• Title/Summary/Keyword: Tele-monitoring

Search Result 61, Processing Time 0.028 seconds

Implementation of Gateway using TMS in Underwater Acoustic Sensor Networks (Underwater Acoustic Sensor Networks에서 TMS 연동을 위한 Gateway 구현)

  • Kim, Jae-Sub;Nam, Heung-Woo;Kim, Young-Ho;An, Sun-Shin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.20-23
    • /
    • 2012
  • 최근 해양자원의 중요성이 대두됨에 따라, 해양환경을 모니터링 하기 위해 Underwater Acoustic Sensor Networks(UW-ASN)가 활발히 연구되고 있다. UW-ASN 는 해양환경에 대한 데이터를 Sensing, gathering 하고 이를 Monitoring Center로 delivering 하는 Mission 을 수행한다. 이 논문에서는 해양에서 수집한 데이터를 수질 자동 측정망(TMS: Tele Monitoring System)에 전송하기 위해, 음파통신을 통해 수신된 해양 데이터를 수질 자동 측정망의 규격에 맞는 데이터로 변환시키고 CDMA 통신을 통해 가상의 TMS에 전송하는 Gateway 구현을 제안한다.

A Study on the Development of Managing and Control Software for Small Size Cogeneration System (소형 열병합 발전소 관리 및 제어 S/W 개발 연구)

  • Kim, Jin-Il;Cha, Jong-Hwan;Kim, Chang-Tae;Yo, Ko
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.916-918
    • /
    • 1996
  • We have an urgent matter that is lack of energy resource. So we have to accomplish the design of economical energy utility systems and to develop energy facilities with high efficiency. Cogeneration system is one of them. It has high efficiency and can solve unbalanced electricity and heat demand in Summer & Winter concurrently. Recently, to increase the efficiency and stability of the total system, it is applying automatic control and monitoring software to the hardware facilities in industrial control systems. Therefore, these systems has been researched and developed in the advanced countries. It also has been researched and developed in the domestic since '60. But the control and monitoring software in cogeneration system has been hardly developed and has been imported expensive products from the advanced countries. In this study, we have developed the software of operating control, status monitoring, operating data managing and tele-controlling. We have confirmed usefullness of developed software by applying to gas turbine cogeneration system.

  • PDF

Acquisition of Multi-channel Biomedical Signals Based on Internet of Things (사물인터넷 기반의 다중채널 생체신호 측정)

  • Kim, Jeong-Hwan;Jeung, Gyeo-Wun;Lee, Jun-Woo;Kim, Kyeong-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1252-1256
    • /
    • 2016
  • Internet of Things(IoT)-devices are now expanding inter-connecting networking technologies to invent healthcare monitoring system especially for assessing physiological conditions of the chronically-ill patients those with cardiovascular diseases. Hence, IoT system is expected to be utilized for home healthcare by dedicating the original usage of IoT devices to collect the biomedical data such as electrocardiogram(ECG) and photoplethysmography(PPG) signal. The aim of this work is to implement health monitoring system by integrating IoT devices with Raspberry-pi components to measure and analyze ECG and the multi-channel PPG signals. The acquired data and fiducial features from our system can be transmitted to mobile devices via wireless networking technology to support the concept of tele-monitoring services based on IoT devices.

A Study on the Radio Transmission of Bio-Signal for Tele-Medicine (원격진료를 위한 생체신호의 무선전송에 대한 연구)

  • 김정년;곽준혁;최조천;조학현
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.3
    • /
    • pp.379-385
    • /
    • 2002
  • Tele-medicine and emergency medical system are necessary for moving from an accidental point or far distance to a hospital and emergency treatment or home treatment before a hospital. Emergency treatment is extremely important in the case of death before arriving a hospital and deformed of disabled by medical treatment delay. A necessary element for this medical system is the emergency communication system. This system is on preparing for an ability of furnishing patient status to a corresponding health service by monitoring the patient at an ambulance of the accident place. This is the transportation of basic biological information of a patient to a medical center by wireless communication system and the corresponding hospital of medical center examine the patient by monitoring, then they can send emergency medical order to the patient for emergency treatment. The TRS is most efficient way of emergency medical communication system, which is currently used with popularity. In this paper studied simultaneously a way of detecting and transporting bio-logical signals, and monitoring of transporting data with communication of voice in the accident place of ambulance.

Treatment of Hydrochloric acid from Regeneration and Scrubber system of Cold Rolling Mill Plant with Micro-bubble (마이크로버블을 이용한 냉연 산회수설비공정 발생 염화수소 가스 처리)

  • Jung, Yong-Jun;Jung, Jae-Ouk;Kim, Ye-Jin
    • Journal of Wetlands Research
    • /
    • v.17 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • This work has performed to examine the operation status of regeneration and scrubber system of cold rolling mill plant and established the DIWS(Dip Injection Wet Scrubber) system for the removal of hydrochloric acid with micro bubble. When the initial 22.3 ppm of HCl gas was injected into the system, the average exhaust HCl gas was 0.59 ppm with the removal efficiency of 97.3%. Hydrochloric acid was effectively removed by DIWS system. In the long term monitoring for 10 hours by 5 minutes through TMS(Tele Monitoring System), the average exhaust HCl gas was stably kept 0.69 ppm, which was also verified by manual measurement.

