• Title/Summary/Keyword: Temperature Failure

Search Result 1,324, Processing Time 0.026 seconds

Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files

  • Charlotte Gouedard;Laurent Pino;Reza Arbab-Chirani;Shabnam Arbab-Chirani;Valerie Chevalier
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.2
    • /
    • pp.16.1-16.9
    • /
    • 2022
  • Objectives: This study compared the cyclic fatigue resistance of One Curve (C wire) and F6 Skytaper (conventional austenite nickel-titanium [NiTi]), and 2 instruments with thermos-mechanically treated NiTi: Protaper Next X2 (M wire) and Hyflex CM (CM wire). Materials and Methods: Ten new instruments of each group (size: 0.25 mm, 6% taper in the 3 mm tip region) were tested using a rotary bending machine with a 60° curvature angle and a 5 mm curvature radius, at room temperature. The number of cycles until fracture was recorded. The length of the fractured instruments was measured. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). The data were analyzed using one-way analysis of variance and the post hoc Tukey test. The significance level was set at 0.05. Results: At 60°, One Curve, F6 Skytaper and Hyflex CM had significantly longer fatigue lives than Protaper Next X2 (p < 0.05). No statistically significant differences were found in the cyclic fatigue lives of One Curve, F6 Skytaper, and Hyflex CM (p > 0.05). SEM images of the fracture surfaces of the different instruments showed typical features of fatigue failure. Conclusions: Within the conditions of this study, at 60° and with a 5 mm curvature radius, the cyclic fatigue life of One Curve was not significantly different from those of F6 Skytaper and Hyflex CM. The cyclic fatigue lives of these 3 instruments were statistically significantly longer than that of Protaper Next.

A Study on the Development of Charging Algorithm for Battery Charger Control Unit of the T-50 Series Aircraft (T-50 계열 항공기 배터리 시스템의 충전제어장치 알고리즘 개선에 관한 연구)

  • Jaejeong Kim;Soonyoung Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.6
    • /
    • pp.144-148
    • /
    • 2023
  • Aircraft battery is the core equipment of an aircraft that supplies engine starting power and emergency power, and it must be charged to ensure sufficient capacity at all times and maintain high reliability to ensure stable power supply. The battery of the T-50 series aircraft is designed to enable the engine to start up to two times in temperatures as low as -18℃ and above. However, intermittent failures in engine starting have been observed during winter. In this paper, we analyze the failure phenomena occurring during low-temperature charging of the battery and improve the charging algorithm based on the analysis and test. Additionally, the results of start simulation tests show that the battery charging defects at low temperatures are resolved, and an improvement in the charging performance is confirmed; thus, validating the effectiveness of the new algorithm.

Fabrication of Pt/Carbon Nanotube Composite Based Electrochemical Hydrogen Sulfide Gas Sensor using 3D Printing (3D 프린팅을 이용한 Pt/Carbon Nanotube composite 기반 전기화학식 황화수소 가스 센서 제작)

  • Yuntae Ha;JinBeom Kwon;Suji Choi;Daewoong Jung
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.290-294
    • /
    • 2023
  • Among various types of harmful gases, hydrogen sulfide is a strong toxic gas that is mainly generated during spillage and wastewater treatment at industrial sites. Hydrogen sulfide can irritate the conjunctiva even at low concentrations of less than 10 ppm, cause coughing, paralysis of smell and respiratory failure at a concentration of 100 ppm, and coma and permanent brain loss at concentrations above 1000 ppm. Therefore, rapid detection of hydrogen sulfide among harmful gases is extremely important for our safety, health, and comfortable living environment. Most hydrogen sulfide gas sensors that have been reported are electrical resistive metal oxide-based semiconductor gas sensors that are easy to manufacture and mass-produce and have the advantage of high sensitivity; however, they have low gas selectivity. In contrast, the electrochemical sensor measures the concentration of hydrogen sulfide using an electrochemical reaction between hydrogen sulfide, an electrode, and an electrolyte. Electrochemical sensors have various advantages, including sensitivity, selectivity, fast response time, and the ability to measure room temperature. However, most electrochemical hydrogen sulfide gas sensors depend on imports. Although domestic technologies and products exist, more research is required on their long-term stability and reliability. Therefore, this study includes the processes from electrode material synthesis to sensor fabrication and characteristic evaluation, and introduces the sensor structure design and material selection to improve the sensitivity and selectivity of the sensor. A sensor case was fabricated using a 3D printer, and an Ag reference electrode, and a Pt counter electrode were deposited and applied to a Polytetrafluoroethylene (PTFE) filter using PVD. The working electrode was also deposited on a PTFE filter using vacuum filtration, and an electrochemical hydrogen sulfide gas sensor capable of measuring concentrations as low as 0.6 ppm was developed.

