• Title/Summary/Keyword: Teflon

Search Result 527, Processing Time 0.026 seconds

Asymmetric 45$^{\circ}$ Schiffman Phase Shifter (PS) (비대칭 45$^{\circ}$ Schiffman 위상 천이기)

  • 채동규;임문혁;김동현;윤기완
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.97-99
    • /
    • 2003
  • Novel asymmetric 45$^{\circ}$ Schiffman phase shifter having l-coupling for 2.3GHz applications is presented along with measurement results. The proposed phase shifter with a Teflon substrate is fabricated in a smaller area and cost-effective way as compared to the conventional Schiffman phase shifter. In addition, the characteristics of the fabricated phase shifter is extracted and compared. The proposed phase shifter seems useful particularly for the future 2.3GHz wireless applications.

  • PDF

A Study on Dielectric Properties of Printed Circuit Board(PCB) Materials with Variation of Frequency and Temperature using Coaxial Air Line Probe (동축선로 프로브를 이용한 프린트 배선 회로용 기판 재료의 주파수 및 온도 변화에 따른 유전특성 연구)

  • 박종성;김종헌
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.187-190
    • /
    • 1998
  • In this paper a probe for the' measurement of dielectric properties of dielectric sheet materials is designed and implemented as a coaxial air line type. Using the broadband impedance method with this measurement probe the dielectric constant and loss tangent of the glass-epoxy and teflon are determined in the frequency range of 0.1 - l.O[GHz] with the temperature variation from $25[^{\circ}C]$ up to $65[^{\circ}C]$. A measured relative dielectric constant of the glass-epoxy is 4.42 and a loss tangents is 0.019 relatively, and the relative dielectric constants of teflon is 2.17 and a loss tangents is 0.002 relatively

  • PDF

A Successful Prosthetic Correction of Long Narrow Segment Coarctation of the Aorta: Report of A Case (대동맥축착에 대한 Teflon 인조혈관 이식술 치험예)

  • 김근호
    • Journal of Chest Surgery
    • /
    • v.10 no.1
    • /
    • pp.90-97
    • /
    • 1977
  • This is a report of a. case in which a long narrow segment coarctation of the aorta was successfully corrected with Teflon graft. The patient was 30 year old man with hypertensive symptoms that occurred 7 years prior to operation. Blood pressure measured 230/110 mmHg in the arms and 110/80 mmHg in the legs. Pulses were strongly tensive in radial artery, but very weak in femoral artery and even absent in dorsal pedis artery. Final preoperative diagnosis was made by aortography which showed a long narrow segment between aortic arch and descending thoracic aorta and highly developed collateral circulations. A long hypoplastic narrow segment was located proximal to the ligament arteriosus, and diaphragmatic stenosis of the aorta was located just distal to the ligamentum arteriosus. After prosthetic correction of the coarctation of the aorta, blood pressure were measured 130/ 80 mmHg in the arms and 150/100 mmHg in the legs. Peripheral pulses were palpated normally, and the postoperative course was uneventful.

  • PDF

Evaporation Cooling of Single Droplet on a Heated Solid Surface (가열된 고체표면에 부착된 단일 액적의 증발냉각)

  • Yu, Gap-Jong;Bang, Chang-Hun;Kim, Jeong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.845-852
    • /
    • 2001
  • The characteristics of evaporation cooling of single droplet on a heated surface were studied experimentally. The two kinds of heater modules were tested to measure cooling characteristics of metal surface (high conductivity) and Teflon surface (low-energy surface, low conductivity). The results showed that time averaged heat flux during droplet evaporation increased exponentially with initial surface temperatures of brass, copper and steel. The heat flux and evaporation time did not varied with metal conductivities. However, the temperature drop after the deposition of droplet was larger on Teflon than on the metals. Thus, the correlation of interface temperature between liquid droplet and metal surface was proposed as a function of the initial surface temperature of heating materials, which could be applied to both metal and non-metal ones.

Development and Nonlinear Dynamic Model of Sliding Wall Damper To Retrofit of R/C Frame Structures (R/C 골조구조물 내진보강을 위한 슬라이딩 벽식감쇠기의 개발 및 비선형 동적해석모델)

  • 조창근;박문호;장준호;김기욱;정인규
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.411-418
    • /
    • 2003
  • In order to retrofit R/C frame structures, a newly proposed Teflon sliding wall damper, consisted of Teflon slider and R/C shear wall, is evaluated by the dynamic analysis model of inelastic frame structures. From analysis results, it is shown that the damper reduces the time-history responses, the maximum story drifts, and the damage of R/C member. By control of damper pressures, especially, the damper can be easily applicable not only to capacity design according to required responses and member damages but also to active damper with actively controlling devices.

