• Title/Summary/Keyword: Tendon elasticity

Search Result 7, Processing Time 0.022 seconds

Relationship between Muscle Strength and Tendon Stiffness of the Ankle Plantarflexors and Its functional Consequence (인체 족저굴곡근의 근력과 아킬레스 건의 경도, 기능적 능력 간 상관관계 분석)

  • Han, Seong-Won;Lee, Dae-Yeon;Lee, Hae-Dong
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.1
    • /
    • pp.35-42
    • /
    • 2014
  • Tendon elasticity is an important factor affecting muscle function and thus human movements. It has been reported that the mechanical properties of tendon are adaptable to external loading condition. Based on the adaptability of muscle and tendon to external loading conditions, one can assume that there might be an optimum ratio between muscle strength and tendon stiffness. The present study aimed to investigate whether there is correlation between plantar flexor muscle strength and stiffness of the achilles tendon (AT). Twenty two male subjects (age: $23.2{\pm}1.5yrs$, height: $175.5{\pm}6.2cm$, weight: $75.4{\pm}9.8kg$) performed maximum voluntary isometric plantarflexion on a custom-built dynamometer and muscle-tendon junction of the medial gastrocnemius muscle was simultaneously monitored using a real-time ultrasound imaging machine. The averages of muscle force and tendon stiffness were $366.38{\pm}79.37N$, $35.34{\pm}10.42N/mm$, respectively. Significant positive correlation was observed between muscle strength and tendon stiffness (r=0.8507), indicating that the muscle force is proportional to tendon stiffness. The results might have been used in computational modeling and criterion of training progress level in the fields of training and rehabilitation.

The Influence of Cooling on Muscle Force and Viscoelastic Properties of Human Tendon Structures in Vivo

  • Chae, Su-Dong;Jung, Myeong-Soo;Lee, Kyung-Il;Horii, Akira
    • Physical Therapy Korea
    • /
    • v.13 no.4
    • /
    • pp.30-38
    • /
    • 2006
  • This study was to investigate the influence of cooling on muscle force and viscoelastic properties of tendon structures in themedial gastrocnemius (MG) muscle. The subject was instructed to gradually increase force (10% MVC step) from a relaxed state to MVC within 3 s. At this time, it was measured by an ultrasonographic probe was attached and that an electrode was attached to monitor EMG. The F values at 50 100% of MVC were significantly greater under the cold condition than under the non-cold condition (p<.05). The ${\Delta}F/{\Delta}L$ values at 80~100% of MVC were significantly higher under the cold condition than under the non-cold condition (p<.05). The elongation under the non-cold condition had a tendency to be greater than that under the cold condition. The results suggest that cooling results in an increase in the stiffness of tendon structures with a reduction of muscle force and elongation.

  • PDF

Diagnostic Consistency between Sonoelastography and Conventional Sonography of Long Head of the Biceps

  • Yoon, Sunghyun;Seo, Joong-Bae;Yoo, Jae-Sung;Ryu, Jee-Won
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.3
    • /
    • pp.107-113
    • /
    • 2014
  • Background: Sonoelastography (SE) is a new technique that can assess differences in tissue stiffness, the purpose of this study was to evaluate the ability of SE to assess the long head of biceps tendon alteration. Methods: Forty shoulders of 36 consecutively registered patients with clinical symptoms and conventional ultrasonography findings of biceps tendinitis or tendinosis, and 40 asymptomatic shoulders of 20 healthy volunteers were assessed with SE. Transverse and longitudinal images of long head of biceps tendon were obtained using SE. SE images were performed by one orthopedic surgeon and evaluated by two orthopedic surgeons using an experimentally proven color grading system. Results: The transverse images of SE showed a sensitivity of 87.5%, a specificity of 95.0% and a accuracy of 91.3%, the longitudinal images of SE showed a sensitivity of 92.5%, a specificity of 90.0% and a accuracy of 91.3%. Inter-observer reliability of SE was in 'almost perfect agreement' with a weighted kappa coefficient of 0.83. Conclusions: SE is valuable in the detection of the intratendinous and peritendinous alterations of biceps tendon, and has excellent accuracy and excellent correlation with conventional ultrasound findings.

Differences in the Length Change Pattern of the Medial Gastrocnemius Muscle-Tendon Complex and Fascicle during Gait and One-legged and Two-legged Vertical Jumping (보행과 한발·두발 수직점프 수행 시 내측비복근 근-건 복합체와 근섬유다발의 길이 변화 패턴의 차이)

