• Title/Summary/Keyword: Technology Value Assessment

Search Result 607, Processing Time 0.036 seconds

Assessment of the Economic Benefits from Electricity Consumption (전력 소비의 용도별 경제적 편익 평가)

  • Lim, Seul-Ye;Park, Jae-Hyung;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.9-16
    • /
    • 2015
  • As electricity is an indispensable input to human's existence and industrial production, economic benefits arise from consumption. The economic benefits of the electricity consumption are useful information in various fields of electricity-related policy. Therefore, this study attempts to value the economic benefits from electricity use. The economic benefit of electricity consumed is the area under the demand curve which made of the sum of the actual consumer expenditure and the consumer surplus. Consumer expenditure can be easily observed but the information on price elasticity of demand is necessarily required to compute consumer surplus. This study derives the estimates for price elasticities through literature review. The price elasticities of the electricity demand for residence, industry, and commercial are estimated to be -0.332, -0.351, and -0.263, respectively. Because the consumer surplus of the electricity consumption for residence, industry, and commercial are computed to be 191.54, 143.44, and 231.91 won per kWh, respectively. Given that average prices of electricity use were 127.02, 100.70, and 121.98 won per kWh for the year 2013, the economic benefit are calculated to be 318.56, 244.14, and 353.89 won per kWh, respectively. We can convert the values to 321.96, 246.75, and 357.67 won per kWh in 2014 constant price, respectively, using consumer price index. They can be used in the economic feasibility analysis of a new electricity supply project.

Methodology for Quantitative Monitoring of Agricultural Worker Exposure to Pesticides (농작업자에 대한 농약 노출의 정량적 측정 방법)

  • Kim, Eun-Hye;Lee, Hye-Ri;Choi, Hoon;Moon, Joon-Kwan;Hong, Soon-Sung;Jeong, Mi-Hye;Park, Kyung-Hun;Lee, Hyo-Min;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.507-528
    • /
    • 2011
  • Agricultural workers who mix/loads and spray pesticide in fields expose to pesticide through dermal and inhalation routes. In such situation, exposed amount should be measured quantitatively for reasonable risk assessment. Patch, gloves, socks and mask will be good materials for monitoring for dermal exposure while personal air monitor equipped with solid adsorbent and air pump will be a tool for inhalation exposure. For extrapolation of absorbed amount in dermal exposure matrices and of trapped amount in solid sorbent to total deraml or inhalation exposure, Korean standard body surface area and respiration rate were proposed in substitution of EPA data. Important exposure factors such as clothing and skin penetration ratio of dermal and inhalation exposure were suggested based on Spraying time for exposure monitoring must be long enough that the amount of pesticide to get absorbed/trapped in exposure matrices results in reasonable analytical value. In domestic case for the both of speed sprayer and power spray machine, spraying time of 20~40 minutes (0.1~0.2 ha) will be reasonable per single replicate before extrapolating to 4 hours a day with triplicates experiment.

Effect of Silicone Rubber Content on Thermal Stabilities of EPDM/Silicone Blends (실리콘고무 함량이 EPDM 고무의 열적 안정성에 미치는 영향)

  • Park, Soo-Jin;Kim, Jong-Hak;Joo, Hyeok-Jong;Jin, Fan-Long
    • Elastomers and Composites
    • /
    • v.40 no.4
    • /
    • pp.266-271
    • /
    • 2005
  • In this work, the thermal stability factors, such as the thermal decomposition temperature, decomposition activation energy ($E_d$), and char yield, were measured to investigate the effect of silicone rubber (SR) content on the thermal stabilities of EPDM/SR blends. As a result, the thermal decomposition curve of EPDM/SR blends was similar to the neat EPDM rubber at 10 wt% SR and the thermal decomposition temperature increased above this content. The $E_d$ value of EPDM rubber initially decreased and then was constant above 20 wt% weight losses. The $E_d$ of EPDM/SR blends was higher than that of the neat EPDM rubber and then decreased with increasing the weight loss when the SR content was in the range of 10-20 wt%. Whereas the $E_d$ of the blends was lower than that of the EPDM rubber and then decreased with increasing the weight loss when 30 wt% SR was added. The char yield at $800^{\circ}C$ increased with increasing the SR content, because the decomposition of silane groups in the backbone was capable of forming a silane-rich residue after the initial stage of thermal degradation, which finally prevents further heat transfer and diffusion in the blends.

