• Title/Summary/Keyword: Temperature feedback

Search Result 295, Processing Time 0.026 seconds

Stability analysis in a two-path Temperature coefficient feedback reactor (2로 온도계수 궤환로에서의 안정성 해석)

  • Eun Rae Roh
    • 전기의세계
    • /
    • v.16 no.2
    • /
    • pp.17-21
    • /
    • 1967
  • In reactor operation, it is widely known that the absolute stability may not exist for multiple feedback paths even though the single lumped negative temperature coefficient feedback case is clearly stable at all frequencies above those creating xenon poisoning effects. However, interesting and useful stability information may be obtained from a two-path temperature coefficient feedback which can be represented in a water-cooled, water-moderated hetergeneous reactor. In this paper, the outline of an operating stability of a reactor having two-path temperature coefficient feedback is analyzed and described neglecting poison effects.

  • PDF

Memoryless Feedback Temperature Control of an Extruder by the Switching Actuating Value

  • Lee, Man-Hyung;Hong, Suh-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.100.2-100
    • /
    • 2001
  • In this paper, we presented a switching-based control algorithm for improving the speed of response on temperature control of an extruder. We proposed a switching actuating value method in a temperature control of extruder and showed the effect of H$\infty$ control and PID control. Recently, the memoryless feedback control had proposed, which was not only the real time integration element, but also the memory elements. We examined the application of a switching actuating value method to a memoryless feedback, in a unit barrel temperature control of an extruder.

  • PDF

Uncertainty quantification of the power control system of a small PWR with coolant temperature perturbation

  • Li, Xiaoyu;Li, Chuhao;Hu, Yang;Yu, Yongqi;Zeng, Wenjie;Wu, Haibiao
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2048-2054
    • /
    • 2022
  • The coolant temperature feedback coefficient is an important parameter of reactor core power control system. To study the coolant temperature feedback coefficient influence on the core power control system of small PWR, the core power control system is built with the nonlinear model and fuzzy control theory. Then, the uncertainty quantification method of reactor core parameters is established based on the Latin hypercube sampling method and the Bootstrap method. Finally, under the conditions of reactivity step perturbation and coolant inlet temperature step perturbation, uncertainty analysis for two cases is carried out. The result shows that with fuzzy controller and fuzzy PID controller, the uncertainty of the coolant temperature feedback coefficient affects the core power control system, and the maximum uncertainties of core relative power, coolant temperature deviation, fuel temperature deviation and total reactivity are acceptable.

Stability Analysis of an Accelerator-Driven Fluid-Fueled Subcritical Reactor System

  • Kim, Do-Sam;Cho, Nam-Zin
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.90-95
    • /
    • 1997
  • In this work, linear dynamics of a circulating fluid-fueled subcritical reactor system with temperature feedback and external neutron source was modeled and examined. In a circulating fluid-fuel system, the stable region is slightly moved by a circulation fluid effect. The effects of subcriticality and temperature feedback coefficient on the reactor stability were tested by calculating frequency response of neutron density originated from reactivity perturbation or external source oscillation of system. The amplitude transfer function has a different shape near subcritical region due to the exponential term in the transfer function. The results of the study show that at a slightly subcritical region, low frequency oscillation in accelerator current or reactivity can be amplified depending on the temperature feedback. However, as the subcriticality increases, the oscillation becomes negligible regardless of the magnitude of the temperature feedback coefficient.

  • PDF

A Study on the Control of Water Flow and Water Temperature in the Radiant Cooling System through Simulations (시뮬레이션을 통한 바닥복사냉방 시스템의 공급유량 및 냉수온도 제어에 관한 연구)

  • 김용이;윤혜림;여명석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.532-540
    • /
    • 2001
  • The objectives of this study are to analyze the control variables according to condensation occurrence, to find the range in floor surface temperature and frequency of condensation, and to evaluate the control methods through simulations when the radiant heating system is used for cooling. Through the simulation analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The results show that the lowest floor surface temperature is around $23^{\circ}C$, the surface condensation can be prevented by controlling indoor humidity within 20g/kg(DA0, and that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF

