• Title/Summary/Keyword: Temperature transmission

Search Result 1,623, Processing Time 0.03 seconds

Digital Transmission and Isolation of Multichannel Analog Signals using a Single Optocoupler (옵토커플러의 절연을 이용한 멀티채널 아날로그 신호의 디지털 전송)

  • Nam, Jin Moon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.4
    • /
    • pp.379-385
    • /
    • 2018
  • The transmission of analog signals through Galvanic isolators often results in signal distortion. Optocoupler gain is temperature dependent and also varies considerably, which would cause deformations of analog signals. Digital isolators have better noise immunity than analog, and digital transmission is a cost-effective noise rejection method for multichannel analog signals, which can solve temperature-induced signal distortion problems. Digital data, converted from multichannel analog signals, can be transmitted through a single optocoupler. We proposed advanced circuits and data frame for robust transmission of multichannel analog signals. Numerical experiments were performed to investigate distortion of multichannel analog signals during transmission.

Development for body temperature sensor and monitoring telemetry system (체온측정용 온도 센서 및 모니터링 텔레메트리 시스템 구현)

  • Lee, Jyung-Hyun;Seong, Ki-Woong;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.435-442
    • /
    • 2010
  • Typically, the vital signs that are representing the state of human body, are the body temperature, sphygmus, respiration and blood pressure. The body temperature is the result of metabolic regulation and human steady-state body temperature is maintained from 35.9 to $37.4^{\circ}C$ by heat regulatory center. The body temperature is indicative of infection and especially it should be monitored to requiring intensive care patients or after surgical patients. But, measuring of body temperature to a heavy workload on nursing staff has been recognized. And, the health service of nurse is limited by simple tasks such as the measurement and record of vital sign. In this paper, the body temperature monitoring telemetry system was proposed to prove the recoding and transmission of body temperature patch system according the standard(ISO TS11073-92001). We proposed the transmission protocol to suit the MFER(medical waveform format encoding rules). The telemetry patch system was implemented and it was verified by experiments.

ESTIMATION TECHNIQUE Of AIR CONTENT IN TUTOMATIC TRANSMISSION FLUID BY MEASURING EFFECTIVE BULK MODULUS

  • Cho, Baek-Hyun;Lee, Hyoun-Woo;Oh, Jong-Sun
    • International Journal of Automotive Technology
    • /
    • v.3 no.2
    • /
    • pp.57-62
    • /
    • 2002
  • It is well known that the entrained air in oil causes appreciable reduction in the stiffness of hydraulic systems. It makes the response delay of the systems and sometimes destroys the stability. Because the hydraulic systems of automatic transmissions are operated in relatively low pressure and high temperature, it is very important to analyze the effects of the air included in automatic transmission fluid. However, it is difficult to derive the generalized model to describe the effective bulk modulus theoretically or measure it in actual operating conditions of automatic transmissions. This paper reviews previous studies of the air effects in hydraulic systems and the measurement techniques of the effective bulk modulus in operating conditions. Based on this work, the theoretical model with moderate complexity and the measurement technique of the effective bulk modulus considering entrained air effect at real operating conditions are suggested. Our paper also shows that the quantity of the entrained air in the automatic transmission fluid can be estimated from the experimental results.

Simultaneous Measurement of Temperature and Refractive Index of a Medium Using by a Side-Polished Fiber Containing a Fiber Bragg Grating (광섬유 브래그 격자가 포함된 측면 연마된 광섬유를 이용한 매질의 온도와 굴절률 동시 측정)

  • Kim, Kwang Taek
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.8
    • /
    • pp.513-517
    • /
    • 2015
  • We proposed and demonstrated a simultaneous measurement method to detect the refractive index and temperature of a medium using a side-polished fiber involving FBG (fiber Bragg grating). The temperature of a medium was obtained by using the Bragg wavelength shift of FBG, while the refractive index of medium were calculated by using the transmission loss. The Bragg wavelength is independent on the refractive index of the covering medium placed on surface of side-polished fiber, while the transmission loss at off-Bragg wavelength highly depends on the environmental temperature because of thermo-optic effect of the medium.

Experimental Study of Moisture Vapor Transmission Rate(MVTR) for Breathable Film (통기성필름의 투습도에 관한 실험적 연구)

  • Choi, Man Sung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Moisture vapor transmission rate (MVTR) is an important item for many applications of polymer breathable thin film. To determine the optimum values of the process parameters, it is essential to find their influence on The significance of six important process parameters namely, extruder cylinder temperature, extruder speed, extruder dies temperature, cooling roll temperature, stretching ratio, stretching roll temperature on breathable film strength of polymer extrusion was determined. Moreover, this paper presents the application of Taguchi method and analysis of variance (ANOVA) for maximization of the breathable film MVTR influenced by extrusion parameters. The optimum parameter combination of extrusion process was obtained by using the analysis of signal-to-noise ratio. The conclusion revealed that extruder speed and stretching ratio were the most influential factor on the film strength, respectively. The best results of film MVTR were obtained at higher extruder speed and stretching ratio.

