• Title/Summary/Keyword: Technology Use

Search Result 24,600, Processing Time 0.052 seconds

Development of Sample Survey Design for the Industrial Research and Development Statistics (표본조사에 의한 기업 연구개발활동 통계 작성방안)

  • Cho, Seong-Pyo;Park, Sun-Young;Han, Ki-In;Noh, Min-Sun
    • Journal of Technology Innovation
    • /
    • v.17 no.2
    • /
    • pp.1-23
    • /
    • 2009
  • The Survey on the Industrial Research and Development(R&D) is the primary source of information on R&D performed by Korea industrial sector. The results of the survey are used to assess trends in R&D expenditures. Government agencies, corporations, and research organizations use the data to investigate productivity determinants, formulate tax policy, and compare individual company performance with industry averages. Recently, Korea Industrial Technology Association(KOITA) has collected the data by complete enumeration. Koita has, currently, considered sample survey because the number of R&D institutions in industry has been dramatically increased. This study develops survey design for the industrial research and development(R&D) statistics by introducing a sample survey. Companies are divided into 8 groups according to the amount of R&D expenditures and firm size or type. We collect the sample from 24 or 8 sampling strata and compare the results with those of complete enumeration survey. The estimates from 24 sampling strata are not significantly different to the results of complete enumeration survey. We propose the survey design as follows: Companies are divided into 11 groups including the companies of which R&D expenditures are unknown. All large companies are included in the survey and medium and small companies are sampled from 70% and 3%. Simple random sampling (SRS) is applied to the small company partition since they show uniform distribution in R&D expenditures. The independent probability proportionate to size (PPS) sampling procedure may be applied to those companies identified as 'not R&D performers'. When respondents do not provide the requested information, estimates for the missing data are made using imputation algorithms. In the future study, new key variables should be developed in survey questionnaires.

  • PDF

The Study of Dose Distribution according to the Using Linac and Tomotherapy on Total Lymphnode Irradiation (선형가속기와 토모치료기를 이용한 전림프계의 방사선 치료시 선량분포에 관한 연구)

  • Kim, Youngjae;Seol, Gwanguk
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.285-291
    • /
    • 2013
  • In this study, compare and analyze the dose distribution and availability of radiation therapy when using a different devices to TNI(Total Lymphnodal Irradiation). Test subjects(patients) are 15 people(Male 7, Female 8). Acquire CT Simulation images of the 15 people using Somatom Sansation Open 16 channel and then acquired images was transferred to each treatment planning system Pinnacle Ver 8.0 and Tomotherapy Planning System and separate the tumor tissue and normal tissues(whole lung, spinal cord, Rt kidney, Lt kidney). Tumor prescription dose was set to 750 cGy. and then Compare the Dose Compatibility, Normal Tissue's Absorbed Dose, Dose Distribution and DVH. Statistical analysis was performed SPSS Ver. 18.0 by paired sample Assay. The absorbed dose in the tumor tissue was $751.0{\pm}4.7cGy$ in tomotherapy planning, $746.9{\pm}14.1cGy$ in linac. Tomotherapy's absorbed dose in the tumor was more appropriate than linac. and These values are not statistically significant(p>0.05). Tomotherapy plan's absorbed dose in the normal tissues were less than linac's plan. This value was statistically significant(p<0.05) excepted of whole lung. In DVH, appropriated on tumor and normal tissues in tomotherapy and linac but tomotherapy's TER was better than linac. Namely, a result of Absorbed dose in tumor and normal tissue, Dose distribution pattern, DVH, Both radiation therapy devices were appropriated in radiation therapy on TER. The Linac has a short treatment time(about 15-20 min) and open space on treatment time. It cause infant and pediatric patients to receiving uncomfortable treatment. So, In this case, it will be fine that Linac based therapy was restricted use. and if the patient was cooperative, it will be show a better prognosis that Tomotherapy using Radiation Therapy.

