• Title/Summary/Keyword: Technology standards

Search Result 5,868, Processing Time 0.034 seconds

Comparison of Methane Production in Korean Native Cattle (Hanwoo) Fed Different Grain Sources (곡류 사료원별 육성기 한우 장내발효에 의한 메탄가스 배출량 비교)

  • Seol, Yong-Joo;Kim, Kyoung-Hoon;Baek, Youl-Chang;Lee, Sang-Cheol;Ok, Ji-Woun;Lee, Kang-Yeon;Hong, Seong-Koo;Park, Kyu-Hyun;Choi, Chang-Weon;Lee, Sung-Sil;Oh, Young-Kyoon
    • Journal of Animal Science and Technology
    • /
    • v.53 no.2
    • /
    • pp.161-169
    • /
    • 2011
  • Methane production during anaerobic fermentation in the rumen represents an energy loss to the host animal and induces emissions of greenhouse gases in the environment. Our study focused on comparison in methane production from growing Korean native steers fed different grain sources. Six Hanwoo steers (BW = $180.6{\pm}3.1$ kg) were fed, on a DM basis (TDN 2.80 kg), 40% timothy and 60% barley concentrate (Barley) or corn concentrate (Corn), respectively, based on the Korean Feeding Standards. Each period lasted 18 days including a 14-day adaptation and a 4-day measuring times. The steers were in the head hood chamber system (one cattle per chamber) during each measuring time to measure heat and methane production per day. Different grain sources did not affect digestibilities of dry matter, crude protein, crude fiber, crude fat, NDF, ADF and nitrogen-free extract. The mean methane concentrations per day were 202.0 and 177.1 ppm for Barley and Corn, respectively. Methane emission averaged 86.8 and 77.7 g/day for Barley and Corn, respectively. Methane emission factor by maintenance energy requirement for the growing steers fed barley based concentrate was higher than the steers fed corn based concentrate (Barley vs. Corn, 31.7 kg $CH_4\;head^{-1}\;yr^{-1}$ vs. 28.4 kg $CH_4\;head^{-1}\;yr^{-1}$). Thus, methane conversion rate was 0.065 (6.5%) and 0.055 (5.5%) for Barley and Corn, respectively.

Determination of Maintenance Energy Requirements for Growing Hanwoo Steers (육성기 거세한우의 유지에너지 요구량 결정에 관한 연구)

  • Seol, Yong-Joo;Kim, Kyoung-Hoon;Baek, Youl-Chang;Lee, Sang-Cheol;Ok, Ji-Un;Lee, Kang-Yeon;Hong, Seong-Koo;Jang, Sun-Sik;Choi, Chang-Weon;Song, Man-Kang;Lee, Sung-Sil;Oh, Young-Kyoon
    • Journal of Animal Science and Technology
    • /
    • v.53 no.2
    • /
    • pp.155-160
    • /
    • 2011
  • Present experiment was carried out to determine maintenance energy requirements for growing Hanwoo steers. Six Hanwoo steers (BW = $180.6{\pm}3.1$ kg) were used in two 3 ${\times}$ 3 latin square design with three different energy intake levels; TDN 1.70 kg (Low), 2.05 kg (Medium), 2.80 kg (High), respectively, based on the Korean Feeding Standards. Each period lasted 18 days including a 14-day adaptation and a 4-day measuring period. The steers were in the head hood chamber system (one cattle per chamber) during each measuring time to measure heat and methane production for 1 day. Dry matter intake was 2,058, 3,256 and 3,881 g/day for Low, Medium and High TDN, respectively. Increase in energy intake did not affect digestibilities of dry matter, crude protein, crude fiber, crude fat, NDF, ADF and nitrogen-free extract. Gross energy intake averaged 180.21, 292.74 and 337.15 kcal/$BW^{0.75}$ for Low, Medium and High TDN, respectively. Energy loss was 28.7% in feces and 2.1% in urine of gross energy intake. Further, energy loss from methane produced during rumen fermentation was 6~8.3%, while body heat loss averaged 34~60%. Intercept of regression equation between ME intake and retained energy indicated that the energy requirement was 109.84 kcal ME/$BW^{0.75}$.

