• 제목/요약/키워드: Temperature Difference Ratio

검색결과 788건 처리시간 0.03초

극저온의 흡기 온도 조건에서 실린더 내 디젤 연료의 분무 특성 (Spray Characteristics of Diesel Fuel in a Cylinder under Cryogenic Intake Air Temperature Conditions)

  • 민세훈;서현규
    • 한국분무공학회지
    • /
    • 제26권1호
    • /
    • pp.18-25
    • /
    • 2021
  • The objective of this study is to investigate the effect of cryogenic intake air temperature on the injected fuel droplet behavior in a compression ignition engine under the different start of energizing timing. To achieve this, the intake air temperatures were changed from -18℃ to 18℃ in steps of 9℃, and the result of fuel evaporation rate, Sauter mean diameter, and equivalence ratio distributions were compared. When the intake air temperature decreased in steps of 9℃, less fuel was evaporated by about 3.33% because the cylinder temperature was decreased. In addition, the evaporated fuel amount was increased with retarding the start of energizing timing because the cylinder temperature raised. However, the difference was decreased according to the retarded start of energizing timing because the cylinder pressure was also increased at the start of fuel injection. The equivalence ratio was reduced by 5.94% with decreasing the intake air temperature. In addition, the ignition delay was expected to longer because of the deteriorated evaporation performance and the reduced cylinder pressure by the low intake air temperature.

열전소자의 열적조건 변화에 따른 발전 특성 (Performance of Thermoelectric Power Generator with Various Thermal Conditions)

  • 한훈식;김명기;엄석기;김서영
    • 설비공학논문집
    • /
    • 제22권3호
    • /
    • pp.165-170
    • /
    • 2010
  • Experiments have been performed to investigate the key parameters determining the performance of thermoelectric power generation. The experimental results obtained show that the power output significantly increases with the temperature difference between cold and hot sides of thermoelectric generator. However, the effect of the hot side temperature under the identical temperature difference on the overall performance of a thermoelectric generator is meager. The conversion efficiency defined as the ratio of the power generated to the heat absorbed at the hot side increases with the temperature difference. The behavior of the thermoelectric generator is shown to be consistent with the theoretical analysis. The optimum current giving the maximum conversion efficiency and the maximum conversion efficiency are linearly increased with the temperature difference.

도시지역의 토지피복유형이 지표면온도에 미치는 영향: 경기도 일산 신도시를 중심으로 (Effect of the Urban Land Cover Types on the Surface Temperature: Case Study of Ilsan New City)

  • 김현옥;염종민
    • 대한원격탐사학회지
    • /
    • 제28권2호
    • /
    • pp.203-214
    • /
    • 2012
  • 콘크리트와 아스팔트가 상당 부분을 차지하는 도시의 물리적인 환경은 도시열섬효과를 일으키는 주요 원인이며, 일차적으로 토지이용 또는 토양피복에 따른 지표면온도의 상승으로 나타난다. 본 연구에서는 도시의 토지피복유형이 지표면온도에 미치는 영향을 공간해상도가 다른 MODIS, Landsat ETM+과 RapidEye 위성영상을 사용하여 비교 분석해 보았다. 연구대상지인 일산 신도시지역의 지표면온도는 토지 이용에 따라 뚜렷이 구분되는 패턴을 보여주었는데 건폐율이 높은 저층단독주택지구보다 건폐율이 낮고 녹지율이 높은 고층 아파트단지의 지표면온도가 현저히 낮게 나타났다. 토지피복유형과의 관계는 건물이나 도로 등 도시화지역의 면적이 증가할수록 기후존의 지표면온도가 증가하고, 식생과 수면, 그림자 지역의 면적이 늘어날수록 지표면온도는 떨어진다. NDVI와 지표면온도 사이에도 음의 선형상관관계가 나타나지만, 계절적 영향을 배제하기 어렵다는 단점이 있다.

변형 2색법에 의한 예혼합기 연소의 연소가스온도 측정에 관한 연구 (A Study on the Measurement of Burnet Gas Temperature in Premized Combustion by Modified Two-Color Method)

  • 배명환
    • 한국자동차공학회논문집
    • /
    • 제7권8호
    • /
    • pp.43-54
    • /
    • 1999
  • The effects of equivalence ratio and pressure on burnt gas temperature in premixed fuel rich propane-oxygen-inert gas combustion are investigated over the wide ranges of equivalence ration from 1.5 to 2.7 and pressure from 0.1 to 7 MPa by using a specially designed disk -type constant-voume combustion chamber, The premixtures are simultaneously ignited by eight spark plugs located on the circumference of combustion chamber with 45 degree interals. The eight converging flames compress the end gases to high pressures. The burnt gas temperature is meausured by the nmodifie dtow-colr pyrometry method. The transmissivity in the chamber center during the final stage of combustion at the hightest pressure is meausred by in situ laser extinction method. It is found that a temperature difference between the burnt gas temperature measured by mofidied and conventrational two-color method is 10 to 20 K, but the accuracy of the modified two-color methdo is higher if the local transmissivity in observed region is uniform , and the combustion at higher pressures results gas density conditions and the burnt gas temperature increases as the volume fraction of argon is increased because the specific heat of argon is lower compared to that of nitrogen with a constant equivalence ratio.

