• Title/Summary/Keyword: Temperature History of Concrete

Search Result 137, Processing Time 0.023 seconds

Field Application of the Mass Concrete Using Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather (이중버블시트를 이용한 단열보온양생공법의 한중매스콘크리트 현장적용)

  • Lee, Dong-Gyu;Kim, Jong;Kim, Ki-Hoon;Hwang, Yin-Seong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.1-4
    • /
    • 2007
  • This study investigated the applicability of insulation curing method with double layer bubble sheets to the man concrete subjected to cold weather. Temperature history of the mass concrete indicated that the highest temperature of center section was exhibited at $34^{\circ}C$ while the that of surface section was $25^{\circ}C$. Difference between center and surface was shown to be less $10^{\circ}C$ when the temperature of center section was peak section, and thereby associated temperature cracking index was calculated 1.5, and occurrence probability of temperature cracking was 5%, so there was no temperature cracking caused by internal restraint. No temperature crack was observed by naked eye. It was clear that early frost demage and temperature cracking could be restrained due to reducing temperature difference between inner part and outside in the case double bubble sheets applied to insulation curing method in cold weather. The maturity of mass concrete is higher than outside about $72\sim89^{\circ}$ DD, so it was demonstrated to prevent early frost demage and ensure strength excellently. Insulation curing method with double bubble sheets was more economic than heating curing method.

  • PDF

Thermal Stress Analysis of the Heat Generation for Mass Concrete Considering Creep Effect (크리이프를 고려한 매스콘크리트의 수화열에 대한 온도응력 해석)

  • Kim, Jin Keun;Lee, Jong Dae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.771-781
    • /
    • 1994
  • The heat generation of cement causes the internal temperature rise and volume change at early age, particulary in massive concrete structures. As the results of the temperature rise and restraint conditions, the thermal stress may induce cracks in concrete. Therefore, the prediction of the thermal stress is very important in the design and construction in order to control the cracks developed in mass concrete. In case of young concrete, creep effect by the temperature load is larger than that of old concrete. Thus, the effect of creep must be considered for checking the cracks, serviceability, durability and leakage. This paper is concentrated on the development of a finite element program which is capable of simulating the temperature history and the thermal stress considering creep and the modified elastic modulus due to inner temperature change and maturity. The analytical results in the inner parts highest important to control cracks are in good agreement with experimental data. Therefore this study may provide available method to control the cracks.

  • PDF

Temperature background characteristics of concrete according to changes in bubble sheet types in hot weather environments (서중환경에서 버블시트 종류 변화에 따른 콘크리트의 온도이력 특성)

  • Lee, Jea-Hyeon;Lee, Jae-Jin;Lee, Sang-Un;Lee, Joung-Gyo;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.132-133
    • /
    • 2016
  • This research team has developed single silk white bubble sheets to be used as surface sheath curing material for spring, summer, and autumn. But though its effects for spring and autumn temperature conditions have been proved, there haven't been any studies for summer temperature conditions. Therefore in this study, single silk white bubble sheets and single silk transparent bubble sheets as well as aluminum metalizing single silk bubble sheets have been applied to actual box-frame apartment slabs in construction, in order to compare temperature backgrounds of the concrete and other qualities. Upon application, the temperature of concrete cured in summer temperature conditions showed excellent scores, being the lowest for aluminum metalizing single silk white bubble sheets, then single silk transparent bubble sheets. But the aluminum metalizing single silk bubble sheet gave off a harmful glare, so for actual use, white single silk bubble sheets are recommended.

