method that utilizes co-occurrence Information. In the cohesive term clustering method, we assume that each term does not exist independently, but rather it is related to each other in meanings. To find the relations between terms, we cluster sentences according to topics and use the co-occurrence information oi terms in the same topic. We conduct experimental tests with the DUC(Document Understanding Conferences) data. In the tests, our method shows better performance of summarization than other summarization methods which use term co-occurrence information based on term cohesion of document or sentence unit, and simple statistical information.

A acupuncture therapy literature study on the hemorrhoids and hemorrhoids complicated by anal fistula (치창(痔瘡)과 치루(痔漏)에 대한 침구학적(鍼灸學的) 문헌고찰(文獻考察))

  • Song, Won-sub;Lee, Byung-ryul;Lee, Hyun;Chae, Sang-jin
    • Journal of Acupuncture Research
    • /
    • v.20 no.1
    • /
    • pp.131-143
    • /
    • 2003
  • Objective : The purpose of this study is to arrange the literature about acupuncture therapy on the hemorrhoids and hemorrhoid complicated by anal fistula. Methods : We arrange Huang Di Nei Jing and fifteen kinds of literature about the hemorrhoids and hemorrhoid complicated by anal fistula. Results : 1. The cause of hemorrhoids are overfatigue, overeating, imbalance of stool(const-ipation or diarrhea), uncontrol sexual excess or abstinence, pathgenic factors of wetness, heat, wind, dry, fire, chronical hemorrhoids that has not been treated, and general weakness. 2. Symptom of hemorrhoids is that skin is projected form the nine holes or varicose extension to become hemorrhoid. Hemorrhoids is small nodosity that projected on the anal inter or outer region, and hemorrhoid complicated by anal fistula is pus which comes out form one or some fistula on the anal around inter and outer region. 3. Therapy method of hemorrhoid and hemorrhoid complicated by anal fistula are elimination pathological heat from blood, promote blood flow to remove blood stasis, cold in nature and purge away fire, remove heat form the blood, promote blood flow to remove blood stasis, cold in nature and purge away fire, remove heat from the blood and eliminate dampness, tonify the spleen and replenish Ki, dispel wind and alleviate pain and so forth. Therapy method of hemorrhoid is to give the first consideration to relieve blood: eliminating pathological heat form blood complicated by anal fistula is to tonify the blood first, than after that eliminating pathological heat form blood. About external method are method of fumigation, method of ointment, method of close with medicine, necrotizing method and also operation(injection, bind etc.)was used for treatment. 4. The prescription are Gurgak-hwan, Wypi-hwan, Gunggyi-tang, Jingyochangchul-tang, Jingyobangpung-tang, Mokhyangbinrang-hwan, Ochi-san, Gamihyanso-san, Jojang-hwan, Sinyung-hwan used frequently. 5. food taboo on patient's diet of the hemorrhoid and hemorrhoid complicated by anal fistula are raw grain, cold or dampness food, alcohol, hot food, Singiberis rhizoma recens, Cinnamomi ramulus. 6. Acupuncture therapy on the hemorrhoid and hemorrhoid complicated by anal fistula are, in the first stage eliminating pathological heat form blood and eliminate dampness, and in the long term eliminate dampness, promote and remove meridian energy, remove that form the intestines, dispel channels and collaterals. 7. Acupuncture points at B2, CV1, B58, B36, B56, Sp5, S30, B25, B54, GV1, GV20, L6, B40 used frequently for the acupuncture therapy, and acupuncture point at GV4, GV1, B30, hemorrhoidal point used form moxibustion. Reduction blood at B40 and blue capillary of Sp9 and acupuncture Chungbaek, Ki-gack, Ki-jung, Ki-mun(Dongsh Kihyel) makes the treatment very effective.

