• 제목/요약/키워드: Teflon content

검색결과 16건 처리시간 0.04초

인산형 연료전지 성능 특성에 미치는 전극 제조 조건의 영향 (Effects of electrode fabrication conditions on performance characteristics of phosphoric acid fuel cell)

  • 송락현;김창수;신동렬
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.224-229
    • /
    • 1996
  • Performance characteristics of single cell in phosphoric acid fuel cell were studied for various electrode fabrication parameters such as teflon content, electrode structure, thickness of electrocatalyst layer, platinum content and electrode area. The performance of single cell was decided from the measured voltage-current through a load change. The electrode of 40wt.% teflon exhibited high initial performance of single cell, but in the long term operation, the cell performance of 45 wt.% teflon was better. Also the single cell appeared good performance in case of electrodes with duplicate structure, thin electrocatalyst in thickness, more platinum content, and small area. These results of cell performance were discussed as related to the electrolyte flooding, formation of 3 phase boundary area, internal resistance of electrode, and microstructure of electrode.

  • PDF

교류 임피던스법에 의한 인산형 연료전지의 산소전극 특성 연구 (AC Impedance Study of Oxygen Electrode in Phosphoric Acid Fuel Cell)

  • 송락현;김창수;신동열
    • 전기화학회지
    • /
    • 제3권4호
    • /
    • pp.191-195
    • /
    • 2000
  • 교류 임피던스법을 사용하여 온도, 부하전위 및 전극내 테프론 함량에 따른 인산형 연료전지의 산소전극 반응의 특성을 연구하였다. $105wt.\%$ 인산에서 산소 전극의 임피던스 거동은 전극 계면 저항, 전극 계면 캐패스턴스 및 전해질 저항으로 이루어진 간단히 회로로 특징지어지고, 이것으로부터 구한 인산의 전기전도도는 $130\~190^{\circ}C$의 온도범위에서 0.31-0.47 S/cm 로 나타났다. 부하전위와 온도가 증가함에 따라 산소극의 계면저항은 감소하였으나 산소극의 계면 캐패스턴스는 증가하였으며, 이것은 산소극의 반응속도와 전극의 계면 임피던스가 직접적인 관계를 가진다는 것을 의미한다. 테프론 함량에 따른 인산형 연료전지 단전지의 성능을 조사하여 임피던스 측정결과와 비교하였으며, $40wt.\%$에서 최대 성능을 나타내었고, 이것은 산소극의 계면 임피던스 값이 최적 상태를 나타내었기 때문인 것으로 판단되며, 이러한 결과들이 전극의 3상계면 상태와 연관지어 토의되었다.

휴대용 고농도 과산화수소 측정 전극의 개발 (Development of Portable-Type Electrode for the Determination of Highly Concentrated Hydrogen Peroxide)

  • 이진서;최강;김상진;차근식;남학현;노경래;김진두
    • 분석과학
    • /
    • 제12권2호
    • /
    • pp.125-129
    • /
    • 1999
  • 고농도의 과산화수소(10-75%)를 생산현장에서 손쉽게 측정할 수 있는 전극 센서 시스템을 연구하였다. Teflon 전극체는 휴대에 간편하도록 길이 10 cm, 지금 1.5 cm의 봉 형태로 제작하였고, 작업 극으로는 직경 3 mm의 glassy carbon을, 보조전극으로는 내경 5 mm, 외경 9 mm의 흑연을 전극물질로 사용하였다. 과산화수소 산화전위는 0.8 V의 전위를 걸어주었다. 공장에서 생산된 고농도의 과산화수소를 일정 이온강도의 전해질 용액으로 희석해 10% 이하의 농도가 되도록 하면 과산화수소에 첨가된 안정제의 방해작용과 과산화수소의 산화작용으로 인한 전극표면의 변성을 최소화할 수 있었고, 손쉽게 정량적인 측정을 할 수 있었다. 또한 과산화수소 투과막(teflon membrane${\leq}100{\mu}m$)을 입힌 전극을 이용하면 고농도의 과산화수소를 희석하지 않고 재현성 있게 정량할 수 있었다. 반면 투과막을 이용하는 방법을 내부전해질을 자주 교환해야 하는 단점이 있었다.

  • PDF

허니컴방식 UV 살균기를 이용한 살균 탁주의 저장 중 품질변화 (Changes in Quality of UV Sterilized Takju during Storage by Honeycomb Type-UV Sterilizer)

