• Title/Summary/Keyword: Temperature dependency

Search Result 388, Processing Time 0.03 seconds

The thermal & hydraulic analysis of the cooling passage for HTS power cable (초전도케이블 냉각유로의 열 및 유동 특성 해석)

  • 홍용주;염한길;김효봉;고득용
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.167-170
    • /
    • 2003
  • The thermal and hydraulic characteristics of the cooling passage for HTS power cable should be carefully investigated to get the highly reliable and economic operation. In this study, the pressure drop and temperature change of the coolant flowing the corrugated passage was estimated using the simple one-dimensional approach, and the temperature distribution in the radial direction was calculated. The results show the dependency of the mass flow rate, thermal conductivities on the cooling performance of the HTS cable.

  • PDF

Magnetic Properties of FeCoSiB Amorphous Films Annealed in Magnetic field (자계중 열처리된 FeCoSiB 아몰퍼스박막의 자기적 특성)

  • 신광호;김영학;사공건
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1305-1309
    • /
    • 2003
  • To utilize FeCoSiB amorphous films for magnetoelastic sensors, the temperature dependency of magnetization (M-T curve) and the magnetization properties of the amorphous films were investigated in this study. As the amount of cobalt In the films increased, the Curie temperature decreased but the crystallization temperature increased. In addition to this, the crystallization temperature was lower than the Curie temperature in the film containing 20 at% cobalt. The optimized annealing condition was set up by analyzing the H-T curve. And then, the amorphous film that has excellent magnetic properties and uni-axal anisotropy could be prepared for construction of the magnetoelastic sensor devices. The coercive force of the film was below 0.5 Oe and the anisotripic field was about 5 Oe.

CO Two-photon Laser Induced Fluorescence Measurements in High Temperature and Pressure Conditions (고온고압 조건에서 Two-Photon LIF를 이용한 CO 측정에 관한 연구)

  • Oh, Seung-Mook;Kim, Duk-Sang;Miles, Paul C.;Colban, Will F.
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Carbon monoxide (CO) is not only an important intermediate species in chemical reaction mechanisms of hydrocarbon fuel combustion, but also a crucial pollutant species emitted from automotive engines. To better understand the physical processes impacting CO emissions, the development of laser-based measurement techniques that can visualize in-cylinder CO distributions is desirable. Among these techniques, Laser-Induced Fluorescence (LIF) is a sensitive and species-selective detection technique capable of good spatial resolution. However, some technical matters such as deep UV excitation, severe pressure dependency of the LIF signal, and potential interference from other species have been major challenges for CO LIF application. This study is focused on investigating the feasibility of CO two-photon LIF in a direct-injection diesel engine operating at typical pressure and temperature conditions with commercial grade diesel fuel. Spectroscopic analysis shows that the CO fluorescence signal can be separated from $C_2$ Swan band or broadband fluorescence from PAHs when the signal is collected near 483 nm. The signal-to-noise ratio of CO LIF deteriorate rapidly as pressure is increased, following $P^{-1.49}$ which matches the theoretical signal pressure dependency.

  • PDF

NEAL-WALL GRID DEPENDENCY OF CFD SIMULATION FOR A SUBCOOLED BOILING FLOW (과냉 비등유동에 대한 CFD 모의 계산에서의 벽 인접격자 영향)

  • In, W.K.;Shin, C.H.;Chun, T.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.320-325
    • /
    • 2010
  • A multiphase CFD analysis is performed to investigate the effect of near-wall grid for simulating a subcooled boiling flow in vertical tube. The multiphase flow model used in this CFD analysis is the two-fluid model in which liquid(water) and vapor(steam) are considered as continuous and dispersed fluids, respectively. A wall boiling model is also used to simulate the subcooled boiling heat transfer at the heated wall boundary. The diameter and heated length of tube are 0.0154 m and 2 m, respectively. The system pressure in tube is 4.5 MPa and the inlet subcooling is 60 K. The near-wall grid size in the non-dimensional wall unit ($y_{w}^{+}$) was examined from 64 to 172 at the outlet boundary. The CFD calculations predicted the void distributions as well as the liquid and wall temperatures in tube. The predicted axial variations of the void fraction and the wall temperature are compared with the measured ones. The CFD prediction of the wall temperature is shown to slightly depend on the near-wall grid size but the axial void prediction has somewhat large dependency. The CFD prediction was found to show a better agreement with the measured one for the large near-wall grid, e.g., $y_{w}^{+}$ > 100.

  • PDF

NEAR-WALL GRID DEPENDENCY OF CFD SIMULATION FOR A SUBCOOLED BOILING FLOW USING WALL BOILING MODEL (벽 비등모델을 이용한 과냉비등 유동에 대한 CFD 모의계산에서 벽 인접격자의 영향)

  • In, W.K.;Shin, C.H.;Chun, T.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.3
    • /
    • pp.24-31
    • /
    • 2010
  • boiling flow in vertical tube. The multiphase flow model used in this CFD analysis is the two-fluid model in which liquid(water) and gas(vapour) are considered as continuous and dispersed fluids, respectively. A wall boiling model is also used to simulate the subcooled boiling heat transfer at the heated wall boundary. The diameter and heated length of tube are 0.0154 m and 2 m, respectively. The system pressure in tube is 4.5 MPa and the inlet subcooling is 60 K. The near-wall grid size in the non-dimensional wall unit for lqiuid phase ($y^+_{w,l}$) was examined from 101 to 313 at the outlet boundary. The CFD calculations predicted the void distributions as well as the liquid and wall temperatures in tube. The predicted axial variations of the void fraction and the wall temperature are compared with the measured ones. The CFD prediction of the wall temperature is shown to slightly depend on the near-wall grid size but the axial void prediction has somewhat large dependency. The CFD prediction was found to show a better agreement with the measured one for the large near-wall grid, e.g., $y^+_{w,l}$ > 300 at the tube exit.

