Performance Analysis of Web Service Middleware based on SOAP/RESTFUL (SOAP/RESTFUL 기반 웹 서비스 미들웨어 성능분석)

  • Song, Byung-Kwen
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.146-151
    • /
    • 2014
  • The Smart Grid provide a lot of additional service between ICT(Information Communication Technology) and fusion service. The smart grid using various protocol need to use independent middleware system for exchanging information data. The application system of Smart Grid is exchanging information on the almost All-IP system. The current All-IP middleware system consist of SOAP and RESTful. This paper analysis SOAP and RESTful. This result make use of building Smart Grid System.

A Study on the Implementation of High-Speed Hybrid MAC for Smart Grid Application (스마트 그리드 응용에 적합한 고속Hybrid MAC 구현에 관한 연구)

  • Kwon, Tai-Gil;Kim, Yong-Sung;Cho, Jin-Woong;Hong, Dae-Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.1
    • /
    • pp.73-81
    • /
    • 2014
  • In this paper, high-speed Hybrid MAC (Medium Access Control layer) implementation suitable for smart grid applications is researched. MB-OFDM (Multi-Band Orthogonal Frequency Division Multiplexing) is considered for high-speed communication method in smart grid application. In this paper, the MAC adopts the distributed network managing method. Also, the MB-OFDM merit of high-speed transfer rate of up to 480Mbps must be supported. Hence, this paper presents an efficient hardware-software integration (co-design) method in order to realize a high- speed transmission, and a realizing method of distribution network. Finally, MAC performance and reliability based on MB-OFDM PHY (PHYsical layer) are confirmed through simulation and emulation.

A Study on Determining the Size of the Interface Inductor for Grid-Connected Micro-Sources (Micro-Source의 계통 연계용 인덕터 크기 선정에 관한 연구)

  • Son, Kwang-Myung;Kim, Young-Seob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.52-58
    • /
    • 2005
  • The concept of the Micro-Grid comprising Micro-Sources supplying both heat and power ranging from several [KW] to 1[MW] to local customers is proposed by CERTS(Consortium for Electric Reliability Technology Solutions). Micro-Sources adopt environmentally friendly and reliable power sources such as Fuel-Cell and Micro-Turbines. Micro-Sources adopt voltage source inverter with AC grid system in order to provide independent real and reactive power control for premium power quality. Thus Micro-Source needs series inductance for interfacing with AC grid system. With this reason, we propose a technique that can decide the optimal size of the inductor for effective transfer of the power into the grid.

EFFECTS OF GRID SPACER WITH MIXING VANE ON ENTRAINMENTS AND DEPOSITIONS IN TWO-PHASE ANNULAR FLOWS

  • KAWAHARA, AKIMARO;SADATOMI, MICHIO;IMAMURA, SHOGO;SHIMOHARAI, YUTA;HIRAKATA, YUDAI;ENDO, MASATO
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.389-397
    • /
    • 2015
  • The effects of mixing vanes (MVs) attached to a grid spacer on the characteristics of air-water annular flows were experimentally investigated. To know the effects, a grid spacer with or without MV was inserted in a vertical circular pipe of 16-mm internal diameter. For three cases (i.e., no spacer, spacer without MV, and spacer with MV), the liquid film thickness, liquid entrainment fraction, and deposition rate were measured by the constant current method, single liquid film extraction method, and double liquid film extraction method, respectively. The MVs significantly promote the re-deposition of liquid droplets in the gas core flow into the liquid film on the channel walls. The deposition mass transfer coefficient is three times higher for the spacer with MV than for the spacer without MV, even for cases 0.3-m downstream from the spacer. The liquid film thickness becomes thicker upstream and downstream for the spacer with MV, compared with the thickness for the spacer without MV and for the case with no spacer.

A Study on Technology Transfer in IT Industry (IT 산업계의 기술이전에 관한 연구)

  • Sung, Tae-Kyung
    • Management & Information Systems Review
    • /
    • v.28 no.3
    • /
    • pp.45-68
    • /
    • 2009
  • The Korean government is actively pursuing an ambitious IT strategy to establish Korea as one of the leaders in the world IT market. To implement the strategy, successful technology transfer from research institutions to market should be achieved. Comprehensive literature identifies sixteen variables affecting the process and results of technology transfer. The research results in four key factors in technology transfer: Communication, Distance, Equivocality, and Motivation. Communication refers to the degree to which a medium is able to efficiently and accurately conveys task-relevant information and media while distance involves both physical and cultural proximity. Equivocality refers to the degree of concreteness of technology to be transferred while motivation involves incentives for and the recognition of the importance of technology transfer activities. Further analysis shows that there are four distinctive clusters and they show very contrasting characteristics in terms of four key factors. The careful mapping of the four clusters on the four key factors show very informative technology transfer patterns, the Technology Transfer Grid.

