• Title/Summary/Keyword: Tendons

Search Result 527, Processing Time 0.031 seconds

Allowable Compressive Stress of Pre-Tensioned Members with Tee or Inverted Tee Sections at Transfer (T형 및 역T형 단면을 가지는 프리텐션부재의 프리스트레스 도입시 허용 압축응력)

  • Lee, Deuck-Hang;Lee, Jeong-Yeon;Lim, Joo-Hyuk;Kim, Kang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.353-364
    • /
    • 2011
  • In a previous research performed by the authors, the allowable compressive stress coefficient (K) in pretensioned members with rectangular section at transfer was proposed based on strength design theory. In this study, a subsequent research of an enormous analysis was performed to determine the K factor for Tee and inverted Tee section members, considering the effect of section height (h), section type, amount of tendons ($A_{ps}$), and eccentricity ratio (e/h). Based on the analysis results, the allowable compressive stress coefficients (K) for Tee and inverted Tee section members at transfer were derived, which limit the maximum allowable stresses as 80% and 70% of the compressive strengths at the time of release for Tee section and inverted Tee section, respectively. And these were larger than the allowable stresses specified in domestic and other international codes. In order to verify the proposed equations, they were compared to the test results available in literature and other codes, which showed that the allowable stresses in domestic and international codes are unconservative for the cases with low eccentricity ratios while conservative for those with high eccentricity ratios. The proposed equations, however, estimate the allowable stresses of the Tee and inverted Tee section members reasonably close to test results.

The Structural Integrity Test for a PSC Containment with Unbonded Tendons and Numerical Analysis II (비부착텐던 PSC 격납건물에 대한 구조건전성시험 및 수치해석 II)

  • Noh, Sanghoon;Jung, Raeyoung;Lee, Byungsoo;Lim, Sang-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.5
    • /
    • pp.535-542
    • /
    • 2015
  • A reactor containment acts as a final barrier to prevent leakage of radioactive material due to the possible reactor accidents into external environment. Because of the functional importance of the containment building, the SIT(Structural Integrity Test) for containments shall be performed to evaluate the structural acceptability and demonstrate the quality of construction. In this paper, numerical analyses are presented, which simulate the results obtained from the SIT for a prestressed concrete(PSC) structure. A sophisticate structural analysis model is developed to simulate the structural behavior during the SIT properly based on various preliminary analysis results considering contact condition among structural elements. From the comparison of the analysis and test results based on the acceptance criteria of ASME CC-6000, it can be concluded that the construction quality of the containment has been well maintained and the acceptable performance of new design features has been verified.

Comparison of Efficiency of Self-renewal and Differentiation Potential in Tendon-derived Mesenchymal Stem Cells Isolated by Magnetic-activated Cell Sorting Method or Colony Picking Method (자기 활성 세포 분리법과 군체 분리법으로 분리된 건 줄기세포의 자가 재생 능력 및 분화능 효율 비교)

  • Lee, Moses;Choi, Yoorim;Yoon, Dong Suk;Lee, Jin Woo;Yoon, Gil Sung;Choi, Woo Jin;Han, Seung Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.3
    • /
    • pp.100-107
    • /
    • 2014
  • Purpose: The purpose of this study is to evaluate the efficacy of mesenchymal stem cell (MSC) isolation by the magnetic-activated cell sorting (MACS) method in tendon tissue-derived cells compared to the colony picking method for isolation of MSCs by picking colony-forming cells. Materials and Methods: Human tendon-derived cells were isolated by enzyme digestion using normal tendon tissues from three donors. We used the magnetic kit and well-known MSC markers (CD90 or CD105) to isolate MSCs in tendon-derived cells using MACS. Cloning cylinders were used to isolate colony-forming cells having MSC characteristics in tendon-derived cells. Colony-forming unit-fibroblast (CFU-F) assay was used to evaluate the self-renewal capacity of cells isolated using the colony picking method or MACS. For comparison of differentiation potentials into osteogenic or adipogenic lineage between two groups, alizarin red S and oil red O staining were performed at 14 days after induction of differentiation in vitro. Results: Flow cytometry results showed that early passage tendon-derived cells expressed CD44 in 99.13%, CD90 in 56.51%, and CD105 in 86.19%. In the CFU-F assay, CD90+ or CD105+ cells isolated with MACS showed larger colony formation in size than cells isolated using the colony picking method. We also observed that CD90+ or CD105+ cells were constantly differentiated into both osteogenic and adipogenic lineages in cells from all donors, whereas cells isolated using the colony picking method were heterogeneous in differentiation potentials to the osteogenic and adipogenic lineages. Conclusion: CD90+ or CD105+ cells isolated using MACS showed superior MSC characteristics in the self-renewal and multi-differentiation capacities compared with cells isolated using the colony picking method.