Effects of temperature dependent material properties on mixed mode crack tip parameters of functionally graded materials

  • Rajabi, Mohammad;Soltani, Nasser;Eshraghi, Iman
    • Structural Engineering and Mechanics
    • /
    • v.58 no.2
    • /
    • pp.217-230
    • /
    • 2016
  • Effects of temperature dependent material properties on mixed mode fracture parameters of functionally graded materials subjected to thermal loading are investigated. A domain form of the $J_k$-integral method including temperature-dependent material properties and its numerical implementation using finite element analysis is presented. Temperature and displacement fields are calculated using finite element analysis and are used to compute mixed mode stress intensity factors using the $J_k$-integral. Numerical results indicate that temperature-dependency of material properties has considerable effect on the mixed-mode stress intensity factors of cracked functionally graded structures.

Autogenous Shrinkage of High Strength Mortar According to the Curing Temperature Variation (양생온도 변화에 따른 고강도 모르터의 자기수축 특성)

  • Song, Ri-Fan;Lee, Il-Sun;Baek, Dae-Hyun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.83-85
    • /
    • 2010
  • This study, by analyzing autogenous shrinkage of high-strength mortar according to changes of curing temperature, examined whether or not predictive autogenous shrinkage by an accumulated temperature method can be calculated. As a result, it could be known that dependency of autogenous shrinkage on temperature can be examined, but the autogenous shrinkage amount according to accumulated temperature was similar before and after the early $100 ^{\circ}D{\cdot}D$ and, after that, the difference in shrinkage amount by curing temperature was large.

  • PDF

Temperature-dependent Characteristics of Discharge in AC-PDP (교류형 PDP의 온도에 따른 방전특성)

  • Kim, Gun-Su;Lee, Seok-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.3
    • /
    • pp.239-247
    • /
    • 2009
  • In AC-PDP, it is necessary to achieve high luminance efficacy, high luminance and high resolution by adopting technologies such as high Xenon concentration, MgO doping, and long gap. However, it is very difficult to apply above technologies because they reduce driving voltage margin. For example, doping of MgO reduces driving voltage but introduces new problems such as increased temperature dependency of discharge, which result in larger variations in driving margin at different temperatures. In this paper, we present the experimental results of the characteristics of temperature-dependent discharges. In addition, we suggest the mechanism of bright noise, black noise, and high temperature mis-discharge, which depend on temperature-dependent characteristics of MgO.

Effects of Drying Conditions on the Quality of White Ginseng (백삼건조 조건이 품질에 미치는 영향)

  • 도재호;김상달
    • Journal of Ginseng Research
    • /
    • v.9 no.2
    • /
    • pp.248-255
    • /
    • 1985
  • In order to investigate the optimal drying condition of white ginseng by using bulk air drier(130 x 62 x 65cm), drying curves, diffusion coefficient at various drying temperature, the energy of activation, variation of color intensity and chemical components during drying of white ginseng were studied. Fick's second low of diffusion for diffusion out of spheres was successfully applied to describe the drying of white ginseng. It was found that the diffusion coefficient of water was 2.2x107, 9.0x107 cm2/sec at drying temperature 4$0^{\circ}C$, 55$^{\circ}C$, respectively. An Arrhenius type temperature dependency of moisture diffusivity was found, the energy of activation being 18.8 Kcal/g mol. Color intensity of white ginseng dried at various drying temperature was increased with an increase in drying temperature. The contents of crude protein, reducing sugar and crude saponin during drying of white ginseng were gradually decreased as increasing of drying time. And with the sensory evaluation by multiple comparison difference analysis, the optimal drying temperature of white ginseng was between 45$^{\circ}C$ and 5$0^{\circ}C$.

  • PDF

Thermal Conductivity Measurement of Insulation Material for Superconducting Application

  • Chol, Y.S.;Kim, D.L.;Shin, D.W.;Hwang, S.D.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.2
    • /
    • pp.29-32
    • /
    • 2011
  • The thermal properties of insulation material are essential to develop a high-temperature superconducting (HTS) power cable to be operated at around liquid nitrogen temperature. Unlike metallic materials, nonmetallic materials have a high thermal resistance; therefore special attention needs to be paid to estimate heat flow correctly. Thus, we have developed a precise instrument for measuring the thermal conductivity of insulating materials over a temperature range from 40 K to near room temperature using a cryocooler. Firstly, the measurement of thermal conductivity for Teflon is carried out for accuracy confirmation. For a supplied heat flux, the temperature difference between warm and cold side is measured in steady state, from which the thermal conductivity of Teflon is calculated and compared with published result of NIST. In addition, the apparent thermal conductivity of Polypropylene laminated paper (PPLP) is presented and its temperature dependency is discussed.