• Title/Summary/Keyword: Temperature Variation Rate

Search Result 994, Processing Time 0.031 seconds

A Study on the Fatigue Crack Propagation Behavior by the Variation of Heat Treatment Temperature and Thickness in ATOS 55 Steel (ATOS 55강의 열처리 온도와 두께 변화에 따른 피로균열성장거동에 관한 연구)

  • 오환교
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.15-20
    • /
    • 1997
  • This study is to investigate the behavior of fatigue crack growth with ATOS 55 steel which can be applied to the commercial car Dump Frame. It is to obtain the material coefficients after tensile and fatigue crack growth test with the variation of thickness or heat treatment. Also, that is proved the Pari's law by experiment. The summarized results are as follows ; 1) Increasing thickness, tensile and yield strength measured highly regardless to heat treatment and measured lowly as variation of heat treatment temperature. 2) Specimen of thickness 8.0㎜ measured the faster of crack growth rate than another thickness according to the results of experiment. It was the different of stress conditions in crack tip. 3) It was found that the experimental constant m was range of 2∼5 to the relationship between fatigue crack growth rate and stress intensity factor range. Also, it was to prove the Paris's law by the experiment.

  • PDF

Intraspecific Variation in the Temperature Niche Component of the Diatom Skeletonema costatum from Korean Coastal Waters

  • YIH Wonho;SHIM Jae Hyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.6
    • /
    • pp.805-811
    • /
    • 1995
  • Final biomass yields (peak optical density) and growth rates (divisions/day) of seven clones of Skeletonema costatum from Korean coastal waters were measured to understand their intraspecific variations in the light intensity niche component under $25^{\circ}C$ condition. Daily growth rates of 6 of 7 S. costatum, clones were maximum at 6000 lux while that of YS4, a neritic clone, was maximum at 9000 lux. The final biomass yields of 4 of the 7 S. costatum clones were maximum at the lowest light intensity of 2000 lux. Minimum final biomass yields were found at 9000 lux in all the S. costatum clones other than an estuarine clone, HDC9. The intraspecific variations of the mean growth rate and mean final biomass yield under each of the three different light intensity in terms of the coefficient of variation were not greater than 10% in any of the 7 S. costatum clones.

  • PDF

Seawater Temperature Variation at Aquafarms off Wando in the Southwest Coast of Korea (완도 양식장 해역의 수온변동)

  • Yang, Joon-Yong;Lee, Joon-Soo;Han, In-Sung;Choi, Yong-Kyu;Suh, Young-Sang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.6
    • /
    • pp.514-519
    • /
    • 2012
  • Abalone culture is one of important coastal fisheries off Wando in the southeast coast of Korea. Since cage culture for abalones was popularized, Understanding of temperature variation, which is important to raise abalones and to prevent their mass mortalities, is necessary. We analyzed temperature data from 2005 to 2009 obtained at Sinji-do and Cheongsan-do off Wando. Sinji-do, which is relatively close to land, had yearly wide range of temperature and rate of temperature variation. It is likely to be caused by heating of solar radiation in summer and cooling in winter at the shallow area. Rate of temperature variation in autumn was higher than that in spring. In summer short term variation of temperature corresponding tidal period was distinguished clearly. Diurnal temperature range, abrupt temperature change, was larger open sea. Comparison between temperatures of two stations and favorable raising conditions of abalones showed that Cheongsan-do, located out to sea, appears to be more appropriate than Sinji-do.

The Outlet Temperature Prediction of In-Situ Thermal Response Test using CFD Analysis (CFD 해석을 이용한 현장 열응답 시험의 출구온도 예측)

  • Sim, Yong-Sub;Lee, Hee-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.28-35
    • /
    • 2016
  • The in-situ thermal response test for the design of a ground heat exchanger of geothermal heat pumps have difficulty in predicting the outlet temperature according to the variation of conditions due to the expense and time. This paper suggests a 3-D CFD analysis method to predict the heat transfer performance of vertical type ground heat exchanger, which is mostly used in national, and the outlet temperature and the slope of two in-situ thermal response tests were compared to test the proposed CFD reliability. The results of CFD analysis showed that the outlet temperature was predicted to within $0.5^{\circ}C$ of the actual value and the slope was predicted to within 1.6%. The reliability of the CFD analysis method was confirmed using this process, and the outlet temperature prediction of the two in-situ thermal response tests was obtained by changing ${\pm}20%$ of the flow rate and the effective thermal conductivity conditions, respectively. The results of CFD analysis showed that the outlet temperature of Case 1 was 28.0 (-20%) and $29.6^{\circ}C$ (+20%) for the flow rate variation and $29.6^{\circ}C$ (-20%) and $28.0^{\circ}C$ (+20%) for the effective thermal conductivity variation, and the outlet temperature of Case 2 was 28.4 (-20%) and $29.8^{\circ}C$ (+20%) for the flow rate variation and $29.7^{\circ}C$(-20%) and $28.4^{\circ}C$(+20%) for the effective thermal conductivity variation.

A Study on Dielectric Properties of PCW-PNN-PZT ceramics (PCW-PNN-PZT계 세라믹의 유전 특성에 관한 연구)

  • Shin, Hye-Gyeong;Lee, Sung-Ho;Jung, Bo-Ram;Bae, Seon-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.51-53
    • /
    • 2005
  • This study was to measure the minuteness structure, dielectric properties of 0.03PCW-0.07PNN-0.9PZT ceramics according to sintering temperature manufacture the specimens with a general method. The results of this study were gotten such as follows. The crystal structure of ceramic changed the rombohedral structure into teteragonal structure according to rising sintering temperature in XRD. Dielectric constant at $20^{\circ}C$ showed its maximum value 510.599 in specimens sintered at $1100^{\circ}C$ and dielectric loss showed its minimum value 7.43% in specimens sintered at $1100^{\circ}C$. The variation rate of dielectric constant according to the change of frequency showed its minimum value 0.029/kHz at $1100^{\circ}C$. The variation rate of dielectric constant according to the change of temperature showed its minimum value $1.40/^{\circ}C$ at $1500^{\circ}C$.