The Effects of Virtual Reality Advertisement on Consumer's Intention to Purchase: Focused on Rational and Emotional Responses (가상현실(Virtual Reality) 광고가 소비자 구매의도에 미치는 영향: 이성적인 반응과 감성적인 반응의 통합)

  • Cha, Jae-Yol;Im, Kun-Shin
    • Asia pacific journal of information systems
    • /
    • v.19 no.4
    • /
    • pp.101-124
    • /
    • 2009
  • According to Wikipedia, virtual reality (VR) is defined as a technology that allows a user to interact with a computer-simulated environment. Due to a rapid growth in information technology (IT), the cost of virtual reality has been decreasing while the utility of virtual reality advertisements has dramatically increased. Nevertheless, only a few studies have investigated the effects of virtual reality advertisement on consumer behaviors. Therefore, the objective of this study is to empirically examine the effects of virtual reality advertisement. Compared to traditional online advertisements, virtual reality advertisement enables consumers to experience products realistically over the Internet by providing high media richness, interactivity, and telepresence (Suh and Lee, 2005). Advertisements with high media richness facilitate consumers' understanding of advertised products by providing them with a large amount and a high variety of information on the products. Interactivity also provides consumers with a high level of control over the computer-simulated environment in terms of their abilities to adjust the information according to their individual interests and concerns and to be active rather than passive in their engagement with the information (Pimentel and Teixera, 1994). Through high media richness and interactivity, virtual reality advertisements can generate compelling feelings of "telepresence" (Suh and Lee, 2005). Telepresence is a sense of being there in an environment by means of a communication medium (Steuer, 1992). Virtual reality advertisements enable consumers to create a perceptual illusion of being present and highly engaged in a simulated environment, while they are in reality physically present in another place (Biocca, 1997). Based on the characteristics of virtual reality advertisements, a research model has been proposed to explain consumer responses to the virtual reality advertisements. The proposed model includes two dimensions of consumer responses. One dimension is consumers' rational response, which is based on the Information Processing Theory. Based on the Information Processing Theory, product knowledge and perceived risk are selected as antecedents of intention to purchase. The other dimension is emotional response of consumers, which is based on the Attitude-Structure Theory. Based on the Attitude-Structure Theory, arousal, flow, and positive affect are selected as antecedents of intention to purchase. Because it has been criticized to have investigated only one of the two dimensions of consumer response in prior studies, our research model has been built so as to incorporate both dimensions. Based on the Attitude-Structure Theory, we hypothesized the path of consumers' emotional responses to a virtual reality advertisement: (H1) Arousal by the virtual reality advertisement increases flow; (H2) Flow increases positive affect; and (H3) Positive affect increases intension to purchase. In addition, we hypothesized the path of consumers' rational responses to the virtual reality advertisement based on the Information Processing Theory: (H4) Increased product knowledge through the virtual reality advertisement decreases perceived risk; and (H5) Perceived risk decreases intension to purchase. Based on literature of flow, we additionally hypothesized the relationship between flow and product knowledge: (H6) Flow increases product knowledge. To test the hypotheses, we conducted a free simulation experiment [Fromkin and Streufert, 1976] with 300 people. Subjects were asked to use the virtual reality advertisement of a cellular phone on the Internet and then answer questions about the variables. To check whether subjects fully experienced the virtual reality advertisement, they were asked to answer a quiz about the virtual reality advertisement itself. Responses of 26 subjects were dropped because of their incomplete answers. Responses of 274 subjects were used to test the hypotheses. It was found that all of six hypotheses are accepted. In addition, we found that consumers' emotional response has stronger impact on their intention to purchase than their rational response does. This study sheds much light into practical implications for both IS researchers and managers. First of all, while most of previous research has analyzed only one of the customers' rational and emotional responses, we theoretically incorporated and empirically examined both of the two sides. Second, we empirically showed that mediators such as arousal, flow, positive affect, product knowledge, and perceived risk play an important role between virtual reality advertisement and customer's intention to purchase. In addition, the findings of this study can provide a basis of practical strategies for managers. It was found that consumers' emotional response is stronger than their rational response. This result indicates that advertisements using virtual reality should focus on the emotional side, and that virtual reality can be served as an appropriate advertisement tool for fancy products that require their online advertisements to give an impetus to customers' emotion. Finally, even if this study examined the effects of virtual reality advertisement of cellular phone, its findings could be applied to other products that are suited for virtual experience. However, this research has some limitations. We were unable to control different kinds of consumers and different attributes of products on consumers' intention to purchase. It is, therefore, deemed important for future research to control the consumer and product types for more reliable results. In addition to the consumer and product attributes, other variables could affect consumers' intention to purchase. Thus, the future research needs to find ways t control other variables.

