• Title/Summary/Keyword: Temperature variation

Search Result 5,661, Processing Time 0.04 seconds

Seasonal Variation of Fish Catch Using a Fence Net in the Shallow Tidal Flat off Ganghwado, Korea (강화도 갯벌 천해의 건간망 어획 어류의 계절 변동)

  • HWANG Sun Wan;KIM Chong Kwan;LEE Tae Won
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.6
    • /
    • pp.676-685
    • /
    • 2003
  • Seasonal variation of the fishery resource in the shallow waters of Ganghwado tidal flat was investigated using monthly collected samples with a fence net from June 1998 to May 1999. Thirty-six species were found including 27 fish species, 6 crustaceans, and 3 molluscs. Of the fish, Konosirus punctatus, Sardinella zunasi Liza haematocheila and Synechogobius hasta dominated in the number of individuals $(92.1\%)$ and in biomass $(94.5\%).$ A few number of resident species, such as L. haematocheila and S. hasta, were collected only during the cold months. As the water temperature increased in the spring, the adult migratory fish such as K. punctatus and S. zunasi, were collected. In the summer, the juvenile fish recruited in the shallow water showing a peak in fish abundance. The data suggested that they grew until late autumn before moving to deeper waters for over-wintering. The principal component analysis showed that the seasonal variation in species composition was principally determined by water temperature and/or water temperature related factors. The species composition of the fish assemblage in the study area suggested that these species are highly adapted to extreme seasonal temperature variation and high water turbidity.

Variation Pattern of ${\delta}^{13}C_{DIC}$ of the Odaecheon Stream Water

  • Shin, Woo-Jin;Chung, Gong-Soo
    • 한국지구과학회:학술대회논문집
    • /
    • 2005.02a
    • /
    • pp.115-125
    • /
    • 2005
  • Carbon isotopic composition of a stream (Odaecheon Stream) monitored over 7 months from July 2004 to January 2005 in Gangweon Province ranges from -9.24 to -4.69‰. Strong negative correlation between ${\delta}^{13}C_{DIC}$ and water temperature suggests that temperature is a dominant factor controlling ${\delta}^{13}C_{DIC}$ in the Odaecheon Stream. The variation pattern of ${\delta}^{13}C_{DIC}$ was thought to be caused by fractionation of C isotope between stream water and atmosphere and more fractionation at reduced temperature. More fractionation of C isotope between stream water and atmosphere at reduced temperature resulted in increase of ${\delta}^{13}C_{DIC}$ of stream water in winter compared to summer. Photosynthesis and respiration of aqueous biota seem to affect little in ${\delta}^{13}C_{DIC}$ as indicated by little variation of dissolved oxygen and reverse variation pattern of Eh in the stream and scarce aqueous biota in stream water. pH seems to be controlled by $CO_2{2}$ exchange between stream water and atmosphere. During summer more $CO_2{2}$ exchange between stream water and atmosphere resulted in decrease in pH value.

  • PDF

Analysis of Surface Water Temperature Fluctuation and Empirical Orthogonal Function in Cheonsu Bay, Korea

  • Hyo-Sang Choo;Jin-Young Lee;Kyeung-Ho Han;Dong-Sun Kim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.3
    • /
    • pp.255-269
    • /
    • 2023
  • Surface water temperature of a bay (from the south to the north) increases in spring and summer, but decreases in autumn and winter. Due to shallow water depth, freshwater outflow, and weak current, the water temperature in the central to northern part of the bay is greatly affected by the land coast and air temperature, with large fluctuations. Water temperature variations are large in the north-east coast of the bay, but small in the south-west coast. The difference between water temperature and air temperature is greater in winter and in the south-central part of the bay than that in the north to the eastern coast of the bay where sea dykes are located. As the bay goes from south to north, the range of water temperature fluctuation and the phase show increases. When fresh water is released from the sea dike, the surrounding water temperature decreases and then rises, or rises and then falls. The first mode of empirical orthogonal function (EOF) represents seasonal variation of water temperature. The second mode represents the variability of water temperature gradient in east-west and north-south directions of the bay. In the first mode, the maximum and the minimum are shown in autumn and summer, respectively, consistent with seasonal distribution of surface water temperature variance. In the second mode, phases of the coast of Seosan~Boryeong and the east coast of Anmyeon Island are opposite to each other, bordering the center of the deep bay. Periodic fluctuation of the first mode time coefficient dominates in the one-day and half-day cycle. Its daily fluctuation pattern is similar to air temperature variation. Sea conditions and topographical characteristics excluding air temperature are factors contributing to the variation of the second mode time coefficient.

