• 제목/요약/키워드: Temperature front

검색결과 677건 처리시간 0.023초

장마의 재조명 (A New Look at Changma)

  • 서경환;손준혁;이준이
    • 대기
    • /
    • 제21권1호
    • /
    • pp.109-121
    • /
    • 2011
  • This study revisits the definition of Changma, which is the major rainy season in Korea and corresponds to a regional component of the East Asian summer monsoon system. In spite of several decades of researches on Changma, questions still remain on many aspects of Changma that include its proper definition, determination of its onset and retreat, and relevant large-scale dynamical and thermodynamical features. Therefore, this study clarifies the definition of Changma (which is a starting point for the study of interannual and interdecadal variability) using a basic concept of air mass and front by calculating equivalent potential temperature (${\theta}_e$) that considers air temperature and humidity simultaneously. A negative peak in the meridional gradient of this quantity signifies the approximate location of Changma front. This front has previously been recognized as the boundary between the tropical North Pacific air mass and cold Okhotsk sea air mass. However, this study identifies three more important air masses affecting Changma: the tropical monsoon air mass related to the intertropical convergence zone over Southeast Asia and South China Sea, the tropical continental air mass over North China, and intermittently polar continental air mass. The variations of these five air masses lead to complicated evolution of Changma and modulate intensity, onset and withdrawal dates, and duration of Changma on the interannual time scale. Importantly, use of ${\theta}_e$, 500-hPa geopotential height and 200 hPa zonal wind fields for determining Changma onset and withdrawal dates results in a significant increase (up to~57%) in the hindcast skill compared to a previous study.

고온 강판의 분무냉각에 있어서 MHF 점에 관한 연구 (Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.175-180
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about $900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the experimental results show that the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

차량 엔진룸에서의 냉각효율 향상에 관한 해석 (ANALYSIS OF THE ENHANCEMENT OF COOLING EFFICIENCY OF A VEHICLE IN THE ENGINE ROOM)

  • 이동렬
    • 한국전산유체공학회지
    • /
    • 제10권3호
    • /
    • pp.55-62
    • /
    • 2005
  • Flow and temperature fields of a mid-size vehicle engine room are examined numerically to analyze the enhancement of cooling efficiency of several different design cases in a front body shape. The wall temperatures of a radiator and an engine parte are utilized to predict the effects of engine cooling on the thermal environment and the cooling efficiency in an engine room. The analyzed results are the mass flow rate at the upper and lower inlets, in the radiator, and the condenser. It is shown that the shape of the front end, lay-out of the engine parts, and the presence of the undercover greatly influence the flow and temperature fields, and the enhancement of cooling efficiency in the engine room.

셀 입구 예열방법에 따른 고체산화물 연료전지/가스터빈 하이브리드 시스템의 성능해석 (Performance Analysis of Solid Oxide Fuel Cell/Gas Turbine Hybrid Systems for Different Cell Inlet Preheating Methods)

  • 양원준;김동섭;김재환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1664-1669
    • /
    • 2004
  • Design analysis of the solid oxide fuel cell and gas turbine combined power system is performed considering different methods for preheating cell inlet air. The purpose of air preheating is to keep the temperature difference between cell inlet and outlet within a practical design range. Three different methods are considered such as a burner in front of the cell, a preheater in front of the cell and recirculation of the cathode exit gas. Analyses are carried out for two maximum cell temperature differences. The greater temperature difference ensures higher efficiency. The cathode exit gas recirculation exhibits better performance than other methods.

  • PDF

Seasonal Variations in Distribution, Population Structure and Prosome Length of Calanus sinicus (Copepoda: Calanoida) in the Southern Waters of Korea

  • Kang, Young-Shil;Hong, Sung-Yun
    • Journal of the korean society of oceanography
    • /
    • 제33권1-2호
    • /
    • pp.28-34
    • /
    • 1998
  • Variations in abundance, size and population structure of Calanus sinicus were studied in the southern waters of Korea in connection with hydrographic conditions during 1991-1992. Abundance was high in April and low in August. This species was concentrated inshore of a coastal temperature front, or around the temperature front in April. The 1st-3rd copepodites dominated in February and April, and adults in August. The mean population stages in February and April were younger than those in other survey months. This suggests that this species mainly reproduced during winter-early spring. In prosome length, the 1st-4th copepodites were larger in April than in other survey months, and the 5th copepodite and adult were the largest in February. Mean prosome length of C. sinicus showed weak inverse relationship with sea water temperature, but it was not statistically evidenced.

