• 제목/요약/키워드: Temporary ventilation

검색결과 25건 처리시간 0.022초

현장 실측을 통한 장대터널 공사중 환기 문제점 연구 (A Study on the Improvement of Temporary Ventilation of long tunnel Using the Field Measurement data)

  • 홍창수;황대진;강현욱
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1350-1357
    • /
    • 2010
  • In tunnelling, temporary ventilation is very important factor in the safety of worker and the work efficiency which is affected by visibility. There are a lot of problems in the recent tunnel construction, because the longer the tunnel, the more the present design doesn't satisfy the allowable standard about dust and air pollution. Especially, In case the length of tunnel is more than 1,000m, the ventilation efficiency tends to decrease. In this study, the field measurement of the degree of contamination was performed near the face of tunnel. Based on the results obtained, the main factors of problem in temporary ventilation are the difference of temperature between outside and inside, the rate of leakage of ventilation duct and the dust and so on. It maybe helpful to the solution of problems, and also the accurate ventilation estimate.

  • PDF

초장대 해저터널의 공사중 환기 특성에 관한 기초연구 - 현황 및 개선필요사항 중심 (A study on the characteristics for temporary ventilation of long subsea tunnels - focused on the current situation and improvement requirements)

  • 조형제;전규명;김종원;이주경
    • 한국터널지하공간학회 논문집
    • /
    • 제17권2호
    • /
    • pp.153-166
    • /
    • 2015
  • 일반적인 장대 철도터널에 비해 해저터널은 환기 및 방재를 위한 별도의 연직갱 또는 경사갱 설치에 공간상 많은 제약을 받게 되므로, 인공섬을 건설하여 환기를 수행할 필요가 있다. 그러나, 인공섬 설치에는 시공상의 문제 뿐만 아니라 건설비용이 증가하게 되므로, 인공섬 설치를 최소화하여 환기구간 거리를 늘려야 한다. 이에 따른 환기거리의 증가시, 누풍에 의한 신선공기 공급량이 커지게 된다. 공급풍량이 과대해지면, 구조물 한계에 의해 설치가능한 덕트직경이 제한적이므로, 팬 정압 및 동력도 상당히 증가하게 된다. 따라서, 초장대 해저터널을 건설하기 위해서는 이러한 현실적인 문제를 극복하고, 시공중 터널내 환경을 쾌적한 상태로 유지할 수 있는 기술력이 필요하다. 본 논문에서는 이러한 초장대 해저터널에 적합한 공사중 환기 방식을 개발하기 위한 기본연구로써, 국내외의 공사중 환기용량 산정방법 비교를 통해, 스위스의 SIA 196 코드가 초장대 해저터널계획에 적합함을 확인하였다. 또한, 덕트 접속부의 누출에 관한 실험을 통해, 국내의 덕트 접속방식은 100 m당 누풍율이 1.5~3.0% 사이임을 확인하였다. S등급 덕트의 경우 환기가능거리가 10.2 km 이므로, 덕트의 접속방법을 개선한다면, 환기가능거리는 더 길어질 수 있다. 따라서, 공사중 덕트의 누풍개선이 초장대 해저터널의 공사중 환기의 주요 이슈임을 확인하였다.

공사 중 환기덕트 누풍 최소화를 위한 접속부 개발 및 성능평가 연구 (A study on the development and performance evaluation of duct coupling for the minimized leakage of temporary ventilation duct)