Effect of Mixture Ratio Variation near Chamber Wall in Liquid Rocket Engine

  • Han, Poong-Gyoo;Kim, Kyoung-Ho
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.4 no.2
    • /
    • pp.51-60
    • /
    • 2003
  • An experimental research program is being undertaken to develop a regeneratively-cooled experimental thrust chamber of liquid rocket engine using liquefied natural gas and liquid oxygen as propellants. Prior to firing test using a regenerative cooling with liquefied natural gas in this program, several firing tests were conducted with water as a coolant. Experimental thrust chambers with a thrust of about 10tf were developed and their firing test facility was built up. Injector used in the thrust chamber was of shear-coaxial type appropriate for propellants of gas and liquid phase and cooling channels are of milled rectangular configuration. Periodical variation of the soot deposition and discoloration was observed through an eyes' inspection on the inner wall of a combustion chamber and a nozzle after each firing test, and an intuitive concept of the periodical variation of mixture ratio near the inner wall of a combustion chamber and a nozzle at once was brought about and analyzed quantitatively. Thermal heat flux to the coolant was calculated and modified with the periodical variation model of mixture ratio, and the increment of coolant temperature at cooling channels was compared with measured one.

A Study on the Roll Gap Set-up to Compensate Thickness Variation at Top-end in Plate Rolling (후판 압연시 선단부 두께편차 보상을 위한 롤갭 설정에 관한 연구)

  • Yim, H.S.;Joo, B.D.;Lee, G.Y.;Seo, J.H.;Moon, Y.H.
    • Transactions of Materials Processing
    • /
    • v.18 no.4
    • /
    • pp.290-295
    • /
    • 2009
  • The roll gap set-up in the finishing mill is one of the most important technologies in the hot plate rolling process. As the target thickness can be obtained by the correct set-up of the roll gap, improving the roll gap set-up technology is very critical for plate thickness accuracy. The main cause of thickness variation in hot plate mills is the non-uniform temperature distribution along the length of the slab. The objective of this study is to adjust the roll gap set-up for the thickness accuracy of plate in hot rolling process considering top-end temperature drop. Therefore this study has concentrated on determining the correct amounts of thickness variation according to top-end temperature drop and roll gap to compensate thickness variation. The control method of roll gap set-up which can improve the thickness accuracy was proposed. The off-line simulation of compensated roll gap significantly decreases top-end thickness variation.

Monitoring of Temperature and Strain Variation with FBG Sensors (FBG 센서를 활용한 온도와 스트레인 변화 모니터링)

  • Ko, Ki-Han;Park, Young;Cho, Yong-Hyeon;Jung, Ho-Sung;Cho, Yong-Suk;Choi, Won-Seok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.3
    • /
    • pp.218-221
    • /
    • 2009
  • This paper reports on measurement method for the fiber optic strain monitoring of overhead contact line systems of trains, We used FBG (Fiber Bragg Grating) sensors to measure the strain variation of overhead contact line. FBG sensors can sensitively measure the variation of strain and! or temperature by the shift wavelength of reflected wave according to the lattice variation during the measurement. FBG sensor were attached on the contact line and connected to the monitoring system with optical fibers. The monitering system with FBG sensors showed very good sensitivity to measuring strain variation and this system could be applied to the overhead contact line of KTX (Korea Train eXpress).