Analysis of Streamflow Characteristics of Boryeong-dam Watershed using Global Optimization Technique by Infiltraion Methods of CAT (CAT 모형의 침투해석방법별 전역최적화기법을 이용한 보령댐 유역의 유출 특성 변화 분석)

  • Park, Sanghyun;Kim, Hyeonjun;Jang, Cheolhee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.412-424
    • /
    • 2019
  • In this study, the changes of the streamflow characteristics of the watershed were analysed depending on the infiltration methods of CAT. The study area, Boryeong-dam watershed located in Chungcheongnam-do area, has been suffered from severe drought in recent years and stabilized regarding on the storage rate through efforts such as constructing a channel connecting the upstream of Boryeong-dam from the downstream of the Geum river. In this study, the effects of soil infiltration parameters on the watershed streamflow characteristics were analyzed by the infiltration methods of CAT such as Rainfall Excess, Green&Ampt and Horton. And the parameter calibrations were conducted by SCEUA-P, a global optimization technique module of the PEST, the package for parameter optimization and uncertainty analysis, to compare the yearly variations of soil parameters for infiltration methods of CAT. In addition, the streamflow characteristics were analyzed for three infiltration methods by applying three different scenarios, such as applying calibrated parameters for every years to simulate the model for each years, applying calibrated parameters for the entire period to simulate the model for entire period, and applying the average value of yearly calibrated parameters to simulate the model for entire period.

Techno-Economic Analysis of Reversible Solid Oxide Fuel Cell System Couple with Waste Steam (폐스팀을 이용한 가역 고체산화물 연료전지의 기술적 경제적 해석)

  • GIAP, VAN-TIEN;LEE, YOUNG DUK;KIM, YOUNG SANG;AHN, KOOK YOUNG
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.1
    • /
    • pp.21-28
    • /
    • 2019
  • Reversible solid oxide fuel cell (ReSOC) system was integrated with waste steam for electrical energy storage in distributed energy storage application. Waste steam was utilized as external heat in SOEC mode for higher hydrogen production efficiency. Three system configurations were analyzed to evaluate techno-economic performance. The first system is a simple configuration to minimize the cost of balance of plant. The second system is the more complicated configuration with heat recovery steam generator (HRSG). The third system is featured with HRSG and fuel recirculation by blower. Lumped models were used for system performance analyses. The ReSOC stack was characterized by applying area specific resistance value at fixed operating pressure and temperature. In economical assessment, the levelized costs of energy storage (LCOS) were calculated for three system configurations based on capital investment. The system lifetime was assumed 20 years with ReSOC stack replaced every 5 years, inflation rate of 2%, and capacity factor of 80%. The results showed that the exergy round-trip efficiency of system 1, 2, 3 were 47.9%, 48.8%, and 52.8% respectively. The high round-trip efficiency of third system compared to others is attributed to the remarkable reduction in steam requirement and hydrogen compression power owning to fuel recirculation. The result from economic calculation showed that the LCOS values of system 1, 2, 3 were 3.46 ¢/kWh, 3.43 ¢/kWh, and 3.14 ¢/kWh, respectively. Even though the systems 2 and 3 have expensive HRSG, they showed higher round-trip efficiencies and significant reduction in boiler and hydrogen compressor cost.

Monitoring and risk assessment of 1,4-Dioxane in Nakdong river (낙동강 수계 중 1,4-dioxane의 모니터링 및 위해성 평가)

  • Lee, Ji-Young;Kim, Joung-Hwa;Kim, Hyun-Koo;Choi, Jong-Ho;Kim, Seungki;Pyo, Heesoo
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.383-391
    • /
    • 2008
  • International Agency for Research on Cancer (IARC) has classified it as a possible carcinogen and World Health Organization (WHO) has suggested 50 ng/mL as a guideline value for 1,4-dioxane. Considering the toxicity of 1,4-dioxane and ingestion rate of drinking water, the monitoring of 1,4-dioxane in drinking water in Nakdong river is very important. We analyzed 1,4-dioxane four times per year for the 12 samples of treated water and 4 samples of raw water in Nakdong river in Korea from 2000 to 2007 and surveyed the trend of concentrations of 1,4-dioxane. As a results of analysis, 1,4-dioxane was detected from 0.24 to 240.2 ng/mL in treated water and from 0.39 to 81.9 ng/mL in raw water from 2000 to 2007. The average concentrations are 22.68 ng/mL and 19.15 ng/mL in treated water and raw water, respectively. The detected concentrations was decreased but frequency of detection was not changed since establishment of regulation in 2004. Results of comparison of 95 percentile excessive cancer risk of 1,4-dioxane in treated and raw water were each $6.63{\times}10^{-6}$, $3.17{\times}10^{-6}$ before 2004 and $2.10{\times}10^{-6}$, $1.22{\times}10^{-6}$ after 2004. Also, comparing the detected concentration and frequency for each season, these were more detected the concentration and frequency for 1,4-dioxane in treated and raw water from winter to spring.