  • 조형제;전규명;민대기;김종원;백종훈
    • 한국터널지하공간학회 논문집
    • /
    • 제20권1호
    • /
    • pp.145-160
    • /
    • 2018
  • 초장대 해저터널은 환기를 위한 연직갱 또는 경사갱 설치에 공간적으로 많은 제한을 받게 되므로 일부 인공섬을 건설하여 환기를 수행할 필요가 있다. 그러나 인공섬 설치는 건설의 어려움뿐만 아니라 건설비용이 증가하게 되므로 인공섬 설치를 최소화할 필요가 있다. 이에 따라 환기거리가 증가하여 누풍에 의한 공급 풍량이 커지게 되면, 공사 중 환기를 위한 덕트 설치가 불가능해지거나 팬 정압 및 동력이 상당히 증가하게 된다. 따라서 초장대 해저터널을 건설하기 위해서는 이러한 현실적인 문제를 극복하고 시공 중 터널 내 환경을 쾌적한 상태로 유지할 수 있는 기술력이 필요하다. 선행 연구에서 우리는 누풍이 이 문제들을 해결하는 핵심 인자이며 실험 결과 새로운 접속방식의 누풍율은 대략 $1.46mm^2/m^2$임을 밝혔다(Jo et al., 2017). 본 연구에서는 새로운 접속방식이 적용된 시제품의 누풍율 측정 결과를 제시하고 기존 접속방식의 누풍 성능 개선을 위해 덕트 내부에 연질막 적용시의 누풍 성능 개선을 실험적으로 분석하였다.

전기자극에 의한 횡격막 조율을 이용한 호흡보조장치 (Respiratory Assist by Use of Electrical Diaphragmatic Pacing)

  • 오중환;김은기;서재정;박일환;김부연;이상헌;이종국;이영희
    • Journal of Chest Surgery
    • /
    • 제34권6호
    • /
    • pp.441-446
    • /
    • 2001
  • 배경: 전기 자극에 의한 호흡조율장치는 인공호흡기에 비하여 많은 장점이 있으나 임상적으로 제한된 환자에게만 적용이 되어왔고 일시적인 조율장치는 별로 보고가 없는 실정이다. 본 실험의 목적은 일시적 호흡보조장치가 개흉술 환자에서 임상응용이 가능한지를 알고자 동물실험을 하였다. 대상 및 방법: 전신마취 하에 5마리의 개를 대상으로 하였다. 좌측 5번째 늑간을 열고 자체 고안한 일시적 사용 가능한 전극을 좌측 횡격 신경 주위에 설치하고 근자극기에 연결하였다. 흉벽을 봉합하고 흉관을 수면 아래로 배관되게 설치하였다. 대동맥과 우심방에 Millar 카테터를 삽입하고 Swan-Ganz 카테터를 폐동맥에 삽입하였다. 마취가 깊게되어 자기 호흡이 약해진 경우 자극기를 작동하여 혈역학적 변화와 일회호흡량을 관찰하였다. 결과 일회호흡량은 143.3$\pm$51.3ml에서 272.3$\pm$87.4ml(p=0.004)로 증가하였고 우심방 이완기압은 0.7$\pm$4.0mmHg에서 -10.5$\pm$4.7mmHg(p=0.005)로 감소하였다. 폐동맥 이완기압도 6.1$\pm$2.5mmHg에서 1.2$\pm$4.8mmHg(p<0.001)로 감소하였다. 흉강내압의 변화를 알 수 있는 흉관의 물기등 높이는 10.3$\pm$6.7cmH$_{2}$O에서 20.0$\pm$5.3cmH$_{2}$O로 증가하였다. 결론: 일시적인 횡격막 조율장치는 개흉술 예에서 일시적으로 호흡을 보조해주는 간편한 방법이다. 자체 고안한 전극은 삽입 및 제거가 가능하며 이러한 음압을 이용한 호흡보조장치는 혈액순환에도 도움을 준다. 임상적으로 개흉술 환자에서 일시적인 호흡보조장치를 응용하면 호흡 및 순환기에도 도움을 줄 수 있을 것으로 사료된다.