Changes in Matrix Metalloproteinase and Tissue Inhibitors of Metalloproteinase in Patients with Rotator Cuff Tears

  • Kwon, Oh-Soo;Kim, Young-Yul;Ha, Ji Yoon;Kang, Han Bit
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.2
    • /
    • pp.64-67
    • /
    • 2014
  • Background: The purpose of this study was to determine whether in patients with rotator cuff tears a correlation exists between molecular changes and clinical parameters such as age, duration of symptom, range of motion, and tear size. Molecular changes of matrix metalloproteinase (MMP) and tissue inhibitor of metalloproteinase (TIMP) were assessed by measuring messenger RNA (mRNA) levels of the two proteins. Methods: The rotator cuff tissue from was obtained from the edge of a torn tendon revealed after debridement by a motorized shaver. Using the sample of rotator cuff tissue, the reverse transcription polymerase chain reaction was performed to quantify MMP-2 and TIMP-2 mRNA expression. To determine whether mRNA levels and the clinical variables, such as age, defect size, range of motion (ROM) of shoulder, and duration of symptoms, show any correlation, Spearman's correlation coefficients were used to test for significant differences. Results: There was an inverse correlation between the mRNA levels of MMP-2 and TIMP-2 from the torn rotator cuff tendons regardless of the clinical variables. However, comparison of mRNA levels versus clinical parameters such as age, defect size, range of motion and duration of symptoms revealed a number of findings. We found a significant correlation between age and mRNA levels of MMP-2 from torn cuffs (r = 0.513, p = 0.021). Further, we found a significant correlation between defect size in the full thickness tears and mRNA levels of MMP-2 (r = 0.454, p = 0.045). Conversely, no significant association between mRNA levels of MMP-2 and ROM or duration of symptom was found. Conclusions: Our results suggest that both MMP-2 and TIMP-2 may be involved in the disease process of rotator cuff tears. Although the level of mRNA expression of MMP-2 and TMP-2 remain constant in torn rotator cuffs irrespective of the clinical variables, their levels may be influenced by age and defect size, which could account to change in tendon degradation and the healing process.

A Review on Selection of Specific Points -Needling Depth of LU7 and Point Location of BL62 & KI6- (특정혈 취혈법에 대한 고찰 -LU7의 자침 깊이와 BL62 KI6 혈위를 중심으로-)

  • Keum, Yujeong;Lim, Hyanggi;Choi, Seoyeoung;Jung, Jihun;Eom, Dongmyung;Song, Jichung
    • Korean Journal of Acupuncture
    • /
    • v.37 no.1
    • /
    • pp.31-36
    • /
    • 2020
  • Objectives : The purpose of this study is to review needling depth and location of LU7, BL62 and KI6 by the medical classics' records. Methods : 1. We researched the medical classics describing LU7, KI6 and BL62, and reorganized data about the location and needling depth. 2. We compared the medical classics' records on LU7, KI6 and BL62 with description of WHO standard acupuncture point location. 3. We reviewed different location and needling depth of LU7, BL62, and KI6 recorded in the medical classics with the anatomical structure. Results : 1. The common needling depth of LU7 is about 0.2 chon. But in some medical classics, the depth of LU7 is 0.8 chon. Needling depth of LU7 varied depending on the patient's hand posture. In the 'half-up' position with the thumb upward, it is possible to stimulate acupuncture on LU7 by 0.8 chon because there is a space between the tendons. 2. In WHO standard acupuncture point location, the locations of BL62 and KI6 are just below the lateral and medial malleolus. But in some medical classics, the locations of BL62 and KI6 are between the bones and muscles below the malleolus. In the locations between the bones and muscles below the malleolus, it is possible to stimulate acupuncture on BL62 and KI6 by penetrating acupuncture because there is no bone structure. Conclusions : 1. By the 'half-up' position with the thumb upward, it is possible to stimulate vertically acupuncture on LU7 by 0.8 chon. 2. By the locations of BL62 and KI6 between the bones and muscles below the malleolus, it is possible to stimulate on BL62 and KI6 by penetrating acupuncture.

