• Title/Summary/Keyword: Temperature Difference Energy

Search Result 1,097, Processing Time 0.024 seconds

Effects of Drying Conditions on the Quality of White Ginseng (백삼건조 조건이 품질에 미치는 영향)

  • 도재호;김상달
    • Journal of Ginseng Research
    • /
    • v.9 no.2
    • /
    • pp.248-255
    • /
    • 1985
  • In order to investigate the optimal drying condition of white ginseng by using bulk air drier(130 x 62 x 65cm), drying curves, diffusion coefficient at various drying temperature, the energy of activation, variation of color intensity and chemical components during drying of white ginseng were studied. Fick's second low of diffusion for diffusion out of spheres was successfully applied to describe the drying of white ginseng. It was found that the diffusion coefficient of water was 2.2x107, 9.0x107 cm2/sec at drying temperature 4$0^{\circ}C$, 55$^{\circ}C$, respectively. An Arrhenius type temperature dependency of moisture diffusivity was found, the energy of activation being 18.8 Kcal/g mol. Color intensity of white ginseng dried at various drying temperature was increased with an increase in drying temperature. The contents of crude protein, reducing sugar and crude saponin during drying of white ginseng were gradually decreased as increasing of drying time. And with the sensory evaluation by multiple comparison difference analysis, the optimal drying temperature of white ginseng was between 45$^{\circ}C$ and 5$0^{\circ}C$.

  • PDF

The Study on Efficiency Improvement of a Thermal Storage Tank for Solar Combined Heating System (태양열원 난방기의 수축열조 효율개선에 관한 연구)

  • Ryu, Nam-Jin;Han, Yu-Ry;Park, Youn-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.43-49
    • /
    • 2007
  • This study is conducted to improve the efficiency of a thermal storage tank. The thermal storage tank was designed to store heat energy that obtained from the solar or the others heat sources. However, it has difficulties in storing heat with nonuniform temperature through the entire tank with respect to the vertical direction, This study is focused on the thermal stratification to improve thermal comfort for the resident in house. To enhance temperature stratification of the tank, a distributor was designed and installed in the middle of the storage tank vertically. The vertically designed distributor could supply the return water with stratified temperature in the storage tank with respect to the height. The water velocity from the distributor hole is the same with the other outlet in the distributor. However, gravity effect on the flow in the storage tank is much higher than that of the velocity effect due to that Froude Number is less than 1. During the heat charging process in the storage tank, temperature maintained with little difference with respect to the height. However the charging process takes long time to get a effective temperature for the heating or hot water supply because of all of water in the storage tank needs to be heated.

Drying characteristics and quality of red ginseng using far-infrared rays

  • Ning, Xiaofeng;Lee, Junsoo;Han, Chungsu
    • Journal of Ginseng Research
    • /
    • v.39 no.4
    • /
    • pp.371-375
    • /
    • 2015
  • Background: The current typical drying methods for red ginseng are sun drying and hot-air drying. The purpose of this study was to investigate drying characteristics of red ginseng by using far-infrared drying. Methods: The far-infrared drying tests on red ginseng were conducted at two drying stages: (1) high temperature for 24 h drying and (2) low temperature drying until the final moisture content was $13{\pm}0.5%$ (wet basis). The high temperature drying stage included three drying chamber temperature conditions of $60^{\circ}C$, $65^{\circ}C$, and $70^{\circ}C$. The low temperature drying stage was conducted at temperatures of $45^{\circ}C$ and $50^{\circ}C$. Drying characteristics were analyzed based on factors such as drying rate, color changes, energy consumption, and saponin content. The results were compared with those of the hot-air and sun drying methods. Results: The results revealed that increases in drying temperature caused a decrease in drying time and energy consumption for far-infrared drying. The saponin content decreased under all drying conditions after drying, the highest value (11.34 mg/g) was observed at drying conditions of $60{\sim}50^{\circ}C$. The sun drying condition showed the lowest color difference value when compared with far-infrared and hot-air drying. Conclusion: The far-infrared drying showed a faster drying rate, higher saponin content, lower color difference value, and a decrease in energy consumption than seen in hot-air drying.