  • PDF

강제환기장치 사용에 따른 단동 플라스틱 온실 기온 강하 특성 (Characteristics of Cooling Effect Depending on Operation of Forced Ventilation Systems in a Single-span Plastic Greenhouse)

  • 김성헌;김형권;권진경;이시영
    • 생물환경조절학회지
    • /
    • 제31권3호
    • /
    • pp.143-151
    • /
    • 2022
  • 본 연구는 권취식 측창을 갖는 아치형 단동 플라스틱 온실 내 강제환기장치 설치 및 운용, 환기 성능 개선방안 등을 제안하기 위해 온실 내부에 유동팬과 배기팬을 설치하여 강제환기장치 사용에 따른 온실 내부기온 강하 특성을 정량적으로 조사하였다. 시험은 3가지 환기 조건(측창, 측창+순환팬, 측창+순환팬+배기팬)에서 수행되었다. 각 조건 데이터로거를 이용하여 환기 시작과 동시에 온실 내외부 기온 및 외부환경 변화를 측정·기록하였고, 환기 방식별 기온차 변화의 평균값으로 부터 정규기온차를 계산하여 기온 강하 효과를 비교하였다. 오전(11:00-12:00)에는 환기 방식에 상관없이 환기 초반 정규기온차가 일시적으로 증가했다가 감소하는 것으로 나타났다. 강제환기장치가 더 많이 사용될수록 최대 정규기온차는 1.158에서 1.037로 감소하였고 최대 정규기온차에 도달하는 시간도 340초에서 110초로 단축되었다. 강제환기장치의 사용은 정규기온차가 0.8까지 감소하는데 소요된 시간을 1,030초에서 550초로, 0.6까지는 1,610초에서 915초로, 0.4까지는 2,315초에서 1,360초로, 자연환기의 약60% 수준으로 감소시켰다. 오후(14:00-15:00)에는 정규기온차의 증가가 관측되지 않았지만, 환기 시작과 동시에 기온차가 감소하기 시작했다. 또한 강제환기장치가 더 많이 사용될수록 정규기온차가 0.8까지 내려가는 시간을 560초에서 345초로, 0.6까지는 825초에서 540초로, 0.4까지는 560초에서 345초로, 약70% 수준으로 감소시켰다. 따라서, 보다 효과적이고 경제적인 환기를 위해 강제환기장치는 오전과 같이 열부하가 높은 환경에서 적극적으로 사용하는 것이 바람직하다고 판단된다.

Characteristic of indoor air quality according to ventilation in a temporary residential building

  • Chae, Ho-Byung;Nam, Yujin;Sung, Min-Ki;Kim, Jong-Hun
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.5-12
    • /
    • 2015
  • Recently, natural disasters have unexpectedly occurred at various places in the world and the countermeasure of them become the social issues. Many of victims in disasters need temporary residential facilities above all things and many of researches have been conducted in order to develop simple, safe, and economic designs of them. Moreover, indoor thermal comfort and air quality must be considered in the facilities against a disaster, because clean and healthy space should be provided to the suffered victims. In this research, in order to estimate the indoor environment of the developed modular building for disaster preparation, CFD simulation was conducted in the various condition. In this paper, indoor air quality such as the age of air, the concentration of $CO_2$ was estimated by the case study

농어촌 재해복구용 모듈러 건축물의 설계안 연구 (A Study on the Design Model of Modular Building System for Disaster Restorations in Fishing and Agrarian Villages)

  • 임재한
    • 한국농촌건축학회논문집
    • /
    • 제9권3호
    • /
    • pp.33-45
    • /
    • 2007
  • Recently, large scale disasters have been occurred in rural areas. Most people suffering from the disaster live in the temporary containers. These could not provide the fundamental occupancy performances such as thermal insulation, ventilation and heating system. It is very important to rebuild the residence for sufferers quickly and safely. Because modular building system has some advantages such as short construction time, mobility, light-weight structure, modularity, flexibility and economical efficiency, it is expected that it could be easily applied to the disaster restoration. So, this research aims at developing the design model of modular building system for disaster restorations in fishing and agrarian villages. For this purpose, current counterplan for restoration was firstly investigated. Also the basic guideline was established through the investigation of current status of residence in fishing and agrarian villages. Finally, 2 types of design model such as single story residence and temporary accommodation facility were proposed. We could see that we could make the flexible building plan when applying the modular building system to the temporary housing for the sufferers.

