• Title/Summary/Keyword: Temperature of cooler

Search Result 353, Processing Time 0.026 seconds

Cycle Simulation of a Desiccant Cooling System with a Regenerative Evaporative Cooler (재생형 증발식 냉각기를 이용한 제습 냉방시스템의 성능해석)

  • 이재완;이대영;강병하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.566-573
    • /
    • 2004
  • Comparison of the cooling performance is provided between the desiccant cool-ing systems incorporating a direct evaporative cooler and a regenerative evaporative cooler, respectively. Cycle simulation is conducted, and the cooling capacity and COP are evaluated at various temperature and humidity conditions. The COP of the system with a regenerative evaporative cooler and the regeneration temperature of 6$0^{\circ}C$ is evaluated 0.65 at the outdoor air condition of 35$^{\circ}C$ and 40% RH. This value is found about 3.4 times larger than that of the system with a direct evaporative cooler. Furthermore, incorporating a regenerative evaporative cooler eliminates the need for deep dehumidification in a desiccant dehumidifier that is necessary to achieve low air temperature in the system with a direct evaporative cooler. Subsequently, the regenerative evaporative cooler enables the use of low temperature heat source to regenerate the dehumidifier permitting the desiccant cooling system more beneficial compared with other thermal driven air conditioners.

An Effect on the Solution Crystallization Temperature Difference and Cooling Capacity of the Absorption Chiller by a Solution Cooler in the Absorber (흡수기내 용액 냉각기가 흡수식 냉동기의 용액 결정화 온도차와 냉각 용량에 미치는 효과)

  • Chin, Sung-Min;Lee, Jae-Heon;Jurng, Jong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1518-1523
    • /
    • 2003
  • The objective of the present work is to investigate an effect on the solution crystallization temperature difference and the cooling capacity of the absorption chiller by a solution cooler in the absorber. The cooling capacity of the absorption chiller can be higher, with the enhanced performance of the solution heat exchangers. But, because the solution crystallization temperature difference becomes smaller at the absorber inlet, the heat capacity of the solution heat exchangers might be limited by the danger of crystallization, which can cause the serious damages. In this paper, the heat capacity ratio of the solution cooler is defined as the ratio of the heat capacity of the solution cooler to that of the absorber. If it becomes larger in the additional type solution cooler, the solution crystallization temperature difference is augmented and the cooling capacity is also increased.

  • PDF

Temperature Control of a Test Plate for Semiconductor Using a Cooler and a Heater (Cooler와 Heater를 이용한 반도체 시험용 Plate의 온도제어)

  • 이호준;전창완;심용재;심운용
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.320-320
    • /
    • 2000
  • In this paper, a temperature controller of a test plate for semiconductor is developed using LQG/LTR methodology. The liquid is heated or cooled in a tank by a heater of a cooler. The controller controls the flow of heated or cooled liquid in the plate by controling an electronic valve. The developed controller is applied to the plate designed for function test of a semiconductor under high or low temperature environment. As a result, control using the heater and the cooler together shows better control performance than using the heater or the cooler separately.

  • PDF

Temperature Control for an Oil Cooler System Using PID Control with Fuzzy Logic (퍼지 적용 PID제어를 이용한 오일쿨러 시스템의 온도제어)

  • 김순철;홍대선;정원지
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.87-94
    • /
    • 2004
  • Recently, technical trend in machine tools is focused on enhancing of speed, accuracy and reliability. The high speed usually results in thermal displacement and structural deformation. To minimize the thermal effect, precision machine tools adopt a high precision cooling system. This study proposes a temperature control for an oil cooler system using Pill control with fuzzy logic. In the cooler system, refrigerant flow rate is controlled by rotational speed of a compressor, and outlet oil temperature is selected as the control variable. The fuzzy control rules iteratively correct PID parameters to minimize the error and difference between the outlet temperature and the reference temperature. Here, ambient temperature is used as the reference one. To show the effectiveness of the proposed method, a series of experiments are conducted for an oil cooler system of machine tools, and the results are compared with the ones of a conventional Pill control. The experimental results show that the proposed method has advantages of faster response and smaller overshoot.

