• 제목/요약/키워드: Temperature Trend

검색결과 1,295건 처리시간 0.034초

이종계면에서의 주파수 및 온도 변화에 따른 유전특성 (Dependencies of Dielectric Properties on Frequency and Temperature in Different Interfaces)

  • 강대용;오광영;이종복;한상옥;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1605-1607
    • /
    • 1998
  • In this paper, specimens which have the structure of Insulator/Insulator/Insulator and Insulator/Semiconductor /Insulator were experimented using insulating material of Polyethylene Terephthalate(PET). The dependency of permitivity, $tan{\delta}$ and conductance on frequency and temperature were investigated. Both of the specimens showed the trend of decrease in permitivity as the temperature increased but increase as the frequency increased. $tan{\delta}$ of both specimens showed increase with the increase of frequency. With the temperature, $tan{\delta}$ showed slight decrease by $60^{\circ}C$ and increase over $80^{\circ}C$.

  • PDF

고령자 온열 쾌적감 간이 측정방법 개발에 관한 연구 (Study for the development of portable thermal comfort measurement tool for elderly)

  • 배치혜;이현정;전정윤
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.15-20
    • /
    • 2009
  • The purpose of this study is to develop of portable thermal comfort measurement tool for elderly. Using prediction expression of thermal comfort for elderly which derived at previous study, a field studies were conducted. The objects of this survey are old persons over 60 years old and total 296 (male:111 persons, female:145 persons) persons were measured. The actual thermal sensation was compared with predicted thermal sensation calculated with PMV model, and the results shows that there were no correlation between them. Also, appling cheek temperature and hand temperature were useful to predict thermal sensation of elderly people. Especially, predicted thermal sensation using cheek temperature were closely connected with actual thermal sensation of elderly and presented most similar trend to actual thermal sensation.

  • PDF

배전설비의 온라인 모니터링과 진단 기술 동향 (A Technical Trend on On-Line Condition Monitoring and Diagnostics of Power Equipments)

  • 임완수;이태우;여운철;이성길;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1974-1975
    • /
    • 2007
  • Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system. The paper presents the results of wireless temperature monitoring of switchgear at a power plant over a two-year period.

  • PDF

반응표면분석 법을 이용한 인삼우유 중 사포닌 추출조건의 최적화 (Optimization of Saponin Extraction Conditions in Ginseng Milk using Response Surface Methodology)

  • 이승수;박종면
    • Journal of Ginseng Research
    • /
    • 제18권1호
    • /
    • pp.53-59
    • /
    • 1994
  • To develop the methodology of the quantitative analysis of saponin in ginseng milk, conditions of the saponin extraction were optimized using the fractional factorial design with 3 variables and 3 levels by a RSM computer program. The extraction of saponin increased with an increase in extraction temperature up to $90^{\circ}C$ and then decreased significantly at $100^{\circ}C$. Extraction time affected the saponin yield in a similar trend. On the other hand, decreasing cooling temperature increased the amount of the saponin extracted. Recovery yield of the saponin from ginseng milk varied from 70.0% to 92.9%. The optimum extraction temperature, time and cooling temperature determined by partial differentiation of the model equation were $86^{\circ}C$, 2.83 hrs and $4^{\circ}C$, respectively. Key words Ginseng milk, saponin, response surface methodology.

  • PDF

A study of predicting irradiation-induced transition temperature shift for RPV steels with XGBoost modeling

  • Xu, Chaoliang;Liu, Xiangbing;Wang, Hongke;Li, Yuanfei;Jia, Wenqing;Qian, Wangjie;Quan, Qiwei;Zhang, Huajian;Xue, Fei
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2610-2615
    • /
    • 2021
  • The prediction of irradiation-induced transition temperature shift for RPV steels is an important method for long term operation of nuclear power plant. Based on the irradiation embrittlement data, an irradiation-induced transition temperature shift prediction model is developed with machine learning method XGBoost. Then the residual, standard deviation and predicted value vs. measured value analysis are conducted to analyze the accuracy of this model. At last, Cu content threshold and saturation values analysis, temperature dependence, Ni/Cu dependence and flux effect are given to verify the reliability. Those results show that the prediction model developed with XGBoost has high accuracy for predicting the irradiation embrittlement trend of RPV steel. The prediction results are consistent with the current understanding of RPV embrittlement mechanism.

Thermal-hydraulic behavior simulations of the reactor cavity cooling system (RCCS) experimental facility using Flownex

  • Marcos S. Sena;Yassin A. Hassan
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3320-3325
    • /
    • 2023
  • The scaled water-cooled Reactor Cavity Cooling System (RCCS) experimental facility reproduces a passive safety feature to be implemented in Generation IV nuclear reactors. It keeps the reactor cavity and other internal structures in operational conditions by removing heat leakage from the reactor pressure vessel. The present work uses Flownex one-dimensional thermal-fluid code to model the facility and predict the experimental thermal-hydraulic behavior. Two representative steady-state cases defined by the bulk volumetric flow rate are simulated (Re = 2,409 and Re = 11,524). Results of the cavity outlet temperature, risers' temperature profile, and volumetric flow split in the cooling panel are also compared with the experimental data and RELAP system code simulations. The comparisons are in reasonable agreement with the previous studies, demonstrating the ability of Flownex to simulate the RCCS behavior. It is found that the low Re case of 2,409, temperature and flow split are evenly distributed across the risers. On the contrary, there's an asymmetry trend in both temperature and flow split distributions for the high Re case of 11,524.

