• Title/Summary/Keyword: Tempering temperature

Search Result 168, Processing Time 0.025 seconds

Influence of Steel-making Process and Heat-treatment Temperature on the Fatigue and Fracture Properties of Pressure Vessel Steels (제강 및 열처리 조건이 압력용기강의 피로 및 파괴특성에 미치는 영향)

  • Koh, S.K.;Na, E.G.;Baek, T.H.;Park, S.J.;Won, S.Y.;Lee, S.W.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.87-92
    • /
    • 2001
  • In this paper, high strength pressure vessel steels having the same chemical compositions were manufactured by the two different steel-making processes, such as vacuum degassing(VD) and electro-slag remelting(ESR) methods. After the steel-making process, they were normalized at $955^{\circ}C$, quenched at $843^{\circ}C$, and finally tempered at $550^{\circ}C$ or $450^{\circ}C$, resulting in tempered martensitic microstructures with different yielding strengths depending on the tempering conditions. Low-cycle fatigue(LCF) tests, fatigue crack growth rate(FCGR) tests, and fracture toughness tests were performed to investigate the fatigue and fracture behaviors of the pressure vessel steels. In contrast to very similar monotonic, LCF, and FCGR behaviors between VD and ESR steels, a quite difference was noticed in the fracture toughness. Fracture toughness of ESR steel was higher than that of VD steel, being attributed to the removal of impurities in steel-making process.

  • PDF

Adjustment Of Roll Gap For The Dimension Accuracy Of Bar In Hot Bar Rolling Process (열간 선재 압연제품의 치수정밀도 향상을 위한 롤 갭 조정)

  • 김동환;김병민;이영석;유선준;주웅용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.1036-1041
    • /
    • 1997
  • The objective of this study is to adjust the roll gap for the dimension accuracy of bar in hot bar rolling process considering roll wear. In this study hot bar rolling processes for round and oval passes have been investigated. In order to predict the roll wear, the wear model is reformulated as an incremental form and then wear depth of roll is calculated at each deformation step on contact area using the results of finite element analysis, such as relative sliding velocity and normal pressure at contact area. Archard's wear model was applied to predict the roll wear. To know the effects of thermal softening of DCI (Ductile Cast Iron) roll material according to operating conditions, high temperature micro hardness test is executed and a new wear model has been proposed by considering the thermal softening of DCI roll expressed in terms of the main tempering curve. The new technique developed in this study for adjusting roll gap can give more systematically and economically feasible means to improve the dimension accuracy of bar with full usefulness and generality.

  • PDF

The Effect of Isothermal Annealing on Microstructure of Forged Parts (단조품의 등온 어닐링에 따른 미세조직 변화)

  • Kim, D.B.;Lee, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.5
    • /
    • pp.303-308
    • /
    • 2000
  • The ring gears of automobile parts are manufactured generally process chart of which is as follows : forging ${\rightarrow}$ annealing or normalizing ${\rightarrow}$ rough machining ${\rightarrow}$ hardening(Quenching-Tempering or carburizing process) ${\rightarrow}$ finish machining. Isothermal annealing process after forging is most effective in the side of improvment of machinability. On this study we selected two kinds of steel;SCM415, SCM435 of most universal and investigated microstructures to find out most suitable condition of heat treatment in proportion continuous cooling and isothermal annealing. As the cooling rate is $5^{\circ}C$ per minute in continuous cooling process, martensite and bainite are coexisted with ferrite and pearlite in SCM435 steel. If the cooling rate is slower than $5^{\circ}C$ per minute, microstructure were only ferrite and pearlite but formation of band structure can't be avoid. On the other hand, microstructure is only ferrite and pearlite regardless of cooling rate because carbon content of SCM415 steel is low. Moreover formation of band structure isn't exposed by faster cooling rate. Most optimal temperature of the isothermal annealing is from $650^{\circ}C$ to $680^{\circ}C$ in SCM435 steel. When holding time is 60 minute with $650^{\circ}C$, the identical ferrite and pearlite microstructures can be obtained.