Analysis of Daily Milking Flow in Holstein Dairy Cow Using the LactoCorder (전자식유량계를 활용한 홀스타인 젖소의 비유형질 분석)

  • Cho, Kwang-Hyun;Choi, Jun-Pyo;You, Byung-Wha;Lee, Deuk-Hwan;Kong, Hong-Sik;Park, Kyung-Do;Lee, Hak-Kyo
    • Journal of Animal Science and Technology
    • /
    • v.51 no.4
    • /
    • pp.265-272
    • /
    • 2009
  • A total of 486 milk records were collected from 16 diary farms in Imsil-gun, Jeollabuk-do. Results obtained were as follows: The average 3MG (amount of milk within the first three minute) was 7.44 kg and 55% of total milk yield was produced within 3 min. The average of SPL (% of foam in milk) was 33.93% and the average of MNG (strip yield) was 0.14 kg, which was less than 1% of total milk yield. The averages of HMF (highest milk flow), HMG (maximum milk flow rate in one minute) and DMHG (average milk flow in the main milking phase) were 3.03 kg/min, 2.94 kg/min and 2.05 kg/min, respectively and the average milking speed in Imsil-gun was slower than other regions. The average of tS500(time to reach 0.5 kg/min at beginning) was 0.23min (about 14 seconds) and that of tMGG (duration of the total milking) was 7.75min. The average tMBG (duration of the dry milking phase) was 0.58 min (35 seconds) and that of tMNG (duration of the stripping phase) was 0.42min (14 seconds). The averages of ELHMF (electrical conductivity at highest milk flow) and ELAP (beginning peak level of the electrical conductivity) were 6.81 mS/cm and 7.58 mS/cm, respectively. The average of ELMAX (maximum electrical conductivity) was 7.48 mS/cm and that of ELAD (beginning peak difference of the electrical conductivity) was 0.61 mS/cm. While the total milk yields for DMHG, tMHG (duration of the main milking phase), tPL (duration of the plateau phase), tAB (duration of the descending phase) and tMGG were positively correlated (0.35~0.54), those for tMBG and SPL were negatively correlated (-0.11 and -0.27). As the DMHG increased, tMHG, tPL, tAB, tMGG and SPL decreased. While the cows with higher electrical conductivity at the beginning of milking had less somatic cell counts, cows with higher electrical conductivity after the peak of milk yield had more somatic cell counts. The results of this experiment indicated that through milking based on milking and lactating standards and the regular checking of milking status, the qualities of milk and milk yields could be improved.

Study on Clinical Dental Hygiene in Korea Based on Analysis of Clinical Dental Hygiene Curriculum of Fones School in the United States (미국 폰즈스쿨의 임상치위생학 교육과정 분석을 통한 국내 임상치위생학 교육과정에 관한 고찰)

  • Choi, Yong-Keum;Lim, Keun-Ok;Han, Yang-Keum;Bae, Soo-Myoung;Shin, Bo-Mi;Ahn, Se-Youn;Jeon, Hyun-Sun;Kim, Jin;Jang, Sun-Ok;Kim, Hye-Jin;Park, Ji-Eun;Lim, Hee Jung;Jang, Yun-Jung;Jung, Jin-Ah;Lee, Hyo-Jin
    • Journal of dental hygiene science
    • /
    • v.17 no.2
    • /
    • pp.123-133
    • /
    • 2017
  • The aim of this study was to analyze in depth the standardized Clinical dental hygiene curriculum of the Fones School in the United States. We investigated the clinical dental hygiene curriculum in 2015~2016 including title, credit, hours, contents, goals, competencies, and evaluation. We obtained the course syllabus and data related to each subject, for each grade, from the professors and students at the university. The goals and competencies, of the clinical dental hygiene program, which were based on the goals of the Fones School and the mission of the University of Bridgeport, were developed in accordance with the dental hygienist practice standards proposed by the American Dental Hygienists Association. The curriculum consisted of theory to teach proper dental hygiene care procedures and incorporated practical exercises that modeled an actual clinical setting. The students had to document the procedures performed for each client/patient and improve their clinical competency through discussion with the professors. Dental hygiene care should be provided for children, adolescents, adults, elderly, and patients, which includes patients with moderate or severe periodontal status. Students were evaluated by a paper test or case study presentation and their clinical evaluation was based on their clinical competency. In particular, professors evaluated students on a rotational basis, so they could evaluate the level of achievement of clinical competency of all students and find ways to improve any weaknesses. Therefore, the current study suggested that clinical dental hygiene program in Korea could be improved if based on the curriculum of Fones School in the United States.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Distribution of foodborne pathogens in red pepper and environment (고추와 재배환경의 식품매개 병원균 분포)