Resolution Evaluation of a Pinhole Collimator according to the Aperture Diameter using Micro Deluxe Phantom (Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가)

  • An, Byung Ho;Yeon, Joon Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.3-11
    • /
    • 2015
  • Purpose It is hard to obtain high quality images of knee and T.M joint because of a lot of soft tissues in the knee and T.M joint area. Most conventional system for high resolution scintigraphy was used by 4 mm aperture pinhole collimator. Performance comparison of high-resolution pinhole SPECT for Micro deluxe phantom using conventional system. the aim of this study is to evaluate performance of each aperture according to the diameter size and the usefulness of 24-hour delayed bone scintigraphy. Materials and Methods In this study 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture and Micro Deluxe phantom was used for performance comparison of conventional SPECT system, Projection data were obtained with 9 degree increment per 30 second. Transverse images were reconstructed using dedicated OSEM algorithm with recovery of detector blurring. $^{99m}Tc-HDP$ source was used for 24-hour delayed bone scintigraphy. Results The knee joint images obtained with 24-hour delay were improved more than those obtained with 3-hour delay in our study. The 6 mm and 8 mm pinhole collimators FWHM have improved by 28% SNR and Uniformity have improved by 35%, Contrast has improved by 7% in 24-hour delayed knee joint image. While in 24-hour delayed T.M joint image of the 6 mm and 8 mm pinhole collimators FWHM have decreased by 60% SNR has decreased by 20% and Uniformity has decreased by 25%, Contrast has decreased significantly. Conclusion Pinhole collimators with 6 mm and 8 mm diameter could offer a superior performance for 24-hour delayed bone scintigraphy. The use of 24-hour delayed image provides additional benefits for pinhole scintigraphy of knee joint. Therefore, we expect that it is useful for precise diagnosis of knee joint and it is applicable to others joint imaging.

  • PDF

Quality Assessment and Comparison of Several Radioimmunoassay Kits and Chemiluminescence Immunoassay Methods for Evaluating Serum Estradiol (혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교)

  • Choi, Sung Hee;Noh, Gyeong Woon;Kim, Jin Eui;Song, Yoo Sung;Paeng, Jin Chul;Kang, Keon Wook;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • Purpose Serum estradiol ($E_2$) measurement is requested for diagnosing menstrual cycles, ovulation induction, infertility, and menopause. $E_2$ is measured using several methods and kits including radioimmunoassay (RIA) and chemiluminescece immunoassay (CLIA). The purpose of this study was to evaluate quality of these methods and to compare them with each other. Materials and Methods Seven radioimmunoassay kits and two CLIA methods were included in the analysis. Using standard samples and patient samples, intra-assay precision, inter-assay precision, correlation between other methods, sensitivity, and recovery rate were evaluated. Results For all tested kits and methods, coefficients of variance (CVs) of intra-assay precision test were 10.9~13.6% in low-level samples and less than 10% in medium and high-level samples. CVs of inter-assay precision test were 10.8~12.3% in low-level samples and less than 10% in medium and high-level samples with all tested kits and methods. Recovery rates were $92.7{\pm}12.4%$ for SIEMENS, $101.4{\pm}18.4%$ for DIAsource, $95.1{\pm}11.5%$ for AMP, $108.4{\pm}18.5%$ for BECKMAN COULTER, $104.2{\pm}13.5%$ for BECKMAN COULTER Ultra Sensitive, $101.3{\pm}11.6%$ for CIS Bio, and $93.1{\pm}13.2%$ for MP kits. Sensitivity was 7.5, 6.2, 5.7, 6.2, 5.3, 4.5, and 5.5 pg/mL for SIEMENS, DIAsource, AMP, BECKMAN COULTER, BECKMAN COULTER Ultra Sensitive, CIS Bio, and MP kits, respectively. The measurement by MP kit was slightly higher than those by other kits in low-level samples, and the measurement by E170 was slightly higher than those of other kits in medium and high-level samples. In the measurement of standard sample for external quality control, SIEMENS kit produced relatively lower values whereas E170, Architect, and MP kits produced relatively higher values compared with other kits. Conclusion All tested kits for $E_2$ measurement have satisfactory performance for clinical use. However, correlation between kits should be considered when test kits are to be changed, because some pairs of kits do not have correlations with each other.

