• 제목/요약/키워드: Temperature inversion

검색결과 302건 처리시간 0.02초

MOS소자 반전층의 전자이동도에 대한 해석적 모델 (An analytical model for inversion layer electron mobility in MOSFET)

  • 신형순
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권2호
    • /
    • pp.174-179
    • /
    • 1996
  • We present a new physically based analytical equation for electron effective mobility in MOS inversion layers. The new semi-empirical model is accounting expicitly for surface roughness scattering and screened Coulomb scattering in addition to phonon scattering. This model shows excellent agreement with experimentally measured effective mobility data from three different published sources for a wide range of effective transverse field, channel doping and temperature. By accounting for screened Coulomb scattering due to doping impurities in the channel, our model describes very well the roll-off of effective mobility in the low field (threshold) region for a wide range of channel doping level (Na=3.0*10$^{14}$ - 2.8*10$^{18}$ cm$^{-3}$ ).

  • PDF

습식 상 전이법으로 제조된 Theophylline 각인 대칭 막의 선택적 흡착 (Selective Adsorption of a Symmetrie Theophylline Imprinted Membrane Prepare by a Wet Phase Inversion Method)

  • 박중곤;오창엽;서정일
    • KSBB Journal
    • /
    • 제17권2호
    • /
    • pp.207-211
    • /
    • 2002
  • 습식 상 전환법으로 theophylline이 각인된 poly(acryloni-trile-co-acrylic acid) 막을 제조하였다. theophylline은 고분자가 공중합되는 과정에 각인시키거나(in-situ implanting) 제자리 동시 각인) 공중합된 고분자를 DMSO 용액에 녹이면서 template를 섞어 각인시켰다(post implanting, 후 각인). 막의 template molecule에 대한 흡착 선택도는 응고시키는 물의 온도가 높을수록, 혼합물의 초기 농도가 높을수록 크게 나타났다. 후 각인법으로 제조된 막의 흡착선택도가 제자리 동시각인 제작법으로 제조된 막보다 흡착선택도가 우수하였다.

분광 분석법에 의한 고압 수은등의 온도분포 측정 (Temperature Distribution Measurement of High-pressure Mercury Lamp using Spectroscopic Method)

  • 김상용;김창섭;지철근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1989년도 추계학술발표회논문집
    • /
    • pp.13-18
    • /
    • 1989
  • Temperature distribution of 250W high-pressure mercury lamp has been measured by the spectroscopic method using relative intensities of spectral lines. To obtain radial temperature distribution, the measured intensity which was integrated along the line of sight was transformed into radial line intensity by Abel's inversion. Temperature was determined from relative intensities of spectral lines of the same atomic species. The measured temperature of 250W high-pressure mercury lamp is 6000K at the axis. In this experiment temperature profile of high-pressure arc is papabolic as known.

  • PDF

Effect of two temperature and energy dissipation in an axisymmetric modified couple stress isotropic thermoelastic solid

  • Lata, Parveen;Kaur, Harpreet
    • Coupled systems mechanics
    • /
    • 제11권3호
    • /
    • pp.199-215
    • /
    • 2022
  • The present paper deals with the axisymmetric deformation in homogeneousisotropic thermoelastic solid with two temperatures, with and without energy dissipation using modified couple stresstheory. The effect of energy dissipation and two temperature isstudied due to the concentrated normalforce, normalforce overthe circularregion, thermal pointsource and thermalsource over the circular region. The Laplace and Hankel transform techniques have been used to find the solution to the problem. The displacement components, conductive temperature distribution, stress components and couple stress are computed in the transformed domain and further calculated in the physical domain using numerical inversion techniques. Effects of two temperature and energy dissipation on the conductive temperature,stress components and couple stress are depicted graphically.