  • Jung, Jieun;Seo, Seung-Mi;Yang, SuIn;Jin, Hyeon-Suk;Jung, Kyu-Seok;Roh, Eunjung;Jeong, Myeong-In;Ryu, Jae-Gee;Ryu, Kyoung-Yul;Oh, Kwang Kyo
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.6
    • /
    • pp.799-808
    • /
    • 2021
  • This study was performed to investigate the extent of microbial contamination, the presence of enterotoxin genes, and the antibiotic susceptibility of Bacillus cereus in 58 red pepper plants and 43 environmental samples (soil, irrigation water, and gloves) associated with the plant cultivation. The detected counts of total aerobic bacteria, coliform bacteria, Escherichia coli, Bacillus cereus, and Staphylococcus aureus were lower in these samples, as compared to the regulations of standards for foods; moreover, pathogens, such as E. coli, E. coli O157:H7, Listeria monocytogenes, and Salmonella spp., were not detected. Genes encoding hemolysin BL enterotoxins (hblA, hblC, and hblD) as well as non-hemolytic enterotoxins (nheA, nheB, and nheC) were detected in 23 B. cereus specimens that were isolated from the test samples and had β-hemolytic activity. Interestingly, B. cereus is resistant to β-lactam and susceptible to non-β-lactam antibiotics. However, in this case, the isolated B. cereus specimens exhibited a shift from resistant to intermediate in response to cefotaxime and from susceptible to intermediate in case of rifampin, trimethoprim-sulfamethoxazole, vancomycin, clindamycin, and erythromycin. Therefore, the levels of B. cereus should be monitored to detect changes in antibiotic susceptibility and guarantee their safety.

A Study on Setup for Preliminary Decision Criterion of Continuum Rock Mass Slope with Fair to Good Rating (양호한 연속체 암반사면의 예비 판정기준 설정 연구)

