• Title/Summary/Keyword: Term Extraction

Search Result 339, Processing Time 0.028 seconds

Case report of a newly designed narrow-diameter implant with trapezoid-shape for deficient alveolar bone (좁은 치조골에서 사다리꼴형 디자인으로 개발된 단폭경임플란트의 증례 보고)

  • Lee, Sa Ya;Goh, Mi-Seon;Ko, Seok-Yeong;Yun, Jeong-Ho
    • The Journal of the Korean dental association
    • /
    • v.56 no.5
    • /
    • pp.263-276
    • /
    • 2018
  • Long-term survival and prognosis of narrow-diameter implants have been reported to be adequate to consider them a safe method for treating a deficient alveolar ridge. The objective of this study was to perform case report of narrow-diameter implants with a trapezoid-shape in anterior teeth alveolar bone. A 50-year-old male patient presented with discomfort due to mobility of all of the maxillary teeth and mandibular incisors. Due to destruction of alveolar bone, four anterior mandibular teeth were extracted. Soft tissue healing was allowed for approximately 3 months after the extraction, and a new design of implant placement was planned for the mandibular incisor area, followed by clinical and radiological evaluation. Implant placement was determined using an R2GATE surgical stent. The stability of the implants was assessed by ISQ measurements at the first and second implant surgery and after prosthetic placement. At 1 and 3 months and 1 year after implantation of the prosthesis, clinical and radiological examinations were performed. Another 50-year-old male patient presented with discomfort due to mobility of the mandibular central incisors. For the same reason as in the first patient, implant placement was carried out in the same way after extraction. ISQ measurements and clinical and radiological examinations were performed as in the previous case. In these two clinical cases, 12 months of follow-up revealed that the implant remained stable without inflammation or additional bone loss, and there was no discomfort to the patient. In conclusion, computer-guided implant surgery was used to place an implant in an optimal position considering the upper prosthesis. A new design of a narrow-diameter implant with a trapezoid-shape into anterior mandibular alveolar bone is a less invasive treatment method and is based on the contour of the deficient alveolar ridge. Through all of these procedures, we were able to reduce the number of traumas during surgery, reduce the operation time and total treatment period, and provide patients with more comfortable treatment.

  • PDF

Degradation rate of several types of Calcium Polyphosphate;Long term results (다양한 형태의 다공질 Calcium Polyphosphate의 생분해성에 관한 장기적인 연구)

  • Yang, S.M.;Seol, Y.J.;Kye, S.B.;Lee, I.K.;Lee, C.W.;Kim, S.Y.;Lee, Yong-Mu;Ku, Y.;Han, S.B.;Chung, C.P.;Choi, S.M.;Rhyu, I.C.
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.2
    • /
    • pp.301-310
    • /
    • 2003
  • The purpose of this study is to evaluate the biocompatibility and the biorsorbability of several types of calcium polyphosphate made through change of manufacturing process for 12 month. To solve limitation of calcium phosphate, we developed a new ceramic, Calcium Polyphosphate(CPP), and report the biologic response to CPP in extraction sites of beagle dog. Porous CPP blocks were prepared by condensation of anhydrous $Ca(H_2PO_4)_2$ to form non-crystalline $Ca(PO_3)_2$ and then milled to produce CPP powder. CPP powder, CPP block, and CPP granules added with $Na_2O$ were implanted in extraction sockets and histologic observation were performed at 12 months later. Like 3 months results, histologic observation at 12 months revealed that CPP matrix were mingled with and directly apposed to new bone without any adverse tissue reaction, CPP powder show direct bony contact, but new bone formation and fibrous tissue encapsulation showed in CPP block. 10% $Na_2O$ CPP granules show more inflammatory cells infiltration around graft materials compared at 3 month, but 15% $Na_2O$ CPP granules show less. This result revealed that regardless of addition of $Na_2O$, CPP had a high affinity for bone and had been resorbed slowly. From this results, it was suggested that CPP is promising ceramic as a bone substitute and addition of $Na_2O$ help biodegradation but optimal concentration of $Na_2O$ and other additive component to increase degradation rate should be determined in further study.