A Study on the Effect of Non-Clean Water Treatment Chemicals for R-134a Turbo-Chiller Condensers (R-134a 터보냉동기 응축기의 무세정 수처리 약품 효과 연구)

  • JUNG, DA-WOON;KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.437-445
    • /
    • 2022
  • This paper presents an experimental study on the main management factors of the condenser contamination such as fouling and corrosion for the R-134a turbo-chiller to save energy, reduce corrosion rates, and reduce maintenance costs through the application of condenser non-cleaning water treatment chemical. The series of experiment is conducted using combining oxidative microbial sterilizers, non-oxidizing microbial sterilizers, and anti-corrosion agents. The leaving temperature difference and corrosion rates for three different combination of chemicals are collected and analyzed. The experimental results show that the cost reduction (4,066,000 Won/year) of the disinfectant (FT-830) can be achieved by adding the oxidative disinfectant (NaOCl) and the non-oxidizing disinfectant (NX-1116). The LTD value is maintained at 1.9℃, and the corrosion rates of copper and carbon steel specimens are 0.07 mpy and 1.61 mpy, respectively.

Experimental Study on the Thermal Storage Efficiency Through Variable Porous Mainfolds in a Test Storage Tank (실험 저장조내의 유입구 형상변화에 따른 열 저장효율에 관한 실험적 연구)

  • Pak, Ee-Tong;Hwang, Sung-Il;Choi, Young-Il
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.37-43
    • /
    • 1989
  • This paper dealt with thermal storage efficiency due to difference ($T_{\infty}-Ti$) between the mean temperature of water in the storage tank [$0.5m{\times}0.5m{\times}1.0m$] and the temperature of water flowing into the tank, flow rate of water flowing into the tank and shape of porous manifold which water flow into the tank through. As results of experiments; (1) When the flow rate was constant and the diameter of porous section decreased by 8mm, 6mm, and 4mm, the thermal storage efficiency increased. (2) When the diameter of porous section was constant and the difference ($T_{\infty}-Ti$) between the mean temperature of water in the storage tank and the temperature of water flowing into the tank increased by -30, -20, -10, 5, 10, 15 ($^{\circ}C$), the thermal storage efficiency increased. (3) When the($T_{\infty}-Ti$) was constant and the flow rate decreased by 0.8, 0.4, 0.25(LPM), the thermal storage efficiency increased. (4) When the shape of porous section was rigid, the thermal storage efficiency was the most effective, and with establishing flexible porous section or mesh, the effective thermal storage efficiency was obtained.

  • PDF

The Condensation Risk Assessment of Vacuum Multi-Layer Glass and Triple Glass using the Temperature Difference Ratio (진공복층 유리와 3중 유리의 결로 위험성 평가)

  • Won, Jong-Seo;Nam, Jung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.11
    • /
    • pp.573-577
    • /
    • 2013
  • An external window directly affects the energy performance of its building. In modern well-insulated buildings, U-values for walls of 0.36 $W/m^2K$ or even lower can be realized. In such buildings, glazing with typical U-value of 2.1 $W/m^2K$ or higher creates thermal weak spots on the facade. The performance of the existing triple glass window has been limited to energy savings and condensation prevention. In this study, the performance of condensation prevention of a vacuum multi-layer glass was analyzed. The final conclusion through mock-up experiments is as follows. The surface temperature of the vacuum multi-layer glass was $2^{\circ}C$ higher, and the temperature difference ratio (TDR) was 0.07 lower, than the corresponding values of the triple glass.