Analysis of Image Processing Characteristics in Computed Radiography System by Virtual Digital Test Pattern Method (Virtual Digital Test Pattern Method를 이용한 CR 시스템의 영상처리 특성 분석)

  • Choi, In-Seok;Kim, Jung-Min;Oh, Hye-Kyong;Kim, You-Hyun;Lee, Ki-Sung;Jeong, Hoi-Woun;Choi, Seok-Yoon
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.97-107
    • /
    • 2010
  • The objectives of this study is to figure out the unknown image processing methods of commercial CR system. We have implemented the processing curve of each Look up table(LUT) in REGIUS 150 CR system by using virtual digital test pattern method. The characteristic of Dry Imager was measured also. First of all, we have generated the virtual digital test pattern file with binary file editor. This file was used as an input data of CR system (REGIUS 150 CR system, KONICA MINOLTA). The DICOM files which were automatically generated output files by the CR system, were used to figure out the processing curves of each LUT modes (THX, ST, STM, LUM, BONE, LIN). The gradation curves of Dry Imager were also measured to figure out the characteristics of hard copy image. According to the results of each parameters, we identified the characteristics of image processing parameter in CR system. The processing curves which were measured by this proposed method showed the characteristics of CR system. And we found the linearity of Dry Imager in the middle area of processing curves. With these results, we found that the relationships between the curves and each parameters. The G value is related to the slope and the S value is related to the shift in x-axis of processing curves. In conclusion, the image processing method of the each commercial CR systems are different, and they are concealed. This proposed method which uses virtual digital test pattern can measure the characteristics of parameters for the image processing patterns in the CR system. We expect that the proposed method is useful to analogize the image processing means not only for this CR system, but also for the other commercial CR systems.

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF

Suitability of Measuring a Kidney Depth with Assessment of Glomerular Filtration Rateusing 99mTc-DTPA in the Ectopic Kidney and Pediatric Patients (99mTc-DTPA를 이용한 사구체여과율 검사에서 이소성 신장과 소아 환자의 신장 깊이 측정방법의 적절성)

  • Choi, Jae Min;Lee, Young Hee;Shim, Dong Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • A glomerular filtration rate (GFR) study is a test that uses radioactive materials or tracers (radiopharmaceuticals) and a computer to see how well the kidneys are working. Asan Medical Center analyzed and compared data between kidney depth, acquired from kidney donors' CT image and acquired from Gates method's GFR value that are calculated by Tonnesen equation. This study was able to confirm that kidney depth measured from CT image was higher than the Gates Method's GFR value, which was calculated by Tonnessen equation; the direct relationship among pathologic results is confirmed. Particularly, kidney donor whose kidney was at the pelvic area had direct relationship with other clinical results. During the GFR test, it is necessary to confirm the location of kidney has no change with reference of CT image. If kidney depth is manually corrected using CT image when we measures GFR of deformed or horse-shoe kidney, it would be possible to acquire the compatible value which is equivalent to clinical result. There would be a possible issue of appropriateness that whether the applied GFR using CT image's kidney depth has clinical validity. In case of a pediatric patient, the GFR derived from Tonnesen was quiet underestimated while manual method and Gordon stay in normal range. Which results may be correct among them? There have been many reports about kidney depth, to be an accurate index of GFR in children. As one of the study performers, we should contemplate what the best option for pediatric patients would be.

  • PDF

Assessment and Comparison of SUVs of Three Different PET/CT Scanners (장비에 따른 SUV의 차이와 이에 관한 고찰)

  • Kim, Tae-Yeob;Lim, Jung-Jin;Lee, Hong-Jae;Kim, Hyun-Joo;Kim, Joong-Hyun;Lee, Jae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.34-38
    • /
    • 2011
  • Purpose: The SUV is a widely used semi-quantitative index in PET for the estimation of radio-tracer accumulation in VOI. In this study, SUVs from three different PET/CT scanners were assessed, and differences between SUVs were evaluated. Materials and Methods: The PET/CT scanners which were assessed in this study were GEMINI, GEMINI TF 64 (Philips) and Biograph True Point True V 40 (Siemens). The NEMA PET phantom (Data Spectrum Corp., USA) was used to evaluate SUVs. The NEMA PET phantom has6.8 kg weight and three hot inserts. Two different activity distributions for the background and inserts were tested. The activity ratio were 3.7:3.7:7.4:11.1 MBq (1:1:2:3) and 1.85:7.4:9.25:11.1MBq (1:4:5:6) for each of background, insert 1, insert 2 and insert 3. Acquisition time was 2 minutes per bed position and NEMA PET phantom could be covered by two bed positions for all PET/CT scanners. The SUVs from each PET/CT scanner were compared with calculated true value. Results: For both activity ratios, all scanners showed similar results. The differences between each scanner were insignificant. Each scanner showed 91.2%, 85.9% and 87.2% of true SUV for GEMINI, GEMINI TF 64, Biograph True Point TrueV, respectively. Conclusion: For all scanners, SUVs were slightly lower than true value. However, the difference between scanners was insignificant. The SUVs from these scanners would be clinically meaningful if their consistent underestimation is kept in mind.

  • PDF