• Title/Summary/Keyword: Technology standard model

Search Result 1,649, Processing Time 0.033 seconds

Better Housing for Effective Pig Production - Review -

  • Choi, H.L.;Song, J.I.;An, H.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.8
    • /
    • pp.1310-1315
    • /
    • 1999
  • Air quality in confinement pig houses is important to production and health. Mechanical ventilation and confinement is known to be the most practical tool for maintaining adequate air quality in pig houses through extensive researches since Millier (1950) invented the 'slotted inlet' ventilation system. A variety of mechanical ventilation systems have been applied to confined nursery pig houses in Korea without scientific verification of their ventilation effectiveness. Ventilation systems with three feasible combinations (NA, NB, and NC) of inlets and outlets in a confined nursery pig house were tested to evaluate their ventilation efficiency, of which the one with the performance was supposed to be taken as a standard ventilation system for nursery pig houses in Korea. Field data of air velocity and temperature fields, and ammonia concentration with three ventilation systems were taken and compared to determine the best system. The air velocity and temperature fields predicted by the PHOENICS computer program were also validated against the available experimental data to investigate the feasibility of computer simulation of air and temperature distribution with an acceptable accuracy in a confined house. NC system with duct-induced in-coming air, performed best among the three different ventilation systems, which created higher velocity field and evener distribution ($2.5m/s{\pm}0.3m/s$) over the space with a Reynolds number of $10^4$. The experimental data obtained also fitted well with the simulated values using the modified PHOENICS, which suggested a viable tool for the prediction of air and temperature field with given calculation geometries.

Design and manufacture of carrying along style HRV operational bioinstrumentation system that apply AVR MCU(II) (AVR MCU를 적용한 휴대형 HRV 생체 계측시스템의 설계 및 제작(II))

  • Kim, Whi-Young;Park, Doo-Yul
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.4
    • /
    • pp.295-302
    • /
    • 2007
  • Because Mobile computing uses radio transfer communications division carrying along information terminal, internet link computer and information technology of human body effectively, when, where, who, can offer role that is center enemy of available modern technology moving and reconsider new technology to physiological sounding, and reconstruct creatively. Specially, can offer possibility that can intervene in process that motive living body change before military register symptoms are developed of disease on silver society. But, much parameters data processing, standard anger of data of that is vague. same time collection of data can lift difficulty etc.. Therefore, this research excludes time limitation constituent inflecting Mobile computing, and result that analysis experiments because is proper and Mobile nerve mechanical code Tuesday that do with bioelectricity signal method select and embody system by access that become correct analysis, is becomes model of living body signal Mobile analysis device, and person could apply Mobile living body measuring device m-HSS (mobile-Hardware-software system) that measuring is possible by scientific access.

  • PDF

Developing a STEP-NC Prototype based on ISO 14649 Paradigm (ISO14649 패러다임에 입각한 STEP-NC 프로토타입 시스템 개발)

  • Seo, Seok-Hwan;Jo, Jeong-Hun;Jeong, Dae-Hyeok;Lee, Byeong-Eon;Cheon, Sang-Uk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.7
    • /
    • pp.171-179
    • /
    • 2002
  • STEP-NC is the next generation CNC controller taking STEP-based data model as the interface scheme (or language) between CAM and CNC, and carrying out various intelligent functions. At the moment, efforts are being made worldwide to establish international standard for the new interface scheme formalized as ISO14649. As the new language is being established, increasing attention is being paid to the development of the new CNC. Korea STEP-NC is an integrated STEP-NC system taking ISO 14649 as an input, and carrying out various intelligent functions. It is composed of 5 modules: 1) Shop Floor Programming System (PosSFP), 2) Tool Path Generator (PosTPG), 3) Tool Path Viewer (PosTPV), 4) Man Machine Interface (PosMMI), and 5) CNC Kernel (PosCNC). Distinguished from other prototypes (of Europe and USA), the Korea STEP-NC is top-down designed, and bottom-up implemented comprehensively incorporating all the crucial components for realizing the full benefit of STEP-NC paradigm, without using any existing commercial CAD/CAM systems and CNC kernels. The Korea STEP-NC prototype was successfully demonstrated and evaluated in the ISO conventions Together with prototypes of Europe and USA, Korea STEP-NC will be used as a reference system fur the Triangular Conformance Test to be jointly carried out by ISO TC184 SC1, SC4, and IMS Project.

