• Title/Summary/Keyword: Temperature efficiency

Search Result 5,860, Processing Time 0.035 seconds

A Study on the Characteristics of Total Heat Exchanger under Various Conditions (운전조건에 따른 전열교환기의 성능특성 연구)

  • Bail Cheol-Ho;Lim Young-Heon;Gulnora Diuraeva;Park Ji-Yeol;Kwak Kyung-Min;Chu Euy-Sung;Kim Young-Saeng;Kim Jee-Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.10
    • /
    • pp.891-897
    • /
    • 2005
  • The characteristics of energy Performance for total heat exchanger have been investigated under various conditions. In cooling operation the latent and enthalpy efficiency are affected by the difference of absolute humidity ratio between indoor and outdoor air. In addition to this the characteristics of absorbing material in the element affects the energy performance. Low dry bulb temperature of indoor air or high absolute humidity ratio in outdoor air give high latent and enthalpy efficiency even with the same temperature difference of dry bulb temperate between indoor and outdoor air.

A Study on Exhaust Gas Characteristics of Heavy-duty Diesel Engines through Actual Vehicle Application of Non-influenced Temperature Condition Type Active Regeneration Method (온도조건 비영향형 복합재생방식 DPF의 실차적용을 통한 대형디젤기관의 배출가스 특성 연구)

  • Yun chul Lee;Sang ki Oh
    • Journal of ILASS-Korea
    • /
    • v.29 no.2
    • /
    • pp.53-59
    • /
    • 2024
  • Cars are one of the main causes of air pollution in large cities, and 34.6% of domestic air pollution emissions come from mobile sources, of which cars account for 69.6%. In particular, the importance of nitrogen oxides (NOx) and particulate matter (PM), which are major pollutants in diesel vehicles, is increasing due to their high contribution to emissions. Therefore, in this study, the problem of natural regeneration caused by low exhaust gas temperature during low speed and low load operation was solved by applying a complex regeneration DPF that is not affected by temperature conditions to large diesel vehicles with higher driving time and engine displacement than small and medium-sized vehicles. And the feasibility of application to large diesel vehicles was reviewed by measuring the emission reduction efficiency. As a result of the reduction efficiency test on the actual vehicle durability product, PM showed a reduction efficiency of 84% to 86%, and the reduction efficiency of gaseous substances showed a high reduction efficiency of over 90%. The actual vehicle applicability test was completed with three driving patterns: village bus vehicle, police car, and road-going construction equipment vehicle, and no device problems occurred until the end of the test. Both load and no-load smoke measurement results showed a smoke reduction efficiency of over 96%.

GaAs solar cells for a satellite application (위성체의 동력원으로서의 GaAs 태양전지)

  • 이승기;한민구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.620-626
    • /
    • 1988
  • GaAs solar cells may be the most attractive and efficient power source of a satellite. GaAs is more radiation tolerant and less temperature sensitive than widely used silicon. $Al_{x}$ Ga$_{1-x}$ As/GaAs solar cells have been designed and fabricated by Liquid Phase Epitaxial method. GaAs solar cells, of which structure is about 0.2 .mu.m p$^{+}$ - window layer, 0.6-1.O .mu.m Ge-doped p-layer. 3.mu.m n-GaAs layer and n$^{+}$ - buffer layer, have been characterized as a function of operating temperature from 25 .deg.C to 130 .deg.C. Open circuit voltage decreases linearly with increasing temperature by 1.4-1.51 mV/ .deg.C while degradation of silicon solar cells is about 2.2-2.5 mV/ .deg.C, short circuit current does not increase much with increasing temperature. Relative efficiency decreases with increasing of temperature by about 0.21-0.29 %/ .deg.C. Efficiency degradation of silicon solar cells with temperature is known to be about 0.5%/ .deg.C and our results show GaAs solar cells may be an excellent candidate for concentrated solar cells.ells.

  • PDF

Neutral Beam assisted Chemical Vapor Deposition at Low Temperature for n-type Doped nano-crystalline silicon Thin Film

  • Jang, Jin-Nyeong;Lee, Dong-Hyeok;So, Hyeon-Uk;Yu, Seok-Jae;Lee, Bong-Ju;Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.52-52
    • /
    • 2011
  • A novel deposition process for n-type nanocrystalline silicon (n-type nc-Si) thin films at room temperature has been developed by adopting the neutral beam assisted chemical vapor deposition (NBa-CVD). During formation of n-type nc-Si thin film by the NBa-CVD process with silicon reflector electrode at room temperature, the energetic particles could induce enhance doping efficiency and crystalline phase in polymorphous-Si thin films without additional heating on substrate; The dark conductivity and substrate temperature of P-doped polymorphous~nano crystalline silicon thin films increased with increasing the reflector bias. The NB energy heating substrate(but lower than $80^{\circ}C$ and increase doping efficiency. This low temperature processed doped nano-crystalline can address key problem in applications from flexible display backplane thin film transistor to flexible solar cell.

