• 제목/요약/키워드: Tension band

검색결과 88건 처리시간 0.023초

Differentiation of Adductor-Type Spasmodic Dysphonia from Muscle Tension Dysphonia Using Spectrogram (스펙트로그램을 이용한 내전형 연축성 발성 장애와 근긴장성 발성 장애의 감별)

  • Noh, Seung Ho;Kim, So Yean;Cho, Jae Kyung;Lee, Sang Hyuk;Jin, Sung Min
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • 제28권2호
    • /
    • pp.100-105
    • /
    • 2017
  • Background and Objectives : Adductor type spasmodic dysphonia (ADSD) is neurogenic disorder and focal laryngeal dystonia, while muscle tension dysphonia (MTD) is caused by functional voice disorder. Both ADSD and MTD may be associated with excessive supraglottic contraction and compensation, resulting in a strained voice quality with spastic voice breaks. The aim of this study was to determine the utility of spectrogram analysis in the differentiation of ADSD from MTD. Materials and Methods : From 2015 through 2017, 17 patients of ADSD and 20 of MTD, underwent acoustic recording and phonatory function studies, were enrolled. Jitter (frequency perturbation), Shimmer (amplitude perturbation) were obtained using MDVP (Multi-dimensional Voice Program) and GRBAS scale was used for perceptual evaluation. The two speech therapist evaluated a wide band (11,250 Hz) spectrogram by blind test using 4 scales (0-3 point) for four spectral findings, abrupt voice breaks, irregular wide spaced vertical striations, well defined formants and high frequency spectral noise. Results : Jitter, Shimmer and GRBAS were not found different between two groups with no significant correlation (p>0.05). Abrupt voice breaks and irregular wide spaced vertical striations of ADSD were significantly higher than those of MTD with strong correlation (p<0.01). High frequency spectral noise of MTD were higher than those of ADSD with strong correlation (p<0.01). Well defined formants were not found different between two groups. Conclusion : The wide band spectrograms provided visual perceptual information can differentiate ADSD from MTD. Spectrogram analysis is a useful diagnostic tool for differentiating ADSD from MTD where perceptual analysis and clinical evaluation alone are insufficient.

  • PDF

Yield strength estimation of X65 and X70 steel pipe with relatively low t/D ratio

  • Kim, Jungho;Kang, Soo-Chang;Kim, Jin-Kook;Song, Junho
    • Steel and Composite Structures
    • /
    • 제38권2호
    • /
    • pp.151-164
    • /
    • 2021
  • During the pipe forming process, a steel plate undergoes inelastic behavior multiple times under a load condition repeating tension and compression in the circumferential direction. It derives local reduction or increase of yield strength within the thickness of steel pipes by the plastic hardening and Bauschinger effect. In this study, a combined hardening model is proposed to effectively predict variations of yield strength in the circumferential direction of API-X65 and X70 steel pipes with relatively low t/D ratio during the forming process, which is expected to experience accumulated plastic strain of 2~3%, the typical Lüder band range in a low-carbon steel. Cyclic tensile tests of API-X65 and X70 steels were performed, and the parameters of the proposed model for the steels were calibrated using the test results. Bending-flattening tests to simulate repeated tension and compression during pipe forming were followed for API-X65 and X70 steels, and the results were compared with those by the proposed model and Zou et al. (2016), in order to verify the process of material model calibration based on tension-compression cyclic test, and the accuracy of the proposed model. Finally, parametric analysis for the yield strength of the steel plate in the circumferential direction of UOE pipe was conducted to investigate the effects of t/D and expansion ratios after O-forming on the yield strength. The results confirmed that the model by Zou et al. (2016) underestimated the yield strength of steel pipe with relatively low t/D ratio, and the parametric analysis showed that the t/D and expansion ratio have a significant impact on the strength of steel pipe.