The Characteristic of Inverter Control by Variation of Refrigeration Load and Outdoor Temperature on Industrial Cooler (외기온도와 부하변화에 따른 산업용 냉각기의 인버터제어 특성)

  • Baek, Seung-Moon
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.150-155
    • /
    • 2014
  • This paper presents The performance analysis of inverter control type-industrial cooler with respect to refrigeration load and outdoor temperature. Aside from materials about simulations and foundation data regarding inverter control compressors, currently, data about commercial coolers with inverter control still lack information for performance comparison. Thus, in this paper, the experiments are done to see characteristics of condensation capacity, evaporation capacity, compressor power and COP with respect to outdoor temperature and load by using a commercial inverter control cooler model. As a result, COP difference of the inverter control cooler with respect to load is 30% at the outdoor temperature of $35^{\circ}C$, 29% at the outdoor temperature of $30^{\circ}C$, 34% at $25^{\circ}C$, respectively.

Influence of Parameter Setting in an Oil Cooler on the Temperature Characteristics of an Ultra-precision Hydrostatic Table (초정밀 유정압 테이블에서 냉각장치의 변수 설정이 온도특성에 미치는 영향)

  • Khim, Gyungho;Kim, Chang Ju;Oh, Jeong Seok;Park, Chun Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.6
    • /
    • pp.571-576
    • /
    • 2015
  • Temperature characteristics of supply oil in an ultra-precision hydrostatic table are largely influenced by parameter setting in an oil cooler such as the location of reference sensor and cooling temperature. In this paper, influences of the parameter setting on the temperature variation in the hydrostatic table are experimentally analyzed to suggest the guidelines for practical application. In case of using temperature of inlet oil as a reference sensor in the oil cooler, temperature rise of the supply oil is smaller and thermal settling time is faster than that of using temperature of outlet oil as a reference sensor. The experimental results also show that temperatures of table, rail and return oil can be made almost same, and thermal settling time can be decreased by setting cooling temperature in the oil cooler to be lower than atmospheric temperature.

Evaluation of Thermal Fluid Characteristics for EGR Cooler with Spiral Type (Spiral 구조 EGR Cooler의 열유동 특성 평가)

  • 허형석;원종필;박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.44-50
    • /
    • 2003
  • Cooled EGR is an effective method for the reduction of NOx from a diesel engine and an EGR Cooler is the key component of the system. High efficiency, low pressure loss and compactness are required for the EGR Cooler. To meet these requirements, new geometric tube must be developed. In this paper, a full size EGR cooler test bench has been developed to validate the CFD flow and heat transfer models. Fluid temperature and pressure drop measurements are provided. fillet temperature is $200^{\circ}C$ and $300^{\circ}C$, and flow rates vary from 0.008 kg/sec to 0.019 kg/sec. The gas flow and heat transfer in a single tube cooler have been studied using computational fluid dynamics(CFD). Analysis has been carried out in a single tube with a plain tube and six spirally enhanced tubes of varying pitch to depth ratio(p/e).

Characteristics of Temperature Control in the Inverter Type Oil Coolers (인버터 타입 오일냉각기의 온도제어 특성에 관한 연구)

  • 이상호;이찬홍;박천홍
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.233-236
    • /
    • 2003
  • In this Paper, the temperature control error and cooling characteristics of inverter typ coolers are evaluated to predict application validity of coolers under heating pattern and amount The temperature control error of coolers small in 15~70% range of the max. cooling ability. At less than 15% of max. cooling ability has the inverter type cooler a basic temperature control error $\pm0.5^{\circ}C$ and acts as on/off type coolers. The inverter type cooler is unsuitable for precision temperature control under the complex heating pattern. But PID control of cooler including the heating system is an alternative for the case.

  • PDF

Performance Test for a Horizontal Regenerative Evaporative Cooler (수평형 재생증발식 냉방기의 성능시험)

  • Song, Gwi-Eun;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF

Characteristics of On-off Control and Hot-Gas Bypass Control in an Industrial Cooler (산업용 냉각기의 온오프 제어와 토출가스 바이패스 제어 특성 비교)

  • Baek, Seung-Moon;Moon, Choon-Geun;Kim, Eun-Pil;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.429-435
    • /
    • 2011
  • In this study the operational characteristics of the temperature control system between an on-offemployed cooler and a bypass type cooler is analyzed. Currently an on-off controller employed coolerwhich is the industry's leading type on the market for industrial coolers is used. The new type cooler isused a bypass controller at discharge gas. The COP of the bypass controlled cooler with discharge gas is at least 8% higher than the on-off controlled cooler. The maximum COP difference is about 20%. Based on the results, the bypass control with discharge gas shows the possible temperature control with high precision.