  • 이장운;정진주;최은주;강성태
    • 한국식품과학회지
    • /
    • 제41권6호
    • /
    • pp.652-656
    • /
    • 2009
  • 탁주를 효과적으로 살균하기 위해서 110가닥의 테프론 튜브와 9개의 자외선(UV) 램프(1,335W)로 구성된 허니컴방식의 UV 살균기를 제작하고 탁주를 순환시켜 살균하여 미생물 살균효과 및 저장 중의 품질변화를 평가하였다. 허니컴방식의 UV 살균기에서 유속 2 L/min에서 4분 동안 탁주를 순환시킨 조건은, 일반세균 및 진균을 2-3 log cycle 감소시키면서 관능적으로 양호한 품질을 얻을 수 있는 최적의 살균조건으로 판단되었다. 이 조건에서 살균 처리한 탁주를 $30^{\circ}C$에서 8일간 저장하면서 pH, 아미노태질소 함량, 환원당 함량, 산도, 그리고 일반세균수 및 진균수의 변화를 측정하였다. pH, 산도, 아미노태 질소 함량은 저장 중에 생탁주와 UV 살균탁주에서 모두 증가하는 경향을 나타낸 반면 환원당 함량은 감소하는 경향을 나타내었다. 또한 생탁주와 UV살균탁주의 L, a, b 값은 저장 중에 매우 유사한 경향을 나타내었다. 저장 중에 UV 살균탁주의 진균은 생육이 억제되었으며 일반세균은 저장 4일째에 생탁주 수준에 도달하였다.

자외선 살균이 청징 탁주의 저장 중 품질에 미치는 효과 (Effect of UV Sterilization on Quality of Centrifuged Takju during Storage)

  • 최은주;정진주;이장운;강성태
    • 한국식품영양과학회지
    • /
    • 제39권3호
    • /
    • pp.461-466
    • /
    • 2010
  • 총 110 가닥의 테플론 튜브와 9개의 자외선(UV)램프(총 1395 W)로 구성된 허니컴 방식의 UV살균기를 제작하고 원심분리를 통해 생탁주의 고형분을 제거시킨 청징탁주(CT)를 순환시켜 살균하였다. 미생물살균과 관능적 품질 등을 고려한 전반적인 품질평가 결과, 최적의 살균조건은 2 L/min의 유속에서 1.5분간 살균하는 것이 최적의 조건으로 확인되었다. 이러한 살균조건에서 약 일반세균수와 진균수를 5~6 log cycle 감소시킬 수 있었다. 자외선으로 살균된 청징탁주는 $30^{\circ}C$에서 8일 동안 저장하며 pH, 아미노태질소 함량, 산도, 환원당 함량, 일반세균수 및 진균수 등의 품질 평가를 수행하였다. 자외선으로 살균된 청징탁주의 진균수는 저장 4일 후에 이르러서야 $10^8\;CFU/mL$에 도달하였고 일반세균수는 6일 후에 이르러서야 $10^8\;CFU/mL$에 도달하여 생육이 억제되었음을 확인할 수 있었다. 또한 환원당 함량을 제외하고는 자외선으로 살균된 청징탁주의 pH, 아미노태질소 함량, 산도는 저장 중에 변화를 나타내지 아니하였다. 또한 저장 기간 동안 청징탁주와 자외선으로 살균된 청징탁주 간에는 L, a 및 b 값 간에 차이를 보이지 않아 색도의 변화에는 자외선 살균이 영향을 미치지 않은 것으로 확인되었다.

치과용 가시광선중합형 복합레진의 잔류단량체 정량분석에 관한 연구 (QUANTITATIVE ANALYSIS OF RESIDUAL MONOMERS IN VISIBLE LIGHT-CURED RESINS)

  • 최경규;민병순
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.181-190
    • /
    • 1992
  • The purpose of this study was to estimate the contents of the residual monomers, such as Bis-GMA and TEGDMA. In this study, materials used were six kinds of anterior and posterior visible light-cured resins. Resins were placed in disk-shaped Teflon mold (8.5mm in diameter, 2.0mm in thickness), and cured for 20 seconds with visible light source attached wide diameter lightguide. The specimens were immersed in 10ml ethanol and stored for 5 days at $37^{\circ}C$. The concentration of residual monomers in eluate solution was analysed by HPLC, and the following results are obtained. 1. The residual Bis-GMA and TEGDMA were detected in all materials used, and the ranges of quantity of the residual Bis-GMA was 0.101-1.236 wt% and that of TEGDMA was 0.230-5.794 wt%.2. The contents of residual TEGDMA was detected higher than that of residual Bis-GMA (P < 0.01). 3. The content of residual monomers was detected to be highest in Bis-Fil M as microfilled type. 4. In most of the materials used, there was no significant difference in the contents of residual monomers between anterior and posterior light-cured resins.

  • PDF

The polymerization efficiency of a bulk-fill composite based on matrix-modification technology

