• Title/Summary/Keyword: Temperature characteristics analysis

Search Result 4,570, Processing Time 0.036 seconds

Thermal Characteristics Analysis of a High-Speed HMC Spindle System (초고속 HMC 주축계의 열특성 해석)

  • 김석일;김기상;김기태;나승표
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.441-446
    • /
    • 2001
  • This paper presents the thermal characteristics analysis of a high-speed HMC spindle system with angular contact ball bearings, built-in motor, oil-jet lubrication method, oil jacket cooling method, and so on. The spindle system is composed of the main spindle and sub-spindle which are mechanically connected by a flexible coupling. The spindles are supported by two front and rear bearings, and the built-in motor is located between the front and rear bearings of the sub-spindle. The thermal analysis model of spindle system is constructed by the finite element method, and the thermal characteristics in the design stage are estimated based on temperature distribution and heat flow under the various testing conditions related to material of bearing ball, spindle speed and coolant temperature.

  • PDF

3D electromagnetic design and electrical characteristics analysis of a 10-MW-class high-temperature superconducting synchronous generator for wind power

  • Kim, J.H.;Park, S.I.;Le, T.D.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.47-53
    • /
    • 2014
  • In this paper, the general electromagnetic design process of a 10-MW-class high-temperature superconducting (HTS) synchronous generator that is intended to be utilized for large scale offshore wind generator is discussed. This paper presents three-dimensional (3D) electromagnetic design proposal and electrical characteristic analysis results of a 10-MW-class HTS synchronous generator for wind power. For more detailed design by reducing the errors of a two-dimensional (2D) design owing to leakage flux in air-gap, we redesign and analyze the 2D conceptual electromagnetic design model of the HTS synchronous generator using 3D finite element analysis (FEA) software. Then electrical characteristics which include the no-load and full-load voltage of generator, harmonic contents of these two load conditions, voltage regulation and losses of generator are analyzed by commercial 3D FEA software.

Investigating Elementary Students에 Alternative Conceptions of Heat and Temperature (초등학생들의 열과 온도에 대한 대안개념 조사)

  • 최행숙;김은경;백성혜;이길재;정완호
    • Journal of Korean Elementary Science Education
    • /
    • v.20 no.1
    • /
    • pp.123-137
    • /
    • 2001
  • In this study, the contents of elementary school science textbooks related to 'heat and temperature' are analyzed and alternative conceptions ofi"heat and temperature" among students enrolled in grades 4, 5 and 6 are investigated. 259 students were selected from a elementary school located in urban area. The relationships between students' alternative conceptions and the content of elementary science textbooks are also examined. Students' conceptions are analyzed from their answers to a paper-and-pencil test. The typical alternative conception of "heat and temperature" held by students was follows. They think that "heat" is a material and "temperature" is value of heat amount. They can't distinguish between "heat" and "temperature". Their explanation of "heat and temperature" is focused on hot or cool sensation and other observable characteristics of a material. A textbook analysis indicated that contents on "heat and temperature" were organized without the viewpoint of particle motion theory. This may be one of the causes of students' alternative conceptions.

  • PDF

Beat Transfer Analysis of Concrete Members under High Temperature (고온조건에서 콘크리트 부재의 온도전이)

  • Lee, Tae-Gyu;Kim, Hye-Uk
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1536-1541
    • /
    • 2009
  • When water inside the concrete member evaporates by high temperature, the evaporation heat which absorbs surrounding temperature occurs. The rate of increment of the internal temperature in concrete is reduced due to the evaporation heat in spite of continuously increasing external temperature. In this paper, the prediction method of internal temperature of high strength concrete members considering the evaporation heat under the high temperature is presented. Finite element method is employed to facilitate thermal analysis for any position of member. And the thermal characteristics models of high strength concrete affected by high temperature are proposed. To demonstrate the validity of this numerical procedure, the prediction by the proposed algorithm is compared with the test results of other researchers. The proposed algorithm shows a good agreement with the experimental results including the phenomenon that temperature is lost by the evaporation heat.