Study on Leak Rate of SCC Degraded Alloy 600 Tubings of PWRs

  • Hwang, Seong Sik;Kim, Joung Soo;Kasza, Ken E.;Park, Jangyul
    • Corrosion Science and Technology
    • /
    • v.3 no.6
    • /
    • pp.233-239
    • /
    • 2004
  • Primary water stress corrosion cracking of steam generator tubings occur on many tubes in pressurized water reactors(PWRs), and they are repaired using sleeves or plugs. In order to develop proper repair criteria, it is necessary to know the leak behavior of the tubes, which have stress corrosion cracks. Crack development tests were carried out on the tubes at room temperature, and leak rate and burst pressure were measured on the degraded tubes at room temperature and a high temperature. No leakage was detected on the tubes where 100 % through wall crack developed, at 1560 psi, which is an operating pressure difference of pressurized water reactors(PWRs). In some tests, leak rates of the tubes increased with time at a constant internal water pressure. A test tube showed a very small amount of leakage at 2700 psi in a high temperature pressure test at $282^{\circ}C$, but it disappeared after the pressure increased slightly. Even cracks are 100 % through wall, they need to open in order to reach a certain amount of leak rate at the operating pressure difference.

Experimental Investigation on the Thermal Performance of a Heat Spreader Module for the CPV Cooling (CPV 냉각용 열분산기 모듈의 열성능에 관한 실험적 연구)

  • Do, Kyu-Hyung;Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.95-102
    • /
    • 2011
  • In this paper, the thermal performance of a heat spreader module for CPV(Concentrating Photovoltaic) cooling is experimentally investigated. In order to evaluate the thermal performance of the heat spreader module which consists of a Metal PCB and an aluminum alloy heat spreader, experiments are conducted with varying the type of the metal PCB, the thickness of the heat spreader, the inclination angle, and the applied heat flux. To validate the experimental data, three dimensional numerical simulations are performed using the commercial simulation tool in the present work. The experimental results are compared with the corresponding numerical results and are in close agreement with the numerical results. From the experimental results, the temperature difference between the maximum temperature and the ambient temperature increases with decreasing the thickness of the heat spreader and with increasing the applied heat flux. Also, it is found that the inclination angle significantly affects the thermal performance of the heat spreader. the maximum temperature difference of the heat spreader with the horizontal orientation is much larger than that with the vertical orientation.

An Experimental Study on Thermal Characteristics between Cooling Fluid and Ice Ball during Charging and Discharging Precesses (빙축 및 냉방열과정중 냉각유체와 Ice Ball사이의 열적 특성에 관한 실험적 연구)

  • 박경원;박이동;황영규;김윤제
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.193-205
    • /
    • 1996
  • This paper deals with experimental study on thermal characteristics that a cooling fluid is affected to ice ball as being measuring the temperature in storage tank and ice ball governing the rate of heat storage. Distributor was taken as inlet geometry factor. flow rate of cooling fluid which was a brine were 2, 4, and 6LPM, and 8, 10, and 12$^{\circ}C$ in the temperature difference for dynamic factors with respect to three ice ball types(103, 96, 76mm). In case of in flowing cooling fluid, since inertia force is suppressed by lower flow rate the amount of heat was transferred to ice ball by heat conduction high because density difference is high. And in case of larger ice ball, a long-term storage was available because reaching time at steady state is relatively long. consequently, smaller ice ball could be suitable to a short-term storage.

  • PDF

FEFLOW를 이용한 천부지열 활용 예측 모델링

  • 심병완;송윤호;김형찬
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.399-402
    • /
    • 2004
  • An aquifer thermal energy storage (ATES) model is simulated by FEFLOW according to the scenario of heat pump operation in two layered confining aquifer. The scenario is consisted of 4 steps: 90 days pumping (west well) and waste water injection (east well: 35 $^{\circ}C$), 90 day s stop, 90days pumping (east well) and waste water injection (west well: 5 $^{\circ}C$), and 95 days stop. The injection of the waste water is limited in the second layer and the first layer is aquitard. The temperature distribution at the surface shows low difference with reference temperature and opposit aspect with that of the second layer because the thermal transition through the first layer is very slow. Even though the simulated thermal transition in the aquifer system have a difference with real ATES system, optimal design and operate system can be developed with field tests and operational experience.

  • PDF