  • PDF

디클로로메탄 사용 세척공정의 국소배기장치 설치 후 노출농도 변화 (Change in Exposure Concentration in the Cleaning Process after Installing a Local Exhaust System)

  • 조명화;김승기;김현수
    • 한국산업보건학회지
    • /
    • 제33권3호
    • /
    • pp.280-283
    • /
    • 2023
  • Objectives: The purpose of this study was to examine the change in exposure concentration in the cleaning process after installing a local exhaust system. Methods: Dichloromethane measurement was conducted according to the KOSHA Guide (A-19-2019). Results: After the local exhaust device was installed, a total of three measurements were conducted, including temporary work environment measurements, and all of the measurements did not exceed the DCM exposure standard, but were more than 50% of the DCM Time Weighted Average((8-TWA) Conclusions: It is thought that the local ventilation system of a small business needs not only support for the initial installation cost, but also educational support for maintaining the performance of the local ventilation system and support for consumables (adsorbents, filters, etc.) that incur periodic costs.

지하환기소 대단면 터널 시공 사례 연구 (A Case Study on the Construction of Large Cross Section Tunnel for Underground Ventilation System)

  • 노승환;최성욱;노상림
    • 터널과지하공간
    • /
    • 제27권4호
    • /
    • pp.195-204
    • /
    • 2017
  • 본 사례연구에서는 신림~봉천터널 지하환기소 대단면 터널의 시공 사례를 소개하였다. 환기갱(폭 7.8 m, 높이 6.6 m)에서 환기소(축류팬실, 폭 20.8 m, 높이 12.3 m)로 터널 단면이 확대되는 구간에 대해 안전성 및 시공성 등을 고려하여 점진적인 확대 굴착 방안 및 Q 시스템을 이용한 확폭 구간의 임시 보강 방안이 검토되었다. 확폭이 완료된 이후 대단면 터널은 현장의 암반조건을 확인하고, 전산해석을 이용한 터널의 안정성 검토 등을 통해 암반등급에 따라 굴진장을 일부 조정하고, 터널 상부 굴착을 분할 없이 전단면 굴착으로 변경하여 시공성을 향상시켰다. 본 사례연구에서 소개한 시공 사례가 향후 유사한 조건의 지하환기소 또는 4차로 도로 등의 대단면 터널의 설계 및 시공에 유용한 참고 자료가 될 수 있기를 기대한다.

초장대 해저터널의 공사중 덕트 접속부의 누풍 성능 개선에 관한 연구 (A study on the air leakage performance improvement of duct coupling for temporary ventilation of long subsea tunnel)

  • 조형제;민대기;김종원;이주경;백종훈
    • 한국터널지하공간학회 논문집
    • /
    • 제19권2호
    • /
    • pp.319-333
    • /
    • 2017
  • 초장대 해저터널의 건설은 건설공간의 제약 및 건설비용 측면에서, 공사중에 사용되는 환기 시스템 설치에 유리한 조건을 갖고 있지 않다. 공사중 환기시스템을 제공하기 위해, 환기갱이 설치되는 인공섬들이 해저터널의 루트를 따라서 일부위치마다 건설됨으로써, 건설 비용이 많이 소요된다. 따라서 이러한 인공섬의 수를 최소화하는 것이 경제적으로 필요하다. 그러나 이것은 환기갱 사이의 거리가 더 길어지게 되므로, 필요한 환기풍량을 이송하기 위한 높은 팬 압력으로 인해 환기 덕트 접속부에서 누풍이 더 많이 발생하게 된다. 선행 연구에서 공기 누설이 중요한 문제임을 조명하였다. 본 연구는 개선된 덕트 접속 방식을 개발하기 위한 실험들을 소개하고, 또한 SIA 의 "S" 등급 누풍율 및 다양한 조건들을 비교하여 터널 연장에 따른 달성된 누풍율의 환기 성능을 제시한다. 본 연구의 결과로 누풍율이 $1.46mm^2/m^2$인 새로운 접속방식을 개발하였으며, 개선된 방식이 30 km규모의 장대터널에 적합한 것으로 분석되었다.