  • PDF

Long Term Operation of Microfiltration as a Pretreatment for Seawater Reverse Osmosis Processes (정밀여과를 이용한 역삼투법 해수담수화 전처리 공정의 장기운전 특성)

  • Kim, Su-Han;Kim, Chung-H.;Kang, Suk-H.;Lim, Jae-L.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.735-741
    • /
    • 2010
  • A pilot test was carried out to investigate the long term operation characteristics of Microfiltration (MF) system as a pretreatment for seawater reverse osmosis (SWRO) processes for two years. A commercialized MF module with pressurized operation type was used to filter seawater to remove particles which can foul reverse osmosis (RO) membrane. Silt Density Index (SDI) values of filtered seawater by the MF system were ranged from 0.14 to 1.79, which meet the SDI standard for RO feed water as depicted in previous literatures. Although the tested seawater is quite clean (i.e., dissolved organic cabon (DOC) concentration and turbidity were about 1 mg/l and less than 1 NTU, respectively) enough not to foul the MF membrane, steep increase in trans-membrane pressure (TMP) with a constant flux were observed over a whole operation period. A set of operation and water analysis data implies that the steep increase in TMP was resulted from iron and maganese fouling by the combination of metal corrosion by seawater and oxidation state by aeration and residual chlorine.

Real-time SCR-HP(Selective catalytic reduction - high pressure) valve temperature collection and failure prediction using ARIMA (ARIMA를 활용한 실시간 SCR-HP 밸브 온도 수집 및 고장 예측)

  • Lee, Suhwan;Hong, Hyeonji;Park, Jisoo;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.1
    • /
    • pp.62-67
    • /
    • 2021
  • Selective catalytic reduction(SCR) is an exhaust gas reduction device to remove nitro oxides (NOx). SCR operation of ship can be controlled through valves for minimizing economic loss from SCR. Valve in SCR-high pressure (HP) system is directly connected to engine exhaust and operates in high temperature and high pressure. Long-term thermal deformation induced by engine heat weakens the sealing of the valve, which can lead to unexpected failures during ship sailing. In order to prevent the unexpected failures due to long-term valve thermal deformation, a failure prediction system using autoregressive integrated moving average (ARIMA) was proposed. Based on the heating experiment, virtual data mimicking temperature range around the SCR-HP valve were produced. By detecting abnormal temperature rise and fall based on the short-term ARIMA prediction, an algorithm determines whether present temperature data is required for failure prediction. The signal processed by the data collection algorithm was interpolated for the failure prediction. By comparing mean average error (MAE) and root mean square error (RMSE), ARIMA model and suitable prediction instant were determined.

Study on the Seasoning Effect for Amorphous In-Ga-Zn-O Thin Film Transistors with Soluble Hybrid Passivation

  • Yun, Su-Bok;Kim, Du-Hyeon;Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.256-256
    • /
    • 2012
  • Oxide semiconductors such as zinc tin oxide (ZTO) or indium gallium zinc oxide (IGZO) have attracted a lot of research interest owing to their high potential for application as thin film transistors (TFTs) [1,2]. However, the instability of oxide TFTs remains as an obstacle to overcome for practical applications to electronic devices. Several studies have reported that the electrical characteristics of ZnO-based transistors are very sensitive to oxygen, hydrogen, and water [3,4,5]. To improve the reliability issue for the amorphous InGaZnO (a-IGZO) thin-film transistor, back channel passivation layer is essential for the long term bias stability. In this study, we investigated the instability of amorphous indium-gallium-zinc-oxide (IGZO) thin film transistors (TFTs) by the back channel contaminations. The effect of back channel contaminations (humidity or oxygen) on oxide transistor is of importance because it might affect the transistor performance. To remove this environmental condition, we performed vacuum seasoning before the deposition of hybrid passivation layer and acquired improved stability. It was found that vacuum seasoning can remove the back channel contamination if a-IGZO film. Therefore, to achieve highly stable oxide TFTs we suggest that adsorbed chemical gas molecules have to be eliminated from the back-channel prior to forming the passivation layers.

  • PDF

A digital Controller Design to Improve Steady-State characteristics (전상상태 특성을 개선한 디지털 제어기 설계)

  • Kim, Yeong-Gil;Park, Mi-Yong;Lee, Sang-Bae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.6
    • /
    • pp.1-6
    • /
    • 1985
  • The reference input is one of causes having an effect upon the steady-state error. This paper dcscribes a design method of a digital controller to remove the stcadyftate error caused by the reference input. According to the types of the reference input, new system equations to remove the reference input term from controlled system equations are derived first. And, using the optimal control theory the control law is obtained to minimize the output of the new system. Based on the state-space approach, the proposed control algo-rithm can be applied to time-invariant linear systems including the unstable systems.

