• Title/Summary/Keyword: Temperature Monitor

Search Result 683, Processing Time 0.028 seconds

Enhancement of Blood Compatibility of Albumin-Immobilized Polyurethane

  • Gyu Ha Ryu;Don
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.269-274
    • /
    • 1992
  • In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.raph.

  • PDF

Structural performance monitoring of an urban footbridge

  • Xi, P.S.;Ye, X.W.;Jin, T.;Chen, B.
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.1
    • /
    • pp.129-150
    • /
    • 2018
  • This paper presents the structural performance monitoring of an urban footbridge located in Hangzhou, China. The structural health monitoring (SHM) system is designed and implemented for the footbridge to monitor the structural responses of the footbridge and to ensure the structural safety during the period of operation. The monitoring data of stress and displacement measured by the fiber Bragg grating (FBG)-based sensors installed at the critical locations are used to analyze and assess the operation performance of the footbridge. A linear regression method is applied to separate the temperature effect from the stress monitoring data measured by the FBG-based strain sensors. In addition, the static vertical displacement of the footbridge measured by the FBG-based hydrostatic level gauges are presented and compared with the dynamic displacement remotely measured by a machine vision-based measurement system. Based on the examination of the monitored stress and displacement data, the structural safety evaluation is executed in combination with the defined condition index.

CLINICO-HAEMATOLOGICAL AND BIOCHEMICAL ALTERATIONS IN ETHYLENE GLYCOL INDUCED ACUTE NEPHROTOXICITY IN COW CALVES

  • Singh, D.P.;Kumar, M.;Sharma, S.P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.8 no.1
    • /
    • pp.7-11
    • /
    • 1995
  • Ethylene glycol was given orally in 6 crossbred male cow calves @ 12 ml/kg b wt for 2 days continuously to develop acute nephrotoxicity and monitor blood chemicals profile in affected calves. Progressive depression, hypersalivation, ataxia, incoordination, staggering gait, grinding of teeth, recumbency, coma, convulsions and death were prominent symptoms in affected calves. Respiration and pulse rates were increased whereas body temperature and rumen movements were low. Haematological investigations revealed increase in total erythrocyte count, platelets count and packed cell volume till death and total leukocyte count up to day 3 which decreased on day 4 and 5. These calves revealed azotaemia, reduction in calcium, chloride and potassium and rise in sodium and AST, ALT and alkaline phosphatase enzymes activity.

Experimental study on the capacity of pilot scale FBC for paper sludge (Pilot plant 규모 유동충 소각로의 제지 슬러지 소각 용량에 관한 실험적 연구)

  • La, Seung-Hyuck;Moon, Dong-Jin;Kang, Kyung-Tae;Shin, Dong-Hoon;Hwang, Jung-Ho
    • 한국연소학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.199-203
    • /
    • 2002
  • In this paper, the effects of water contents on combustion characteristics of paper sludge and capacity of fluidized bed combustor(FBC) were investigated using 0.26m diameter, 1.75m height pilot-plant scale combustor. Combustion tests of paper sludge containing water contents between 40wt% and 50wt% were performed. The temperature and emission variation, the pressure inside combustor were measured to monitor the fluidization quality. The experimental results showed that 30kg/hr feeding rate of sludge containing water up to 45wt% was preferable for this system. Sludge loading rate, heat release rate were calculated from experimental data as major parameters showing FBC capacity. Comparsion with sludge loading rate from other source was also performed

  • PDF

Remote Patient Monitoring Service through World-Wide Web (Web을 통한 원격 환자 모니터링 서비스)

  • Lee, H.S.;Park, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.188-191
    • /
    • 1997
  • In this paper, we present a real-time remote patient monitoring service through world-wide web, which allows the medical doctor to monitor his patients in remote sites using popular web browsers. The real-time service consists of two services: Patient Locator Service (PLS) and Vital Sign Monitoring Service (VSMS). The PLS provides the information of patients currently being monitored. The VSMS allows the user to observe a stream of vital sign data of a specific patient. The vital sign data include ECG, respiration, temperature, $SPO_2$, invasive blood pressure and non-invasive blood pressure.

