• Title/Summary/Keyword: Tension

Search Result 6,859, Processing Time 0.038 seconds

Tethers tension force effect in the response of a squared tension leg platform subjected to ocean waves

  • El-gamal, Amr R.;Essa, Ashraf;Ismail, Ayman
    • Ocean Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.327-342
    • /
    • 2014
  • The tension leg platform (TLP) is one of the compliant structures which are generally used for deep water oil exploration. With respect to the horizontal degrees of freedom, it behaves like a floating structure moored by vertical tethers which are pretension due to the excess buoyancy of the platform, whereas with respect to the vertical degrees of freedom, it is stiff and resembles a fixed structure and is not allowed to float freely. In the current study, a numerical study for square TLP using modified Morison equation was carried out in the time domain with water particle kinematics using Airy's linear wave theory to investigate the effect of changing the tether tension force on the stiffness matrix of TLP's, the dynamic behavior of TLP's; and on the fatigue stresses in the cables. The effect was investigated for different parameters of the hydrodynamic forces such as wave periods, and wave heights. The numerical study takes into consideration the effect of coupling between various degrees of freedom. The stiffness of the TLP was derived from a combination of hydrostatic restoring forces and restoring forces due to cables. Nonlinear equation was solved using Newmark's beta integration method. Only uni-directional waves in the surge direction was considered in the analysis. It was found that for short wave periods (i.e., 10 sec.), the surge response consisted of small amplitude oscillations about a displaced position that is significantly dependent on tether tension force, wave height; whereas for longer wave periods, the surge response showed high amplitude oscillations that is significantly dependent on wave height, and that special attention should be given to tethers fatigue because of their high tensile static and dynamic stress.

The clinical manifestation of tension-type headache and correlation study with autonomic bioelectric response (긴장형(緊張型) 두통(頭痛)의 임상양상(臨床樣相) 및 생체전기 자율반응과의 상관성(相關性) 고찰(考察))

  • Choung, In-tae;Lee, Sang-hoon;Choi, Do-young
    • Journal of Acupuncture Research
    • /
    • v.21 no.2
    • /
    • pp.183-203
    • /
    • 2004
  • Objective : Tension-type headache is the most common headache. The objective of this study is to find the clinical manifestation of tension-type headache and correlation with autonomic bioelectric response. Methods : This observation was carried out on 60 patients with tension-type headache. We used headache questionnaire and the Autonomic Bioelectric Response recoder(ABR-2000) for this study. Results : 1. Distribution of sex & age : male : female=5 : 7, 50s&60s group (28.3%) 2. Duration of onset : over 5years(50%), over one years(83.4%) 3. Causes of illness : stress(58.3%), severe fatigue(53.5%), tension(33.3%) 4. Time of attack : irregular(56.7%), day time(16.7%) 5. Pattern of pain: heavy(31 people), stiffness of occipital region (27 people) tightening around the head(25 people) 6. Curve : 40%, 56.7%, 35.0% SL(Slope low) at peak 1, 2, 3/ SH&SI not found 7. Regulation : 16.7% RR(Regulation reverse) at peak 1, 25% RH(Regulation high) at peak 2, 15% RR(Regulation reverse) at peak 3 8. Graph : Activity-60.0%, 70.0%, 63.3% lowered reaction(L, LR, L!) at peak 1, 2, 3 Reactivity-83.3%, 95.0%, 93.3% lowered reaction at peak 1, 2, 3 Conclusion : We find tension-type headache has remarkable relativeness with autonomic bioelectric response.

  • PDF

Fracture Behaviour of Lubricants in ABS Terpolymer (ABS 중에 첨가된 저분자 화합물의 파단 거동에 미치는 영향)

  • Don, Yoon-Seung;Shim, Mi-Ja;Kim, Sang-Wook
    • Applied Chemistry for Engineering
    • /
    • v.5 no.5
    • /
    • pp.878-888
    • /
    • 1994
  • In order to investigate the fracture behavior of ABS terpolymer under the tension and impact load, varing the content of rubber, molecular weight of SAN, content and kinds of lubricant, tension speed, the mechanical properties were measured and SEM pictures of fracture area were taken. Under the tension, the tensile strength increased as rubber content and lubricant content decreased, while molecular weight and tension speed increased. The deformation of area near fracture site did not occur as rubber content, tension speed and molecular weight decreased and liquid lubricant was used. And in the shape of fracture seemed phase seperation. Under the impact load, the notched izod impact strength increased as rubber content, molecular weight, ambient temperature and lubricant content increased. In the SEM picture, the strength was high white the fracture surface was small.