A Novel Test Structure for Process Control Monitor for Un-Cooled Bolometer Area Array Detector Technology

  • Saxena, R.S.;Bhan, R.K.;Jalwania, C.R.;Lomash, S.K.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.4
    • /
    • pp.299-312
    • /
    • 2006
  • This paper presents the results of a novel test structure for process control monitor for uncooled IR detector technology of microbolometer arrays. The proposed test structure is based on resistive network configuration. The theoretical model for resistance of this network has been developed using 'Compensation' and 'Superposition' network theorems. The theoretical results of proposed resistive network have been verified by wired hardware testing as well as using an actual 16x16 networked bolometer array. The proposed structure uses simple two-level metal process and is easy to integrate with standard CMOS process line. The proposed structure can imitate the performance of actual fabricated version of area array closely and it uses only 32 pins instead of 512 using conventional method for a $16{\times}16$ array. Further, it has been demonstrated that the defective or faulty elements can be identified vividly using extraction matrix, whose values are quite similar(within the error of 0.1%), which verifies the algorithm in small variation case(${\sim}1%$ variation). For example, an element, intentionally damaged electrically, has been shown to have the difference magnitude much higher than rest of the elements(1.45 a.u. as compared to ${\sim}$ 0.25 a.u. of others), confirming that it is defective. Further, for the devices having non-uniformity ${\leq}$ 10%, both the actual non-uniformity and faults are predicted well. Finally, using our analysis, we have been able to grade(pass or fail) 60 actual devices based on quantitative estimation of non-uniformity ranging from < 5% to > 20%. Additionally, we have been able to identify the number of bad elements ranging from 0 to > 15 in above devices.

Development of $F_o-value$ Measuring System ($F_o$-값 측정 시스템의 개발)

  • CHO Hyun-Duk;HAN Bong-Ho;KIM Sang-Bong;OK Young-Gun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.6
    • /
    • pp.520-528
    • /
    • 1992
  • In order to establish the standard conditions for thermal sterilization of foods, a microcomputer based $F_o-value$ measuring system was developed upon the basis of the time-temperature profile in food. $F_o-value$ was calculated simultaneously from the time-temperature profile, and described as integrated lethality during the whole sterilization process. The accuracy of system was evaluated by the analysis of thermal diffusivity of the model solid food, Alaska pollack surimi. The $F_o-value$ could be measured precisely under the different sterilizing conditions as the varied time and temperature. The practical thermal diffusivities from various sterilizing conditions agreed well to the values predicted by some experimental equations suggested in the literatures. The differences were within the range of $\pm12\%$.

  • PDF

Design Methodology of the Frequency-Adaptive Negative-Delay Circuit (주파수 적응성을 갖는 부지연 회로의 설계기법)

  • Kim, Dae-Jeong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.3
    • /
    • pp.44-54
    • /
    • 2000
  • In this paper, a design methodology for the frequency-adaptive negative-delay circuit which can be implemented in standard CMOS memory process is proposed. The proposed negative-delay circuit which is a basic type of the analog SMD (synchronous mirror delay) measures the time difference between the input clock period and the target negative delay by utilizing analog behavior and repeats it in the next coming cycle. A new technology that compensates the auxiliary delay related with the output clock in the measure stage differentiates the Proposed method from the conventional method that compensates it in the delay-model stage which comes before the measure stage. A wider negative-delay range especially prominent in the high frequency performance than that in the conventional method can be realized through the proposed technology. In order to implement the wide locking range, a new frequency detector and the method for optimizing the bias condition of the analog circuit are suggested. An application example to the clocking circuits of a DDR SDRAM is simulated and demonstrated in a 0.6 ${\mu}{\textrm}{m}$ n-well double-poly double-metal CMOS technology.

  • PDF

Column Test for Evaluation on Removal Efficiency of Heavy Metal and Nutrients by Double Layered Permeable Reactive Barrier (주상실험을 통한 연속식 반응벽체에서의 복합오염물질 제거능 평가)

  • Oh, Myounghak;Kim, Yongwoo;Park, Junboum;Kwon, Osoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.5
    • /
    • pp.5-11
    • /
    • 2015
  • The double sheeted permeable reactive barrier containing two different reactive materials can be applied to remediate the groundwater contaminated by nutrients and heavy metals. In this study, in order to evaluate the removal efficiency of contaminants including ammonium, cadmium and phosphate by double layered permeable reactive barrier containing zeolite and steelmaking slag, column tests were performed. In addition, nonequilibrium reaction in column tests was analyzed by two-site nonequilibrium advection-dispersion model. Column test results showed that zeolite is effective for removal of ammonium, while steelmaking slag is effective for removal of phosphate and cadmium. The sequential reaction of zeolite and steelmaking slag gave the better removal efficiency for ammonium.