  • PDF

Temporal Variation of Air Temperature in Ice-Valley at Milyang in Association with Ice Formation

  • Lee, Soon-Hwan;Hwang, Soo-Jin
    • Journal of the Korean earth science society
    • /
    • v.28 no.5
    • /
    • pp.598-602
    • /
    • 2007
  • A long-term in situ observation was carried out in the Ice-valley at Milyang in order to explain the factors and processes associated with the summertime ice formation. The variation of temperature inside Ice-valley in relation with ice formation in summer time was found to depend on precipitation rate in spring and cold air sinking in autumn and winter. The rate of temperature rising tends to correspond to sensible heat release depending on the precipitation amount at the freezing location. The reason of the cold air accumulation in a talus in the Ice-valley is the cold air sinking over the surface of talus due to the occurrence of outside clod air mass and the accumulated cold air from autumn to spring flow outside at the bottom of talus. The out-flowing cold air can result in the ice formation in the hot summer.

Relationship between Clearance Rates and Metal Uptake Rates of Corbicula fluminea, Potamocorbula amurensis and Macoma balthica: Influence of Water Temperature and Body Size (세 종의 이매패류 Corbicula fluminea, Potamocorbula amurensis, Macoma balthica의 여수율과 금속 흡수율과의 관계에 대한 연구)

  • Lee, Jung-Suk;Lee, Byeong-Gwon
    • The Korean Journal of Malacology
    • /
    • v.21 no.1
    • /
    • pp.41-46
    • /
    • 2005
  • A series of radiotracer studies were conducted to evaluate the influence of water temperature and/or body size on the clearance rates and uptake rates of Cd, Se and Zn in the Asiatic clam, Corbicula fluminea, Asian clam Potamocorbula amurensis and Balthic clam, Macoma balthica. Uptake rates of Cd, Se and Zn were estimated simultaneously with clearance rate of clams under 3 different water temperature conditions (5, 13 and $21^{\circ}C$). The weight specific clearance and metal uptake rates of P. amurensiswere increased with temperature, however, no consistent temperature effect was observed for the other clams. The variation of uptake rates of Cd, Se and Zn along with temperature or body size in each clam species was well associated with clearance rates. The inter-species as well as the intra-species difference of metal uptake rates could be well explained by the variation of clearance rates of clam individuals.

  • PDF

A Study on Ultrasonic Technique for Measuring Gas Temperature (기체온도 측정을 위한 초음파 계측에 관한 연구)

  • Yoon, Cheon Han;Choi, Young;Jeon, Heung Shin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.893-900
    • /
    • 1999
  • Measuring temperature with ultrasonic wave apparatus is desirable in the cue of gas below $300^{\circ}$ because of the fact that the temperature of gas is the function of only sound velocity. In this study, being used a heatable wind channel and a blower. the variation of temperature is observed in accordance with flow rate(air velocity). The frequency modulation method is used to measure the temperature which is varying in hot air flow up to $100^{\circ}$. The length changed in the position of ultrasonic sensors is considered. Also. the effects of air velocity at the same temperature and various facing angles of ultrasonic sensors are considered. As a result of this study. it has been found that the temperature in gas flow is correctly measured regardless of both the distance of ultrasonic sensors and the variation of air velocity. and that there is just a little influence of facing angles.

The Seasonal Variation of the Heat Budget in Deukryang Bay (득량만의 열수지 계절 변동)

  • 주용환;조규대
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.67-73
    • /
    • 1998
  • Surface heat budget of the Deukryang Bay from July 1, 1992 to September 12, 1993 is analyzed by us- ing the meteorological data (by Changhung Observatory and Mokpo Meteorological Station) and oceanogaphical data (by Research Center for Ocean Industrial Development. Pukyong National University). Each flux element at the sea surface which has annual variation Is derived with application of an aerodynamical bulk method and empirical formulae. The solar radiation Is the maximum In spring and sensible heat are the maximum in autumn and water. and minimum in summer The heat .storage rate is calclilated by using the rate of water temperature variation according to the depth. The oceanic transport heat is estimated as a residual. The net heat flux, the heat storage rate are positive In spring and summer, while they are negative in autumn and winter. The oceanic transport heat Is convergence In winter and divergence In the rest of seasons.

  • PDF

Temperature monitoring and seasonal borehole heat exchange rate characteristics of a geothermal heat pump system (지열 히트펌프 시스템의 계절별 지중 열교환 특성 및 지반내 온도 변화)

  • Shim, Byoung-Ohan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.452-455
    • /
    • 2007
  • The geothermal heat pump system is designed for cooling and heating for three stories building (2,435 $m^2$) includes total 79 heat pumps. Therefore, the monitoring system is installed for each floor and the data is automatically transmitted to the monitoring system. Heat exchange rate and temperature of a geothermal heat pump system have been monitored for a long period. The seasonal operation of geothermal heat pump shows the different shape of heat exchange rate for cooling and heating. Ground water flow can influence on heat exchange rate and thermal storage of the system. In order to define the hydraulic characteristics and groundwater temperature variation, the relationships among air temperatures, groundwater temperatures, water table, and precipitation are analysed.

  • PDF