  • PDF

An Experimental Study on the Block Shear Rupture of Angle Tension Members (인장력을 받는 ㄱ형강의 블록전단 파단에 관한 실험적 연구)

  • Kim, Bo Young;Lee, Kyu Kwong;Choi, Mun Sik
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.4 s.37
    • /
    • pp.721-730
    • /
    • 1998
  • In this paper, an experimental study have been many studies on the joints of steel structure, for it has great influences on the safety of structures. Research on block shear rupture of the joint receiving pure tension have been done in foreign countries, but not in Korea. This study focuses on the propriety of block shear design code, according to limited state design criteria of steel structures recently established in Korea, by an experiment on the joint of angle tension members. The methods of this study were to compare other study results on block shear rupture mode and ultimate capacity, and to evaluate the propriety of the criteria design code. The result is that tension yield shear ruptures and shear yield tension ruptures happened at the joint, and the experimental rupture load was 15% higher than the capacity entered in the criteria design code. We conclude that it is necessary to revaluate the block shear design code presented by many studies on the limited state design criteria of steel structures.

  • PDF

Structure of Opposite Wood in Angionsperms(I) - Structure of Opposite Woods in the Inclined Stem of Mature Woods - (활엽수(闊葉樹) Opposite재(材)의 구조(構造)(I) - 경사(傾斜) 생장(生長)한 성숙재(成熟材) 수간(樹幹)의 Opposite재(材) 구조(構造) -)

  • Park, Sang-Jin;Park, Byung-Soo;Soh, Won-Taek
    • Journal of the Korean Wood Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.1-12
    • /
    • 1989
  • To study the structure of opposite wood in the angiosperms. samples were cut from stems and branchs of 10 spcies growing in Korea. The opposite side was defined as being along a line passing from the most wide annual ring of the tension wood on the upper side to the pith and extrapolated through the opposite side. lateral sides being on the right and left of this line. The stem woods growing almost horizontally were surveyed the structural features of the well-developed opposite wood for the tension wood. In the annual-ring of the well-developed opposite woods. an investigation was made on how the dimension of elements, microfibril angles. and cell wall layers change from tension side to opposite side. The structural characteristics of opposite wood in hardwoods realized in this study are as follows: 1. The vessel diameters increased continuously to ward the opposite side in which the values were maximum. The vessel length also increased toward opposite side. but the rates of increase were smaller than those in the vessel diameters. 2. The wood fiber length were decreased from tension toward opposite side. but the rates of decrement were f1actuated within the sampled species. 3. The microfibril angles had the minimum values on the tension side. then increased steeply toward the opposite side in which the values maximum. 4. In the percentage of elements the vessel elements increased continously at a relative rate from the tension to opposite side, whereas the values of the wood fibers were lower in the opposite than the tension side, but the' variation patterns of rays were not seem distinctly. 5. The component layers of the wood fiber in the opposite woods were very similar to the lateral woods.

  • PDF

Symptom Checklist-90-Revision(SCL-90-R) in Inpatients on Tension headache and Insomnia (긴장성 두통 및 불면을 주소로 입원한 환자의 간이정신진단검사(SCL-90-R)의 진단별 특성)

  • Shim, Sang-Min;Koo, Byung-Soo;Kim, Kyeong-Ok
    • Journal of Oriental Neuropsychiatry
    • /
    • v.14 no.1
    • /
    • pp.117-131
    • /
    • 2003
  • SCL-90-R is a multidimensional self-report symptom inventory devoloped by Derogatis and his coworkers. Since it was standardized into Korean version in 1978 by Won and Kim et aI., but it has been rarely studies for the clinical groups. Objectives : This study sought to define a diagnotic character of SCL-90-R of tension headache and insomnia inpatients groups. Methods : We determined a diagnotic character of 17 tension headache and 23 insomnia patients by means of SCL-90-R, and compared with normal groups in order to characterize subscale of SCL-90-R in patients with tension headache and insomnia from Neurasthenia. Results : 1. Male tension headache group has significant difference in Somatization and Depression subscales, female group in Somatization, Obsessive-Compulsive, Depression and Hostility subscales. 2. Female insomnia group has significant difference in Anxiety subscale. Although there are a little significiant, many subscales such as Somatization, Obsessive-Compulsive, Depression and Hostility are higher than normal group. 3. There are significant difference in GSI and PDSI of Global index, which means that we use that for objective index of tension headache and insomnia from Neurasthenia. Conclusions : All of these results show that SCL-90-R is useful inventory to characterize and screening for Neurasthenia.