  • Lee, Hae-Dong;Han, Bo-Ram;Kim, Jin-Sun;Oh, Jeong-Hoon;Cho, Han-Yeop;Yoon, So-Ya
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.175-182
    • /
    • 2015
  • Objective : The purpose of this study was to investigate difference in fascicle behavior of the medial gastrocnemius during the locomotion with varying intensities, such as gait and one-legged and two-legged vertical jumping. Methods : Six subjects (3 males and 3 females; age: $27.2{\pm}1.6yrs.$, body mass: $62.8{\pm}9.8kg$, height: $169.6{\pm}8.5cm$) performed normal gait (G) at preferred speed and maximum vertical jumping with one (OJ) and two (TJ) legs. While subjects were performing the given tasks, the hip, knee and ankle joint motion and ground reaction force was monitored using a 8-infrared camera motion analysis system with two forceplates. Simultaneously, electromyography of the triceps surae muscles, and the fascicle length of the medial gastrocnemius were recorded using a real-time ultrasound imaging machine. Results : Comparing to gait, the kinematic and kinetic parameters of TJ and OJ were found to be significantly different. Along with those parameters, change in the medial gastrocnemius (MG) muscle-tendon complex (MTC) length ($50.57{\pm}6.20mm$ for TJ and $44.14{\pm}5.39mm$ for OJ) and changes in the fascicle length of the MG ($18.97{\pm}3.58mm$ for TJ and $20.31{\pm}4.59mm$ for OJ) were observed. Although the total excursion of the MTC and the MG fascicle length during the two types of jump were not significantly different, however the pattern of length changes were found to be different. For TJ, the fascicle length maintained isometric longer during the propulsive phase than OJ. Conclusion : One-legged and two-legged vertical jumping use different muscle-tendon interaction strategies.

Toinsul and Oriental Physical Therapy (도인술(導引術)과 한방 물리치료)

  • Bae Ju-Han;Kim Sang-Su
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.2
    • /
    • pp.195-200
    • /
    • 1998
  • Toinsul consists of breathing method and exercising method by stimulation of acupuncture point and meridian. It activates the circulation of energy and blood and helps excretion of noxious vapor and it improves elasticity and vitality of muscles, tendon md ligament. It sharpens both secretion of synovia .and circulation around joints and also controls the whole body through meridian. This report introduces some about the exercise methods for treatment of lumbago and shoulder joint diseases among medical, surgical and gynecological diseases. It can be used for health care, treatment, relaxation muscles and recovery from fatigue in an aspect of prevention. It has been widely used for treatment of diseases and promotion of health so far even though it is not yet demonstrated scientifically. Therefore, it should be used mere efficiently as an important part of the oriental physical therapy.

  • PDF

A Cadaveric Study of Thread Cubital Tunnel Release with Newly Developed Threads

  • Kang, Minsuk;Nam, Yong Seok;Kim, In Jong;Park, Hae-Yeon;Ham, Jung Ryul;Kim, Jae Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.2
    • /
    • pp.307-314
    • /
    • 2022
  • Objective : The percutaneous thread transection technique is a surgical dissecting method using a dissecting thread inserted through a needle under ultrasound guidance without skin incision. As the new dissecting threads were developed domestically, this cadaver study was conducted to compare the effectiveness and safety between the new threads (ultra V sswire and smartwire-01) and a pre-existing commercial dissecting thread (loop & shear) by demonstrating a modified looped thread cubital tunnel release. Methods : The percutaneous cubital tunnel release procedure was performed on 29 fresh cadaveric upper extremities. The pre-existing commercial thread was used in 5 upper extremities. The two newly developed threads were used in 24 upper extremities. Two practitioners performed the procedures separately. After the modified looped thread cubital release, anatomical and histological analyses were performed by a blinded anatomist. The presence of the dissected cubital tunnel and damaged adjacent soft tissue was assessed. Results : Out of the 29 cadaveric upper extremities, 27 specimens showed complete dissection of the Osborne ligament and the proximal fascia of the flexor carpi ulnaris muscle. One specimen was incompletely dissected in each of the ultra V sswire and smartwire-01 groups. There were no injuries of adjacent structures including the ulnar nerve, ulnar artery, medial antebrachial cutaneous nerve, or flexor tendon with either the commercial thread or the newly developed threads. The anatomical analysis revealed clear and sharp incisional margins of the cubital tunnel in the Smartwire-01 and loop & shear groups. All three kinds of threads maintained proper linear elasticity for easy handling during the procedure. The smartwire-01 provided higher visibility in ultrasound than the other threads. Conclusion : The newly developed threads were effective and safe for use in the thread cubital tunnel release procedure.

Restraint Coefficient of Long-Term Deformation and loss Rate of Pre-Compression for Concrete (콘크리트 장기변형의 구속계수와 선압축력의 손실률)

  • 연정흠;주낙친
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.521-529
    • /
    • 2002
  • A restraint coefficient for creep and dry shrinkage deformation of concrete in a composite section was derived to calculate the residual stress, and an equation for the loss rate of the pre-compression force was proposed. The derived restraint coefficient was computed by using the transformed section properties for the age-adjusted effective modulus of elasticity. The long-term behavior of complicate composite sections could be analyzed easily with the restraint coefficient. The articles of the current design code was examined for PSC and steel composite sections. The dry shrinkage strains of $150 ~ 200$\times$10^{-6}$ for the computations of the statically indeterminate force and the expansion joint could be under-estimated for less restrained sections such as the reinforced concrete. The dry shrinkage strain of $180$\times$10^{-6}$ for the computation of residual stress in the steel composite section was unreasonably less value. The loss rate of 16.3% of the design code for the PSC composite section in this study was conservative for the long-term deformation of the ACI 205 but could not be used safely for that of the Eurocode 2. For pre-compressed concrete slab in the steel composite section, the loss rate of prestressed force with low strength reinforcement was much larger than that with high strength tendon. The loss rate of concrete pre-compression increased, while that of pre-tension decreased due to the restraint of the steel girder.