Thermal buckling resistance of simply supported FGM plates with parabolic-concave thickness variation

  • Benlahcen, Fouad;Belakhdar, Khalil;Sellami, Mohammed;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • v.29 no.5
    • /
    • pp.591-602
    • /
    • 2018
  • This research presents an investigation on the thermal buckling resistance of FGM plates having parabolic-concave thickness variation exposed to uniform and gradient temperature change. An analytical formulation is derived and the governing differential equation of thermal stability is solved numerically using finite difference method. A specific function of thickness variation is introduced where it controls the parabolic variation intensity of the thickness without changing the original material volume. The results indicated that the loss ratio in buckling resistance is the same for any gradient temperature profile. Influencing geometrical and material parameters on the loss ratio in the thermal resistance buckling are investigated which may help in design guidelines of such complex structures.

Temperature dependent hysteresis characteristics of a-Si:H TFT (비정질 실리콘 박막 트랜지스터 히스테리시스 특성의 온도의존성)

  • 이우선;오금곤;장의구
    • Electrical & Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.277-283
    • /
    • 1996
  • The temperature dependent characteristics of hydrogenerated amorphous silcon thin film transistor (a-Si:H TFT) with a bottom gate of N-Type <100> Si wafer were investigated. Drain current on the hysteresis characteristic curve showed an exponential variation. Hysteresis area of TFT increased with the gate voltage increased and decreased with the small gate voltage. According to the variation of gate voltages, drain current of TFT increased by temperature increase, and hysteresis characteristics mainly depended on the temperature increase. The hysteresis current showed negative characteristics curve over 383K. The hysteresis occurance area and the differences of forward and reverse sweep were increased at the higher temperature. Hysteresis current of I$_{d}$(on/off) ratio decreased at the lower temperature and increased at the higher temperature.e.

  • PDF

An Experimental Study on the Effect of Temperature and Humidity on the Pressure Change of the Bootstrap type Reservoir in the Aircraft (자체여압 형 항공기용 저장조의 온도 및 습도에 따른 내부압력 변화에 관한 실험적 연구)

  • Kim, Jung-Sik;Yu, Han-Sik;Park, Dong-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.170-175
    • /
    • 2013
  • For this study, the domestically developed bootstrap reservoir of the aircraft is set up in accordance with the temperature and humidity conditions depicted on the qualification test, and the variation in the internal pressure of the bootstrap reservoir of the aircraft is examined. The study shows that the bootstrap reservoir has less variation in the internal pressure at room temperature than at low temperature($-40^{\circ}C$). As a result, the internal pressure can be maintained stably when the temperature of working fluid in the bootstrap reservoir and the atmosphere environment is over room temperature($25^{\circ}C$). Therefore the keeping of temperature above room temperature is very important to operate the bootstrap reservoir of the aircraft properly.

Temperature variation in steel beams subjected to thermal loads

  • Abid, Sallal R.
    • Steel and Composite Structures
    • /
    • v.34 no.6
    • /
    • pp.819-835
    • /
    • 2020
  • The effects of atmospheric thermal loads on the response of structural elements that are exposed to open environments have been recognized by research works and design specifications. The main source of atmospheric heat is solar radiation, which dominates the variation of the temperature of air, earth surface and all exposed objects. The temperature distribution along the depth of steel members may differ with the geometry configuration, which means that the different-configuration steel members may suffer different thermally induced strains and stresses. In this research, an experimental steel beam was instrumented with many thermocouples in addition to other sensors. Surface temperatures, air temperature, solar radiation and wind speed measurements were recorded continuously for 21 summer days. Based on a finite element thermal analysis, which was verified using the experimental records, several parametric studies were directed to investigate the effect of the geometrical parameters of AISC standard steel sections on their thermal response. The results showed that the overall size of the beam, its depth and the thickness of its elements are of significant effect on vertical temperature distributions and temperature differences.