An Experimental Study on Control Performance of Radiant Floor Cooling Using Ondol (온돌을 이용한 바닥복사냉방의 제어성능에 관한 실험적 연구)

  • 김용이;임재한;한여명;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1165-1173
    • /
    • 2001
  • The objectives of this study are to analyze the application of radiant floor cooling and to evaluate the control methods through experiments when the radiant heating system is used for cooling. Through the experiment analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The cooling curve (reset ratio) is found for radiant cooling, which shows tole relation between outside air temperature and supply water temperature. Comparison of cooling methods shows that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF

Electro-thermal Feedback Effects on the Signal in a Pulse Voltage Biased μ-bolometer Focal Plane Array (마이크로 볼로미터 초점면 배열에서 전기-열적 피드백 현상이 신호에 미치는 영향)

  • Park, Seung-Man;Han, Seungoh
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1886-1891
    • /
    • 2012
  • In this paper, the analytical models for the electrothermal feedback of a ${\mu}$-bolometer focal plane array(FPA) are proposed and applied to the conceptually designed FPA to investigate the electrothermal feedback effect on bolometer FPA signal. The temperature and resistance change of the ${\mu}$-bolometer by the electrothermal feedback(ETF) model are increased upto 20 and 35.7 % of those of no feedback case, respectively, while those by the effective thermal conductance(ETC) model increased 8.5 and 15.1 %. The integration current and output voltage of a CTIA used as an column amplifier of FPA are also increased upto 41.6 and 32.4 % by the ETF model, while increased upto 17.2 and 13.5 % by the ETC model. The proposed models give more accurate temperature change, accordingly larger signal than no feedback considering case. Electrothermal feedback effect should be considered to design a high performance and high density ${\mu}$-bolometer FPA. The proposed models are very useful to investigate the transient thermal analysis, also considered to be useful to predict the responsivity and dynamic range of ${\mu}$-bolometer FPAs.

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

Design and Fabrication of a Conductively Cooled Cryostat by Cryocooler (냉동기 부착형 전도냉각식 Cryostat의 설계 및 제작)

  • Bae, Joon-Han;Sim, Ki-Deck
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1921-1924
    • /
    • 2007
  • In order to measure the superconducting transition temperature, the critical current and the alternating current(AC) loss on short samples of high temperature superconductor, a cryocooler cooled cryostat has been designed and built. Two closed-cycle coolers provide cooling with an ultimate sample temperature below 16K. Temperature regulation is provided by 50W of electrical heater that opposes the cooling power from the cold heads. Temperature control feedback is by means of a cernox temperature sensor co-located with the heaters on the second stage of the cold head. Additional temperature sensors are located on the sample mount(B1), on the CVI cold head(B2) and on the Dakin cold head(B3). AC losses on the sample high temperature superconductor were measured at 30K so that the developed device performance was evaluated. In this paper, the design, fabrication and test results on the cryocooler cooled cryostat are presented.

A Study on the Application of Temperature Feedback Aeration Method for Composting of Municipal Solid Wastes (효율적 퇴비화를 위한 온도제어 공기공급방식의 적용에 관한 연구)

  • Kim, Byung-Tae;Kim, Jung-Wk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.2 no.1
    • /
    • pp.3-18
    • /
    • 1994
  • Municipal solid wastes in Korea have physical and chemical properties suitable for composting, but composting has had little practical use in solid waste disposal until now because of a lack of understanding of process control. For practical use of composting, process control must be capable of maintaining good product quality while large quantities are composted in a short period of time. Ventilation control to maintain optimum temperature(Temperature Feedback Aeration Method) is reported to be convenient to operate. The purpose of this study is to analyze process efficiency and optimum temperature in the temperature feedback aeration method for composting of municipal solid wastes. The results of this study show that degradation and drying of substrate in the temperature feedback aeration method are higher than those in the constant aeration method. And the optimum temperature range for composting of solid wastes appears to be $50{\sim}54^{\circ}C$.

  • PDF