  • PDF

A Study on Mechanical Properties of Micro-Alloyed Steel According to Baking Temperature (베이킹 온도에 따른 비조질강 기계적 특성)

  • Lee, S.H.;Lee, K.T.;Kwon, Y.N.;Kim, J.H.
    • Transactions of Materials Processing
    • /
    • v.15 no.8 s.89
    • /
    • pp.621-627
    • /
    • 2006
  • Recently, micro-alloyed steels which could eliminate heat treatments after forging has been developed. These non heat-treated micro-alloyed steels have several advantages over the conventional quenched and tempered steel for cold forging. First of all, long components can be fabricated with a better dimensional accuracy since bending of long forged part after quenching treatment could be avoided. And it is possible to eliminate two energy consuming heat treatment steps, which are a spherodizing before forging and quenching/tempering after forging. Therefore, more cost effective and environment friendly process could be designed. However, there is non-uniform distribution of strain occurred across the forged part, since these non heat-treated micro-alloyed steel use strain hardening mechanism. In the present study, it was investigated how to lessen non-uniformity and increase strength together for cold forging when a baking heat treatment is applied in micro-alloyed steels. For this purpose, micro-alloyed steels developed by Se-A Besteel recently was used for the experiment.

Heat Treatment for Improvement of Hardness Uniformity of Standard Hardness Blocks (경도 기준편의 경도 균일성 향상을 위한 열처리)

  • Hahn, J.H.;Hwang, N.M.;Kim, J.J.;Moon, H.G.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.2 no.2
    • /
    • pp.33-37
    • /
    • 1989
  • In order to improve hardness uniformity of standard-hardness blocks. experimental procedure was designed using Taguchi Method. For this purpose the following factors were studied: austenitizing temperature, tempering condition, grinding condition, subzero treatment, lapping time, $15{\mu}m$ polishing time, final polishing time. These factors were processed and then ten hardness values were measured on each specimen. SN (signal to noise) ratio for each condition was calculated with standard variations of these values. Finally, from the calculated value of ANOVA on SN ratios, the lapping time was found to be the main factor Better uniformity with longer lapping time implies that residual stress that was formed after quenching is a dominent parameter that affects on the uniformity of hardness. Therefore, step-quenching method was adapted to minimize the residual stress. By this modification of quenching procedure, the hardness uniformity was improved remarkably and the yield ratio was increased from 55% to 88%.

  • PDF

Effect of TempCore Processing on Microstructure and Mechanical Properties of 700 MPa-Grade High-Strength Seismic Resistant Reinforced Steel Bars (700 MPa급 고강도 내진 철근의 미세조직과 기계적 특성에 미치는 템프코어 공정의 영향)

  • Shin, S.H.;Kim, S.K.;Lim, H.G.;Hwang, B.
    • Transactions of Materials Processing
    • /
    • v.30 no.2
    • /
    • pp.91-98
    • /
    • 2021
  • The present study deals with the microstructure and mechanical properties of 700 MPa-grade high-strength seismic resistant reinforced steel bars fabricated by various TempCore process conditions. For the steel bars, in the surface region tempered martensite was formed by water cooling and subsequent self-tempering during TempCore process, while in the center region there was ferrite-pearlite or bainite microstructure. The steel bar fabricated by the highest water flow and the lowest equalizing temperature had the highest hardness in all regions due to the relatively fine microstructure of tempered martensite and bainite. In addition, the steel bar having finer microstructures as well as the high fraction of tempered martensite in the surface region showed the highest yield and tensile strengths. The presence of vanadium precipitates and the high fraction of ferrite contributed to the improvement of seismic resistance such as high tensile-to-yield strength ratio and high uniform elongation.

A Study on the Wear Characteristics and Lifetime Of High Chromium Roll (고크롬 롤의 수명과 마멸특성에 관한 연구)

  • Kim, M.K.;Kim, S.K.;Jeon, E.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.2
    • /
    • pp.58-65
    • /
    • 1997
  • Work rolls used in cold rolling mills must have outstanding wear resistance and very little plastic defor- mation. Thus, these rolls require a higher surface hardness and harding to a greater depth. To meet these requirements, the rolls, in general, have basic chemical composition of 0.7 to 1.0% carbon and 1.0 to 5.0% Cr(chromium), plus a small amounts of special elements, and are subjected to intensive water quenching and tempering at low temperature to provide a surface hardness of over 90 shore. This test results are as follows. Deflection and fracture load of 5% Cr material are than those of 3% Cr material and show flat curve from surface to subsurface. It will be clear that 5% Cr work roll has a superior resisti- bility against wear and abrasion comparing with 3% Cr work roll. The improvement of wear and abrasion in 5% Cr work roll will be achieved by the large amount of wpheroidal carbide. In grindability and polish, 5% Cr work roll will be a little inferior comparing with 3% Cr work roll.