  • PDF

Characteristics Analysis of 2-pin Sensor Composited Fuel Heater using the Low Temperature Fluidity (저온유동성시험기를 이용한 2-핀용 센서통합연료히터의 특성연구)

  • Xiang, Zhao;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1230-1235
    • /
    • 2019
  • In this paper, we have developed sensor composited heater of 2-pin, and unified the fuel filter. In order to evaluate the performance of the 2-pin sensor composited fuel heater, we have make of the low temperature fluidity system. The one measure and analysis the electrical and oil flow quantity characteristics at an input and out port of 2-pin sensor composited fuel heater. Especially, in the characteristics verification elements of the proposed goods, we use the test chamber for the temperature variable and oil flow quantity test, and designed an embedded system for interfacing an engine. By interfacing both user and the system, it support an experimental and date gathering function in 2-pin sensor composited fuel filter. And then test the temperature, oil pressure, electrical characteristics and oil flow quantity in variable status from - 30 ℃ to + 80 ℃. These can help us to determine the quality and performance of elementary goods.

Characteristics of Water Temperature Inversion Observed in a Region West of Jeju Island in April 2015 (2015년 4월에 제주 서부해역에서 발생한 수온역전층 특성)

  • Kim, Seong Hyeon
    • Ocean and Polar Research
    • /
    • v.42 no.2
    • /
    • pp.97-113
    • /
    • 2020
  • In-situ observations were carried out in April 2015 to investigate the occurrence of water temperature inversion in a region west of Jeju Island. Analysis of in-situ in the western part of Jeju island showed that cold water moved to the southeast from the surface to the middle layer and warm water moved from the middle to the lower layer of the northwest direction. The water temperature inversion occurred at 84 stations (63.1%) out of 133 stations. At the boundary of the water temperature inversion layer, it was formed in the middle layer and disappeared. In the strongly appearing, it started from the middle layer to the lower layer. The shape of the water temperature inversion layer was different. As a result of horizontal water temperature slope analysis of the water temperature inversion zone, maximum 0.23℃/km was obtained and the mean was 0.06℃/km. The role of water temperature inversion as an indicator to determine the formation of water front. As a result of the water mass analysis, Jeju Warm Current Water and Tsushima Warm Current Water of high temperature and high salt intruded from the middle to the bottom. In the middle layer occurred as the Yellow Sea Cold Water of low water temperature and low salinity expanded.

A Numerical Study on the Heat Transfer Characteristics of a Metal Hydride Reactor with Embedded Heat Pipes (내부에 히트파이프를 삽입한 메탈 하이드라이드 반응기의 열전달 특성에 대한 수치해석 연구)

  • Park, Young-Hark;Boo, Joon-Hong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2346-2351
    • /
    • 2008
  • This study deals with heat pipes inserted into the metal hydride(MH) reactor to increase the effective thermal conductivity of the system and thus to enhance the thermal control characteristics. A numerical analysis was conducted to predict the effect of inserted heat pipes on the heat transfer characteristics of MH, which inherently has extremely low thermal conductivity. The numerical model was a cylindrical container of O.D. 76.3 mm and length 1 m, which is partially filled with about 60% of MH material. The heat pipe was made of copper-water combination, which is suitable for operation temperature range between $10^{\circ}C$ and $80^{\circ}C$. Both inner -and outer- heat pipes were considered in the model. Less than two hours of transient time is of concern when decreasing or increasing the temperature for absorption and discharge of hydrogen gas. FLUENT, a commercial software, was employed to predict the transient as well as steady-state temperature distribution of the MH reactor system. The numerical results were compared and analyzed from the view point of temperature uniformity and transient time up to the specified maximum or minimum temperatures.

  • PDF

A Study of Spray Characteristics of Injector on the Air-assisted Pressure Variation (보조 공기 압력 변화에 따른 인젝터의 분무 특성에 관한 연구)

  • Yoon, S.H.
    • Journal of ILASS-Korea
    • /
    • v.3 no.4
    • /
    • pp.58-64
    • /
    • 1998
  • In the gasoline engine of fuel injection type, atomization of fuel droplet and its distribution has directly influenced the performance of engine and harmful emission. To investigate atomization characteristics of fuel spray, in this paper fuel spray of air-assisted injector is observed at the various initial conditions of ambient air temperature and air assisted pressure. Behavior of fuel spray is photographed with microscopic visualization system. The SMD of fuel droplet is measured with PMAS (Particle Motion Analysis System). The effect of air-assisted pressure and temperature of ambient air resulted in the decrement of SMD and its variation. Finally, It was found that It was found that from spray angle at the two-hole injector had measured $20{\pm}4$ degree the result of photographs by shadow graphy. The mean diameter of suns decreased and the of droplets increased with increasing the temperature in the spray fields by the results of PMAS measurement. It was found that the characteristics of sprays became finer by increasing the temperature of spray fields about 373K without the delivery of air-assistance.