  • PDF

Prevention of Early Frost Damage of the Concrete under Severely Low Temperature according to Heat Curingmethods (극저온 조건에서 보온양생 방법 변화에 따른 콘크리트의 초기동해 방지)

  • Han, min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.1
    • /
    • pp.67-76
    • /
    • 2016
  • Concrete exposed to severely low temperature below $-20^{\circ}C$ should be provided with proper heat supplying curing to protect the concrete from early frost damage at the time of pouring.meanwhile, so far, effective heat curingmethods of the concrete under severely low temperature are not well established in Korea. For this reason, the objective of this paper is to provide effective heat curingmethod of concrete exposed to severely low temperature to protect early frost damage by varying the combination of heat curingmaterial combinations. Temperature history,maturity development and core strength results are investigated. Fourmock-up specimens simulating slab, wall and column were prepared and heat insulation, heat supplying and both were applied. Test results indicate that the combination of quadruple layer bubble sheet(4BS) and embedding of heating cable has desirable performance for a slab, and heat supplying curing inside heat enclosure and heat generationmat also shows desirable performance for a wall, and for a column, use of EPS heat insulation has proper performance against early frost damage, which reaches $45^{\circ}D{\cdot}D$ and helps the concretemaintain above $0^{\circ}C$ within 3 days. Themethodsmentioned above are believed to be optimum protection from early frost damage of the concrete under $-20^{\circ}C$.

A Numerical Analysis of Steel Structures on a Subway Station Fire (지하철정거장 화재에 대한 강구조물의 내화해석)

  • Bang, Myung-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.123-127
    • /
    • 2010
  • A fire disaster is very serious in the closing space like subway station. In this study, the simulation on fire diffusion is performed to get the temperature history curve, which is used for the fire resisting structural analysis. Most of subway stations are built by the reinforced concrete structure, but recently steel structures are selected for the larger space or beauty. Steel structures relatively have more weaknesses against fire, so it is necessary to develop the method for evaluating fire-resisting capacity in this kind of structures. The developed method is applied to the subway station in Daegu city. It shows that the developed method can be used to simulate the fire disaster and to get the temperature history curve and evaluate the safety of steel structures against the fire.

An Experimental Study on the Influence of Heat of Hydration in High Strength Concrete during Hardening Process (고강도콘크리트의 내부온도이력과 경화콘크리트의 특성에 관한 실험적 연구)

  • 윤영수;이승훈;박희민;성상래;백승준;장일영;신성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.127-132
    • /
    • 1994
  • This study attemps to investigate the influence of heat of hydration occured during hardening on the strength development of high strength concrete. The concrete design strengths of 500kg/$\textrm{cm}^2$ and 700kg/$\textrm{cm}^2$ were considered to simulated the square columns having $80\times80cm$ and $100\times100cm$, respectively. Both standard curing and field curing specimen were prepared at the specified ages, and the cores were drilled out from the structure. The thermal sensors were installed into the specimen to measure the heat of hydration process occurred during the hardening. This paper tries to uncover the relationship between the temperature history of the concrete and strength development. The correlation of core strength and specimen strength with curing condition is also discussed. Further research is desired to enlight the relationship between strength and heat of hydration of high strength concrete.

  • PDF

Veriation of Pore Structure of High Strength Concrete Including Silica Fume Exposed to High Temperature (고온에 노출된 실리카퓸 혼입 고강도 콘크리트의 공극구조 변화)

  • Song Hun;Soh Yang-Seob
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.597-604
    • /
    • 2004
  • This work involves quantitatively investigating the correlation between reductions in strength and variations in pore structure under high temperature that can be utilized as estimation for predicting the inner temperature of member damaged by fire. The experimental results were remarkedly affected by micro-filling effect of silica fume and the different water-binder ratios. The increase of the exposure temperature caused the increase of porosity, which resulted from the reason that evaporable water in gel pore or capillary pores as well as chemically bound water was eliminated from hardened cement paste due to the dehydration of C-S-H and $Ca(OH)_2$. Thermal shrinkage of hardened cement paste gives rise to micro-crack, which cause the increase of porosity. Based on the experimental result that the increase of porosity is in charge of exposure temperature, how porosity is distributed can predict temperature-time history and assess the performance of concrete damaged by fire.

