• 제목/요약/키워드: Tension

검색결과 6,859건 처리시간 0.04초

장력제어를 위한 게인 스케줄링 (Gain Scheduling for Tension Control)

  • 이동욱;박성한;안병준;이만형
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.505-509
    • /
    • 2002
  • The looper control of hot strip finishing mill is one of the most important control item In hot strip rolling mill process. Loopers are placed between finishing mill stands and control the mass flow of the two stands. Another important action of the looper is to control the strip tension which influences on the width of the strip. So it is very important to control both the looper angle and the strip tension simultaneously but the looper angle and the strip tension are strongly interacted by each other. The gain scheduling is to break the control design process into two steps. First, one designs local linear controllers based on linerizations of the nonlinear system at several different operating conditions. Second, a global nonlinear controller for the nonlinear system is obtained by interpolating.

  • PDF

비선형 웹 이송 시스템의 장력 제어 (Tension Control in a Nonlinear Web Transfer System)

  • 윤석찬
    • 한국생산제조학회지
    • /
    • 제9권5호
    • /
    • pp.65-72
    • /
    • 2000
  • This paper presents the study of the tension control in a web transfer system. In this study the sliding mode controller is applied to a time-varying nonlinear mathematical model. The model was derived to consider the effects of changing the roll radius in tension variation during winding and unwinding. The uncertainty in modeling may be due to unmodelled dynamics, on variations in system model. Designed sliding mode controller made the system error always staying in the suggested surface from the beginning. Through this, system is maintained to be robust against a disturbance and uncertainty. To verify the designed controller has a good performance, various inputs such as desired velocity, step input, and trapezoidal input are applied. When the sliding mode controller was used, the system(the tension control) performance was improved comparing to the PID controller. The robustness of the controller with respect to an estimation error was verified through simulations.

  • PDF

직기 특성이 PET직물 물성에 미치는 영향(I) (Effects of Weaving Machine Characteristics on the Physical Properties of PET Fabrics (I))

  • 김승진;손준혁;강지만;박명환
    • 한국염색가공학회지
    • /
    • 제16권4호
    • /
    • pp.26-35
    • /
    • 2004
  • This study surveys the tension differences between Korean domestic and foreign looms and analyses fabric mechanical properties due to warp and weft tension differences using KES-FB system. Paper is divided by two parts. In this 1st paper, fabric is designed as 5 harness satin weave using 75d/36f warp and 100d/192f weft polyester filaments, and is woven by $Omega^\circledR$ rapier loom by Textec Co.Ltd and Picanol$-GTX^\circledR$ rapier loom by Picanol Co.Ltd respectively. These grey fabrics are processed on the same dyeing and finishing processes. Weavability is also analysed by measuring warp tension variation according to the warp position, the relationship between shed amount and the warp tension on one fixed heald frame is surveyed, and the relationship between end breaks and warp and weft tensions is also discussed.

열간 사상압연 공정의 장력제어 (Tension Control of Hot Strip Finishing Mill)

  • 이동욱;안병준;배종일;이만형
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.322-325
    • /
    • 2002
  • We describe the looper controller design for a hot strip mill. The looper is to control the strip tension which influences on the width of the strip. It is very important to control the looper control of the hot strip mill, but difficult to control the looper, because there exists on mutual interaction among strip gauge, looper angle, and strip tension. In this paper, we present the modeling for the hot strip finishing mill to control the tension of the strip and suggest a cross control method. The cross control is a very simple method that allows non-interacting control.

  • PDF

스크린 망사의 견장과 오프닝의 변화 (The Opening Size Change for Screen Tension)

  • 정기영;강영립
    • 한국인쇄학회지
    • /
    • 제28권1호
    • /
    • pp.43-50
    • /
    • 2010
  • The 200mesh screen was tensioned and fixed on a frame. When applied tension to 5N and 10N per unit area, a side length of opening of the screen was 163.223${\mu}m$ and 168.224${\mu}m$, respective. But side length not tensioned was 158.879${\mu}m$. We knew that a side length of opening of the screen rarely changes with tension applied to the screen. The appearances that a side length of opening of the screen expand little are due to a decreasing diameter of thread by means of tension. In a thickness measurement of screen, While the high density mesh screen that had a lot of knots that crossed a line of latitude and longitude per unit area appeared a higher numerical value, the low density mesh screen that had a few knots appeared a low numerical value.

