• Title/Summary/Keyword: Temperature transmission

Search Result 1,623, Processing Time 0.033 seconds

Accelerating Aging of Transmission Line Porcelain Suspension Insulators by Autoclaving

  • Lee, Won-Kyo;Choi, In-Hyuk;Shin, Koo-Yong;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.147-150
    • /
    • 2008
  • Porcelain suspension insulators aged for 1, 5 and 10 years on Korean transmission lines and new insulators are tested for autoclave expansion. The compressive strength of the insulators aged in an autoclave with conditions of $250\;^{\circ}C$ and at 20 atm for 30 minutes, was about $7.6\;kgf/mm^2$, which is close to that measured on insulators aged for 10 years in the field. From simulation results, the cement displacement changed linearly with temperature. At a temperature of $200\;^{\circ}C$, the shear stress was approximately $7\;kgf/mm^2$; a stress that is brought about by a 0.07 % expansion of the cement. It is evident that the cement would fracture at a 0.07 % expansion, because the cement has about 7 to $9\;kgf/mm^2$ flexure strength. A turning point in the shear stress with mechanical load occurred at 0.02 % cement expansion. From an analysis of the porcelain body it is shown that there is sufficient margin of strength to guard against fracture of the porcelain body even for a cement expansion more than 0.12 %.

Changing Transmission Pattern of Plasmodium vivax Malaria in the Republic of Korea: Relationship with Climate Change

  • Park, Jae-Won
    • Environmental Analysis Health and Toxicology
    • /
    • v.26
    • /
    • pp.1.1-1.6
    • /
    • 2011
  • Plasmodium vivax malaria has occurred annually in the Republic of Korea (ROK) since its re-emergence in 1993. P. vivax malaria in ROK has been strongly influenced by infected mosquitoes originating from the Democratic People's Republic of Korea. Korean P. vivax malaria has shown typical characteristics of unstable malaria transmitted only during the summer season, and displays short and long incubation periods. The changing pattern of the transmission period can be predicted by analyzing the seasonal characteristics of early primary attack cases with a short incubation period. Such cases began to gradually occur earlier in the 1990s after the re-emergence. Most of the malaria cases after mid-August are presumed to be early primary attack, short incubation period cases. Only primary transmission was possible until the early 2000s, whereas up to fourth or fifth transmission occurred in the mid-2000s. The results indicate that the length of transmission period has been gradually extending, which may be ascribed to a climate change-mediated temperature rise. Malaria and climate data should be integrated to analyze and predict the influence of climate change on malaria occurrence in ROK.

Experimental Examinations on the Phenomenon of Transfer and Moisture Diffusion in Wood (목재내(木材內)의 수분확산(水分擴散) 및 전달현상(傳達現象)에 관한 실험적 검정(檢定))

  • Lee, Weon-Hee
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.75-80
    • /
    • 1996
  • The purpose of this study is to clarify the mechanism of moisture transfer depend on the thickness of the spruce(Picea sitchensis Carr.). Therefore, as the basic research of moisture transmission, the amount of moisture transmission and the moisture distribution in specimens and temperature of it's surfaces in vapor transmission process were investigated. The experiment was conducted in a steady state. and the moisture distribution was measured by knife cutting and weighing the specimens. The following conclusions were obtained ; 1. It can be found that distribution of moisture in the specimen can be approximated by two different straight lines intersecting at nine or ten percent moisture content. The amount of moisture movement defends on the gradient of moisture in the wood. 2. It is investigated that the wood surface moisture contents(MCs) are less for thinner specimens than for thick ones on the absorption side. On the other hand, the wood surface MCs are greater for thinner specimens than for thick ones on the desorption side. The main factor that affects the EMC of wood would be temperature when the relative humidity of atmosphere is constant. The specimen generate heat with the absorption and desorption process. In addition, the velocities of moisture transmission varied with the thicknesses of specimens. If the temperature of wood becomes greater, its MC decreases. Then the difference between surface MC and EMC of adsorption and desorption side becomes greater for thinner specimens. Therefore it is considered that the coefficients of moisture transfer decreases with the increases of the specimens' thicknesses.