Fiber-Optic Directional Coupler Using HF Wet-Etching (플루오린화 수소산의 습식식각법을 이용한 광섬유형 방향성 결합기)

  • Son, Gyeongho;Jung, Youngho;Yu, Kyoungsik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제28권1호
    • /
    • pp.25-32
    • /
    • 2017
  • In this paper, a fabrication method of low-loss tapered optical fibers coupler using hydrofluoric acid with surface tension driven is proposed. The proposed fabrication method is very simple compared to flame-based method, and shows low excess insertion losses compared to polishing method. The adiabatic-tapered structure along the coupling region of the coupler shows wavelength independent characteristic over the C-band in optical communication system, and will enable promising applications.

New Tie-over Dressing Method Using Hooks and Rubber Bands (갈고리와 고무밴드를 이용한 새로운 봉합고정드레싱법)

  • Kim, Gook-Jin;Lee, Youn-Jung;Kim, Nam-Gyun;Kim, Jun-Sik;Lee, Kyung-Suk
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.552-554
    • /
    • 2011
  • Purpose: Though its general usage, traditional tie-over dressing using suture has a few drawbacks such as difficulty in re-fixation after its opening especially when hematoma or seroma has occurred. It is rather difficult to maintain a stable dressing on curvy parts of body like flank, buttocks and that leads to unsatisfactory results of the surgery. Authors recommend a quick and repeatedly doable method, tie-over dressing that incorporates the usage of hooks and rubber bands. Methods: Debridement was done at a recipient site to be able to do skin graft. A right size of skin graft was prepared and placed upon the defect site with suture. Enough number of hooks were attached using Blue nylon at the normal skin of the edge of grafted area. We Applied dressing with ointment and fluffy gauze then fixed the dressing by attaching a rubber band at the hook to give a certain amount of tension. One or two days after the surgery, we opened the tie-over dressing and repeated the tie-over dressing by reusing the hooks and rubber band. Results: The skin grafts were all successfully taken and by repeating tie-over dressing using hooks and rubber, we could take the advantage of shortened the dressing time and eliminate the inconvenience of the patient and the surgeon by using bandages and fixing tapes. Conclusion: The advantage of tie over dressing using hooks and rubber bsnds are its easy re-doability early detection of probable complications, preventability of reoccurence of hematoma and seroma. Therefore, authors report this as considering the tie-over dressing using hooks and rubber bands is recommendable.

A Study on the Efficient Tension Estimation of Cables under Ambient Vibration using Minimized Measurement and Signal Processing System (최소화된 계측 및 신호 처리 시스템을 이용한 상시진동 케이블의 효율적인 장력 추정에 관한 연구)

  • Lee, Hyeong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제19권11호
    • /
    • pp.594-603
    • /
    • 2018
  • Recently, according to the development of measurement techniques, it has become possible to take complicated and time-consuming field measurements in a simple and convenient manner. In this background, this study estimated the tension of cables under ambient vibration using minimized measurement and signal processing. The VBDM using video-only by low-cost equipment was used as a minimized measurement. An estimation of the natural frequency using the mirror frequency concept was also proposed to solve the shortage of frequency band in this case. Furthermore, the FDD method was adopted for a natural frequency estimation in the ambient vibration related to field application. Experimental studies using a cable-stayed bridge model were carried out to examine the properties of the mirror frequency and the applicability of FDD with the proposed minimized system. The results showed that FDD for ambient vibration also works properly in an estimation of the natural frequency using the minimized system. In addition, the mirror frequency concept can allow a high natural frequency estimation even in a distorted signal by low-speed recording, which can overcome the limit of the minimized system. Overall, the proposed minimized system can be effective for the tension estimations of a cable under ambient vibration.