Review of Material Flow Analysis Related Activities of Developed Countries for the Improvement of Resources Efficiency and Sustainability (자원 효율성 및 지속 가능성 증진을 위한 선진국 물질흐름분석 관련활동에 대한 평가)

  • Kim, Seong-Yong
    • Economic and Environmental Geology
    • /
    • v.39 no.5 s.180
    • /
    • pp.615-626
    • /
    • 2006
  • The natural resources and material life-cycle include all human activities related to resources and material extraction, transportation, processing, use, recovery and disposal. Sustainable material management (SMM) is an integrated set of policy approaches targeted on economic agents throughout the material life-cycles and designed to result in economically efficient and environmentally effective material use. The material flows of industrial mineral, ores and fossil fuels have also long been a focal area for environmental policies because of the high environmental pressures associated with extraction, processing, consumption, and final disposal of these materials. OECD work on material flow is to improve the quantitative and analytical knowledge bases about natural resource and material flows within and among countries, so as to better understand the importance of material resources in member countries' economies. In several EU Member States, material flow accounts are part of official statistics. Material flow analysis (MFA) is a valuation method which assesses the efficiency of use of materials using information from material flow accounting. Material flow analysis helps to identify waste of natural resources and other materials in the economy which would otherwise go unnoticed in conventional economic monitoring systems. Resource use and resource efficiency has emerged as a major issue for long-term sustainability and environmental policy.

Extraction of Waterline Using Low Altitude Remote Sensing (저고도 원격탐사 영상 분석을 통한 수륙경계선 추출)

  • Jung, Dawoon;Lee, Jong-Seok;Baek, Ji-Yeon;Jo, Young-Heon
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_2
    • /
    • pp.337-349
    • /
    • 2020
  • In this study, Helikite, Low Altitude Remote Sensing (LARS) platform, was used to acquire coastal images. In the obtained image, the land and water masses were divided using four types of region clustering algorithms, and then waterline was extracted using edge detection. Quantitative comparisons were not possible due to the lack of in-situ waterline data. But, based on the image of the infrared band where water masses and land are relatively clear, the waterlines extracted by each algorithm were compared. As a result, it was found that each algorithm differed significantly in the part where the distinction between water masses and land was ambiguous. This is considered to be a difference in the process of selecting the threshold value of the digital number that each algorithm uses to distinguish the regions. The extraction of waterlines through various algorithms is expected to be used in conjunction with a Low Altitude Remote Sensing system that can be continuously monitored in the future to explain the rapid changes in coastal shape through several years of long-term data from fixed areas.

Surgical Treatment of Varicose Vein - TIPP(Transilluminated Powered Phlebectomy) - (정맥류 환자의 수술적 치료 -광투시 전도형 정맥적출요법-)

  • 이교준;김해균;정은규;강두영
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.144-148
    • /
    • 2002
  • The present study was done to determine the efficacy and safety of varicose vein removal using a minimally invasive, powered vein-extracting device with cutaneous transillumination and tumescent anesthesia techniques and then compared this to a retrospective group of conventional phlebectomy operations. There were 133 limbs in 104 patients(72 women, 32 men) treated with the use of the vein extractor aided by transcutaneous illumination. The hydrodissection was performed with Trivex™ Irrigated illuminator(Smith & Nephe $w^{ R}$) system using normal saline after the 2~3mm sized skin incision. Varicose clusters were extracted by the use of TriveTM esector(Smith & Nephe $w^{ R}$) system under transillumination. After the varisoce vein extraction, the operation area was compressed with surgical pad for bleeding control. The complication rate was 3.84% The mean number of incisions was 3.24 and mean operative time per limb was 65.9 minutes. The mean hospitalization was 1.86 days. The varicose vein extraction using transilluminated powered phlebectomy(TIPP) is a safe, efficacious and cosmetically satisfactory method. The procedure decreases the operating time and the number of incisions required to remove varicose clusters. Further evaluation and long term follow up will be necessary to determine the recurrence rate and long termcomplications.to determine the recurrence rate and long termcomplications.