Temperature Characteristics depending on the Changes of Surface-coated Curing Methods by using some bubble sheets during winter (동절기 버블시트 표면피복 양생방법 변화에 따른 철근의 온도특성)

  • Lee, Jea-Hyeon;Kyung, Yeong-Hyeok;Lee, Sang-Un;Lee, Joung-Gyo;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.13-14
    • /
    • 2016
  • In the modern construction industry, since numerous skyscrapers have been built, there have been sought for developing various kinds of methods for shortening a construction period. Therefore, many kinds of studies on some kinds of cold-weather concrete have been conducted actively for the purpose of a year-round construction. Accordingly, this research team once developed a double-layered bubble sheet as a surface-coated curing material for winter. And there have been raised some worries that some initial damages to frozen concrete caused by low temperature of reinforcing bars which are exposed out of the wall areas of a wall-type apartment during winter. Therefore, in this study, it is intended to find out clearly whether it is possible for concrete to be damaged initially or not by analyzing the temperature characteristics of the exposed reinforcing bars of the wall areas under the temperature conditions during winter.

  • PDF

Development of Integrated Wireless Sensor Network Device with Mold for Measurement of Concrete Temperature (콘크리트 온도 측정을 위한 거푸집 일체형 무선센서네트워크 장치 개발)

  • Lee, Sung Bok;Park, Seong Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.129-136
    • /
    • 2012
  • Temperature of fresh concrete can be effectively used to predict the strength of concrete being cured and make an informed decision for stripping the molds. A hygrothermograph and thermo-couple sensors that require an extensive wiring have been applied to measure a temperature of concrete at the early stage of the curing process on site. However, these methods have limits to provide the temperature data in real time due to harsh working environment including frequent cutting of wires. Therefore, this study is aiming at developing a device based on wireless sensor network to measure the temperature of concrete being cured in formwork. The result showed that the wireless sensor with probe type thermistor which is developed had the same temperature data compared to the existed wire type thermistor, and we confirmed the temperature history of concrete in real time for 28 days throughout the gateway by wireless network that collects the temperature data measured from specimens in laboratory. Also, the network device for transmission can be easily separated from the probe sensor part and reused consistently. If the wireless sensor network device developed uses in the field, the temperature management of concrete will be systematically conducted from at the early stage of the curing, and especially be effective for cold weather concrete construction. In addition, it will contribute to the establishment of advanced quality control system for concrete and productivity of supervisors on site will be increased in the future.

Identification of Compliance Function for Early-Age Concrete Based on Measured Strain & Thermal Stress Histories (변형률 및 열응력 이력 계측을 통한 초기재령 콘크리트의 컴플라이언스 함수 추정)

  • Oh, Byung-Hwan;Shin, Joon-Ho;Choi, Seong-Cheol;Cha, Soo-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.5
    • /
    • pp.662-669
    • /
    • 2003
  • Recently, the serviceability and durability of concrete structures under thermal load have received great attention. The thermal stress and clacking behavior of concrete at early ages are one of the important factors that affect such serviceability and durability of concrete structures. Nevertheless, most studies on the behavior of early-age concrete have been confined to the temperature and strain development itself in the laboratory. The desirable efforts to explore the material properties of concrete at early-ages have not been made extensively so far. The purpose of the present study is, therefore, to identify some important material properties that affect the stress behavior of concrete at early-ages. To this end, full-scale concrete base-restrained wall members have been fabricated, and many sensors including thermocouples, strain meters and stress meters were installed inside of the wall members. These sensors were to measure the development of temperatures, strains and stresses at several location in concrete walls during the hardening and curing phase of early-age concrete. By using these measured values of strain and stress, the compliance function at early-age was identified. The basic form of compliance function derived in this study follows the double-power law. However, the results of present study indicate that the values of existing compliance functions are much lower than actual values, especially at very early-ages. It can be seen that the prediction of stresses of early-age concrete based on the proposed compliance function agrees very well with test data. The present study allows more realistic evaluation of varying stresses in early-age concrete under thermal load.