  • PDF

New DTR Estimation Method Without Measured Solar and Wind Data

  • Ying, Zhan-Feng;Chen, Yuan-Sheng;Feng, Kai
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.576-585
    • /
    • 2017
  • Dynamic thermal rating (DTR) of overhead transmission lines can provide a significant increase in transmission capacity compared to the static thermal rating. However, the DTR are usually estimated by the traditional thermal model of overhead conductor that is highly dependent on the solar, wind speed and wind direction data. Consequently, the estimated DTR would be unreliable and the safety of transmission lines would be reduced when the solar and wind sensors are out of function. To address this issue, this study proposed a novel thermal model of overhead conductor based on the thermal-electric analogy theory and Markov chain. Using this thermal model, the random variation of conductor temperature can be simulated with any specific current level and ambient temperature, even if the solar and wind sensors are out of function or uninstalled. On this basis, an estimation method was proposed to determine the DTR in the form of probability. The laboratory experiments prove that the proposed method can estimate the DTR reliably without measured solar and wind data.

Numerical Analysis of Heat Flow and Thermal Deformation in Transmission Joining of Polymers Using Nd:YAG Laser (Nd:YAG 레이저를 이용한 폴리머의 투과접합에서 열 유동 및 열 변형 해석)

  • Cha, Sang-Woo;Kim, Jin-Beom;Na, Suck-Joo
    • Journal of Welding and Joining
    • /
    • v.24 no.6
    • /
    • pp.28-32
    • /
    • 2006
  • Laser Transmission Joining (LTJ), which is a joining process of polymers by using different transmission rates of materials, was studied numerically. Unlike previous studies, energy loss by reflection at the surface was included. Besides, energy absorbed in the transparent substrate is also considered to increase the accuracy of the analytical results. Furthermore, thermal deformations of the substrates were also calculated. Temperature distribution of the substrates on the joining process could be effectively predicted by using the thermal analysis model developed, which could also analyze the rising phenomenon of the absorbing substrate by bulge effect. Calculated results show that temperature of the absorbing substrate is higher than that of transparent substrate when the laser is being radiated, and this temperature difference causes more thermal deformation in absorbing substrate, which results in the surface rise of the absorbing substrate. Comparison of calculated results with corresponding experimental results could confirm the validity of the numerical analysis model proposed.

SIMULATION OF A HYDRAULIC CONTROL SYSTEM FOR POWERSHIFT TRANSMISSION OF TRACTORS

  • Kim, D. C.;Lee, H. S.;Kim, K. U.;Y S. Nam
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.498-505
    • /
    • 2000
  • Performance of a hydraulic system is influenced by its working temperature. Therefore, it is very important to make the system perform uniformly in an entire range of the working temperature. In this study a simulation of a hydraulic control system for the powershift transmission of tractors was conducted and the effect of the temperature was investigated in terms of design conditions of the system. Results of the simulation are as follows. The hydraulic control system with a spring accumulator was found to be more convenient to control the shifting time than that with a gas accumulator. By returning the oil from the clutches to the system through a path between the filter and pump, the time delay due to the pressure difference between the low and high temperatures could be reduced. Therefore, it was recommended that the hydraulic control system for the powershift transmission of tractors must be equipped with a spring accumulator and a circuit to return oil from the clutches to the system through a path between the filter and pump.

