• 제목/요약/키워드: Temperature Difference Energy

검색결과 1,101건 처리시간 0.032초

Effects of Temperature Stress on VFB Shifts of HfO2-SiO2 Double Gate Dielectrics Devices

  • Lee, Kyung-Su;Kim, Sang-Sub;Choi, Byoung-Deog
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.340-341
    • /
    • 2012
  • In this work, we investigated the effects of temperature stress on flatband voltage (VFB) shifts of HfO2-SiO2 double gate dielectrics devices. Fig. 1 shows a high frequency C-V of the device when a positive bias for 10 min and a subsequent negative bias for 10 min were applied at room temperature (300 K). Fig. 2 shows the corresponding plot when the same positive and negative biases were applied at a higher temperature (473.15 K). These measurements are based on the BTS (bias temperature stress) about mobile charge in the gate oxides. These results indicate that the positive bias stress makes no difference, whereas the negative bias stress produces a significant difference; that is, the VFB value increased from ${\Delta}0.51$ V (300 K, Fig. 1) to ${\Delta}14.45$ V (473.15 K, Fig. 2). To explain these differences, we propose a mechanism on the basis of oxygen vacancy in HfO2. It is well-known that the oxygen vacancy in the p-type MOS-Cap is located within 1 eV below the bottom of the HfO2 conduction band (Fig. 3). In addition, this oxygen vacancy can easily trap the electron. When heated at 473.15 K, the electron is excited to a higher energy level from the original level (Fig. 4). As a result, the electron has sufficient energy to readily cross over the oxide barrier. The probability of trap about oxygen vacancy becomes very higher at 473.15 K, and therefore the VFB shift value becomes considerably larger.

  • PDF

열전모듈의 냉각특성에 관한 실험적 연구 (An experimental study on cooling characteristic of a thermoelectric module)

  • 황준;강병하
    • 한국수소및신에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.341-347
    • /
    • 2004
  • An experimental study has been carried out on cooling perfonnance of a thennoelectric module. This problem is of particular interest in the design of the refrigeration systems using thermoelectric module, such as cosmetic refrigerator, wine cellar and air cooler. The effect of the input voltage and the hot side temperature on the cooling performance is studied in detail. The $\Delta$T, temperature difference between cold side and hot side surface of thermoelectric module, is described in terms of the input voltage and the hot side temperature. It is found that the cooling capacity can be improved by increasing the input voltage and by reducing the heat from the hot side of the thermoelectric module. However, COP is decreased with an increase in the input voltage, since power consumption is also increased. Thus, optimum input voltage can be selected based on cooling capacity and COP.

사각형(四角形) 단면(斷面)을 가진 반경(半徑)핀에서의 열전달(熱傳達)에 관(關)한 연구(硏究) (A Study on the Heat Transfer in Radial Fin of Rectangular Profile)

  • 김광수;임장순;서정일
    • 태양에너지
    • /
    • 제2권1호
    • /
    • pp.24-32
    • /
    • 1982
  • In this paper, temperature distributions in radial fin of rectangular profile for steady-state with no heat generation are obtained by one-dimensional analytical method, finite difference method and experiment respectively. Heat flow rate and fin efficiency from the fin model are obtained by analytical method. Consequently, temperature distributions in radial fin can certify that are similar to exact solution. From theoretical analysis, the effects according to heat flow rate and fin efficiency are related to variation of parameters which are fin thickness ${\delta}_o$, fin base temperature $T_o$, thermal conductivity K with same basic dimensions and the effects are studied and compared.

  • PDF

Fatigue life curves of alloy 617 in the temperature range of 800-950℃

  • Injin Sah;Jaehwan Park;Eung-Seon Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.546-554
    • /
    • 2023
  • The cyclical behavior of Alloy 617 was examined at 25 ℃ and high temperatures of 800, 850, 900, and 950 ℃ in air to obtain its fatigue life curves. The specimens tested at 25, 800, and 850 ℃ cyclically hardened, whereas those tested above 900 ℃ cyclically softened from the first cycle, that is, their fatigue life was reduced at high temperatures owing to loss of strength. Parameters of the typical Coffin-Manson-Basquin relationship were determined for each test temperature. Interestingly, no significant difference in fatigue life was observed for the specimens tested in the range of 800-950 ℃. Owing to the similarity in fatigue life, we determined fatigue strength and fatigue ductility exponents that could be applied for this temperature range. The parameters obtained were close to the universal slopes, although the fatigue ductility exponent was slightly different. The proposed fatigue life curves were compared with those presented in ASME code.