  • Kim, Hyung-Min;Lee, Su-gon;Lee, Byok-Kyu;Woo, Jae-Gyung
    • The Journal of Engineering Geology
    • /
    • v.29 no.2
    • /
    • pp.85-97
    • /
    • 2019
  • It can be observed that steep slopes ($65^{\circ}$ to $80^{\circ}$) consist of rock masses were kept stable for a long time. In rock-mass slopes with similar ground condition, steeper slopes than 1 : 0.5 ($63^{\circ}$) may be applied if the discontinuities of rock-mass slope are distributed in a direction favorable to the stability of the slope. In making a decision the angle of the slope, if the preliminary rock mass conditions applicable to steep slope are quantitatively setup, they may be used as guidance in design practice. In this study, the above rock mass was defined as a good continuum rock mass and the quantitative setup criterion range was proposed using RMR, SMR and GSI classifications for the purpose of providing engineering standard for good continuum rock mass conditions. The methods of study are as follows. The stable slope at steep slopes ($65^{\circ}$ to $80^{\circ}$) for each rock type was selected as the study area, and RMR, SMR and GSI were classified to reflect the face mapping results. The results were reviewed by applying the calculated shear strength to the stable analysis of the current state of rock mass slope using the Hoek-Brown failure criterion. It is intended to verify the validity of the preliminary criterion as a rock mass condition that remains stable on a steep slope. Based on the analysis and review by the above research method, it was analyzed that a good continuum rock mass slope can be set to Basic RMR ${\geq}50$ (45 in sedimentary rock), GSI and SMR ${\geq}45$. The safety factor of the LEM is between Fs = 14.08 and 67.50 (average 32.9), and the displacement of the FEM is 0.13 to 0.64 mm (average 0.27 mm). This can be seen as a result of quantitative representation and verification of the stability of a good continuum rock mass slope that has been maintained stable for a long period of time with steep slopes ($65^{\circ}$ to $80^{\circ}$). The setup guideline for a good continuum rock mass slope will be able to establish a more detailed setup standard when the data are accumulated, and it is also a further study project. If stable even on steep slopes of 1 : 0.1 to 0.3, the upper limit of steep slopes is 1 : 0.3 with reference to the overseas design standards and report, thus giving the benefit of ensuring economic and eco-friendlyness. Also, the development of excavation technology and plantation technology and various eco-friendly slope design techniques will help overcome psychological anxiety and rapid weathering and relaxation due to steep slope construction.

The Verification of Physique and Physical Fitness Differences Through Bone Age and Chronological Age Among Adolescents (청소년들의 골연령과 역연령을 통한 체격과 체력의 차이 검증)

  • Kim, Dae-Hoon;Yoon, Hyoung-Ki;Oh, Sei-Yi;Lee, Young-Jun;Kim, Buem-Jun;Choi, Young-Min;Song, Dae-Sik;An, Ju-Ho;Seo, Dong-Nyeuck;Kim, Ju-Won;Na, Gyu-Min;Oh, Kyung-A
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.1
    • /
    • pp.318-331
    • /
    • 2021
  • This study was conducted on the assumption that bone age would be more effective when it comes to physique and physical fitness assessment for adolescents, and the purpose of this study was to identify the differences in physique and physical fitness for students in their adolescence through bone age and chronological age in order to contribute to the well-balanced physique and physical fitness development in adolescents and the health improvement in students. Total 874 adolescents(483 males, 391 females) aged 11~16 were selected as subjects out of the total population of 1100 adolescents aged 6~16 based on the PAPS(Physical Activity Promotion System) and age standards of the TW3 method; and skeletal maturation, which symbolize the indicators of biological maturation, were evaluated by using the TW3(Tanner-Whitehouse 3) method after hand-wrist radiographs, and birth date was used for chronological age. A stadiometer and InBody 270 (Biospace, Korea) were used to measure 2 components in physique. A total of 7 components in physical fitness, which included muscular strength, muscular endurance, flexibility, power, cardiovascular endurance, balance, agility, were measured as well. A independent samples t-test was conducted for data processing using SPSS 25.0, and the significance level was set at p< .05. The study results are as follows. First, bone age and chronological age used for physique comparison in males aged 11 and 12, height and weight showed significant difference; in males aged 13, weight showed signicant difference. Weight and height in females aged 11, and height in females aged 12 showed significant difference. Second, bone age and chronological age used for physical fitness comparison in males aged 11, muscular strength, power, flexibility, cardiovascular endurance showed significant difference; in males aged 12, muscular strength. power, cardiovascular endurance; in males aged 13, flexibility showed significant difference. Muscular strength, power, flexibility, muscular endurance, cardiovascular endurance in females aged 11, and flexibility in females aged 14 showed significant difference. As a result, this study concluded that in a period of rapid skeletal growth, evaluating physique and physical fitness based on bone age is more accurate than evaluating based on chronological age.