  • PDF

A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume (Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰)

  • Kim, Jin Gu;Ham, Jun Cheol;Oh, Shin Hyun;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Purpose It is intended to figure out the errors derived from changes in depth and volume when measuring the Standard source and 99mTc-pertechnetate by using a Dose calibrator. Then recommend appropriate measurement depth and volume. Materials and Methods As a Dose calibrator, CRC-15βeta and CRC-15R (Capintec, New Jersey, USA) was used, and the measurement sources were 57Co, 133Ba, 137Cs and 99mTc-pertechnetate was also adopted due to its high frequency of use. The Standard source was respectively measured the changes according to its depth without changing the volume, in a range of 0 cm to 15 cm from the bottom of the ion chamber. 99mTc-pertechnetate was measured at each depth by changing the volume with 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL and 0.9 mL Respectively. And the depth range was from 0 cm to 15 cm at the bottom of the ion chamber. Results In the case of Standard source 57Co, 133Ba, 137Cs and 99mTc-pertechnetate, there were significant differences according to the measurement depth(p<0.05). 99mTc-pertechnetate has a negative correlation coefficient according to the depth, and the error of the measured value was negligible at a depth from 0 cm to 7 cm at 0.3 mL and 0.5 mL, and the range of error increased as the volume increased. Conclusion In clinical practice, it is sometimes installed differently than the Standard depth recommended by the equipment company. If it's measured at the recommended depth and volume, it could be thought that unnecessary exposure of the operator and the patient will be reduced, and more accurate radiation exams will be possible in quantitative analysis.

Analysis and Design of Profiling Adaptor for XML based Energy Storage System (XML 기반의 에너지 저장용 프로파일 어댑터 분석 및 설계)

  • Woo, Yongje;Park, Jaehong;Kang, Mingoo;Kwon, Kiwon
    • Journal of Internet Computing and Services
    • /
    • v.16 no.5
    • /
    • pp.29-38
    • /
    • 2015
  • The Energy Storage System stores electricity for later use. This system can store electricity from legacy electric power systems or renewable energy systems into a battery device when demand is low. When there is high electricity demand, it uses the electricity previously stored and enables efficient energy usage and stable operation of the electric power system. It increases the energy usage efficiency, stabilizes the power supply system, and increases the utilization of renewable energy. The recent increase in the global interest for efficient energy consumption has increased the need for an energy storage system that can satisfy both the consumers' demand for stable power supply and the suppliers' demand for power demand normalization. In general, an energy storage system consists of a Power Conditioning System, a Battery Management System, a battery cell and peripheral devices. The specifications of the subsystems that form the energy storage system are manufacturer dependent. Since the core component interfaces are not standardized, there are difficulties in forming and operating the energy storage system. In this paper, the design of the profile structure for energy storage system and realization of private profiling system for energy storage system is presented. The profiling system accommodates diverse component settings that are manufacturer dependent and information needed for effective operation. The settings and operation information of various PCSs, BMSs, battery cells, and other peripheral device are analyzed to define profile specification and structure. A profile adapter software that can be applied to energy storage system is designed and implemented. The profiles for energy storage system generated by the profile authoring tool consist of a settings profile and operation profile. Setting profile consists of configuration information for energy device what composes energy saving system. To be more specific, setting profile has three parts of category as information for electric control module, sub system, and interface for communication between electric devices. Operation profile includes information in relation to the method in which controls Energy Storage system. The profiles are based on standard XML specification to accommodate future extensions. The profile system has been verified by applying it to an energy storage system and testing charge and discharge operations.

Evaluation on Heating Effects of Geothermal Heat Pump System in Farrowing House (지열 난방시스템을 이용한 분만돈사의 난방효과 분석)

  • Choi, H.C.;Park, Jae-Hong;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.205-215
    • /
    • 2010
  • Geothermal heat pump system (GHPS) is an energy-efficient technology that use the relatively constant and renewable energy stored in the earth to provide heating and cooling. With the aim of using GHPS as a heating source, it's possibilities of application in farrowing house were examined by measuring environmental assessment and sow's performance. A total of 96 sows were assigned to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in winter season. During the experimental period, indoor maximum temperature in GHPS-housing was measured up to $26.7^{\circ}C$, average temperature could maintain $21.2^{\circ}C$. The mean value of dust levels and $CO_2$, $NH_3$ and $H_2S$ gas emissions were decreased in GHPS-housing compare with those of conventional housing. Litter size, birth weight, parity and weaning weight did not differ between housings. However, feed intake of sow in GHPS-housing was lower than that of conventional housing. In energy consumption for heating, electric power consumption increased in GHPS-housing than the conventional housing, a 2,250 kwh increase, whereas there is no fuel usage for heater in GHPS-housing. Amount of ground water circulated for heating in cold weather for earth heat exchanger was 8.4-12.9 ton per day. In conclusion, GHPS may have environmental benefits and effectiveness of heating in farrowing housing and affect the performance in sows.