Wastewater Treatment Plant Data Analysis Using Neural Network (신경망 분석을 활용한 하수처리장 데이터 분석 기법 연구)

  • Seo, Jeong-sig;Kim, Tae-wook;Lee, Hae-kag;Youn, Jong-ho
    • Journal of Environmental Science International
    • /
    • v.31 no.7
    • /
    • pp.555-567
    • /
    • 2022
  • With the introduction of the tele-monitoring system (TMS) in South Korea, monitoring of the concentration of pollutants discharged from nationwide water quality TMS attachments is possible. In addition, the Ministry of Environment is implementing a smart sewage system program that combines ICT technology with wastewater treatment plants. Thus, many institutions are adopting the automatic operation technique which uses process operation factors and TMS data of sewage treatment plants. As a part of the preliminary study, a multilayer perceptron (MLP) analysis method was applied to TMS data to identify predictability degree. TMS data were designated as independent variables, and each pollutant was considered as an independent variables. To verify the validity of the prediction, root mean square error analysis was conducted. TMS data from two public sewage treatment plants in Chungnam were used. The values of RMSE in SS, T-N, and COD predictions (excluding T-P) in treatment plant A showed an error range of 10%, and in the case of treatment plant B, all items showed an error exceeding 20%. If the total amount of data used MLP analysis increases, the predictability of MLP analysis is expected to increase further.

The effect of the self-measurement frequency levels on SmartCare obesity management (스마트케어 비만관리에서 자가 측정 빈도 수준의 효과)

  • Lee, Chang-Hee;Chang, Byeong-Yun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1972-1980
    • /
    • 2015
  • This study's purpose was to analyze the effect of the SmartCare obesity management pilot project, which was conducted between 09 March 2011 and 03 April 2013 in Korea (South). Of 212 subjects who were enrolled in the study, the final analysis was conducted with 147 subjects who completed their weight self-measurements and SmartCare services until the end of a 6-month service period. The self-measurement group for evaluation was classified into 3 groups (Low, Middle, and High) by evenly dividing the monthly average frequency of measurement for 6 months and the evaluation indices were weight, and BMI (Body Mass Index) transmitted from the SmartCare System. The monthly average weight and BMI were decreased more in the High Group than the Middle Group and Low Group (M5: High>Middle>Low), and they are showing statistically significant differences between groups (p< 0.05). In conclusion, analysis of the weight and BMI improvement effect showed a greater improvement effect when the self-measurement frequency level was higher.

Modeling and Evaluation on the Dispersion of Air Pollutants in the Large Scale Thermal Power Plant (대단위발전소의 대기오염물질 확산에 관한 모델링 및 평가에 관한 연구)

  • Chun, Sang-Ki;Lee, Sung-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.6 no.2
    • /
    • pp.81-92
    • /
    • 1997
  • This paper presents the results from the comparison analysis and evaluation between the air pollutant dispersion modeling results and the observation data in the area within a 10 km radius from the Boryong thermal power plants. The observation data used in this study were the air pollutant concentrations which had been continuously measured from 8 locations around the Boryong power plants by TMS(tele-monitoring system) for 3 months from September to November, 1996. The short-term and long-term predictions were carried out using ISC3 model and LPDM(Lagrangian Panicle Dispersion Model). The results of ISC3 modeling in a short-term showed highly as 0.7 in a correlation coefficient, but in a long-term showed just 0.54. On the other hand, LPDM showed 0.78 in a correlation coefficient for a long-term, but in a short-term showed highly value than the observation concentrations.

  • PDF

The Tele-operated Mobile Robot Kaerot/m2 for Nuclear Power Plants

  • Kim, Chang-Hoi;Seo, Yong-Chil;Cho, Jai-Wan;Kim, Seungho;Park, Young-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.105.4-105
    • /
    • 2002
  • The development of a teleoperated mobile robot, Kaerot/m2, has been described. Kaerot/m2 consists of three subsystems - a 4 wheeled mechanism with the dual reconfigurable crawler arms, a thermal image monitoring system , and an extendable long reach mast. The mechanical design, control system of Kaerot/m2 in terms of remote inspection operation at a high radiation level of the Calandria face environment has been shown. Kaerot/m2 is capable of detecting the degraded locations of the Calandria face in a remote manner.

  • PDF

A Study of Nuclear Power Plant Inspection Tasks Using A Mobile Robot (이동로봇을 이용한 원전 내부 감시점검에 관한 연구)

  • 김창회;서용칠;조재완;최영수;김승호
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.193-196
    • /
    • 2002
  • In this paper, we presents the remote inspection activity with a mobile robot at the calandria face areas of the PHWR (pressurized heavy water reactor) nuclear power plants during full power plant operation.. The tele-operated mobile robot has been developed for this task. A 4 wheeled mechanism with the dual reconfigurable crawler arm has been adopted for the ease access to the high radiation area of calandria face. A specially designed extendable long reach mast attached on the mobile platform and the thermal image monitoring system enable human eyes to look into the calandria face. Application of robot will keep human workers from high radiation exposure and enhance the reliability of nuclear power plants.

  • PDF