An Analysis on the Connectivity and Duplication of Curriculum Contents between Elementary and Secondary Levels on 'Family Life' Contents Area of the Practical Arts(Technology & Home Economics) Subject in the 2015 Revised Curriculum (2015 개정 실과(기술·가정) 교육과정의 초·중등 '가정생활' 분야의 연계성 및 중복성 분석)

  • Yoon, Ji Hyun
    • Journal of Korean Home Economics Education Association
    • /
    • v.34 no.1
    • /
    • pp.81-96
    • /
    • 2022
  • The purpose of this study was to examine the extent to which the contents of elementary and secondary curricula are connected and overlapped in the 'family life' area of Practical Arts(Technology & Home Economics) subjects. The procedure and results are as were like below. First, the types of criteria for analyzing curriculum contents are developed. The connectivity are classified as 'discontinuous hierarchy' and 'spiral hierarchy' and duplication are classified as 'repetition (high level of overlapping)', 'reproducing', 'deepening (intermediate level of overlapping)', 'substitution', and 'omission (low level of overlapping)'. Second, as a result of analyzing the contents of elementary and secondary curricula, the 'Human Development' area showed higher connectivity with a deepening type of duplication. The 'Safety' and the 'Lifelong Planning' concepts showed lower connectivity. Third, as a result of analyzing the achievement standards of the 2015 Curriculum, the secondary Home Economics curriculum showed a considerable increase in the level of difficulty and the volume compared to the elementary curriculum. There was low connectivity between the contents of elementary and secondary curricula in the core concepts 'Safety' and 'Lifelong Planning', an intermediate level of connectivity in 'Life Culture' and 'Management', and high connectivity in 'Development' and 'Relationship'. Also, there was a high level of duplication in the core concepts 'Safety' and 'Lifelong Planning', being classified as 'reproducing', 'substitution', and 'omission', analyzed to have low connectivity. When structuring the curriculum contents with a spiral hierarchy, one should connect the elementary and secondary school contents organically: the hierarchy with core concepts considering the different characters of constructuring knowledge in each school level, with a moderate volume, with a moderate difficulty level, with a moderate level of duplication of the contents, and with the minimum level of repetition of the same topics within the same school level.

Method of Reducing Separation Membrane Fouling Using Microbubbles (마이크로버블을 이용한 분리막 파울링 저감방법)

  • Kyung-Hwan Ku;Younghee Kim
    • Clean Technology
    • /
    • v.29 no.1
    • /
    • pp.31-38
    • /
    • 2023
  • Due to water shortages caused by water pollution and climate change, total organic carbon (TOC) standards have been implemented for wastewater discharged from public sewage treatment facilities. Furthermore, there is a growing interest and body of research pertaining to the reuse of sewage treatment water as a secure alternative water resource. The membrane bio-reactor (MBR) method is commonly used for advanced wastewater treatment because it can remove organic and inorganic ions and it does not require or emit any chemicals. However, the MBR process uses a separation membrane (MF), which requires frequent film cleaning due to fouling caused by a high concentration of mixed liquor suspended solid (MLSS). In this study, process improvement and microbubble cleaning efficiency were evaluated to improve the differential pressure, water flow, and MF fouling, which are the biggest disadvantages of operating the MF. The existing MBR method was improved by installing a precipitation tank between the air tank and the MBR tank in which raw water was introduced. Microbubbles were injected into a separation membrane tank into which the supernatant water from the precipitation tank was introduced. The microbubble generator was operated with a 15 day on, 15 day off cycle for 5 months to collect discharged water samples (4L) and measure TOC. As the supernatant water from the precipitation tank flowed into the separation membrane tank, about 95% of the supernatant water MLSS was removed so the MF fouling from biological contamination was prevented. Due to the application of microbubbles to supernatant water from the precipitation tank, the differential pressure of the separation membrane tank decreased by 1.6 to 2.3 times and the water flow increased by 1.4 times. Applying microbubbles increased the TOC removal rate by more than 58%. This study showed that separately operating the air tank and the separation membrane tank can reduce fouling, and suggested that applying additional microbubbles could improve the differential pressure, water flow, and fouling to provide a more efficient advanced treatment method.