  • PDF

Scheme and Movement/Tension Control of Working Robot for the Installation of an Overhead Power Cable (1) (전력케이블 가설용 작업로봇의 구성과 이동/장력 혼합제어에 관한 연구(1))

  • Choi, Dong Soo;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.28-34
    • /
    • 2016
  • When a electric power cable is installed in the air for newly or exchanged working, it is necessary at all time to hold a constant tension for an overhead power cable. And also a pendanted power cable is an extreme job to have work in a high sky. For this reason, the objective of this paper developments working robot for preventing disaster that tension of cable installed automatically power cable to hold a constant. So the working robot works at all the time two tasks for mobil and tension it come into a inference between two tasks, control is difficult. Control methode needs to suppress inference of two tasks. In this paper, for installation of overhead power cable, the scheme and control methode of working robot is presented. the robot work at a same time tow tasks that have hold a constant tension of the power cable and move a constant place while unfasten a winding cable at a drum on a chassis. Working robot consist of three parts with mobile system, tension system and control part. As it is applied the feedback/feedforward control, methode of hybrid control is established to suppress that interference come into between two tasks. The simulation programs is made out using models of mobil and tension system, and a proposed controllers. In accordance with simulation, the model of each systems is discussed to make out proper. And also parameters of controllers is selected a suitable value and the driving performance of robot is evaluated.

Modelling of tension-stiffening in bending RC elements based on equivalent stiffness of the rebar

  • Torres, Lluis;Barris, Cristina;Kaklauskas, Gintaris;Gribniak, Viktor
    • Structural Engineering and Mechanics
    • /
    • v.53 no.5
    • /
    • pp.997-1016
    • /
    • 2015
  • The contribution of tensioned concrete between cracks (tension-stiffening) cannot be ignored when analysing deformation of reinforced concrete elements. The tension-stiffening effect is crucial when it comes to adequately estimating the load-deformation response of steel reinforced concrete and the more recently appeared fibre reinforced polymer (FRP) reinforced concrete. This paper presents a unified methodology for numerical modelling of the tension-stiffening effect in steel as well as FRP reinforced flexural members using the concept of equivalent deformation modulus and the smeared crack approach to obtain a modified stress-strain relation of the reinforcement. A closed-form solution for the equivalent secant modulus of deformation of the tensioned reinforcement is proposed for rectangular sections taking the Eurocode 2 curvature prediction technique as the reference. Using equations based on general principles of structural mechanics, the main influencing parameters are obtained. It is found that the ratio between the equivalent stiffness and the initial stiffness basically depends on the product of the modular ratio and reinforcement ratio ($n{\rho}$), the effective-to-total depth ratio (d/h), and the level of loading. The proposed methodology is adequate for numerical modelling of tension-stiffening for different FRP and steel reinforcement, under both service and ultimate conditions. Comparison of the predicted and experimental data obtained by the authors indicates that the proposed methodology is capable to adequately model the tension-stiffening effect in beams reinforced with FRP or steel bars within wide range of loading.

An Experimental Study on the Static Load Capacity of T-Type Tension Joints with High Tension Bolt (고장력볼트 T-인장이음의 정적내력에 관한 실험적 연구)

  • Lee, Seung Yong;Choi, Jun Hyeok;Kim, Kyong Tae
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • The tension type joint is a mechanically very efficient connection method, as it directly uses the load capacity of base metal or high tension bolt, the reduction of the number of drilling hole and fastening and the fatigue resistance. It is applied to the joint of girder and cross beam, horizontal joints of towers, beam to column joints, the secondary member joints of deck floor ends, and brackets. In this paper, static load tests for the T-type tension joint were conducted to investigate the structural behavior of the joint. The parameters were bolt diameter, flange thickness, and the reduction of clamping force of the joint. The failure modes and load capacity of joints and the effects of flange thickness, bolt diameter and clamping force were investigated.

Ultimate behavior of RC hyperbolic paraboloid saddle shell

  • Min, Chang-Shik
    • Structural Engineering and Mechanics
    • /
    • v.5 no.5
    • /
    • pp.507-521
    • /
    • 1997
  • The ultimate behavior of a reinforced concrete hyperbolic paraboloid saddle shell under uniformly distributed vertical load is investigated using an inelastic, large displacement finite-element program originally developed at North Carolina State University. Unlike with the author's previous study which shows that the saddle shell possesses a tremendous capacity to redistribute the stresses, introducing tension stiffening in the model the cracks developed are no longer through cracks and formed as primarily bending cracks. Even though with small tension stiffening effect, the behavior of the shell is changed markedly from the one without tension stiffening effect. The load-deflection curves are straight and the slope of the curves is quite steep and remains unchanged with varying the tension stiffening parameters. The failure of the shell took place quite suddenly in a cantilever mode initiated by a formation of yield lines in a direction parallel to the support-to-support diagonal. The higher the tension stiffening parameters the higher is the ultimate load. The present study shows that the ultimate behavior of the shell primarily depends on the concrete tensile characteristics, such as tensile strength (before cracking) and the effective tension stiffening (after cracking). As the concrete characteristics would vary over the life of the shell, a degree of uncertainty is involved in deciding a specified ultimate strength of the saddle shell studied. By the present study, however, the overload factors based on ACI 318-95 are larger than unity for all the cases studied except that the tension stiffening parameter is weak by 3 with and without the large displacement effect, which shows that the Lin-Scordelis saddle shell studied here is at least safe.