• Title/Summary/Keyword: Temperature test equipment

Search Result 330, Processing Time 0.032 seconds

Effect of Different Exercise Intensity on Blood Melatonin Density in Sleep Disordered Rats (운동 강도가 수면장애 모델 쥐의 혈 중 멜라토닌 농도에 미치는 영향)

  • Kim, Hee-Jung;Kim, Dong-Hyun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.1
    • /
    • pp.45-53
    • /
    • 2014
  • PURPOSE: In this study, we tried to find out what kind of exercise was more effective in sleep disorder by comparing melatonin in blood after applying low intensity with high intensity exercise to sleep disordered rats induced by experiment. METHODS: We used male Sprague-Dawley rats which were 8weeks old and weighted 300g. They were supplied with water and food without any restriction. We kept the room temperature at $25^{\circ}C$ and controld the length of day and night in 12 hours blocks, respectively. We divided the rats 60 into 2 groups. To one group we applied low intensity exercise, and to the other we applied high intensity exercise for 15minutes per day over a period of 4 weeks. We extracted the blood from abdominal aorta before, after exercise, moved into EDTA tube, performed centrifugation. We decanted the serum $200{\mu}l$ from the blood into microcentrifuge tube by samples and moved into polypropylene culture tubes with micro pipette. We split enzyme solution $50{\mu}l$ into the tubes with melatonin direct kits and make them react at $37^{\circ}C$ for 2 hours. We split assay buffer $50{\mu}l$ into each tube and mixed melatonin tracer $50{\mu}l$ and melatonin antiserum $50{\mu}l$, respectively. After we made them react in room temperature, we decanted the superficial layer with a centrifuge and measured the activity for 1 minute by competitive method with ${\gamma}$-counter equipment. We draw a standard curve through logit-log graph with CPM(counts per minute) and counted the melatonin by B/B0. We conducted independent t-test to examine the homogeneous of melatonin value of before low-intensity and high-intensity exercise. We performed paired t-test to compare before and after low-intensity and high-intensity exercise, respectively. We carried out independent t-test to compare melatonin value after low-intensity and high-intensity exercise. Significance level was .05. RESULTS: The results were as follows; firstly melatonin was more increased in the group who was exposed to high intensity exercise when we compared before to after high and low intensity exercise, respectively. Secondly, high intensity exercise was more effective than low intensity exercise when we compared the two. CONCLUSION: In conclusion, secretion of melatonin which is the material of sleep improvement could be promoted by high intensity exercise. Low intensity exercise acted as a stress rather than improving sleep and had a negative effect on the secretion of melatonin because the melatonin was affected by stress.

Design and Verification of Housing and Memory Board for Downsizing for Crash Protected Memory Module (충돌보호메모리모듈의 소형화를 위한 하우징 및 메모리 보드 설계와 검증)

  • Kim, Jun-Hyoung;Kim, Jung-Pil;Kim, Jeong-Yeol;Kim, Tae-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.1
    • /
    • pp.81-88
    • /
    • 2020
  • Flight data recorder is a equipment that records data required for investigation of aircraft accidents and should be developed in compliance with the ED-112A standard. Unlike general data storage device, flight data recorder must be able to recover data after an aircraft accident, requiring a housing and a memory board to protect data in extreme environments. To attain this performance, we designed a housing that can withstand the test by analyzing the physical environment of the impact, shear/tensile, penetration resistance and static crush test of the crash survival test and minimized the size and weight compared to the existing one in consideration of the installation of the aircraft in this paper. Insulation material and thermal block material were applied to endure high and low temperature fire so that the internal temperature does not rise above 150℃ even in 260℃, 10 hour environment. In addition, the memory board is designed to minimize the size and we devise a hoping programming method to prevent continuous data loss of more than 16 seconds. Through this, Crash protected memory module that satisfies ED-112A was completed.

Suggestion for Determination of Minimum $S_D$ for Rut-Resistable Asphalt Concretes (고온 내변형 아스팔트혼합물 선정을 위한 변형강도 임계치 결정 방안)