Estimation of GPS Holdover Performance with Ladder Algorithm Used for an UFIR Filter (UFIR 필터 Ladder 알고리즘 이용 GPS Holdover 성능 추정)

  • Lee, Young-kyu;Yang, Sung-hoon;Lee, Chang-bok;Heo, Moon-beom
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.7
    • /
    • pp.669-676
    • /
    • 2015
  • In this paper, we described the simulation results of the phase offset performance of a clock in holdover mode which was normally operated in GPS Disciplined Oscillator (GPSDO). In the TIE model, we included the time error term caused by environmental temperature variation because one of the most important parameters of clock phase error is the frequency offset and drift caused by the variation of temperature. For the simulation, we employed Maximum Time Interval Error (MTIE) for the performance evaluation when the frequency offset and drift are estimated by using an Unbiased Finite Impulse Response (UFIR) filter with ladder algorithm. We assumed that the noise in the GPS measurement is white Gaussian with zero mean and 1 ns standard deviation, and temperature linearly varies with a slope of $1{^{\circ}C}$ per hour. From the simulation results, the followings were observed. First, with the estimation error of temperature of less than 3 % and the temperature compensation period of less than 900 seconds, the requirement of CDMA2000 phase synchronization under 10 us could be achieved for more than 40,000 seconds holdover time if we employ an OCXO (Oven Controlled Crystal Oscillator) clock. Second, in order to achieve the requirement of LTE-TDD under 1.5 us for more than 10,000 seconds holdover time, below 3 % estimation error and 500 seconds should be retained if a Rubidium clock is adopted.

Study on Improvement of Response Spectrum Analysis of Pile-supported Structure: Focusing on the Natural Periods and Input Ground Acceleration (잔교식 구조물의 응답스펙트럼 해석법 개선사항 도출 연구: 고유주기 및 입력지반가속도를 중점으로)

  • Yun, Jung-Won;Han, Jin-Tae;Kim, Jong-Kwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.6
    • /
    • pp.17-34
    • /
    • 2020
  • In response spectrum analysis of pile-supported structure, an amplified seismic wave should be used as the input ground acceleration through the site-response analysis. However, each design standard uses different input ground acceleration criteria, which leads to confusion in determining the appropriate input ground acceleration. In this study, the ground accelerations were calculated through dynamic centrifuge model test, and the response spectrum analysis was performed using the calculated ground acceleration. Then, the moments derived from the test and analysis were compared, and a method for determining the appropriate input ground acceleration in response spectrum analysis was presented. Comparison of the experimental and simulated results reveals that modeling of the ground using elastic springs allows proper simulation of the natural period of the structure, and the use of a seismic wave that is amplified at the ground surface as the input ground acceleration provided the most accurate results for the response analysis of pile-supported structures in sands.

Whole-body Vibration Exposure of Drill Operators in Iron Ore Mines and Role of Machine-Related, Individual, and Rock-Related Factors

  • Chaudhary, Dhanjee Kumar;Bhattacherjee, Ashis;Patra, Aditya Kumar;Chau, Nearkasen
    • Safety and Health at Work
    • /
    • v.6 no.4
    • /
    • pp.268-278
    • /
    • 2015
  • Background: This study aimed to assess the whole-body vibration (WBV) exposure among large blast hole drill machine operators with regard to the International Organization for Standardization (ISO) recommended threshold values and its association with machine- and rock-related factors and workers' individual characteristics. Methods: The study population included 28 drill machine operators who had worked in four opencast iron ore mines in eastern India. The study protocol comprised the following: measurements of WBV exposure [frequency weighted root mean square (RMS) acceleration ($m/s^2$)], machine-related data (manufacturer of machine, age of machine, seat height, thickness, and rest height) collected from mine management offices, measurements of rock hardness, uniaxial compressive strength and density, and workers' characteristics via face-to-face interviews. Results: More than 90% of the operators were exposed to a higher level WBV than the ISO upper limit and only 3.6% between the lower and upper limits, mainly in the vertical axis. Bivariate correlations revealed that potential predictors of total WBV exposure were: machine manufacturer (r = 0.453, p = 0.015), age of drill (r = 0.533, p = 0.003), and hardness of rock (r = 0.561, p = 0.002). The stepwise multiple regression model revealed that the potential predictors are age of operator (regression coefficient ${\beta}=-0.052$, standard error SE = 0.023), manufacturer (${\beta}=1.093$, SE = 0.227), rock hardness (${\beta}=0.045$, SE = 0.018), uniaxial compressive strength (${\beta}=0.027$, SE = 0.009), and density (${\beta}=-1.135$, SE = 0.235). Conclusion: Prevention should include using appropriate machines to handle rock hardness, rock uniaxial compressive strength and density, and seat improvement using ergonomic approaches such as including a suspension system.