• Title/Summary/Keyword: Temperature Difference Energy

Search Result 1,101, Processing Time 0.026 seconds

The Influence of Ranque-Hilsch Effect and Joule-Thomson Effect to Energy Separation in a Vortex Tube (보텍스튜브에서 랭퀴-힐쉬효과와 줄-톰슨효과가 에너지분리에 미치는 영향)

  • 유갑종;방창훈;김병하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.703-710
    • /
    • 2000
  • Energy separation characteristic occurring in a counterflow vortex tube was studied experimentally, where air, $C_2$, and R22 were used as working fluids. The experiments were carried out with pressure ratio from 3 to 8 and cold mass fraction(y) from 0.1 to 0.9. As results, Ranque-Hilsch effect showed different results from adiabatic expansion process. Temperature difference in vortex tube outlet was affected by Joule-Thomson effect as well as Ranque-Hilsch effect. The more effective the energy separation was, the more increased the entropy in the cold oulet of vortex tube was.

  • PDF

Generation of Water and Steam Properties for LWR

  • Jun, Byung-Jin;Lee, Chang-Kun;Lee, Ji-Bok;Chang, Jong-Hwa
    • Nuclear Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.180-193
    • /
    • 1980
  • Subroutines to enable fast and accurate generation of water properties-enthalpy, specific volume, viscosity, thermal conductivity and saturation entropy-which are usually basic requirements for nuclear calculation of LWR, have been developed. The sources of data were quoted from “ASME Steam Tables (1967)” and their Revision (1975). It is ensured that the obtained values from this routine fall within 0.2% difference compared with the reference data, in the ranges of temperature and pressure for LWR nuclear calculation.

  • PDF

The Feasibility Analysis of Urban Unused Energy: Focusing on Technology, Institution and Infrastructure (도시지역 미활용 에너지의 타당성에 관한 사례 분석: 기술·제도·인프라를 중심으로)

  • Jin, Sang-Hyeon;Hong, Eun-Jeong
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.17-28
    • /
    • 2013
  • Most governments have an interest in unused energy, because of high oil price and climate change. Particularly, it is very important to urban governments which have less renewable energy than other local governments. So Seoul, the capital of Korea, established a plan for the development of unused energy in 2007. But it has some problems related to the feasibility of this plan. So this paper checked and reviewed the economic feasibility of unused energy development cases in four cities by using three sub elements: technology, infrastructure, institution. As a result, it discovered that these urban governments have technological feasibility because they are located near big river or ocean. And they used the existing infrastructure and received the institutional subsidies from central governments in order to increase the economic feasibility of unused energy development projects. In conclusion, local governments of Korea have to try to seek how they can utilize the existing infrastructure for unused energy development in the situation that there are few institutional supports from the central government.

Hydrogen Supplying System using Metal Hydride (금속 수소화물을 이용한 수소공급시스템)

  • Bae, Sang-Chul;Katsuta, Masafumi
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.13-19
    • /
    • 2007
  • To find out the optimum design of hydrogen storage and supply tank using Metal Hydride (briefly MH) and to make clear the performance characteristics under various conditions are our research purpose. In order to use the low-temperature exhaust heat, $LaNi_{4.7}Al_{0.3}$ which operates under the low pressure of 1 MPa is chosen, and we measure the basic properties, namely density, specific heat, PCT(Pressure-Concentration-Temperature) characteristics, and effective thermal conductivity. Then, a numerical calculation model of hydrogen storage using MH alloy is suggested and this thermal diffusion equation of model is solved by the backward difference method. This calculation results are compared with the experimental results of the systems which installed 1kg MH alloy and, it is found out that our calculation model can well predict the experimental results. By the experimental using MH alloy, it is recognized that the hydrogen flow rate can control by the step adjustment of brine temperature.

  • PDF

Approximate Solution of Absorption Process in an Air-Cooled Vertical Plate Absorber (공냉식 수직평판형 흡수기의 흡수과정에 대한 근사해법)

  • Jeong, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.453-462
    • /
    • 1994
  • An unsteady quasi one-dimensional model of momentum, heat and mass transfer in a falling film of a vertical plate absorber which is cooled by air was developed using the integral method. Energy conservation of the absorber wall is considered in the model. The model can predict absorption rate, film thickness and mean velocity as well as concentration and temperature profiles. Predictions of steady state temperature and concentration profiles for LiBr/water system for constant wall temperature condition are in good agreement with the two-dimensional finite difference method solutions. Effects of operating conditions, such as convective heat transfer coefficient between the cooling air and the absorber wall, cooling air temperature and film thickness at inlet, on absorption rate of water vapor into LiBr/water solution were shown.