초파리 집단내 역위빈도의 계절적 변동에 관한 연구

  • 이태훈;권국일;임낙룡
    • 한국동물학회지
    • /
    • 제31권4호
    • /
    • pp.327-333
    • /
    • 1988
  • 계절에 따른 초파리 집단내 역위다형 현상의 변동상을 알기 위하여 전주근교의 과수원에서 1983년 1월부터 11월까지 격월로 여섯번 채집한 집단 표본을 분석하였다. 총 1071마리에서 얻은 15개형의 역위는 모두 편동원체역위(paracentric inversion)였으며, 이 중 7개형은 세계형91위(cosmopolitan inversion)였고, 나머지 8개형은 지역형역위(endemic inversion)였다. 개체당 역위의 평균 보유수는 0.639이고 역위를 보유한 개체의 빈도는 0.465였다. 7개의 세계형역위에 대한 표본집단을 분석한 결과 격월 집단간에서 유의한 차이를 보이는 반면 1월과 1 1월 표본간에서는 그 성황이 오히려 비숫해짐으로서 집단내 총역위빈도는 주기적으로 변동하고 있음이 암시된다. 역위와 환경변수와의 다중상관분석에서는 기온, 습도, 강수량이 역위빈도에 유의한 영향을 미치는 것으로 나타났고 역위 중 In(2L)t가 상기한 환경변수 모두에 대하여 유의한 상관관계를 보인 반면, In(3R)C와 In(3R)P는 어느 것과도 상관성을 보이지 않았다. 염색체내 그리고 염색체간의 연관 또는 조합의 검정결과 연관불평형혈상을 1월, 5월, 그리고 7월 표본의 제3염색체에서, 그리고 비균일조합은 1월과 7월 표본에서 역시 제3염색체에서만 산출 되었다. Seasonal changes of inversion frequencies in Chonju 0. melanogaster populations were studied. A total of 1071 males were collected six times with ho months intewal from January through November in 1983. to analyse diploid sets of chromosomes carried by males, each male was mated to several virgin females homoBvgous for cytologically standard sequence in all chromo-somes. From each mating, more than seven FL larvae were selected in random and tested to find chromosomal aberrations. In the present study, 15 different inversions were found and identified to be paracentric only In both second and third chromosomes; seven were cosmopolitan and the rest eight endemic types. The average frequency of inversions was 0.465 and the mean number of inversions carried by a single male was 0.639. The linkage disequilibria were detected between the leK and right arms of third chromosomes from the samples of January, May and Julv, Whereas nonrandom associations appeared also in the third chromosomes only in January and Julv samples. In multiple regression analysis among frequencies of inversions and environ-mental variables it appeared that mean temperature, relative humidity and total precipitation for a month skipped over 30 days before collected affect to change to frequencies of particular inver-sions. With respect to the behavior of inversions in the present samples, it is suggested, with the Friedman's analysis of variance by ranks of inversion frequency orders, that the frequencies of inversions change cyclically year to year.

  • PDF

Interactions in a homogeneous isotropic modified couple stress thermoelastic solid with multi-dual-phase-lag heat transfer and two temperature

  • Lata, Parveen;Kaur, Harpreet
    • Steel and Composite Structures
    • /
    • 제38권2호
    • /
    • pp.213-221
    • /
    • 2021
  • The objective of this paper is to study the deformation in a homogeneous isotropic thermoelastic solid using modified couple stress theory subjected to ramp-type thermal source with two temperature. The advantage of this theory is the involvement of only one material length scale parameter which can determine the size effects. Laplace and Fourier transform technique is applied to obtain the solutions of the governing equations. The components of displacement, conductive temperature, stress components and couple stress are obtained in the transformed domain. A numerical inversion technique has been used to obtain the solutions in the physical domain. The effect of two temperature is depicted graphically on the resulted quantities. Numerical results show that the proposed model can capture the size effects of microstructures.