  • PDF

A Study of Mechanical Properties With Variation of Heattreatments on HSLA Cast Steels Microalloyed With Nb, Ti, and V (Nb, Ti 및 V를 첨가한 HSLA 주강의 열처리 변화에 따른 기계적 특성 연구)

  • Park, Jae-Hyeon;Kim, In-Bae
    • Korean Journal of Materials Research
    • /
    • v.10 no.11
    • /
    • pp.760-769
    • /
    • 2000
  • Mechanical properties of HSLA cast steels alloyed with 0.15% Nb, Ti or V were tested as variations of austenizing temperatures and tempering times. The test results are as follows. The hardness of HSLA cast steels austenized for 2hrs at 115$0^{\circ}C$ was shown the highest value regardless of alloying elements and then decreased as the temperature decreased below 110$0^{\circ}C$. The hardness of HSLA cast steels with 0.15% Ti austenized for 2 hrs at $1150^{\circ}C$ was higher than that of any other HSLA cast steels, and chich was mainly attributed to the relatively high amount of bainite, and solid solution hardening. Charpy impact energy of HSLA cast steels was comparable to the C-Mn cast steel except HSLA cast steels with 0.15% Ti austenized at 115$0^{\circ}C$. The hardness of HSLA cast steels austenized for 2 hrs at $1150^{\circ}C$ increased at a ten-minute tempering, and after that, the hardness kept almost sililar level except HSLA cast steels with 0.15% V.

  • PDF

A Study on Microstructure and Mechanical Properties of TiC/Steel Composites Fabricated by Powder Metallurgy Process (분말야금공정으로 제조된 TiC/steel 금속복합재료의 미세조직 및 기계적 물성 연구)

  • Lee, Jihye;Cho, Seungchan;Kwon, Hansang;Lee, Sang-Kwan;Lee, Sang-Bok;Kim, Daeha;Kim, Junghwan
    • Composites Research
    • /
    • v.34 no.5
    • /
    • pp.311-316
    • /
    • 2021
  • In this study, TiC/steel metal matrix composites were fabricated by powder metallurgy process using Fealloy powders with 3 wt.% Cr and 10 wt.% Cr, respectively, as matrix material. Subsequently, the composite samples were heat treated by the annealing and quenching-tempering(Q-T), respectively, to understand the effect of heat treatment on the mechanical properties of the composites. The correlation between microstructure and structural strength depending on the chromium content and the heat treatment conditions was studied through tensile, compressive, and transverse rupture test and microstructural analysis. In the case of TiC/steel composite containing 10 wt.% Cr, the tensile strength and transverse rupture strength at room temperature were significantly lowered by the influence of coarse chromium carbide formed at the TiC/steel interface. On the other hand, both TiC/steel composites containing 3 wt.% Cr and 10 wt.% Cr showed much higher compressive strength of about 4 GP after quenching-tempering compared to the annealed specimens regardless of the presence of the chromium carbide.

Performance Evaluation of Rough Rice Low Temperature Drying Using Heat Pump (열펌프를 이용한 벼의 저온건조성능평가)

  • Kim, Hoon;Han, Jae-Woong
    • Food Engineering Progress
    • /
    • v.13 no.4
    • /
    • pp.308-313
    • /
    • 2009
  • This study was conducted to design and fabricate a heat pump that can produce some weather conditions similar to those of the dry season of the rough rice in Korea, and to investigate basic performances of the apparatus. During the drying test, the amount of energy consumption and drying characteristics were measured at four different temperature levels ranging between 20$^{\circ}C$ and 50${^{\circ}C}$. In the psychrometric chart, the freezing capacity and refrigerant circulation ratio of the heat pump were 173 kJ/kg and 49.6 kg/hr, respectively. Therefore, coefficient of performance was 5.5, which was superior to that of refrigerant R-22 (4.0) in standard refrigeration cycle. In addition, the time to reach target drying temperature (30${^{\circ}C}$) and relative humidity (40%) were 6 minutes and 7 minutes, respectively. Temperature differences between the drying temperature and the rice were 1.5${^{\circ}C}$ and 8.5${^{\circ}C}$ at the drying temperatures of 21.9${^{\circ}C}$ and 48.7${^{\circ}C}$, respectively. This result demonstrated that the increased temperature of the rice in the drying section decreased sufficiently in the tempering section. At the drying temperatures of 21.9, 30.7 38.8, and 48.7${^{\circ}C}$, drying rates were 0.29, 0.61, 0.85, and 1.26%/hr, respectively, which were similar to those of commercial dryer. In addition, the amounts of energy consumption were 325, 667, 692, and 776 kJ/kg, respectively. These results showed that this dryer saved up to 86% of energy consumption compared with the commercial dryer, which uses 4,000-5,000 kJ/kg of fossil fuel.