Environmental Contamination and Best Management of Stone-dust from Quarry Mine (석산개발에 따른 주변 환경오염 및 석분토 처리를 위한 연구)

  • Lee, Pyeong-Koo;Youm, Seung-Jun;Kang, Min-Ju
    • Economic and Environmental Geology
    • /
    • v.43 no.4
    • /
    • pp.315-332
    • /
    • 2010
  • All of the water and stone-dust samples with or without flocculant, in and around quarry mines, were analyzed for total concentrations of heavy metals, cyanide(CN), toxic organic compounds and organic phosphorus. Extraction experiments on stone-dust by EDTA and various pH solutions were also carried out, in order to evaluate the contaminant leaching from the long-term heaped stone-dust within quarry mines. The concentrations of $Cr^{6+}$, Hg, CN, TCE/PCE and total phosphorus in all samples (water and stone-dust) were under detection limits, confirming no environmental contamination from stone-dust in quarry mine areas. Lead and cadmium were not detected in all water samples. Copper and zinc were found in some water samples, and arsenic was detected in a few water samples. But they also showed levels much lower than the drinking water standard. Results of the extraction experiments by EDTA and pH solutions showed that Pb, Cr, Cd, Cu and Zn were leached out in less amounts or under detection limits. Arsenic was detected only at pH 3. From above results, we suggested that environmental contamination by quarry mine development is likely to be minor or negligible.

Validated HPLC Method for the Pharmacokinetic Study of Atenolol and Chlorthalidone Combination Therapy in Korean Subjects

  • Kang, Hyun-Ah;Kim, Hwan-Ho;Kim, Se-Mi;Yoon, Hwa;Cho, Hea-Young;Oh, Seaung-Youl;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.5
    • /
    • pp.331-338
    • /
    • 2006
  • A rapid, selective and sensitive reverse-phase HPLC methods for the determination of atenolol and chlorthalidone in human serum and whole blood were validated, and applied to the pharmacokinetic study of atenolol and chlorthalidone combination therapy. Atenolol and an internal standard, pindolol, were extracted from human serum by liquid-liquid extraction, and analyzed on a $\mu$-Bondapak C18 $10-{\mu}$ column in a mobile phase of methanol-0.01 M potassium dihydrogenphosphate(30:70, v/v, adjusted to pH 3.5) and fluorescence detection(emission: 300 nm, excitation: 224 nm). Chlorthalidone and an internal standard, probenecid, were extracted form human whole blood by liquid-liquid extraction, and analyzed on a Luna C18 $5-{\mu}$ column in a mobile phase of acetonitrile containing 77% 0.01 M sodium acetate and UV detection at 214 nm. These analysis were performed at three different laboratories using the same quality control(QC) samples. The chromatograms showed good resolution, sensitivity, and no interference by human serum and whole blood, respectively. The methods showed linear responses over a concentration range of 10-1,000 ng/mL for atenolol and 0.05-20 ${\mu}g/mL$ for chlorthalidone, with correlation coefficients of greater than 0.999 at all the three laboratories. Intra- and inter-day assay precision and accuracy fulfilled international requirements. Stability studies(freeze-thaw, short-, long-term, extracted sample and stock solution) showed that atenolol and chlorthalidone were stable. The lower limit of quantitation of atenolol and chlorthalidone were 10 ng/mL and 0.05 ${\mu}g/mL$, respectively, which was sensitive enough for pharmacokinetic studies. These methods were applied to the pharmacokinetic study of atenolol and chlorthalidone in human volunteers following a single oral administration of Hyundai $Tenoretic^{\circledR}$ tablet(atenolol 50 mg and chlorthalidone 12.5 mg) at three different laboratories.

Electrochemical Determination of Artemisinin in Artemisia annua L Herbal Tea Preparation and Optimization of Tea Making Approach (개똥쑥 약초차 제조에서 아르테미시닌의 전기화학적 측정과 차를 만드는 최적화로의 접근법)

  • Debnath, Chhanda;Dobernig, Andrea;Saha, Pijus;Ortner, Astrid
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.1
    • /
    • pp.57-62
    • /
    • 2011
  • Sometimes inhabitants in remote areas have inadequate or no access to modern medicines or medical services. They can get benefit in term of the treatment against malaria by cultivating selected breeding of A. annua and making teas or decoctions from the plant materials following the proper way of tea preparation. In order to have the maximum extraction efficiency for artemisinin, different ways of tea preparations of A. annua were investigated by applying the developed DPP method and described in this article. Tea was prepared by three different ways (cooking, without cooking with/without shaking and microwave oven) with different times. From the results, it has been found that higher concentration of artemisinin (84.7%) can be attained by following the approach for tea preparation without cooking with shaking for 15 minutes (R.S.D. 2.34%). The concentration of artemisinin decreases with cooking more than 1.5 min in microwave oven. The utmost extraction (88.9% of artemisinin) is possible to extract by shaking with boiled 5% ethanol in distilled water (R.S.D. 2.28%).