Effect of two-temperature in an orthotropic thermoelastic media with fractional order heat transfer

  • Lata, Parveen;Himanshi, Himanshi
    • Composite Materials and Engineering
    • /
    • 제3권3호
    • /
    • pp.241-262
    • /
    • 2021
  • In this article, we studied the effect of two-temperature in a two-dimensional orthotropic thermoelastic media with fractional order heat transfer in generalized thermoelasticity with three-phase-lags due to thermomechanical sources. The boundary of the surface is subjected to linearly distributed and concentrated loads (mechanical and thermal source). The solution of the problem is obtained with the help of Laplace and Fourier transform techniques. The expressions for displacement components, stress components and conductive temperature are derived in transformed domain. Numerical inversion technique is used to obtain the results in physical domain. The effect of two-temperature on all the physical quantities has been depicted with the help graphs. Some special cases are also discussed in the present investigation.

Time harmonic interactions due to inclined load in an orthotropic thermoelastic rotating media with fractional order heat transfer and two-temperature

  • Lata, Parveen;Himanshi, Himanshi
    • Coupled systems mechanics
    • /
    • 제11권4호
    • /
    • pp.297-313
    • /
    • 2022
  • The objective of this paper is to study the effect of frequency in a two-dimensional orthotropic thermoelastic rotating solid with fractional order heat transfer in generalized thermoelasticity with two-temperature due to inclined load. As an application the bounding surface is subjected to uniformly and linearly distributed loads (mechanical and thermal source). The problem is solved with the help of Fourier transform. Assuming the disturbances to be harmonically time dependent, the expressions for displacement components, stress components, conductive temperature and temperature change are derived in frequency domain. Numerical inversion technique has been used to determine the results in physical domain. The results are depicted graphically to show the effect of frequency on various components. Some particular cases are also discussed in the present research.

O/W 나노에멀젼 분산안정성에 미치는 보관온도의 영향 (Effect of Storage Temperature on the Dispersion Stability of O/W Nano-emulsions)

  • 이예은;유인상
    • KSBB Journal
    • /
    • 제29권5호
    • /
    • pp.385-391
    • /
    • 2014
  • In this study, the emulsion dispersion stability of optimizing storage temperature was investigated. The system was based on oil/water (O/W) emulsions. In order to evaluate the stability, mean diameter of droplet was measured as a function of temperature with various mixed hydrophilic lipophilic balance (HLB). In addition, the correlations between phase inversion temperature (PIT) and the optimum storage temperature were probed. In this system, majority of the smallest droplet was shown at temperature of $20^{\circ}C$ below PIT. Whether the temperature was increased or decreased from the optimum, size of the droplet increased. According to the mixed HLB, the particle size and optimum storage temperature were also affected. As the concentrations of surfactant were increased, the size of particle decreased with lower optimum temperature for storage. If the surfactant (4 wt%) were mixed with HLB, the optimum storage temperature was $21^{\circ}C$ for maintaining the size of smallest droplet at 108.3 nm in diameter. At above optimum condition, increased size of particle was observed approximately 4 % increases from 108.2 nm to 112.3 nm after 600 hours. The size of particle in emulsion was maintained stably without any considerable effect of Ostwald ripening phenomena at the optimum storage temperature with low polydispersity index.

SOI-MOSFET의 고온 동작에 관한 연구 (A Study on High Temperature Operation of SOI-MOSFET)

  • 최창용;문경숙;구상모
    • 한국전기전자재료학회논문지
    • /
    • 제21권8호
    • /
    • pp.706-710
    • /
    • 2008
  • The substrate bias effect on the current level of SOI-MOSFETs for high temperature operation has been investigated. In this work, we demonstrate the current level of SOI-MOSFETs can be controlled at different temperatures by applying a control bias to the substrate, showing that all current levels below T=150$^{\circ}C$ can be adjusted to a constant current level. 2D numerical simulation results show that substrate bias effectively controls the current conduction; as the substrate bias effectively lower the potential of the channel, inversion carrier generation is effectively controlled and consequently a constant current conduction level is achieved up to T=150$^{\circ}C$. We also demonstrate that the device simulated in this work has same operation at any temperature below T=150$^{\circ}C$ through mixed mode simulation.