  • PDF

Two Factors Failure Model of Oil-Paper Insulation Aging under Electrical and Thermal Multistress

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.957-963
    • /
    • 2014
  • Converter transformers play important roles in high-voltage direct current transmission systems. This paper presents experimental and analysis results of the combined electrical and thermal aging of oil-impregnated paper at pulsating DC voltages. Breakdown voltages and time-to-breakdown of oil-paper specimens were measured by using short-time and constant-stress tests. The breakdown characteristics of combined electrical and thermal aging on insulation system were discussed. According to the relationship between failure time and aging temperature, the two-parameter Weibull model was improved. On the basis of the competing risk algorithm and the improved Weibull model, the two factors failure model was calculated. And the influence of temperature in the insulation system has been analyzed. This model performs better than the two-parameter Weibull model when both time and temperature are considered as variables in estimating the lifetime of oil-paper insulation.

Design of a laboratory-scale superconducting DC transmission line (모델급 초전도 직류 송전 선로의 설계)

  • Kim, Sung-Kyu;Dinh, Minh-Chau;Park, Minwon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1102-1103
    • /
    • 2015
  • The researchers worldwide have been trying to apply high temperature superconducting wire for power system devices. High voltage direct current (HVDC) transmission system has been used for bulk and long-distance power transmission. The authors designed a laboratory-scale superconducting DC transmission line to investigate its applicability to an HVDC system. The superconducting DC transmission line was simulated in connection to a laboratory-scale HVDC system using PSCAD/EMTDC. The operating characteristics of the superconducting DC transmission line connected to HVDC system and the effects of the superconducting DC transmission line on HVDC system were analyzed and compared with the results of a conventional DC transmission line. The results of operating characteristics for the superconducting DC transmission line were discussed in detail.

  • PDF

An Adaptive Transmission Scheme Based on Interference Temperature Cognition for Cognitive Radio Systems (Cognitive Radio 시스템을 위한 간섭온도 인지 기반의 적응전송 기법)

  • Hong, Min-Ki;Kim, Jae-Woon;Kim, Hyun-Wook;Shin, Yo-An
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.9C
    • /
    • pp.826-833
    • /
    • 2007
  • In this paper, we present an adaptive transmission system model to establish the baseline for wireless adaptive transmission using CR (Cognitive Radio) systems, and propose an adaptive transmission scheme based on IT (Interference Temperature) cognition for CR systems in the presented system environment. The proposed CR adaptive transmission scheme is the method that provides the CR user with the maximum transmit power in the range of not causing any interference to the incumbent user and guaranteeing the optimal throughput by applying CR-AMC (CR-Adaptive Modulation and Coding) in the given channel state. Simulation results show that in case of using the proposed CR adaptive transmission scheme, there is little degradation of BER performance, while causing no interference to the incumbent user. At the same time, the proposed scheme guarantees the optimal throughput to the CR user in the given channel state.

Thermal Impact Characteristics by Forest Fire on Porcelain Insulators for Transmission Lines

  • Lee, Won-Kyo;Choi, In-Hyuk;Choi, Jong-Kee;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.143-146
    • /
    • 2008
  • In this study the thermal impact characteristics by forest fire are extensively investigated using temperature controlled ovens. The test conditions for thermal impact damage are simulated according to the characteristics of natural forest fire. The test pieces are suspension porcelain insulators made by KRI in 2005 for transmission lines. In the thermal impact cycle tests with $300\;^{\circ}C$ thermal impact gradient (-70 to $230\;^{\circ}C$), cycling in 10 minute periods, no critical failures occurred in the test samples even with long cycle times. But in tests with thermal impact gradient from room temperature to $200-600\;^{\circ}C$, cycling in 10 to 30 minute periods, there were critical failures of the porcelain insulators according to the thermal impact gradient and quenching method. In the case of thermal impact by forest fire, it was found of that duration time is more important than the cycling time, and the initiation temperature of porcelain insulator failures is about $300\;^{\circ}C$, in the case of water quenching, many cracks and fracture of the porcelain occurred. It was found that the thermal impact failure is closely related to the displacement in the cement by thermal stress as confirmed by simulation. It was estimated that the initiation displacement by the thermal impact of $300\;^{\circ}C$ is about 0.1 %. Above 1% displacement, it is expected that the most porcelain insulators would fail.