하수처리수를 이용한 2단 압축 열펌프 시스템의 운전특성에 관한 연구 (A Study on The Operation Characteristics of 2-Stage Compression Heat Pump using Treated sewage)

  • 김지영;백영진;이영수;장기창;나호상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.299-303
    • /
    • 2008
  • The treated sewage temperature is about $5^{\circ}C$ lower in summer and $5{\sim}10^{\circ}C$ higher in winter than ambient air. It can be used heat pump heat source and is good heat source on high performance of heat pump. In this study, to develop 100RT 2-stage compression heat pump use treated sewage water heat source and system applies to sewage disposal plant. Although heat pump is better performance, the large temperature difference between load and source makes the performance degradation of a heat pump. To solve this problem screw 2-stage compression is considered. The experiment was focused on the system operating performance variations over supply water and treated sewage water a temperature in the field. The results show that system of heating performance is higher then general heat pump and is enough to supply a hot water of $70^{\circ}C$.

  • PDF

전기히터식 및 지열원 히트펌프식 농산물 열풍건조기의 에너지 성능 비교 (Energy Performance Comparison of Electric Heater and Geothermal Source Heat Pump type Agricultural Hot Air Dryers)

  • 양원석;김영일;박승태
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.7-12
    • /
    • 2018
  • Energy performance of electric heater and geothermal source heat pump type hot air dryers are compared in this study. For set temperatures of $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$, radish is dried from initial mass 60 kg until it gets 5 kg, where the difference equals the amount of water removed. As set temperature is increased, drying time is shortened for both electric heater and heat pump types, however energy efficiency is decreased due to increasing electricity consumption. Moisture extraction rate(MER) of electric heater is 2.58~2.84 kg/h, and for heat pump type 2.56~2.71 kg/h, showing little difference between the two types. Specific moisture extraction rate (SMER) of electric heater is 0.94~0.96 kg/kWh, and for heat pump type 1.72~2.21 kg/kWh. SMER of heat pump type is greater by 0.78~1.25 kg/kWh than the electric heater hot air dryer, which is 1.8~2.3 times better in terms of energy efficiency.

지하수류가 밀폐형 천공 지중 열교환기 성능에 미치는 영향(2) (An Influence of Groundwater Flow on Performance of Closed Borehole Heat Exchangers (Part-2))

  • 한정상;김영식;이주현;이병호;한찬
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권6호
    • /
    • pp.114-127
    • /
    • 2016
  • An increase of groundwater flux in BHE system creates that ground temperature (locT) becomes lower in summer and higher in winter time. In other words, it improves significantly the performance of BHE system. The size of thermal plume made up by advection driven-flow under the balanced energy load is relatively small in contrast to the unbalanced energy load where groundwater flow causes considerable change in the size of thermal plume as well ground temperature. The ground temperatures of the up gradient and down gradient BHEs under conduction only heat transport are same due to no groundwater flow. But a significant difference of the ground temperature is observed between the down gradient and up gradient BHE as a result of groundwater flow-driven thermal interference took placed in BHE field. As many BHEs are designed under the obscure assumption of negligible groundwater flow, failure to account for advection can cause inefficiencies in system design and operation. Therefore including groundwater flow in the design procedure is considered to be essential for thermal and economic sustain ability of the BHE system.