  • Elshazly, Tarek M.;Bourauel, Christoph;Aboushelib, Moustafa N.;Sherief, Dalia I.;El-Korashy, Dalia I.
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.32.1-32.12
    • /
    • 2020
  • Objectives: To evaluate the polymerization efficiency of a matrix-modified bulk-fill composite, and compare it to a conventional composite which has a similar filler system. The degree of conversion (DC%) and monomer elution were measured over different storage periods. Additionally, fillers' content was examined. Materials and Methods: Cylindrical specimens were prepared, in bulk and incrementally, from Filtek Bulk Fill (B) and Filtek Supreme XTE (S) composites using a Teflon mold, for each test (n = 6). Using attenuated total reflection method of Fourier transformation infrared spectroscopy, DC% was measured after 24 hours, 7 days, and 30 days. Using high-performance liquid chromatography, elution of hydroxyethyl methacrylate, triethylene glycol dimethacrylate, urethane dimethacrylate, and bisphenol-A glycidyl dimethacrylate was measured after 24 hours, 7 days and 30 days. Filler content was examined by scanning electron microscopy (SEM). Data were analyzed using 2-way mixed-model analysis of variance (α = 0.05). Results: There was no significant difference in DC% over different storage periods between B-bulk and S-incremental. Higher monomer elution was detected significantly from S than B. The elution quantity and rate varied significantly over storage periods and between different monomers. SEM images showed differences in fillers' sizes and agglomeration between both materials. Conclusions: Matrix-modified bulk-fill composites could be packed and cured in bulk with polymerization efficiency similar to conventional composites.

직접 메탄올 연료전지를 위한 술폰화 폴리스티렌/테플론 복합막 제조 및 특성연구 (Sulfonated Polystyrene/PTFE Composite Membranes for Direct Methanol Fuel Cell)

  • 김정훈;신정필;박인준;이수복;서동학
    • 멤브레인
    • /
    • 제14권2호
    • /
    • pp.173-184
    • /
    • 2004
  • 술폰화 폴리스티렌/테플론(Polystyrene/Teflon, 이하 'PS/PTFE'로 칭함) 복합막을 제조하여 직접 메탄을 연료전지용 막에 관한 특성을 조사하였다. 복합막은 다음과 같이 제조되었다. 먼저 다공성 테플론 필름에 styrene 단량체와 가교제인 diviny benzene (이하 'DVB'로 칭함)의 비율을 달리하면서, 개시제 2,2'-azobis(isobutylonitlie) (AIBN)와 함께 함침시킨 후 열을 가해 폴리스티렌/테플론 복합막을 제조하였다. 그 후 술폰화제인 chlorosulfonic acid와 1,2-dichloroethane혼합용액을 사용하여 술폰화된 복합막을 제조하였다. 제조된 복합막의 술폰화 전과 후의 물리화학적 구조는 ATR-FTIR, SEM, THF 및 물에 대한 함유율, 이들의 이온교환량을 통하여 확인하였다. 이러한 결과로부터 스티렌/디비닐벤젠의 비율에 따라 복합막이 성공적으로 제조되었음을 확인하였다. 또한 가교제인 디비닐벤젠의 함량이 높을수록, 가교도가 증가하여 물 및 THF에 대한 함유율이 감소하였다. 이온전도도, 메탄올투과도를 조사한 결과, 디비닐벤젠의 함량 증가와 함께 이온전도도는 감소하였으며, 메탄올 투과도가 감소하였다. 제조된 술폰화된 폴리스티렌/테플론 복합막은 Nafion$^{(R)}$ 과 비교할 만한 높은 이온 전도도(0.11∼0.08 S/cm, $25^{\circ}C$)를 보이면서 훨씬 낮은 메탄올 투과도($6.6{\times}10^{-7}∼1.3{\timas}10^{-7}$ $\textrm{cm}^2$/s)를 나타내었다. 이러한 결과들은 본 연구에서 개발된 복합막이 직접 메탄올 연료전지에 적용될 가능성이 높다는 것을 보여준다.

정전용량 수분센서의 배지 함수량 정량화 (Quantification of Rockwool Substrate Water Content using a Capacitive Water Sensor)

  • 백정현;박주성;이호진;안진희;최은영
    • 생물환경조절학회지
    • /
    • 제30권1호
    • /
    • pp.27-36
    • /
    • 2021
  • 정전용량 수분측정 센서는 수경용 배지 양쪽에 구리 및 테플론으로 절연된 전극판(30cm×10cm)을 부착하여 배지의 넓은 부분에 걸쳐 측정하도록 개발되었다. 본 연구는 콘덴서형 정전용량 센서로부터 출력되는 정전용량 값을 배지 함수량으로 변환하는 것이다. 정량화 실험은 양액을 공급하면서 배지 물무게와 정전용량 변화를 측정하고 그 값을 비교하는 방식으로 수행되었다. 배지 함수량과 정전용량은 본 연구를 위해 특별히 개발된 소프트웨어와 함께 센서와 로드셀을 사용하여 20~30초마다 측정되었다. 상용 curve-fitting 프로그램을 이용하여 배지 함수량과 정전용량을 변수로 정전용량 값으로 배지 함수량을 추정하였다. 공급하는 물의 양이 증가하면 정전용량도 증가하는 경향을 보였다. 배지 내 물무게에 따른 정전용량에 대한 변동계수(coefficient of variation, cv)는 배지 내 물무게가 1.0kg 수준에서 다른 무게에 비해 높아 함수량 보정은 물무게를 1.7~6.0kg 수준에서 수행하였다. 정전용량과 물무게 사이의 상관 계수는 0.996이었고 보정식에 의해 정전용량으로 추정된 함수량은 로드셀로 측정한 배지 함수량과 비교하였다.