  • Kim, Kwang-W.;Cho, Byung-J.;Lee, Soon-Jae;Doh, Young-S.
    • International Journal of Highway Engineering
    • /
    • v.9 no.4
    • /
    • pp.193-204
    • /
    • 2007
  • Deformation strength($S_D$) is a property which shows relatively good correlation with rut resistance of asphalt mixtures at high temperature. The Asphalt Pavement Analyzer (APA) is widely used as an equipment for estimating rut resistance of asphalt mixtures. The APA was used as corresponding property of the $S_D$ to estimate rutting resistance of asphalt mixtures. Many data were collected to establish the correlation of $S_D$ with APA. For $S_D$ test, the specimen is submerged into the $60^{\circ}C$ water for 30 minutes before applying a vertical load at the speed of 50mm/min to obtain peak load (P) and deformation (y) for $S_D$ calculation. For the same materials, APA test was performed. Relation of the $S_D$ with APA rut depth was evaluated using regression analysis. The $R^2$ value was 0.76, indicating this simple test procedure being a possible method for predicting deformation resistance of asphalt concretes at high temperature. It was also shown that, using the regression model, minimum value(s) of $S_D$ of surface course asphalt mixture or binder course for a particular road level can be determined. The limit values may be possible to use as cut-off value(s) of asphalt mixtures for the layer after further elaborated studies.

  • PDF

Analysis of Electrical Characteristics of CCFL Exit Light (CCFL유도등의 전기적 특성 분석)

  • Jung, Jong-Jin
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.184-193
    • /
    • 2021
  • Purpose: In this study, since the operation principle of the CCFL Exit light is the same as that of general lighting equipment, the characteristics of the CCFL Exit light were analyzed by deriving test items that can affect the characteristics of the light source from the KS standard, which is the standard for lamp ballast performance certification of general lighting equipment. Method: The samples used in the experiment were performed on products of two manufacturers for each size, such as large, medium, and small, and the test items were power factor, crest factor, and current harmonic distortion. Result: As a result of the experiment, the power factor showed a value between 0.4 and 0.6 in all samples, which was smaller than the 0.9 value set by KS. The crest factor ranged from 3.6 to 3.7 for large, 4.4 to 4.7 for medium, and 3.5 to 3.7 for small. It showed a value more than two times higher than the KS standard of 1.7. Current total harmonic distortion ranged from 81% to 110%, and considering that the KS standard was less than 20%, it could be confirmed that all samples had a value significantly exceeding the KS standard. Conclusion: The crest factor and current total harmonic distortion may affect the temperature rise of the light source and the burnout of the device. When developing an exit light, if this item is developed within the scope of the KS standard, the quality improvement and maintenance of the exit light will be greatly improved.

Examination of Strain Model Constants considering Strain Properties at High Temperature of Ultra-high-strength Concrete (초고강도 콘크리트의 고온 변형 특성을 고려한 변형모델 상수 검토)

  • Hwang, Eui-Chul;Kim, Gyu-Yong;Choe, Gyeong-Cheol;Yoon, Min-Ho;Lee, Bo-Kyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.91-97
    • /
    • 2016
  • Evaluation on the test of actual concrete member to confirm the fire resistance of the concrete member using ultra-high strength concrete is required. However, test equipment which has large loading capacity is needed to the actual member experiment. So, many researchers evaluated the fire performance through analytical studies using the material models. This study experimentally evaluated strain properties on ultra-high-strength concrete of 80, 130 and 180 MPa with heating and examined to apply the existing strain model about ultra-high-strength concrete. As a results, constants are drawn by method of least squares applying experimental values and calculated values by the existing strain model, it proposed strain model that can be applied to ultra-high-strength concrete.

Effect of Cr content on the FAC of pipe material at 150℃ (150℃에서 원전 2차측 배관재료의 Cr함량에 따른 유체가속부식 특성)

  • Park, Tae Jun;Kim, Hong Pyo
    • Corrosion Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.274-279
    • /
    • 2013
  • Flow accelerated corrosion (FAC) of the carbon steel piping in nuclear power plants (NPPs) has been major issue in nuclear industry. During the FAC, a protective oxide layer on carbon steel dissolves into flowing water leading to a thinning of the oxide layer and accelerating corrosion of base material. As a result, severe failures may occur in the piping and equipment of NPPs. Effect of alloying elements on FAC of pipe materials was studied with rotating cylinder FAC test facility at $150^{\circ}C$ and at flow velocity of 4m/s. The facility is equipped with on line monitoring of pH, conductivity, dissolved oxygen(DO) and temperature. Test solution was the demineralized water, and DO concentration was less than 1 ppb. Surface appearance of A 106 Gr. B which is used widely in secondary pipe in NPPs showed orange peel appearance, typical appearance of FAC. The materials with Cr content higher than 0.17wt.% showed pit. The pit is thought to early degradation mode of FAC. The corrosion product within the pit was enriched with Cr, Mo, Cu, Ni and S. But S was not detected in SA336 F22V with 2.25wt.% Cr. The enrichment of Cr and Mo seemed to be related with low, solubility of Cr and Mo compared to Fe. Measured FAC rate was compared with Ducreaux's relationship and showed slightly lower FAC rate than Ducreaux's relationship.