  • PDF

Effect of the root-zone temperature grown in the greenhouse on the growth of chives

  • Jung, Kwan-hui;Han, Sangjun
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.222-222
    • /
    • 2017
  • This study aimed to determine an optimal temperature of root zone for the chive cultivation in a greenhouse during the winter season that may raise the possibility of chive (Allium schoenoprasum L.) harvest any time year-round by reducing energy consumption. The maximum and minimum temperatures of root zone were 26.8 and $19.8^{\circ}C$ for the R-Z20, 28.3 and $23.6^{\circ}C$ for the R-Z25 and 22.4 and $14.3^{\circ}C$ for the control. The highest fresh weights of shoot and root, plant height, root length and stem diameter were observed in the R-Z20 treatment. There was no significant difference in the growth between the R-Z25 and control treatment. These results suggest that the optimal temperature of root zone is $20^{\circ}C$ for the chive cultivation in the greenhouse during winter season.

  • PDF

And Experimetal Study for Concrete Strength Prediction by Maturity Concept (성숙도 개념을 이요한 콘크리트의 강도예측을 위한 실험적 연구)

  • 유청호;이주형;김태경;윤경구;박제선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.143-150
    • /
    • 1997
  • The maturity concept was adopted to predict the strength of concrete, which was subjected to same temperature conditions and variable curing conditions. Penetration test and compressive test were conducted to measure the initial and final setting time and the compressible strength of concrete specimen, respectively. Also, the temperature and time were recorded at some intervals of time for calculating the maturity. The initial and final setting were delayed as the w/c ratio increased and curing temperature decreased. The activating energy decreased as the w/c ratio increased. The relationships at the relative strength and the maturity were proposed at different w/c ratio for the same temperature curing condition, and these were applied for the variable curing conditions. The results indicated that the difference between the strength of the proposed and the specimen was big at 1 days's age but quite similar after 3 day's age.

  • PDF

Analysis of Temperature Rise on the Air-Guide's Position of Wind Power Generator (풍력발전기 Air Guide 위치별 온도상승 해석)

  • Han, Chang-Woo;Kim, Hyun-Jae;Kweon, Ki-Yeoung;Lee, Hahk-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.282-285
    • /
    • 2008
  • In this paper, the numerical analysis of the model without air-guide was carried out in wind power generator. From numerical results, the temperature rise was not satisfied for the class F insulation and the non-uniformity of temperature distribution was a wide difference in heating elements. To improve these problems, the air-guide was installed in front of the coil head of non-drive end(NDE). The short distance between coil head and air-guide was more effective than long distance in cooling performance. Compared to that of the preliminary design, it was found that the cooling performance of the modification design was improved about 12%.

  • PDF

Numerical Prediction of Aviation Fuel Temperatures in Unmanned Air Vehicles

  • Baek, Nak-Gon;Lim, Jin-Shik
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.12 no.4
    • /
    • pp.379-384
    • /
    • 2011
  • This paper performs numerical prediction of fuel temperature in the fuel tanks of unmanned air vehicles for both ground static non-operating and in flight transient conditions. The calculation is carried out using a modified Dufort-Frankel scheme. For this calculation, it is assumed that a non-operating vehicle on the ground is subjected to repeating daily cycles of ambient temperature with solar radiation and wind under 1%, with a 20% probability of hot day conditions. The energy conservation equation is used as the governing equation to calculate heat transfer between the fuel tank surface and the ambient environment. Results of the present analysis may be used as the estimated initial values of fuel temperatures in a vehicle's fuel tank for the purpose of analyzing transient fuel temperatures during various flight missions. This research also demonstrates that the fuel temperature of the front tank is higher than that of the rear tank, and that the difference between the two temperatures increases in the later phases of flight due to the consumption of fuel.

The Supply Water Algorithm for a Condensing Gas Boiler Control (콘덴싱가스보일러 제어를 위한 공급수알고리즘)

  • Han, Do-Young;Yoo, Byeong-Kang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.441-448
    • /
    • 2011
  • The energy consumption of a condensing gas boiler may be greatly reduced by the effective operation of the unit. In this study, the supply water algorithm for a condensing gas boiler control was developed by using the fuzzy logic. This includes the supply water set temperature algorithm, and the control algorithms of a gas valve, a blower and a pump. For the set temperature algorithm, the outside air temperature and the return water temperature were used as input variables. The supply water temperature difference and its slope were used as input variables of the gas valve and blower control algorithm. And the supply water temperature and the return water temperature were used as input variables of the pump control algorithm. In order to analyse performances of these algorithms, the dynamic model of a condensing gas boiler was used. The initial start-up test, the supply water set temperature change test, the outside air temperature change test, and the return water temperature change test were performed. Simulation results showed that algorithms developed in this study may be practically applied for the effective control of a condensing gas boiler.