  • PDF

The Effects of Urban Forest on Summer Air Temperature in Seoul, Korea (도시림의 여름 대기온도 저감효과 - 서울시를 대상으로 -)

  • 조용현;신수영
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.4
    • /
    • pp.28-36
    • /
    • 2002
  • The main purpose of this study was to estimate a new regression model to explain the relationship between urban forest and air temperature in summer, 2001. This study consists of two parts: correlation coefficient analysis and regression analysis. According to correlation coefficient analysis, thermal infra-red radiations of the major land use categories found significant difference in each category. However there were no significant relationship between the data (thermal infra-red radiation and NDVI) derived from Landsat-7 ETM+ image and air temperature at Automatic Weather Stations(AWSs). After estimating various regression models for summer air temperature, the final models were chosen. The final regression models consisted of two variables such as forest m and traffic facilities area. The regression models explained over 78% of the variability in air temperatures. The regression models with variables of forest area and traffic facilities area showed that the coefficient of the first variable was even more significant than the second one. However, the negative impact of the traffic facilities area was slightly greater than the positive impact of the forest area. Consequently, the effects of forest area and traffic facilities area were apparent to explain summer air temperature in Seoul. Therefore two policies have the most important implications to mitigate the summer air temperature in Seoul: to expand and to conserve the urban forest; and to change the Oafnc facilities'characteristics. The results from this study are expected to be useful not merely in informing the public that urban forest mitigates summer air temperahne, but in urging the necessity of budgets for trees and managing urban forests. It is recommended that field swey of summer air temperature be Performed for the vadidation of the models. The main purpose of this study was to estimate a new regression model to explain the relationship between urban forest and air temperature in summer, 2001. This study consists of two parts: correlation coefficient analysis and regression analysis. According to correlation coefficient analysis, thermal infra-red radiations of the major land use categories found significant difference in each category. However there were no significant relationship between the data (thermal infra-red radiation and NDVI) derived from Landsat-7 ETM+ image and air temperature at Automatic Weather Stations(AWSs). After estimating various regression models for summer air temperature, the final models were chosen. The final regression models consisted of two variables such as forest m and traffic facilities area. The regression models explained over 78% of the variability in air temperatures. The regression models with variables of forest area and traffic facilities area showed that the coefficient of the first variable was even more significant than the second one. However, the negative impact of the traffic facilities area was slightly greater than the positive impact of the forest area. Consequently, the effects of forest area and traffic facilities area were apparent to explain summer air temperature in Seoul. Therefore two policies have the most important implications to mitigate the summer air temperature in Seoul: to expand and to conserve the urban forest; and to change the traffic facilities'characteristics. The results from this study are expected to be useful not merely in informing the public that urban forest mitigates summer air temperature, but in urging the necessity of budgets for trees and managing urban forests. It is recommended that field survey of summer air temperature be Performed for the vadidation of the models.

Analysis of Soot Formation Characteristics in Diffusion Flames with Soot Particle Temperature Measurement (매연입자 온도 측정에의한 확산화염의 매연생성 특성 해석)

  • Lee, Won-Nam;Chung, Young-Hyun
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.241-249
    • /
    • 1999
  • Soot particle temperatures in co-flow diffusion flames have been measured using a two-color pyrometry at the pressure of 0.2 MPa(2 atm). The measured soot particle temperatures along with the integrated soot volume fractions are analyzed to understand soot formation characteristics. At 0.2 MPa, the addition of small amount of air into ethylene do not change the soot particle temperature in soot formation regions. This result showed that the increase of soot formation with addition of air is mostly due to the chemical effect of the added air, such as the increased role of C3 chemistry during the early stage of soot inception process. The addition of sufficient air into ethylene, however, changes soot particle temperatures and the understanding of soot formation characteristics becomes complicated. Measured soot particle temperatures also showed that there is no significant temperature effect for the synergistic effect of ethylene/propane mixture on soot formation.

  • PDF