A Study on the Development of Large Aluminum Flange using Casting/Forging Process (주조/단조 기술을 이용한 대형 알루미늄 플랜지 개발에 관한 연구)

  • 배원병;왕신일;서명규;조종래
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.905-909
    • /
    • 2001
  • The significance of casting/forging process for reducing the production cost of large components is being noted in these days. This casting/forging process is a method of forging a workpiece preformed by casting into the final shape. In this study, the casting/forging process has been applied in manufacturing a large aluminum flange in order to determine the optimum forging condition of the aluminum flange. The optimum range of forging temperature of Al 5083 was from $420^{\circ}C$ to $450^{\circ}C$. The suitable strain rate was 1.5 $sec^{-1}$. The deformation amount of a preform in a forging process is key role in the mechanical properties of casting/forging products. In order to find the change of mechanical properties according to effective stain of cast aluminum billets, a hot upsetting test were performed with rectangular blocks and then a uniaxial tensile test was performed with specimens cut from the upsetted billets. The tensile strength and the elongation of cast/upsetted aluminum billets were increased largely until the effective strain was 0.7. FE analysis was performed to determine the configurations of cast preform and die for an aluminum flange. In the FE analysis, the forging load-limit was fixed 1500ton for the low equipment cost. The cast preform was designed so that the effective stain around the neck of a flange exceeds 0.7. In the forging experiment for an aluminum flange, it was confirmed that the optimal configuration of the cast preform predicted by FE analysis was very useful. The cast/forged products using designed preform were made perfectly without any defects.

  • PDF

Speckle Noise Reduction of Ultrasonic NDT Using Adaptive Filter in WT Domain (웨이브렛 변환 평면에서 적응 필터를 이용한 초음파 비파괴검사의 스펙클 잡음 감소)

  • Jon, C.W.;Jon, K.S.;Lee, Y.S.;Lee, J.;Kim, D.Y.;Kim, S.H.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.21-29
    • /
    • 1996
  • Industrial equipment, such as power plant, is required to operate reliably, continuously and economically under rather severe conditions of temperature, stress, and enbironment. To test structural integrity and fitness, ultrasonic nondestructive testing is used because of effectiveness and simplicity. In this paper, wavelet transform based least mean square(LMS) algorithm is applied to reduce the influence of the interference occurring between randomly positioned small scatters. The RUN test is performed to check the nonstationarity of the speckle noise signal. The performance of this new approach is compared with that of the time domain LMS algorithm by means of condition numbers, signal-to-noise ratio and 3-D image. As a result, the wavelet transform based LMS algorithm shows better performance than the time domain LMS algorithm in this experiment.

  • PDF

Study on Production of Power Monitoring Unit for Electric Propulsion UAV (전기동력 무인항공기용 PMU의 개선 및 제작에 대한 연구)

  • Kang, Jin-Myeong;Jeong, Jin-Seok;Kang, Beom-Soo;Kim, Jang-Mok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.2
    • /
    • pp.140-147
    • /
    • 2017
  • This paper describes the design and implementation of previously developed PMU (Power Monitoring Unit) for LiPB (Lithium-ion Polymer Battery) that is electric propulsion used as unmanned aerial vehicle's power source. Improved PMU provides stable voltage and current to various sensors and elctric motors necessary during flight. Voltage and current monitoring function that is measured by improved PMU more precisely be enhanced and the monitoring channel and temperature sensor is added. To verify the improved performance of the equipment, it is integrated to electric propulsion system of unmanned aerial vehicle. PMU is calibrated through the ground test. And PMU's performance is checked through the flight test.

Development of Automated Ultrasonic Testing System for Partial Joint-Weld of Heat Exchanger's Header to Tube in Power Plant (발전소 열교환기 헤더와 튜브의 부분 용입형 용접부 초음파 자동검사시스템 개발)

  • Lee, Jin-Hyuk;Lim, Seong-Jin;Park, Ik-Keun;Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.367-372
    • /
    • 2010
  • A power plant's heat exchangers work under poor conditions, such as high temperature, high pressure, corrosion, mechanical stress and vibration. Especially, partial joint-weld of heat exchanger's header to stub-tube is the place where incomplete penetration flaws can easily occur. But, it is hard to evaluate the safety of the structure by conventional nondestructive testing techniques. So it is necessary to test integrity of the weld inside and to develop testing technique and equipment that can detect the flaws at the weld point in order to enhance reliability of the test result. In this study, we developed a suitable automated ultrasonic testing system that can inspect the partial joint-weld of header to stub-tube of power plant. Finally, we showed the efficiency of the automated ultrasonic-testing-system from the application.