Studies on the CA Storage of Sweet Persimmon in Polyethylene Film Pack (Polyethylene film포장(包裝)에 의(依)한 단감의 CA저장(貯藏)에 관(關)한 연구(硏究))

  • Min, Byong-Yong;Oh, Sang-Lyong
    • Korean Journal of Food Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.128-134
    • /
    • 1975
  • For development of long-term storage method of sweet-persimmons using polyethylene film bags, basic experiment was conducted with 30 boxes of sweet-persimmons in 1973 and the same experiment was extended for industrial application with 2,500 boxes of the persimmons in the cold storage of Jinyoung Sweet-persimmon Association in 1974. Investigation was made on change of the quality by storage period. At the same time, persimmons put in the cold storage test were shipped to market at different time in order to monitor consumer response and commercial feasibility. The followings are conclusion obtained from the result of this experiment. 1. Storage of sweet-persimmon, Buyu, produced in Jinyoung, Kimhae was possible for 1 month at $2^{\circ}C{\pm}1^{\circ}C$ cold storage. This storage period was extended to 4 months until the end of February in case that the fruits were hermetically sealed in P.E. film bags of 0.08 to 0.1 mm thickness. 2. During the storage period of sweet-persimmons packed in the film bags, the loss of weight due to evaporation was effectively prevented with use of the film of bag thicker than 0.04 mm. 3. The storage ability of 3-5 persimmons per small bag was somewhat superior to that of many persimmons packed in the large box of 15kg capacity. 4. The thicker the film of bags, the more $CO_2$ gas was accumulated inside, however, from 1 month after beginning of the storage the rate of $CO_2$ accumulation became very low maintaining the stabilized level of 5-6% at the plot of 0.06-0.08mm thick bags. 5. While the persimmons were in storage, decreased was the content of total sugars, total acids, and vitamin C, of which the phenomenon was remarkable especially with the fruits of non-packed plot. 6. The sweet-persimmons in the film bags subjected to cold storage when shipped to market in their intact condition were more beneficial than when they were shipped out in unpacked condition. The intact fruits packed in the P.E. film bags were able to keep their commercial value for 10days in the outdoor situation. 7. The sweet-persimmons that were packed in the film bags and put in the cold storage had maintained promissing marketability and the economic feasibility was acknowledged when the experimental practice was applied to industrial scale.

  • PDF

The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Bandwidth Enhancement of a Ultrasonic Transducer Using Double Acoustic Matching Layers- (어종식별을 위한 광대역 초음파 변환기의 설계 ( III ) - 이중음향정합층을 이용한 초음파 변환기의 대역폭 확장 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.1
    • /
    • pp.85-95
    • /
    • 1998
  • The broadband ultrasonic transducers have been designed to use in obtaining the broadband echo signals from fish schools in relation to the identification of fish species. The broadening of bandwidth was achieved by attaching double acoustic matching layers on the front face of a Tonpilz transducer consisted of an aluminum head, a piezoelectric ring, a brass tail and to evaluate the performance characteristics, such as the transmitting voltage response(TVR) of transducers. The constructed transducers were tested experimentally and numerically by changing the parameters such as impedances and thicknesses of the head, tail and matching layers, in the water tank. Also, the developed transducer was excited by a chirp signal and the received chirp waveforms were analyzed. According to the measured TVR results, the available 3 dB bandwidth of the transducer with double matching layers of an $Al_O_3/epoxy$ composite of 7 mm thick and a polyurethane window of 18 mm thick was 7.3 kHz with a center frequency of 38.8 kHz, and the maximum and the minimum values of the TVR in this frequency region were 135.7 dB and 132.7 dB re $1\;{\mu}Pa/V$ at 1 m, respectively. Also, the available 3 dB bandwidth of the transducer with double matching layers of an $Al_O_3/epoxy$ composite of 11 mm thick and a polyurethane window of 15 mm thick was 6.2 kHz with a center frequency of 38.6 kHz, and the maximum TVR value in the frequency region was 136.3 dB re $1\;{\mu}Pa/V$ at 1 m. Reasonable agreement between the experimental results and the numerical results for the TVR of the developed transducers was achieved. The frequency dependant characteristics of experimentally observed chirp signals closely matched to the measured TVR results. These results suggest that there is potential for increasing the bandwidth by varying other parameters in the transducer design and the material of the acoustic matching layers.

  • PDF