The High Temperature Oxidation Behavior of l0wt%$Gd_2 O_3$- Doped $UO_2$

  • J.H. Yang;K.W. Kang;Kim, K.S.;K.W. Song;Kim, J.H.
    • Nuclear Engineering and Technology
    • /
    • 제33권3호
    • /
    • pp.307-314
    • /
    • 2001
  • The changes of weight gain, structure, morphology and uranium oxidation states in l0wt% G $d_2$ $O_3$-doped U $O_2$ during the oxidation below 475$^{\circ}C$ and heat treatment at 130$0^{\circ}C$ in air were investigated using TGA, XRD, SEM, EPMA and XPS. The room temperature ( $U_{0.86}$G $d_{0.14}$) $O_2$Cubic Phase Converted to highly distorted ( $U_{0.86}$G $d_{0.14}$)$_3$ $O_{8}$ -type sing1e Phase by oxidation at 475 $^{\circ}C$ in air. This oxidized phase was reduced by annealing at 130$0^{\circ}C$ in air. The room temperature XRD pattern of the 130$0^{\circ}C$ annealed powder revealed that ( $U_{0.86}$G $d_{0.14}$)$_3$ $O_{8}$ -type single phase was separated into Gd-depleted $U_3$ $O_{8}$ and Gd-enriched ( $U_{0.7}$G $d_{0.3}$) $O_2$$_{+x}$ type cubic phase. The reduction and phase separation by the high temperature annealing of kinetically metastable and highly deformed ( $U_{0.86}$G $d_{0.14}$)$_3$ $O_{8}$ -type phase are interpreted in terms of cation size difference between G $d^3$$^{+}$ and U according to the oxidation state of U.U.U.U.U.te of U.U.U.U.U.

  • PDF

과학과 교과서에 나타난 열과 열에너지 용어의 정의 및 사용 의미 분석 (An Analysis of the Definition and the Meaning Used for the Terms of Heat and Thermal Energy in the Science Textbooks)

  • 김세림;박종윤
    • 대한화학회지
    • /
    • 제62권3호
    • /
    • pp.214-225
    • /
    • 2018
  • 본 연구에서는 우리나라 과학과 교과서에서 열과 열에너지 용어를 어떻게 정의하고 어떤 의미로 사용하고 있는지, 그리고 과학의 영역별로 이 용어들의 사용 의미에 차이가 있는지 알아보고자 하였다. 이를 위해 2009 개정 교육과정에 의한 초 중 고 과학과 교과서 52권의 내용을 분석하였다. 열 용어의 정의는 중학교 과학(1)과 고등학교 물리 I, II 교과서에서 제시되는데, 대부분의 교과서가 열을 "온도 차이에 의해 이동하는 에너지(유형 I)"로 정의하였고 물리 I 교과서 1종에서만 "온도 차이에 의한 에너지의 이동(유형 II)"으로 정의하였다. 열에너지 용어의 정의는 대체로 중학교 과학(2)와 고등학교 물리 I 교과서에 제시되는데, 물리 I 교과서는 "분자 운동 에너지(유형 III)"로 정의하였지만 과학(2) 교과서에서는 유형 I 또는 "물체의 상태나 온도를 변화시키는 에너지(유형 IV)"로 정의하였다. 교과서 본문 서술에서 열 용어는 주로 유형 I 또는 유형 III의 의미로 사용되었고, 열에너지 용어는 주로 유형 III의 의미로 사용되었으나 고등학교 물리와 화학 교과서에서는 유형 I의 의미로 사용되기도 하여 열과 열에너지 용어를 혼용하고 있었다. 과학의 영역별로 보면 열과 열에너지 용어를 물리와 화학에서는 주로 유형 I과 유형 III의 의미로 사용하였고, 생명과학과 지구과학에서는 주로 유형 III의 의미로 사용하여 영역별로 차이가 있었다.

바닥 복사 난방 시스템의 제어전략에 따른 에너지 사용량 분석 (Energy Saving Potentials of Radiant Floor Heating Systems Based on Control Strategies)

  • 이준우;박철수
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.109-114
    • /
    • 2009
  • The dominant heating system used in Korean residential apartment buildings is a hydronic radiant floor heating system, known as the Ondol system. The most common control strategy applied to this traditional hydronic radiant system is a simple on-off control that intermittently supplies "hot water of a fixed temperature" at a "constant flow rate" to each room. However, the current problems with the aforementioned control are as follows: (1) since the simple on-off control is usually based on a one point measured temperature (a signal from a thermostat installed in a living room) in each dwelling unit, heating energy use for unoccupied rooms as well as a difference in temperatures between spaces (master bedroom, living room, bedroom1, bedroom2) can occur occasionally. (2) the most widely used residential water splitter has static valves, and is thus not able to change the flow rate to each room depending on the space heating load. In other words, the ratio of flow rates to rooms is fixed after construction, resulting in over- or under-heating and an improper use of energy. The aim of this paper is therefore to investigate the differences in the system's performance between control strategies in terms of the flow rate control and sensor location. It is shown that energy savings of control strategies are strongly influenced by occupant schedule.

  • PDF