  • PDF

Numerical analysis of heat transfer for architectural structure composed of multiple materials in ISO10211 (복합재질로 구성된 건축 구조체의 열전달 수치해석을 위한 ISI10211모델계산)

  • Lee, Juhee;Park, JiHo;Lee, YongJun
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.159-166
    • /
    • 2016
  • Purpose: The architectural structures in the engineering field include more than one material, and the heat transfer through these multiple materials becomes complicated. More or less, the analytic solutions obtained by the hand calculation can provide the limited information of heat transfer phenomena. However, the engineers have generally been forced to obtain reliable results than those of the hand calculation. The numerical calculation such as a finite volume methods with the unstructured grid system is only the suitable means of the analysis for the complex and arbitrary domains that consists of multiple materials. In this study, a new numerical code is developed to provide temperature distributions in the multiple material domains, and the results of this code are compared with the validation cases in ISO10211. Method: Finite volume methods with an unstructured grid is employed. In terms of numerical methods, the heat transfer conduction coefficient is not defined on the surface of the cell between different material cells. The heat transfer coefficient is properly defined to accurately mimic the heat transfer through the surface. The boundary conditions of heat flux considering radiation or heat convection are also developed. Result: The comparison between numerical results and ISO 10211 cases. We are confirmed that the numerical method provides the proper temperature distributions, and the heat transfer equation and its boundary conditions are developed properly.

An Optimization Design of the Diode Clamped Multi-Level Converter for Coaxial Inductive Power Transfer on the Low Voltage DC Micro-grid

  • Pairindra, Worapong;Khomfoi, Surin
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.333-344
    • /
    • 2018
  • This proposed paper aims for the high efficiency contactless power transfer in household dc power distribution. A 300 W five-level diode clamped multi-level converter with 300 Vdc input dc link bus is employed for the power transferring task and the output voltage range is controlled at 48 Vdc. The inner and outer solenoid coils are used for inductive power transfer (IPT) transformer with the 200 kHz switching frequency for designed power density. Therefore, to achieve the converter efficiency above 95%, the LLC series resonant with fundamental harmonic analysis (FHA) and the calculated switching angles are used as an optimized tool for designing the system resonant tank. The validations of this approached topology are illustrated in both MATLAB/Simulink simulation and implementation.

A Design and Implementation of Job Management Service on TIGRIS (TIGRIS 상에서 작업 관리 서비스의 설계 및 구축)

  • Myung, Hun Joo;Lee, Pilwoo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.582-585
    • /
    • 2007
  • Grid is infrastructure that connect distrubuted resources or ones in various organizations and enable user to use them as a virtual enormous resources. Traditionally, Job Management Service in Grid plays a role of job submission window and job monitoring and a important part of Grid Services with Resource Information Service and Data Transfer & Management Service. In this paper, we describe a design and implementation of Job Managment Service on TIGRIS.

  • PDF

A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

  • Jung, Hong-Ju;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1988-1994
    • /
    • 2014
  • In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

LINEAR INSTABILITY ANALYSIS OF A WATER SHEET TRAILING FROM A WET SPACER GRID IN A ROD BUNDLE

  • Kang, Han-Ok;Cheung, Fan-Bill
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.895-910
    • /
    • 2013
  • The reflood test data from the rod bundle heat transfer (RBHT) test facility showed that the grids in the upper portion of the rod bundle could become wet well before the arrival of the quench front and that the sizes of liquid droplets downstream of a wet grid could not be predicted by the droplet breakup models for a dry grid. To investigate the water droplet generation from a wet grid spacer, a viscous linear temporal instability model of the water sheet issuing from the trailing edge of the grid with the surrounding steam up-flow is developed in this study. The Orr-Sommerfeld equations along with appropriate boundary conditions for the flow are solved using Chebyshev series expansions and the Tau-Galerkin projection method. The effects of several physical parameters on the water sheet oscillation are studied by determining the variation of the temporal growth rate with the wavenumber. It is found that a larger relative steam velocity to water velocity has a tendency to destabilize the water sheet with increased dynamic pressure. On the other hand, a larger ratio of steam boundary layer to the half water sheet thickness has a stabilizing effect on the water sheet oscillation. Droplet diameters downstream of the spacer grid predicted by the present model are found to compare reasonably well with the data obtained at the RBHT test facility as well as with other data recently reported in the literature.