  • PDF

공기공급 시스템에 적용되는 Vortex Tube의 에너지 분리특성에 관한 연구(I) -저온출구 orifice의 직경변화에 의한 영향- (A Study for Energy Separation of Vortex Tube using Air Supply System (I) - the effect of diameter of cold end orifice -)

  • 이병화;추홍록;상희선
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.9-18
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air supply system. The phenomena of energy separation through the vortex tube was investigated experimentally. This study is focused on the effect of the diameter of cold end orifice diameter on the energy separation. The experiment was carried out with various cold end orifice diameter ratio from 0.22 to 0.78 for different input pressure and cold air flow ratio. The experimental results were indicated that there are an optimum diameter of cold end orifice for the best cooling performance. The maximum cold air temperature difference was appeared when the diameter ratio of the cold end orifice was 0.5. The maximum cooling capacity was obtained when the diameter ratio of the cold end orifice was 0.6 and cold air flow ratio was 0.7.

  • PDF

On thermal stability of plates with functionally graded coefficient of thermal expansion

  • Bousahla, Abdelmoumen Anis;Benyoucef, Samir;Tounsi, Abdelouahed;Mahmoud, S.R.
    • Structural Engineering and Mechanics
    • /
    • 제60권2호
    • /
    • pp.313-335
    • /
    • 2016
  • In this article, a four-variable refined plate theory is presented for buckling analysis of functionally graded plates subjected to uniform, linear and non-linear temperature rises across the thickness direction. The theory accounts for parabolic distribution of the transverse shear strains, and satisfies the zero traction boundary conditions on the surfaces of the plate without using shear correction factor. Young's modulus and Poisson ratio of the FGM plates are assumed to remain constant throughout the entire plate. However, the coefficient of thermal expansion of the FGM plate varies according to a power law form through the thickness coordinate. Equilibrium and stability equations are derived based on the present theory. The influences of many plate parameters on buckling temperature difference such ratio of thermal expansion, aspect ratio, side-to-thickness ratio and gradient index will be investigated.

발열 전도체가 존재하는 밀폐계 내부의 자연대류 현상에 대한 수치적 연구 (Numerical Simulation of Natural Convection in Horizontal Enclosure with Heat-Generating Conducting Body)

  • 이재룡;하만영
    • 대한기계학회논문집B
    • /
    • 제29권4호
    • /
    • pp.441-452
    • /
    • 2005
  • The physical model considered here is a horizontal layer of fluid heated below and cold above with heat-generating conducting body placed at the center of the layer. The dimensionless thermal conductivities of body considered in the present study are 0.01, 1 and 150. The dimensionless temperature difference ratios considered are 0.25, 2.5 and 25. Two-dimensional solution for unsteady natural convection is obtained using an accurate and efficient Chebyshev spectral methodology for variety of Rayleigh number from $10^{3}\;to\;10^{6}.$ Multi-domain technique is used to handle square- shaped heat-generating conducting body. The results for the case of conducting body with heat generation are also compared to those without heat generation.

Thermal buckling resistance of simply supported FGM plates with parabolic-concave thickness variation

  • Benlahcen, Fouad;Belakhdar, Khalil;Sellami, Mohammed;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • 제29권5호
    • /
    • pp.591-602
    • /
    • 2018
  • This research presents an investigation on the thermal buckling resistance of FGM plates having parabolic-concave thickness variation exposed to uniform and gradient temperature change. An analytical formulation is derived and the governing differential equation of thermal stability is solved numerically using finite difference method. A specific function of thickness variation is introduced where it controls the parabolic variation intensity of the thickness without changing the original material volume. The results indicated that the loss ratio in buckling resistance is the same for any gradient temperature profile. Influencing geometrical and material parameters on the loss ratio in the thermal resistance buckling are investigated which may help in design guidelines of such complex structures.

SHS법에 의한 고온발열체용 $MoSi_2$의 합성 및 소결 (Synthesis and Sinteirng of $MoSi_2$ by SHS Process)

  • 이승재;장윤식;김인술;박홍채;오기동
    • 한국세라믹학회지
    • /
    • 제32권9호
    • /
    • pp.1085-1091
    • /
    • 1995
  • Molybdenum disilicide (MoSi2) was synthesized from Mo, MoO3, Si and Al powders by self-propagating high temperature synthesis (SHS). The effect of processing parameters such as Mo/MoO3 molar ratio, Ar gas pressure in the reactor and pressing pressure of compacts in synthesis of MoSi2 were investigated. h-MoSi2 was transformed into t-MoSi2 with increasing the Mo/MoO3 mole ratio, and only t-MoSi2 phase was identified above 3.5 : 1 (molar ratio). The synthesized phases did not change with the variation of Ar gas pressure and pressing pressure of compacts. It was found that the combustion temperature was above 2,50$0^{\circ}C$. The products were separated into MoSi2 (s) and $\alpha$-Al2O3 by the difference of their specific grativities. Bending strength, hardness and density of sintered specimen exhibited 82 MPa, 5.368 GPa and 5.43 g/㎤, respectively.

  • PDF

습공기선도 상에 20 종류의 상태 및 과정 값의 작도 (Drawing of Twenty Kinds of State and Process on Psychrometric Chart)

  • 김덕진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1201-1206
    • /
    • 2008
  • Psychrometric chart displays graphically the thermophysical properties of moist air, so it is very conveniently used in air-conditioning and refrigeration. On general psychrometric chart, there are dry bulb temperature, web bulb temperature, absolute humidity ratio, relative humidity, specific enthalpy, specific volume, sensible heat factor, and enthalpy-humidity difference ratio. However, various state and process values besides aboves can be plotted on psychrometric chart. In this study, we developed the software drawing twenty kinds of lines, that is vapor pressure, mole fraction ratio of vapor, dew point temperature, degree of saturation, density, specific entropy, specific exergy, contact or bypass factor, uncomfort index, discomposition index, predicted mean vote index, predicted percent dissatisfied, and so on. We wish to this software is a help to design, analysis and education.

  • PDF