Retrospective Study of Wide-Diameter Implants in Maxillary & Mandibular Molar regions (상하악 대구치 부위에서 넓은 직경 임플란트의 생존율에 대한 후향적 연구)

  • Park, Kyung-Ah;Jeong, Cheol-Woong;Ryoo, Gyeong-Ho;Park, Kwang-Bum;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.825-838
    • /
    • 2007
  • Endosseous implants are used in the treatment of various types of tooth loss, and numerous long-term studies have demonstrated the excellent reliability of this method of treatment. However, the increase of implant failure are associated with inadequate quality and/or height of bone. At the end of the 1980s, Wide(>3.75mm) implants were initially used for managing these difficult bone situations. The recommended indications for its use included poor bone quality, inadequate bone height. immediate placement in fresh extraction sockets, and immediate replacement of failed implants. At the 2000s, wider implants(6.0mm and 6.5mm) were used in a few studies. Although good clinical outcomes have been reported in recent years, there is still a controversy on this topic. Therefore, the purpose of this study was to estimate the survival rate of wide implants($6.0{\sim}8.0mm$) in molar regions, evaluating the clinical outcome. In this study, 1135 RBM surfaced wide implants($Rescue^{TM}$, MEGAZEN Co., Korea/595 maxillary, 540 mandibular) were placed in 650 patients(403 male, 247 female/age mean: $51.2{\pm}11.1$ years, range 20 to 83 years). Of the total, 68.3% were used to treat fully or partially edentulous situations, including single-tooth losses and 31.7% were placed immediately after teeth extraction or removal of failed implants, of which all were in the molar regions. Implant diameter and length ranged from 6.0 to 8.0mm and from 5.0 to 10.0mm respectively. The implants were followed for up to 42 months (mean: $14.6{\pm}9.5$ months). Of 1135 placed implants, 58 implants were lost. Among them, 53 implants were lost within 12 months after implant placement. The survival rate was 93.6% in the maxilla and 96.3% in the mandible, yielding an overall survival rate of 94.9%, for up to 42 months. As the result of Cox regression model, prosthetic type, sinus graft, and patient gender have an statistical significance on the implant survival rate in this study. This study suggests that the use of wide implants($6.0{\sim}8.0mm$) would provide a predictable treatment alternative in posterior areas.

Analysis and Prediction of Trends for Future Education Reform Centering on the Keyword Extraction from the Research for the Last Two Decades (미래교육 혁신을 위한 트렌드 분석과 예측: 20년간의 문헌 연구 데이터를 기반으로 한 키워드 추출 분석을 중심으로)

  • Jho, Hunkoog
    • Journal of Science Education
    • /
    • v.45 no.2
    • /
    • pp.156-171
    • /
    • 2021
  • This study aims at investigating the characteristics of trends of future education over time though the literature review and examining the accuracy of the framework for forecasting future education proposed by the previous studies by comparing the outcomes between the literature review and media articles. Thus, this study collects the articles dealing with future education searched from the Web of Science and categorized them into four periods during the new millennium. The new articles from media were selected to find out the present of education so that we can figure out the appropriateness of the proposed framework to predict the future of education. Research findings reveal that gradual tendencies of topics could not be found except teacher education and they are diverse from characteristics of agents (students and teachers) to the curriculum and pedagogical strategies. On the other hand, the results of analysis on the media articles focuses more on the projects launched by the government and the immediate responses to the COVID-19, as well as educational technologies related to big data and artificial intelligence. It is surprising that only a few key words are occupied in the latest articles from the literature review and many of them have not been discussed before. This indicates that the predictive framework is not effective to establish the long-term plan for education due to the uncertainty of educational environment, and thus this study will give some implications for developing the model to forecast the future of education.