Tensile Stress Measurement of Tendon by Means of Non-contact Yoke Method (Yoke를 사용한 비접촉 방법에 의한 텐던 인장응력 측정)

  • Kang, Sunju;Son, Derac;Joh, Changbin;Lee, Jungwoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.1
    • /
    • pp.19-23
    • /
    • 2016
  • In this study, we have constructed a measuring system to investigate tensile stress measurement of tendons, which is employed in bridges, by means of the non-destructive and non-contact method. The measuring system consists of tensile stress applying apparatus up to 2 GPa, and power supply for ac and dc current to tendon directly to magnetize tendon in circular direction and to coil wound on yoke to magnetize tendon in axial direction. We have used two kinds of tendon, which were produced by different companies, using the measuring system constructed in this work. Two kinds of experiments are carried out in this work; $1^{st}$ experiment : ac current was applied to the tendon and dc current was applied to coil wound on the yoke, and voltage induced from search coil wound on yoke (SCY) was measured and $2^{nd}$ experiment : dc current was applied to the tendon and ac current was applied to coil wound on the yoke, and voltage induced from search coil on tendon (SCT) was measured. In case of $1^{st}$ experiment, voltage induced from SCY was changed below 200MPa tensile stress but the voltage was not increased above 200 MPa. In case of $2^{nd}$ experiment, voltage induced from SCT was decreased up to 1.5 GPa linearly. We expect that $2^{nd}$ experiment could be applied to the non-destructive testing of tensile stress measurement of tendon.

Outcome of Suture Suspension Arthroplasty for Thumb Carpometacarpal Joint Arthritis (무지 수근중수 관절염에 대한 현수 봉합 관절성형술의 결과)

  • Kim, Sehun;Gong, Hyun Sik;Lee, Se Yeon;Lee, Minho;Kim, Jihyeung;Baek, Goo Hyun
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.223-229
    • /
    • 2018
  • Purpose: A number of procedures were introduced to stabilize the 1st metacarpal bone after resection of the trapezium in the thumb carpometacarpal joint (CMCJ) arthroplasty. However, some surgical procedures may inevitably damage normal structures, such as harvesting tendons or drilling of a bone for tendon passage. Suture suspension arthroplasty is relatively less invasive and easier to perform than the previously described surgical methods. The purpose of this study was to report the therapeutic efficiency of the suture suspension arthroplasty. Methods: We retrospectively reviewed 12 patients who underwent suture suspension arthroplasty for the treatment of thumb CMCJ arthritis. Pain visual analogue scale (VAS), satisfaction about surgical outcomes, and the disabilities of the arm, shoulder and hand (DASH) scores were measured to evaluate the functional outcomes and the Trapezial Space Ratios were measured. Satisfaction was measured in the range of "very dissatisfied" (0) to "very satisfied" (10). Results: The mean follow-up period was 23 months. Pain VAS score improved significantly from 7.0 to 2.9 (p<0.05). And mean satisfaction scale was 6.9. However, there was no significant difference in DASH scores between before and after surgery (p=0.06). The mean trapezial space ratio was calculated to be 0.45 before surgery, 0.33 immediately after surgery, 0.23 at the last follow-up. Conclusion: Suture suspension arthroplasty is a satisfactory surgical procedure. And compared with other procedures, there is no significant difference in the reduction of the trapezial space. It may be useful in advanced thumb CMCJ arthritis.