The Analysis of Mapping Errors Induced in Learning the Concept of Reaction Rate with Analogies, and the Comparison of Mapping Errors by Analogy Presentation Types (비유를 사용한 반응 속도 개념 학습에서 유발되는 대응 오류에 대한 분석과 비유 표현 방식에 따른 비교)

  • Kim, Kyung-Sun;Byun, Ji-Sun;Lee, Seon-Woo;Kang, Hun-Sik;Noh, Tae-Hee
    • Journal of The Korean Association For Science Education
    • /
    • v.28 no.4
    • /
    • pp.340-349
    • /
    • 2008
  • This study investigated the mapping errors induced in learning the concept of reaction rate with analogies, and compared these mapping errors by the analogy presentation types. Tenth graders (N=418) at a high school were assigned to the four groups by the target concepts and the analogy presentation types. The target concepts were 'concentration and reaction rate' and 'temperature and reaction rate'. In presenting analogy, the verbal and the verbal/pictorial analogs were used. After the students learned one of the analogs, a mapping test was administered. From the analysis, eight types of mapping errors were identified: overmapping, artificial mapping, failure to map, rash mapping, mismapping, mapping of a superficial feature, retention of a base feature, and impossible mapping. According to the analogy presentation types and the features of the target concepts, there were some differences in the frequencies of mapping errors. Educational implications of these findings are discussed.

Reliability Prediction of High Performance Mooring Platform in Development Stage Using Safety Integrity Level and MTTFd (안전무결성 수준 및 MTTFd를 활용한 개발단계의 고성능 지상체 신뢰도 예측 방안)

  • Min-Young Lee;Sang-Boo Kim;In-Hwa Bae;So-Yeon Kang;Woo-Yeong Kwak;Sung-Gun Lee;Keuk-Ki Oh;Dae-Rim Choi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.3
    • /
    • pp.609-618
    • /
    • 2024
  • System reliability prediction in the development stage is increasingly crucial to reliability growth management to satisfy its target reliability, since modern system usually takes a form of complex composition and various complicated functions. In most cases of development stage, however, the information available for system reliability prediction is very limited, making it difficult to predict system reliability more precisely as in the production and operating stages. In this study, a system reliability prediction process is considered when the reliability-related information such as SIL (Safety Integrity Level) and MTTFd (Mean Time to Dangerous Failure) is available in the development stage. It is suggested that when the SIL or MTTFd of a system component is known and the field operational data of similar system is given, the reliability prediction could be performed using the scaling factor for the SIL or MTTFd value of the component based on the similar system's field operational data analysis. Predicting a system reliability is then adjusted with the conversion factor reflecting the temperature condition of the environment in which the system actually operates. Finally, the case of applying the proposed system reliability prediction process to a high performance mooring platform is dealt with.

Development of an Unmanned Land-Based Shrimp Farm Integrated Monitoring System (무인 육상 새우 양식장 통합 모니터링 시스템 개발)

  • Hyeong-Bin Park;Kyoung-Wook Park;Sung-Keun Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.1
    • /
    • pp.209-216
    • /
    • 2024
  • Land shrimp farms can control the growth environment more stably than coastal ones, making them advantageous for high-quality, large-scale production. In order to maintain an optimal shrimp growth environment, various factors such as water circulation, maintaining appropriate water temperature, oxygen supply, and feed supply must be managed. In particular, failure to properly manage water quality can lead to the death of shrimp, making it difficult to have people stationed at the farm 24 hours a day to continuously manage them. In this paper, to solve this problem, we design an integrated monitoring system for land farms that can be operated with minimal manpower. The proposed design plan uses IoT technology to collect real-time images of land farms, pump status, water quality data, and energy usage and transmit them to the server. Through web interfaces and smartphone apps, administrators can check the status of the farm stored on the server anytime, anywhere in real time and take necessary measures. Therefore, it is possible to significantly reduce field work hours without the need for managers to reside in the farm.

An Experimental Study on Mechanical Properties of Ultra-High Strength Powder Concrete (압축강도 300MPa 이상의 초고강도 분체콘크리트 개발을 위한 실험적 연구)

  • Jo, Byung-Wan;Yoon, Kwang-Won;Park, Jung-Hoon;Kim, Heoun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.287-295
    • /
    • 2010
  • In this study, ordinary Portland cement was used and the air void was minimized by using minute quartz as the filler. In addition, steel fibers were used to mitigate the brittle failure problem associated with high strength concrete. This study is in progress to make an Ultra-high strength powdered concrete (UHSPC) which has compressive strength over 300 MPa. To increase the strength of concrete, we have compared and analyzed the compressive strengths of the concretes with different mix proportions and curing conditions by selecting quartz sand, dolomite, bauxite, ferro silicon which have diameters less than 0.6 mm and can increase the bond strength of the transition zone. Ultra-high strength powdered concrete, which is different from conventional concrete, is highly influenced by the materials in the mix. In the study, the highest compressive strength of the powdered concrete was obtained when it is prepared with ferro silicon, followed in order by Bauxite, Dolomite, and Quartz sand. The amount of ferro silicon, when the highest strength was obtained, was 110%, of the weight of the cement. SEM analysis of the UHSPC showed that significant formation of C-S-H and Tobermorite due to high temperature and pressure curing. Production of Ultrahigh strength powdered concrete which has 28-day compressive strength upto 341MPa has been successfully achieved by the following factors; steel fiber reinforcement, fine particled aggregates, and the filling powder to minimize the void space, and the reactive materials.