  • PDF

Thermal-hydraulic study of air-cooled passive decay heat removal system for APR+ under extended station blackout

  • Kim, Do Yun;NO, Hee Cheon;Yoon, Ho Joon;Lim, Sang Gyu
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.60-72
    • /
    • 2019
  • The air-cooled passive decay heat removal system (APDHR) was proposed to provide the ultimate heat sink for non-LOCA accidents. The APDHR is a modified one of Passive Auxiliary Feed-water system (PAFS) installed in APR+. The PAFS has a heat exchanger in the Passive Condensate Cooling Tank (PCCT) and can remove decay heat for 8 h. After that, the heat transfer rate through the PAFS drastically decreases because the heat transfer condition changes from water to air. The APDHR with a vertical heat exchanger in PCCT will be able to remove the decay heat by air if it has sufficient natural convection in PCCT. We conducted the thermal-hydraulic simulation by the MARS code to investigate the behavior of the APR + selected as a reference plant for the simulation. The simulation contains two phases based on water depletion: the early phase and the late phase. In the early phase, the volume of water in PCCT was determined to avoid the water depletion in three days after shutdown. In the late phase, when the number of the HXs is greater than 4089 per PCCT, the MARS simulation confirmed the long-term cooling by air is possible under extended Station Blackout (SBO).

A Study on Dissolve and Remove Analysis of Organic Chemicals Using a Mixed Method of Advanced Oxidation and Micro Filtering - Water Drinking Point - (고도산화와 정밀여과의 혼성공법을 이용한 유기화학물질의 분해 및 제거분석에 관한 연구 - 먹는 물을 중심으로 -)

  • An, Tai-Young;Jun, Sang-Ho;Ahn, Tae-Seok;Han, Mi-Ae;Hur, Jang-Hyun;Pak, Mi-Young
    • Membrane Journal
    • /
    • v.17 no.2
    • /
    • pp.99-111
    • /
    • 2007
  • It is impossible to remove toxic organic substances that are recognized as a cancer caused suspicious element in drinking water using the conventional water purification method. This study introduces groundwater into a reaction chamber as an effective amount of water to process this water using a mixed method of AOP oxidation and M/F membrane and purifies it as a desirable level by artificially mixing such toxic substances in order to effectively process the water. Based on this fact, this study configures an optimal operation condition. The VOCs existed in toxic substances was investigated as a term of phenol and toluene, and agricultural chemicals were also investigated as a term of parathion, diazinon and carbaryl. The experiment applied in this study was performed using a single and composite soolution. In the operation condition applied to fully dissolve and remove such substances, the amount of $H_2O_2$ injected in the process was 150 mL of a fixed quantity, the value of pH was configured as $5.5{\sim}6.0$, the temperature was controlled as a range of $12{\sim}16^{\circ}C$, the dissolved amount of ozone was applied more than 5.0 mg/L, the reaction time was determined as an optimal condition, such as $30{\sim}40$ minutes, and the segregation membrane in the same reactor was determined for acquire water drinking of large quantity using a pore size of $0.45{\mu}m$ M/F membrane.

Experimental Study on the Long-term Performance of TiO2 Concrete for Road Structures (도로 구조물 적용을 위한 TiO2 콘크리트의 장기공용성에 대한 실험적 연구)

  • Lee, Jun Hee;Kim, Young Kyu;Lee, Seung Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.691-698
    • /
    • 2015
  • In the area of high traffic volume, such as expressway across large cities, the amount of nitrogen oxides (NOx) emitted into the atmosphere as air pollution can be significant since NOx gases are the major cause of smog and acid rain. Recently, the importance of NOx removal has arisen in the world. Titanium dioxide ($TiO_2$), that is one of photocatalytic reaction material, is very efficient for removing NOx. Therefore, application of $TiO_2$ concrete is a good alternative in order to remove NOx which is a main cause of air pollution. This experimental study aimed to evaluate the long-term performance of $TiO_2$ concrete such as NOx removal efficiency due to performance period and environmental resistance for application of road structures. It was found that the $TiO_2$ is reasonable applicable on the road structure because $TiO_2$ concrete has a long-term performance.