Experimental Study on the Fire Performance of PC Slab by the Bearing Length (걸침길이에 따른 PC 슬래브의 화재성능에 관한 실험적 연구)

  • Park, Siyoung;Kang, Thomas H.K.;Lee, Ho-Wook;Gwak, Si-Young;Park, Jun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.14-22
    • /
    • 2022
  • In this study, a fire test was conducted to evaluate the fire performance of precast concrete (PC) slabs in an outdoor environment in response to the increase in fire incidents caused by the growth of warehouses. Prior to the field fire test, the tensile yield strength of the tendon at elevated temperatures was tested to analyze the mechanical properties. Also, by referring to previous studies, the thermal properties of tendon and the mechanical and thermal properties of concrete were investigated. A field fire test was conducted to analyze the structural and fire performance of two identical slabs with 50 and 150 mm bearing length. As the bearing length increased, deflection and horizontal displacement decreased. The fire test lasted for 200 minutes without the collapse of slabs, validating current codes. Based on the structural performance which maintained even with concrete spalling and rupture of some tendons, the bonded method is assumed to be practical in pre-tensioned PC slabs. The results of fire test are expected to be utilized in evaluating the fire performance of PC slabs in warehouses.

Evaluation of Bursting Behavior in Anchorage Zone of PSC I Girders (PSC I 거더의 정착부 파열거동 평가)

  • Choi, Kyu Chon;Park, Young Ha;Paik, In Yeol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.329-336
    • /
    • 2010
  • An experimental study to evaluate bursting behavior in anchorage zone of the standard PSC I girders (span length : 30 m) has been carried out. The arrangement of bursting reinforcement in anchorage zone of the standard PSC I girders is considered to be designed without accurately reflecting the stress flows in the end zone of the PSC I girders caused by presstressing forces of the tendons. Also, due to excessive arrangement of the bursting bars, the workability of the girder is decreased greatly. In this study, three specimens with the same dimensions as the end zone of the standard PSC I girder are prepared and the experiment is carried out by applying PS forces. The bursting reinforcement of each specimen consists of 100 mm, 200 mm, and 300mm spacings, respectively. The experimental results show that the range of the PS forces to cause crack in the anchorage zone of the specimen are more than 1.6 times of the design PS forces. The bursting cracks occur in the vertical direction on the inside of all specimens. After applying 2.7 times of the design PS force, some of the transverse bursting reinforcements only in the specimen reinforced by 300 mm spacing yielded. The experimental results show that the anchorage zone of the standard PSC I girders arranged by 300 mm spacing of the bursting reinforcements which is the maximum spacing allowed in the road bridge design specifications, can be considered safe enough.

A Study on the Prediction of Ultimate Stress of Tendon in Unbonded Prestressed Concrete Beams without Slip (비부착 PSC 보에서 슬립이 없는 강선의 극한 응력 예측에 관한 연구)

  • Hong, Sung-Su;Yoo, Sung-Won;Park, Seung-Bum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.537-548
    • /
    • 2008
  • Recently, the prestressed unbonded concrete structures are increasingly being built. The mechanical behavior of prestressed concrete beams with unbonded tendon is different from that of normal bonded PSC beams in that the increment of tendon stress was derived by whole member behavior. The purpose of the present paper is therefore to evaluate the flexural behavior and to propose the equation of ultimate tendon stress by performing static flexural test according to span/depth, concrete compression strength, reinforcement ratio and the effect of existing bonded tendon. From experimental results, for cracking, yielding and ultimate load, the effect of reinforcement ratio was more effective than concrete compression strength, and the beams having high strength concrete had a good performance than having low concrete, but there was no difference between high strength and low strength. And as L/dp was larger, test beams had a long region of ductility. This means that unbonded tendon has a large contribution after reinforcement yielding. Especially, the equation of ACI-318 was not match with test results and had no correlations. After analysis of test results, the equation of ultimate unbonded tendon stress without slip was proposed, and the proposed equation was well matched with test results. So the proposed equation in this paper will be a effective basis for the evaluation of unbonded tendons without slip, analysis and design.