CVT Power Transmitting Characteristics and Control Logics for Negative Torque (역방향 토크시 무단변속기 동력전달 특성과 제어로직)

  • 송한림;이희라;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제10권1호
    • /
    • pp.255-264
    • /
    • 2002
  • In this paper, the power transmitting mechanism for negative torque of the metal V-belt (MVB) CVT were investigated by theoretically analyzing variation of band tension, block compression forces for each of the primary and secondary pulleys. An experimental study was performed to investigate the speed ratio - thrust characteristics for negative torque. The experimental results are in good acoordance with the theoretical results. CVT line pressure control logic was suggested for negative torque based the speed radio - negative torque - thrust characteristics and the thrust ratio curves. The results of this study can be used as basic design materials for developing the CVT control system for negative torque.

Surgical Treatment of Proximal Tibial Physeal Fracture and Avulsion Fracture of Tibial Tuberosity in a Immature Dog (미성숙견에서 경골 근위성장판 골절 및 경골결절 결출성 골절의 외과적 치료)

  • 정순욱;이경리;최치봉;최혜정;임용규;김휘율;정병현
    • Journal of Veterinary Clinics
    • /
    • 제18권2호
    • /
    • pp.160-163
    • /
    • 2001
  • A 8 months old female dog with the combination of a fracture of the proximal tibia (Salter-Harris type I) with an avulsion of the tibial tuberosity was repaired with cross intramedullary pin for proximal tibial physeal fracture, and intramedullary pin combined with tension band wire for avulsion fracture of tibial tuberosity, resulted in complete healing. At 45 days after operation, on the radiological views, there was premature closure of growth plate of proximal tibia and tibial tuberosity, but at 7 months no developing growing deformities.

  • PDF

Power Transmission Characteristics and Speed Ratio-Torque Load-Axial Force Relationship for a Metal V-Belt CVT (금속 V-벨트 CVT의 동력전달 특성과 변속비-부하토크-축력 관계)

  • 김광원;김현수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제14권2호
    • /
    • pp.349-357
    • /
    • 1990
  • Power transmission characteristics and speed ratio-torque load-axial force relationship for a metal V-belt CVT were investigated theoretically and experimentally. In the metal V-belt CVT drive, it was found that the power was transmitted by thrust force and that band tension should be greater than compression force between the metal blocks. The experimental results for the speed ratio-torque load-axial force relationship showed good agreement with those predicted using equations developed from theoretical considerations.

Achilles Tendon Rupture Associated with Ipsilateral Bimalleolar Fracture (A Case Report) (아킬레스건 파열과 동반된 동측 족관절 양과 골절(1예 보고))

  • Chung, Hyung-Jin;Bae, Su-Young;Min, Byoung-Kwon;Song, Min-Cheol
    • Journal of Korean Foot and Ankle Society
    • /
    • 제15권2호
    • /
    • pp.107-109
    • /
    • 2011
  • We report here on a case of Achilles tendon rupture associated with ipsilateral bimalleolar fracture that was caused by ski injury. The association of an ankle fracture with rupture of the Achilles tendon is even more infrequent, although both injuries alone are extremely common. We treated as a operation of Achilles tendon repair with Krackow method and open reduction with Tension-band wiring technique for bimalleolar fracture.

A study on the HPHT-processed NOUV diamonds by means of their gemological and spectroscopic properties

  • Kim, Young-Chool;Choi, Hyun-Min
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • 제15권3호
    • /
    • pp.114-119
    • /
    • 2005
  • This study has been carried out with the eight HPHT processed NOUV diamonds - two yellow, two yellowish green, two green and two orangy yellow color stones. The gemological properties of these diamonds included a highly saturated body color, graphitized fractures around the girdles, tension cracks around crystalline inclusions, long-wave UV with medium yellowish green to a very strong yellowish green luminescence, and short-wave UV with faint yellowish green to a strong yellowish green luminescence. Distinctive features of spectroscopic properties include absorption peaks at 415 nm and 503 nm a strong absorption band at $460{\sim}480nm$ and a H2 center at 986nm. Infrared spectra showed an absorption peak at $1344cm^{-1}$ (C center), which is the characteristics related to single substitutional nitrogen.