  • PDF

Development of Deterioration Detecting Sensor in Oil for Diagnosis of Oil-Filled Transformers (유입 변압기 진단을 위한 유중 열화 측정 센서의 개발)

  • Min, Kyeoung-Rae;Yoon, Yong-Han;Kim, Young-Chun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.128-130
    • /
    • 2000
  • This paper develops the deterioration detecting sensor in oil to monitor and diagnose oil-filled transformer more effectively. The on-line inspection of the oil-filled transformers used the temperature, the changes of the capacitance, the $tan{\delta}$ in oil. This sensor was designed based on the concentric cylindrical type so that it could be placed inside of the oil-filled transformer. And comparing to the existing system, it was proven to be appropriate. Establishment of the proposed sensor helps to build the confidence in monitoring of the oil-filled transformers.

  • PDF

An Experimental Study on the Measurement of Soot Contamination in a Diesel Engine Oil (디젤 엔진오일 내 Soot 함량 증가에 따른 오염도 측정에 관한 실험적 고찰)

  • 공호성;조성용;윤의성;한흥구;정동윤
    • Tribology and Lubricants
    • /
    • v.19 no.5
    • /
    • pp.251-258
    • /
    • 2003
  • New method and device for the on-line measurement of soot concentration in a diesel engine oil are proposed, where the measurement principle is based mainly on attenuated internal total reflection. The detector were evaluated in various ranges of contaminated oils by carbon black particles. It was found that the proposed detector could be well used to monitor the oil deterioration due to soot contamination. Operational range of the detector was found from 0 to 5 mass percentage of soot content. Test results with water and fuel dilution showed that these effects were not remarkable. However, adsorption of carbon black particles onto the measurement surface was considered to be a critical problem of the detector. Effects of particle deposition on the interface was experimentally evaluated with the oil temperature and flow turbulence and discussed throughout this work.

Characterization of Crystal Structure for Nanosized Noble Metal Particles Fabricated by ERC(Evaporation and Rapid Condensation) Method (증기급속응축법 제조 귀금속 나노분말의 결정학적 특성 연구)

  • Yu, Yeon-Tae
    • Korean Journal of Materials Research
    • /
    • v.13 no.5
    • /
    • pp.285-291
    • /
    • 2003
  • The nanosized silver and gold particles are prepared by ERC method in which metal vapors with high temperature is rapidly quenched by coolants such as liquid nitrogen or liquid argon. In order to monitor the crystal structural changes on the internal and the surface of the nanosized noble metal particles, lattice parameter, internal strain and Debye-Waller factor are investigated, and the calculation of X-ray diffraction scattering intensity is performed. The lattice parameters of silver and gold particles agree with those of bulk materials, and crystal internal strain of the metal particles is not changed by rapid cooling. The Debye-Waller factor of gold particles is increased with decreasing particle size because of the surface softening phenomenon of nanosized particles, but the crystal structural change on the surface of the particles is not detected from the comparison the calculated X-ray diffraction profile with the experimental profile on gold particles with the particle size of 4 nm.

Error Prediction System for Distribution Feeders: Hardware Design and Its Implementation (수배전반 설비의 고장 예측 시스템: 하드웨어 설계 및 구현)

  • Kim, Dong-Sik;Cho, Sang-Young;Chung, Beom-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1087-1088
    • /
    • 2008
  • In this paper, an error prediction system for the distribution feeders is designed and implemented. In order to monitor the signals of voltages, currents, temperatures, and sounds, and then analyze the signals, an ARM9-based processor board is used and numerous programmable gain amplifiers, temperature sensors, filters are implemented based on a low single voltage system.

  • PDF

Personal Computer Based System for the Measurement and Control of Environmental Factors (Personal Computer를 이용한 環境因子의 計測 및 制御 System에 관한 연구)

  • Lee, Hyeong-Choon;Kim, Tae-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.13 no.1
    • /
    • pp.35-40
    • /
    • 1987
  • Personal computer based measurement and control system was constructed and tested in order to fiexibly apply it to laboratoy experiments in which environmental factors such as temperature, humidity, pH, DO and gases should be measured and controlled. Personal computer FC-80 was successively interfaced to the input-output system made up of PPI, A/D converter, D/A converter, programmable timer and USART boards. To test the system, pH control experiment was executed and the pH of the solution could be measured, expressed on the monitor and controlled at constant value.

  • PDF