A review of Magnetic Refrigeration Technology

  • Jeong S.;Numazawa T.;Rowe A.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권2호
    • /
    • pp.1-10
    • /
    • 2006
  • This paper reviews the magnetic refrigeration technology that is a novel cooling method utilizing magnetic field to obtain low temperature. The key component of the refrigeration is a novel magnetic refrigerant which should possess sufficiently large magneto-caloric effect so that a pseudo-Carnot magnetic refrigeration cycle can cover reasonably large temperature span. Otherwise, a regenerative concept should be employed to expand the temperature span of the refrigeration cycle. There is a growing interest in magnetic refrigeration as a viable refrigeration technology not only for cryogenics as well as room temperature range. This paper covers historical developments, fundamental concepts, key components, application classification, and recent research trend of magnetic refrigerators.

한국의 이상기온 출현 빈도의 변화와 그 요인에 관한 연구 (Changes of Unusual Temperature Events and their Controlling Factors in Korea)

  • 허인혜;이승호
    • 대한지리학회지
    • /
    • 제41권1호
    • /
    • pp.94-105
    • /
    • 2006
  • 본 연구에서는 우리나라의 여름과 겨울철의 이상기온 출현 빈도의 변화와 그에 영향을 미치는 요인과의 관계를 파악하고자 하였다. 우리나라의 대부분 관측 지점에서는 여름철 이상고온 출현 빈도의 증가와 겨울철 이상저온 출현 빈도의 감소 경향이 뚜렷하다. 이러한 이상기온 출현 빈도의 변화는 대기 순환 지수 중 겨울철 이상기온 출현에 영향을 미치는 겨울 몬순 지수와 시베리아 고기압 강도 지수 및 북극 진동 지수, 그리고 여름철 이상저온 출현에 영향을 미치는 오호츠크해 고기압 강도 지수와 북태평양 지수 등의 변화 경향과 유사하다. 이 지수들은 이상기온의 변화에 영향을 미치는 요인 중 최근의 지구 온난화 경향을 반영하며 우리나라 전 지역의 이상기온 출현 빈도와 관계가 뚜렷하다.

최근 40년(1979~2018) 우리나라 겨울 일 평균기온의 장기 변화 경향 및 주기 분석 (Long-term Trend and Period Analysis of Korean Daily Temperature During Winter Season of 40 Years (1979~2018))

  • 최지영;황승언;예상욱;송세용;김윤재
    • 대기
    • /
    • 제29권5호
    • /
    • pp.599-607
    • /
    • 2019
  • The change and periodicity of Korean winter temperature in the period 1979-2018 are investigated. It is shown that the winter temperature is on a long-term rise, with two regime shifts of winter temperature during 40 years. In addition, the decrease in cold days is confirmed along with the rise in temperature. Analysis of the periodicity of daily temperature in winter is carried out by means of power spectral analysis. Of the spectral peaks that are statistically significant, the most frequent detection exists on the time scale between 7 and 8 days. It is found that the number of significant periods have decreased since 2014, particularly no longer existent around the period of 7 day. The longer periods than 7 days gradually increase during 40 years, while the shorter periods show the tendency of decrease but recently rebound. Spectral analysis calculated from high/low-pass filtered daily temperature data also shows similar results.

Enhancement of thermoelectric properties of MBE grown un-doped ZnO by thermal annealing

  • Khalid, Mahmood;Asghar, Muhammad;Ali, Adnan;Ajaz-Un-Nabi, M.;Arshad, M. Imran;Amin, Nasir;Hasan, M.A.
    • Advances in Energy Research
    • /
    • 제3권2호
    • /
    • pp.117-124
    • /
    • 2015
  • In this paper, we have reported an enhancement in thermoelectric properties of un-doped zinc oxide (ZnO) grown by molecular beam epitaxy (MBE) on silicon (001) substrate by annealing treatment. The grown ZnO thin films were annealed in oxygen environment at $500^{\circ}C-800^{\circ}C$, keeping a step of $100^{\circ}C$ for one hour. Room temperature Seekbeck measurements showed that Seebeck coefficient and power factor increased from 222 to $510{\mu}V/K$ and $8.8{\times}10^{-6}$ to $2.6{\times}10^{-4}Wm^{-1}K^{-2}$ as annealing temperature increased from 500 to $800^{\circ}C$ respectively. This observation was related with the improvement of crystal structure of grown films with annealing temperature. X-ray diffraction (XRD) results demonstrated that full width half maximum (FWHM) of ZnO (002) plane decreased and crystalline size increased as the annealing temperature increased. Photoluminescence study revealed that the intensity of band edge emission increased and defect emission decreased as annealing temperature increased because the density of oxygen vacancy related donor defects decreased with annealing temperature. This argument was further justified by the Hall measurements which showed a decreasing trend of carrier concentration with annealing temperature.