  • PDF

고온 평판의 분무냉각에 있어서 MHF점에 관한 연구 (Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate)

  • 김영찬
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.974-981
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about$ 900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

유선형 스텝에 의해 안정화된 예혼합화염의 구조와 연소특성에 관한 연구 ($\Pi$) (A Study on the Flame Structure and Combustion Charactexistics of a Premixed Flame Stabilized by a Streamline Step( $\Pi$))

  • 이재득;최병륜
    • 대한기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.1661-1668
    • /
    • 1990
  • 본 연구에서는 코히런트 와(渦)에 지배되는 난류 예혼합화염의 미세구조를 밝 히기 위해 슐리이렌사진과 온도, 이온전류의 3가지를 동시에 측정하고, 그 변동량을 통계처리, 분석하여, 미시적인 화염구조 모델을 제시하고자 한다.

Solenoid 전동기의 냉각을 위한 수치해석적 연구 (Numerical Analysis of Heat Transfer Characteristics inside a Solenoid Motor System)

  • 정민채;윤상길;윤동진;서정세
    • 한국기계가공학회지
    • /
    • 제19권4호
    • /
    • pp.99-104
    • /
    • 2020
  • In this study, the temperature distribution and heat transfer characteristics of each component in a solenoid motor system were numerically investigated when heat is generated by the steel pad attached to the solenoid ring of the motor. It was found that the internal airflow was complicated by the inflow velocity of air and the rotation of guide rollers and solenoid rings. Based on the numerical results, the tendency for temperature changes in the steel panel was lower due to the contact of the cooling air in the front in the rotational direction, and the peak temperature was at the front of the center. In particular, it was confirmed that as the air inflow rate was increased, the temperature was reduced due to strong convection. The temperature of the iron plate pad was decreased as the convective heat transfer coefficient was linearly increased with increasing airflow around the solenoid ring. In addition, the temperature of the iron plate panel was rapidly increased with increasing heat generation.

상변화 물질을 사용한 축열조에서의 열전달 - 수직원관에서의 내향용융 실험 - (Heat Transfer in Heat Storage System with P.C.M. - Inward Melting in a Vertical Tube)

  • 손화승;황태인;이채문;최국광;임장순
    • 태양에너지
    • /
    • 제9권1호
    • /
    • pp.53-61
    • /
    • 1989
  • In the present investigation, experiments on the melting of a phase change material were performed to research heat transfer phenomena generated by means of conduction and natural convection in the vertical tube at inward melting. The phase change material used in the experiments is 99 percent pure n-Docosane paraffin which is measured melting temperature of $42.5^{\circ}C$, latent heat of 37.5 cal/g, heat conductivity of $0.1505W/m^{\circ}C$. Experiments were performed both in the no-subcooling which is initiating it at melting temperature of phase change material, and in the subcooling which means to initiate it under melting temperature of phase change material, in order to compare and investigate the horizontal temperature history, vertical temperature history, ratio of melting and melted mass, figure of the melting front in the vertical tube. In the experimental results, heat transfer from tube wall to phase change material were due to conduction at early stage and due to natural convection with the passage of time, and then occurred melting downward from surface by volumetric expansion. Natural convection affects temperature distribution in the tube, ratio of melting and melted mass, figure of the melting front and then progress rapidly in case of nosubcooling compared to subcooling.

  • PDF

MAGMAsoft를 이용한 Aircon Compressor Front Housing의 다이캐스팅 주조공정설계 (Die Casting Process Design for Front Housing of Aircon Compressor by Using MAGMAsoft)

  • 공성락;박진영;김억수;문영훈
    • 소성∙가공
    • /
    • 제9권4호
    • /
    • pp.413-420
    • /
    • 2000
  • In the die casting process, the flow of liquid metal has significant influence on the quality of casting products and die life. For the optimal process design of front housing part of aircon compressor, various analyses were performed in this study by using computer simulation code, MAGMAsoft. The simulation has been focused on the molten metal behaviors during the filling and solidification stages for the sound casting products. Two cases of casting design that have different types of gating system are considered in the analysis. The potential sites where the casting defects may occur is examined by computer simulation and an improved design process is proposed. Also the effect of partial squeeze on the quality of casting products is considered and the optimal time lag after filling process is determined. For the die-stability, the effect of operational parameters such as die temperature, heat cycle and spot cooling on the die life has also been analyzed.

  • PDF