Multiple accelerated degradation test and failure analysis for $Ni-BaTiO_3$ MLCCs ($Ni-BaTiO_3$ MLCCs에 대한 복합 가속 열화 시험 및 고장 분석)

  • Kim, Jung-Woo;Kim, Jin-Seong;Lee, Hee-Soo;Kang, Do-Won;Kim, Jeong-Wook
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.2
    • /
    • pp.102-105
    • /
    • 2009
  • The accelerated life time test of the MLCCs with different $BaTiO_3$ particle sizes were conducted at $150^{\circ}C$, 75 V condition and the effect of $BaTiO_3$ particle size on the breakdown voltage and degradation characteristics of MLCCs was investigated. The MLCCs were prepared by using the $BaTiO_3$ particles having the size of $0.525{\mu}m$, $0.555{\mu}m$, $0.580{\mu}m$ and Ni-electrode, respectively. The MLCCs which have the particle size of $0.525{\mu}m$, $0.555{\mu}m$, and $0.580{\mu}m$, respectively were confirmed to meet the standard requirements of X5R(change capacitance within ${\pm}15%$ at $-55{\sim}85^{\circ}C$) by TCC(Temperature Coefficient of Capacitance). The effect of the $BaTiO_3$ particle size on the insulation resistance behavior of MLCCs was confirmed by BDV(Breakdown Voltage) measurements and the cause and degree of degradation of MLCCs were characterized by XPS analysis after the accelerated life test. The MLCCs with $0.525{\mu}m-BaTiO_3$ showed better insulation resistance and BDV characteristics compare to other MLCCs and XPS analysis revealed that the MLCCs degradation is caused by the NiO peak and $BaTiO_3$ peak decrease.

Study on Rainfall infiltration Characteristics for Weathered Soils: Analysis of Soil Volumetric Water Content and Its Application (국내 풍화토의 강우 침투특성 분석을 위한 실험연구: 토양 체적함수비 분석 및 적용성 평가)

  • Kim, Man-Il;Chae, Byung-Gon;Cho, Yong-Chan;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.18 no.1
    • /
    • pp.83-92
    • /
    • 2008
  • In order to analyze infiltration characteristics of rainfall in soil, two laboratory experiments were conducted using an amplitude domain reflectometry (ADR) sensor and a pore water pressure meter (PWP) in this study. The first experiment is to understand the dependency of volumetric water content and temperature for standard sand and weathered granite soil. The second experiment is a laboratory flume test with changes of rainfall condition. As the results of the dependency experiment, the volumetric water content is increased with increase of the output voltage measured by the ADR sensor in both the standard sands and weathered granite soil. Furthermore, the results also indicate necessity of consideration of the temperature dependency under the condition of high volumetric water contents from 0.15 to 0.45. In the flume test, two measurement devices are detected to the variation of volumetric water content and pore water pressure at the installation point of the flume. In especial, the measured values of ADR4 and PWP3 installed on the lower part of slope are higher than those of the others. It means that the lower part of slope plays a role of a runoff face and a beginning point of slope failure.

Characteristics Measurement of Hyperelastic SMA Gear for Micro-jitter Attenuation of X-band Antenna of Compact Advanced Satellite (차세대중형위성 적용가능성 검토를 위한 X-band 안테나의 미소진동 저감용 초탄성 SMA 기어의 특성 측정)

  • Jeon, Young-Hyeon;Back, Hyeon-Gyu;Song, Da-Il;Kang, Eun-Su;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.9
    • /
    • pp.784-793
    • /
    • 2017
  • A two-axis gimbal-type X-band antenna mounted on an observation satellite can efficiently transmit high-capacity image data to a ground station regardless of both the satellite position and the orbital motion. However, this X-band antenna induces unnecessary micro-jitter which can degrade the image quality of the high-resolution observation satellite. Therefore, to achieve the high-resolution image quality from the observation satellite, micro-jitters have been required to be isolated. In this study, to resolve aforementioned drawback, we proposed blade gear using a shape memory alloy (SMA) applied to azimuth stage of X-band antenna. To investigate the rotational basic characteristics of the proposed SMA blade gear, we performed rotational static loading test. Futhermore, to evaluate the cycle to failure of the gear, accelerated life test was conducted. The temperature test was conducted to confirm rotational basic characteristics at various temperature conditions. To verify the isolation performance for micro-jitter, we performed micro-jitter measurement test.