TENSION LEVELLER 상태감시 및 진단시스템 개발 (Development of Tension Leveller Condition Monitoring and Diagnosis System)

  • 신남호;김수광;최석욱
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.350-354
    • /
    • 1995
  • The Tension Leveller of Cold Rolling Mill In POSCO performs levelling the strip in high speed line. But minor variations in operating condition of driving machines such as motor, gear box, and support bearings, a small gap-variation of supporter and strip slip by poor roll revolutions can cause serious problems in the quality of strip. In this study, firstly, A condition monitoring standard for each sensor is made through with the detail analysis of vibration and strip slip. Secondly, An automatic monitoring and diagnosing system was developed to monitor the condition of Tension Leveller, and diagnose the cause of abnormal condition. Finally, A diagnosing algorithm for abnormal condition and man-machine interface (MMI) for easy operation are developed.

  • PDF

인장법에 의한 고점도 잉크의 표면장력 측정법 (II) (The Elongation Method for the Measuring Surface Tension of High Viscosity Printing Ink (II))

  • 하영백;윤종태;구철회
    • 한국인쇄학회지
    • /
    • 제22권2호
    • /
    • pp.23-36
    • /
    • 2004
  • The surface tension method has been possible only for the low viscosity materials. However, the inks for the off-set lithography and intaglio should have high viscosity and high tack. In this paper, we propose the elongation method to estimate the surface tension of high viscosity printing inks. The elongation method could be more useful to estimate the surface tension and shown in this research, it is possible to calculate the surface tension of high viscoxity ink without diluting the sample.

  • PDF

상시하중상태에서 박벽의 보강효과에 대한 연구 (Reinforcing Effect of Thin-wall at Serviceability Condition)

  • 김두환;윤성수;박진선
    • 한국농공학회논문집
    • /
    • 제52권2호
    • /
    • pp.11-17
    • /
    • 2010
  • For the reasonable analysis of design problems for agricultural facilities, considered the reinforcing effect of thin-wall. The most of agricultural structure is constructed small scale and have many purposes. Thus it has been designed temporary rather than permanent structure, and has relatively large slenderness ratio, small section and semi-rigid condition. Therefore many agricultural facilities are consist of relatively strong frame with weak wall at the viewpoint of stiffness and have not been reflected in the design. But the tension field influences to collapse of structure have already known. Therefore, we need quantification the effect of tension field at structural analysis. In this study, present the method of quantification the effect of tension field that came out thin-plate surrounded by high stiffness frame. The numerical results show that the effect of tension field effect for thin-wall is about 5% of the sectional area of frame in study agricultural facilities.

Purification and Characterization of Biosurfactant from Tsukamurella sp. 26A

  • Choi, Kyung-Suk;Kim, Soon-Han;Lee, Tae-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • 제9권1호
    • /
    • pp.32-38
    • /
    • 1999
  • A biosurfactant produced by Tsukamurella sp. 26A was purified by procedures including acid precipitation, ethylacetate extraction, and adsorption chromatography. The purified biosurfactant reduced the surface tension of water from 72 mN/m to 30 mN/m at a concentration of 250 mg/l, whereas the minimum interfacial tension against n-hexadecane was lowered to 1.5 mN/m at a concentration of 40 mg/i. The compound stabilized oil-in-water emulsions with a variety of commercial oils and had strong emulsification and stabilization activities when compared to those of commercial emulsifiers and stabilizers. Surface tension was stable over a broad range of pH (2-12) and temperature ($100^{\circ}C$, 3h). The biosurfactant was identified as glycolipid having a hydrophilic moiety of trehalose.

  • PDF

고출력 레이저 치료를 통한 근강직 완화의 실시간 모니터링 연구 (Development of Real-time Monitoring System for Muscle Tension by High Intensity Laser Therapy)

  • 홍정선;윤종인
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권3호
    • /
    • pp.128-134
    • /
    • 2012
  • Currently, high-intensity laser therapy (HILT) is increasingly used in various muscle disorders like muscle tension. Our proposed study includes the development of the real-time monitoring system using a myotonometer for HILT. The developed system consists of a piezoelectric sensor and laser distance sensor for muscle stiffness monitoring during the treatments. The results demonstrated that the level of muscle tension was rapidly decreased after 3 minutes of the high-intensity laser treatment when compared to the control group. The combined HILT and realtime muscle tension monitoring system may help to evaluate the therapeutic procedure and efficient treatments for various muscle pains.