  • PDF

Thermal Performance of Solar Thermal System by On-Off Differential Temperature of Differential Temperature Controller (차온제어기의 On-Off 온도설정에 따른 태양열 시스템 열성능)

  • Shin, U-Cheul;Baek, Nam-Choon
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.1-8
    • /
    • 2005
  • On-off differential controller is one of the very important components which affect the system performance of the active solar thermal system. In this study, analyses were made regarding the influence of "on-off" setting temperature on the system efficiency and on the electrical consumption by circulation pump. This study was performed by experiment as well as the computer simulation using TRNSYS program. The simulation system was developed in this study was verified the its reliability by the experimental results. As a results, the turn off temperature(${\Delta}T_{off}$) is much more influence than the turn on temperature(${\Delta}T_{on}$) on the system efficiency. It is more clear and sensitivity in winter season. Finally the optimum on-off setting value and the system on-off pattern according to the several different kind of system was also represented.

The Optimal Design of Single Sided PMLSM for Considering Winding Temperature Rising according to Thickness of Teeth

  • An, Ho-Jin;Cho, Gyu-Won;Woo, Seok-Hyeon;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.339-344
    • /
    • 2013
  • This research deals with design of the maximum thrust density with considering winding temperature rise of single-sided PMLSM. The temperature rise of winding which caused to machine characteristics such as copper loss, iron loss and efficiency was analyzed by FEM. The maximum allowable current density was calculated within the allowable temperature. The effects of loss and efficiency according to temperature characteristic were confirmed.

Biological Waste Water Treatment with Solar Thermal Energy (저온 태양열 이용 생물학적 오수 처리)

  • Chung, Mo;Lee, Dong-Won;Kim, Jeong-Bae;Yoon, Eung-Sang;Byun, Moo-Ryong;Byun, Moon-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.559-562
    • /
    • 2006
  • A low-temperature solar thermal system assisting a biological nitrogen treatment reservoir was designed and field-tested. A large tank whose temperature was maintained at about $25{\sim}30^{\circ}C$ to enhance the performance of a biological nitrogen treatment process was heated by an array of flat plate solar collectors. Test results revealed that the overall collector efficiency was above 50% for the most cases tested. This high efficiency was possible owing to the relatively low collector temperature that can be traced back to the reservoir temperature. A substantial enhancement in nitrogen treatment was observed as a result of maintaining the reservoir temperature higher.

  • PDF

Operating Temperature Characteristics of Amorphous Silicon Solar Cells (비정질(非晶質) 실리콘 태양전지(太陽電池)의 동작온도(動作溫度) 특성(特性))

  • Han, Min-Koo
    • Solar Energy
    • /
    • v.7 no.1
    • /
    • pp.30-34
    • /
    • 1987
  • Experimental results are discussed concerning temperature effects from $25^{\circ}C$ to $100^{\circ}C$ on amorphous silicon solar cells. N-I-P hydrogenated amorphous silicon solar cells are fabricated on stainless steel and indium tin oxide glass substrates. The open circuit voltage, short circuit current, fill factor and conversion efficiency have been measured under AM1 condition as a function of temperature. The open circuit voltage decreased by $2.6mV/^{\circ}C$ while the short circuit current increases with increased temperature. The conversion efficiency is almost independent of temperature which is contrary to widely using single crystalline solar cells of which efficiencies decrease with increasing temperature.

  • PDF

Evaluation of Washing Efficiency based on Consumer's Washing Behavior Integral Approach for Improving Washing Machines (II)- (소비자의 세탁습관에 따른 세탁효율 평가 -국산세탁기의 경쟁력 강화를 위한 세탁 실태조사 및 실험연구(II)-)

  • 오경화;유혜경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.2
    • /
    • pp.251-261
    • /
    • 1997
  • According to consumer's washing behavior, the washing efficiency of three different types of washing machines-pulsator, agitator, and drum was studied. Their detergency, rinsing efficiency, and the degree of fabric damage, tangle, and wrinkle were evaluated. The results showed that efficient washing capacity was different from the specified capacity of washing machine. Detergency and rinsing efficiency frere apparently decreased when more than 50% of capacity was loaded in washing machine of pulsator type, and 80% for agitator or drum types. They were also affected by detergent adding methods, and decreased in the order of water-detergent-washing load> washing load-detergent-water> washing load-water-detergent. Rinsing efficiency was significantly improved when the rinsing temperature was set above washing temperature. In addition, it was revealed that detergency, fabric damage, wrinkle, and tangle were highly correlated. The relationships between detergency and tangle were different for different types of washing machine. Positive relationships were found for agitator and drum types, whereas negative for pulsator type.

  • PDF

VERIFICATION OF FIN EFFICIENCY THEORY FOR THE CIRCULAR FINNED-TUBE HEAT EXCHANGER BY NUMERICAL EXPERIMENT (원형휜-원형관 열교환기의 휜효율 이론에 관한 수치적 검증)

  • Kang, H.C.;Lim, B.B.;Lee, J.W.;Chang, B.C.;Ahn, S.W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.137-142
    • /
    • 2008
  • The purpose of the present study is to investigate the convective heat transfer characteristics and the validity of fin efficiency of the circular finned-tube heat exchanger by using commercial CFD code. The heat transfer coefficient obtained by using the laminar model was 22% overestimated to the experimental data. The fin surface temperature compared with the experimental data measured by the liquid crystal method. The fin efficiency by the present numerical experiment, defined as normalized and averaged fin surface temperature, was greater than the theoretical fin efficiency and the difference is increased at high value of the factor m.

  • PDF