  • PDF

Microwave Hydrothermal Sythesis of PbTiO$_3$ and PMN Ceramic Powders (마이크로파 수열법에 의한 PbTiO$_3$ PMN 세라믹분말의 합성)

  • Bai, Kang
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.5
    • /
    • pp.465-471
    • /
    • 1998
  • Lead titanate(PT) and lead magnesium niobate(PMN) ceramic powders were prepared by microwave hy-drothermal method using teflon bomb. Raw materials were Pb(NO3)2 and TiO2 for lead titanate and Pb(NO3)2 Nb2O5 and Mg(NO)3.6H2O for PMN with NaOH as mineralizer in both cases. in lead titanate synthsis rate of microwave hydrothermal method was faster three times than one f conventional hydrothermal methods In lead magnesium niobate synthsis the mixture of perovskite and pyrochlore phases was obtained by single step technique and the PMN was not obtained by double step technique due to low temperature limitation of teflon bomb.

  • PDF

A Study on the Charging and discharging current of corona charged Teflon-FEP film (코로나 대전된 Teflon-FEP의 충.방전 전류 특성에 관한 연구)

  • Cheong, Ki-Seok;Lee, Seung-Woo;Park, Kwang-Hyun;Lee, Deok-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1988.05a
    • /
    • pp.60-62
    • /
    • 1988
  • In this study, the characteristic of charging current which flows into the polymer by applying the corona discharge carriers on the polymer surface was measured, so as to investigate the phenomenon of charge injection and movement if injected charge on polymer. Also. the characteristics of discharge current which flows by shorting both sides of corona charged polymers were measured. Experimental results are as follows; The amount of charges injected by corona discharge vary according to the state of surface and the type of carriers, and then the charging current varies according to the properties of injected carriers.

  • PDF

A Study on the press warm forming of stainless-aluminum clad sheet metals (스테인레스-알루미늄 클래드 강판재의 프레스 온간 성형 연구)

  • 류호연;박건규;김종호
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1998.06b
    • /
    • pp.8-18
    • /
    • 1998
  • The effect of press warm forming in cylindrical deep drawing of stainless-aluminum clad sheet metals are examined . The temperature of die and blank holder is varied from room temperature to 20$0^{\circ}C$, while the punch is kept cooled during test to increase the fracture strength of workpiece on the punch corner area. Test materials chosen for experiments are STS304-Al050-STS304, STS304-A1050-STS430-, STS304 and Al050 metals and teflon film as a lubricant is used on both sides of a workpiece. The limit drawing ration as well as quality of drawn cups (distribution of thickness and hardness)are investigated and discussed.

  • PDF

Thermal Conductivity Measurement of Insulation Material for Superconducting Application

  • Chol, Y.S.;Kim, D.L.;Shin, D.W.;Hwang, S.D.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.2
    • /
    • pp.29-32
    • /
    • 2011
  • The thermal properties of insulation material are essential to develop a high-temperature superconducting (HTS) power cable to be operated at around liquid nitrogen temperature. Unlike metallic materials, nonmetallic materials have a high thermal resistance; therefore special attention needs to be paid to estimate heat flow correctly. Thus, we have developed a precise instrument for measuring the thermal conductivity of insulating materials over a temperature range from 40 K to near room temperature using a cryocooler. Firstly, the measurement of thermal conductivity for Teflon is carried out for accuracy confirmation. For a supplied heat flux, the temperature difference between warm and cold side is measured in steady state, from which the thermal conductivity of Teflon is calculated and compared with published result of NIST. In addition, the apparent thermal conductivity of Polypropylene laminated paper (PPLP) is presented and its temperature dependency is discussed.

Ethanol Productivity in a Hollow Fiber Membrane Module Using High Density of Saccharomyces cerevisiae (실관반응기 내의 Saccharomyces cerevisiae의 고농도 배양을 이용한 에탄올 생산성)

  • 장호남;양지원박용석정봉현
    • KSBB Journal
    • /
    • v.7 no.1
    • /
    • pp.67-71
    • /
    • 1992
  • We studied a continuous production of ethanol by Saccharomyces cerevisiae in a hollow fiber membrane bioreactor which consisted of 50 polypropylene fibers and 3 teflon fibers. The produced $CO_2$ was removed through the teflon fibers and excess biomass was removed through the shell side. We obtained the cell and ethanol concentrations of 266g/L and 205g/L based on the shell-side volume. A nitrogen deficient medium resulted in too low an ethanol productivity to be applied to a practical process.

  • PDF