Application of the Through-Transmitted Ultrasonic Signal for the Identification of Two-Phase Flow Patterns in a Simulated High Temperature Vertical Channel

  • Chu In-Cheol;Song Chul-Hwa;Baek Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.12-23
    • /
    • 2004
  • In the present study a new measurement technique has been developed, which uses an ultrasonic transmission signal in order to identify the vertical two phase flow pattern. The ultrasonic measurement system developed in the present study not only provides the information required for the identification of vertical two phase flow patterns but also makes real time identification possible. Various vertical two phase flow patterns such as bubbly, slug, churn, annular flow etc. have been accurately identified with the present ultrasonic measurement system under atmospheric condition. In addition, the present test apparatus can practically simulate the ultrasonic propagation characteristics under high temperature and high pressure systems. Therefore, it is expected that the present ultrasonic flow pattern identification technique could be applicable to the vertical two phase flow systems under high temperature and high pressure conditions.

Study on Thermal Stress of Porcelain Insulator for T/L (송전용 자기애자의 열충격 특성 연구)

  • Han, Se-Won;Cho, Han-Goo;Choi, In-Hyuk;Lee, Dong-Ill
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.208-209
    • /
    • 2006
  • This study presents the thermal stress characteristics of TL porcelain insulators(healthy and ageing) by the accelerating thermal mechanical ageing test with forced temperature gradient. The test temperature gradient is $95^{\circ}C(-35{\sim}60^{\circ}C)$, it was focused to high temperature thermal stress as compared with IEC 60575 standard. There was no a discrimination in the case of healthy aluminous porcelain insulators, dissimilarly in crystoballite insulators according to this test method. It was indicated that the long tenn reliability by thermal stress was conformed reasonably through the conventional accelerating ageing test methods.

  • PDF

A TWO CAVITY MODEL FOR UMBRAL OSCILLATIONS

  • Lee, Jeong-Woo;Yun, Hong-Sik
    • Journal of The Korean Astronomical Society
    • /
    • v.20 no.1
    • /
    • pp.27-47
    • /
    • 1987
  • In the present study a two-mode, separately concurring resonant cavity model is proposed for theoretical interpretation of the 3 minute umbral oscillation. The proposed model has been investigated by calculating the transmission coefficients of the waves propagating through the umbral photosphere (photospheric weak-field cavity) and chromosphere (chromospheric strong-field cavity) into the corona, for 3 different umbral model atmospheres by Staude (1982), Beebe et al. (1982) and Avrett (1981). In computing the transmission coefficients we made use of multi-layer approximation by representing the umbra] atmosphere by a number of separate layers with (1) temperature varying linearly with depth and (2) temperature constant within each layer. The medium is assumed to be compressible, non-viscous, perfectly conducting under gravity. The computed resonant periods, transmission spectra, phase spectra, and kinetic energy density of the waves associated with the oscillations are presented in comparison with the observations and their model dependent characteristics are discussed.

  • PDF

An Optimal Cooling Method for Long HTS Power Transmission Cable (고온초전도 케이블 냉각길이 장척화를 위한 최적 냉각방안)

  • Lee Chang-Ho;Kim Do-Hyung;Kim Chun-Dong;Kim Kyun-Seok;Kim Ig-Saeng
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.3
    • /
    • pp.56-61
    • /
    • 2004
  • An optimal cooling method for a long HTS power transmission cable was scrutinized by using theoretical models. Cooling length of HTS cable is determined by pressure range and temperature range of LN2 in the HTS cable. Results showed limitation from temperature range is stricter than that from pressure range. The well-known one-side cooling was modified to two-side cooling. It was shown that cooling length can be nearly doubled by adopting two-side cooling of the same capacity.

The Wearing Sensation of Men and Women in Sports Wear with Waterproof and Water Vapor Permeable Fabrics (성인 남녀의 투습방수소재 스포츠 웨어의 소재별 착용감에 관한 연구)

  • Cho, Ji-Hyun;Ryu, Duck-Hwan
    • Korean Journal of Human Ecology
    • /
    • v.9 no.1
    • /
    • pp.47-61
    • /
    • 2000
  • The purpose of this study was to examine the performance and properties of sports wear that have the excellent wearing sensation and are in harmony with the functions of human bodies. With four kind(sample A, B, C, D) of materials which have different water vapor transmission, the physiological responses of human bodies and the changes of subjective sensations were studied through the actual aerobic sports program at $20^{\circ}C$, 60%R.H. The forehead temperature had the minimal variation among the local skin temperatures. The fabrics of low water vapor transmission demonstrated high breast temperature. There are significant differences among materials depending on the humidity in clothes(especially back and breast), which was about 6 % for breast and about 14 % for back. The order of loss in body weight was in the opposite direction to that of water vapor transmission for each material.

  • PDF