• Title/Summary/Keyword: Tendon graft

Search Result 143, Processing Time 0.017 seconds

New Technique for the Reconstruction of Both Anteromedial & Posterolateral Bundles of ACL (전방십자인대의 전내측 다발 및 후외측 다발을 각각 재건하는 새로운 수술 수기)

  • Ha Chul-Won;Awe Soo-Ik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.195-199
    • /
    • 2002
  • This article is to report a new technique for reconstruction of the anteromedial and posterolateral bundles of anterior cruciate ligament by separate tensioning and fixation of the each bundle. Method : Tibial and femoral tunnels were made with conventional technique of anterior cruciate ligament reconstruction. Tibial tunnel was enlarged $5\~7$ mm in anterior-posterior direction to make oval it in cross section. When preparing the Achilles tendon allograft, bone plug portion was trimmed as the conventional technique. The tendinous portion was trimmed as two separate bundles by dividing the tendinous portion longitudinally, so the graft is shaped like 'Y'. The bone plug portion of allograft was inserted into the femoral tunnel and fixed with absorbable cross pins. Two ligamentous portionss of the distal part of the grafts were tensioned separately at the external orifice. Anteromedial bundle was fastened under maximum tension with the knee flexed 90 degrees by post-tie method. The posterolateral bundle was fixed by the same technique with the knee in full extension. Then, an absorbable interference screw was inserted between the two bundles upto the upper end of the tibial tunnel, to get more initial rigidity of the reconstructed graft as well as to locate the two bundles in more anatomic position.

  • PDF

A Comparison of the Results of BPTB and Hamstring ACL Autograft - Function, Stability & Tunnel Expansion - (골-슬개건-골 및 슬괵건을 이용한 전방 십자 인대 재건술의 비교 - 술후 슬관절의 기능, 안정성 및 대퇴, 경골터널 확장정도에 대하여 -)

  • Jung Young Bok;Tae Suk-Kee;Lim Jung Il
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • Purpose : The purpose of this study was to compare the results of ACL reconstruction using bone-patellar tendon-bone to hamstring. Materials and Methods : Thirty-two ACL reconstructions with autogenous BPTB and eighteen reconstructions with hamstring were compared in terms of functional outcome, stability and tunnel expansion. Results : The functional score of BPTB group was higher than hamstring group in OAK(Orthopadishe Arbeitsguppe Knie) and IKDC(International Knee Documentation Committee) system. In BPTB group, OAK scores were 71.6$({\pm}10.0)$ preoperatively and 88.5$({\pm}7.9)$ finally. In hamstring group, OAK scores were 73.9$({\pm}11.5)$ and 82.5$({\pm}12.9)$ respectively. There was no difference in stability checked by either $KT-1000^{TM}$ or stress view. Anterior tibial translation measured by $KT-1000^{TM}$ were 2.4$({\pm}1.8)$mm in BPTB and 2.3$({\pm}2.4)$mm in hamstring group. Anterior tibial translation in stress view were 2.8$({\pm}3.4)$mm in BPTB and 2.8$({\pm}2.5)$mm in hamstring group. There was no difference in tibial tunnel expansion but femoral tunnel was more enlarged in hamstring group than BPTB (P=0.03). Conclusion : As there was no difference in stability between two groups, it seems prudent to select either graft defend on such factors as anterior knee pain, skeletal maturity and cosmetic concern. Tunnel expansion seems not to affect stability, but further study is needed to confirm that decrease of which might improve stability.

  • PDF

The Clinical Results of ACL Reconstruction with Tibialis Allograft Using Hybrid Femoral Fixation and $Retroscrew^{(R)}$ (Hybrid 대퇴 고정과 $Retroscrew^{(R)}$를 사용한 동종 경골건 이용 전방 십자 인대 재건술의 임상적 결과)

  • Kim, Doo-Sub;Rah, Jung-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.8-13
    • /
    • 2009
  • Purpose: We used tibialis allograft for the reconstruction of ACL and used Hybrid femoral fixation utilizing $Endobutton^{(R)}$ and $Rigidfix^{(R)}$ for femoral fixation, and used $Retroscrew^{(R)}$ and additional fixation for tibial fixation to evaluate the clinical results. Materials and Methods: The ACL reconstruction were performed from February 2004 to February 2007 utilizing Hybrid femoral fixation and $Retroscrew^{(R)}$ and 32 patients, 32 cases which were available for year-long observation (12 to 25 months). The clinical results (Lysholm knee score, IKDC grade) and the radiologic results(bone tunnel expansion, Telos anterior displacement test) were evaluated. Results: The Lysholm knee score was improved from the average of $67.9{\pm}5.4$ points (range: 51~77) before operation and to $94.1{\pm}6.8$ points (range: 68~98) at the last follow up (p<0.05). 22 cases (69%) were evaluated normal (A), 9 cases (28%) were evaluated nearly normal (B) and only 1 case (3%) was evaluated not normal (C) at IKDC final evaluation and no case was evaluated abnormal. From $Telos^{(R)}$ stress x-ray evaluation, difference from the opposite knee was improved average 13.2 mm{\pm}5.8 (range: 6~21 mm) to average $3.4\;mm{\pm}2.8$ (range: 0~11 mm) after operation (p<0.05). The femoral and tibial tunnel were widened by 18.7% and 9.6% in the AP view and 12.4% and 8.5% in the lateral view, respectively (p<0.05). However, any statistic significance was not observed between bone tunnel expansion and knee joint functions (p>0.05). Conclusion: An ACL reconstruction with tibialis allograft using Hybrid femoral fixation and $Retroscrew^{(R)}$ enabled anatomical fixation of the graft tendon with satisfactory clinical results.

  • PDF