• 제목/요약/키워드: Technology Leakage

검색결과 1,690건 처리시간 0.032초

치과용 이동형 방사선장치의 선량평가 (Evaluation of Radiation Doses of Dental Portable Equipment)

  • 박훈희;강병삼
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.445-450
    • /
    • 2018
  • We aim to evaluate safety of radiation by measuring leakage dose and patient(phantom) incident dose of ZEN-PX II dental portable equipment developed by G company. Measurement for leakage dose of equipment is conducted on the top, at the bottom, on the left, on the right and at the back. Dose measurement incident on the subject with the area dosimeter when using the phantom and measurement the leakage dose of equipment when using the phantom are evaluated. Comparing the right with the highest leakage dose as a 0 cm, 25 cm, 50 cm, 75 cm and 100 cm dose measurement at the measurement height of 100 cm, 64.2 uR was reduced to 47.3 uR in the senser mode 0.32sec. Even in film mode it was measured at 414.4 uR and about 27% lower at 162.6 uR. As the result of this study, when the irradiation time is 2 sec the right side dose is 290.5 uR and sensor mode is 0.32 sec the right side dose is 64.2 uR.

파워스펙트럼 분석을 이용한 누수탐지 모니터링 시뮬레이션 (Water Leakage Detection Monitoring Simulation using Power Spectrum Analysis)

  • 정경용
    • 한국콘텐츠학회논문지
    • /
    • 제13권1호
    • /
    • pp.48-54
    • /
    • 2013
  • IT융합기술의 발전에 따라 누수탐지를 위한 인프라스트럭처가 구축되면서, 파손된 관로의 위치 및 규모의 파악 기술이 부각되고 있다. 또한 상수도 시설의 누수로 인한 수자원의 고갈 때문에 효율적으로 누수를 탐지할 수 있는 방법이 시급하다. 본 논문에서는 파워스펙트럼 분석을 이용한 누수탐지 모니터링 시뮬레이션을 제안하였다. 제안한 누수탐지 모니터링 시뮬레이션에서 반사파 파형을 측정한다. 수집된 반사파 파형으로부터 변화율을 계산한다. 그리고 고속 퓨리에 변환을 이용한 파워 스펙트럼 분석은 누수의 크기와 반사파 파형의 상관관계를 평가한다. 이를 시뮬레이션의 논리적 타당성과 유효성을 검증하기 위해 실험적인 적용을 시도하고자 한다. 따라서 실시간 누수탐지를 제공하여 효율적인 관리에 대한 만족도와 서비스의 질을 향상시켰다.

위상차를 이용한 저항성 누설전류 측정 알고리즘을 적용한 온라인 전기안전 감시시스템의 개발 및 성능시험 (Development and Performance Test of Online Electrical Safety Monitoring System Applying an Algorithm to Measure Resistive Leakage Currents using Phase Differences)

  • 유정현;김희식;정용욱
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.27-32
    • /
    • 2018
  • Nowadays, to prevent electrical accidents in Korea, inspectors directly performed checking general electrical facilities as a cycle from every one to three years. It is difficult to presuppose an omen because intact conditions of electrical equipments are not kept at the time of inspection. In this paper, in order to ensure effectiveness of an online basis electric inspection, we developed an electrical safety IoT system using LoRa communication technology to enable monitoring mainly electrical safety components such as overcurrent, overvoltage, resistive leakage current, and power. Then we proposed a method for verifying performances of the prosed electrical safety IoT system. Resistive leakage currents are calculated by using difference of phase between voltages and currents. We verified that average errors are 0.97%, which reference goal is ${\pm}5%$ for a device, through reliability test according to conditions. Results of this research can be used as basic study materials to develop technologies for measuring three phase leakage current and for implementing public electrical safety. platform.

흙댐의 누수구역 판별을 위한 온도 모니터링 자료의 해석 (Analysis of temperature monitoring data for leakage detection of earth dam)

  • 오석훈;서백수
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.39-45
    • /
    • 2008
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

Leakage Current Energy Harvesting Application in a Photovoltaic (PV) Panel Transformerless Inverter System

  • Khan, Md. Noman Habib;Khan, Sheroz
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권4호
    • /
    • pp.190-194
    • /
    • 2017
  • Present-day solar panels incorporate inverters as their core components. Switching devices driven by specialized power controllers are operated in a transformerless inverter topology. However, some challenges associated with this configuration include the absence of isolation, causing leakage currents to flow through various components toward ground. This inevitably causes power losses, often being also the primary reason for the power inverters' analog equipment failure. In this paper, various aspects of the leakage currents are studied using different circuit analysis methods. The primary objective is to convert the leakage current energy into a usable DC voltage source. The research is focused on harvesting the leakage currents for producing circa 1.1 V, derived from recently developed rectifier circuits, and driving a $200{\Omega}$ load with a power in the milliwatt range. Even though the output voltage level is low, the harvested power could be used for charging small batteries or capacitors, even driving light loads.

Ultrathin-body MOSFET의 leakage current와 관련한 SiGe alloy substrate의 특성 평가

  • 이동헌;강영호
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제3회(2014년)
    • /
    • pp.415-419
    • /
    • 2014
  • 나노스케일 MOSFET에서 leakage current는 중요한 이슈로서 $Si_{1-x}Ge_x$ alloy를 substrate로 사용할 경우 leakage current에 어떤 영향을 미칠 것인지 시뮬레이션을 통하여 알아보았다. $Si_{1-x}Ge_x$ alloy에서 Ge의 비율이 증가할수록 유효질량이 작아졌으나 conduction band minimum의 위치는 Si에 비해 상승하였다. 이로 인해 tunneling 확률이 증가하여 $Si_{1-x}Ge_x$ alloy를 substrate로 사용할 경우 leakage current를 더욱 증가시키게 되었다.

  • PDF

LNG 탱크에서 천연가스 유출시 얕은 기초 주변 지반거동의 수치해석적 분석 (Numerical Analysis of Behavior of Ground Near LNG Tank Foundation Under Scenario of LNG Leakage)

  • 김정수;김영석;이기철;김동욱
    • 한국지반신소재학회논문집
    • /
    • 제17권4호
    • /
    • pp.81-92
    • /
    • 2018
  • 최근 천연가스에 대한 수요가 높아지면서 이를 저장하기 위한 LNG 탱크의 건설이 증가하고 있다. LNG는 효율적인 저장을 위해 극저온의 유체로 액화되므로, LNG 탱크의 결함으로 인한 LNG 유출은 막대한 피해를 야기할 수 있다. 많은 연구자들이 다양한 LNG 유출 상황에 대하여 발생가능 한 피해 영향을 평가하였으나, 극저온의 LNG 유체가 유출될 경우 LNG 탱크를 지지하고 있는 지반에 미치는 영향에 대한 연구는 제한적이다. 따라서 본 논문에서는 LNG 탱크 및 지반의 다양한 조건을 고려하여 LNG 유출에 따른 동결 지반의 역학적, 열적 거동 변화에 대한 연구를 수행하였다. 유출 시나리오의 구현을 위해 수치해석을 수행하였으며, 상재하중, 온도 경계조건, 흙의 동결 민감성 변화에 따른 지반과 기초구조물 거동을 조사하고자 하였다. 이를 통해 LNG 유출 이후 지반의 단기 및 장기 온도변화를 평가하였으며, 지반 동결에 따른 간극 및 연직변위 변화를 분석하였다.

Prediction of Flashover and Pollution Severity of High Voltage Transmission Line Insulators Using Wavelet Transform and Fuzzy C-Means Approach

  • Narayanan, V. Jayaprakash;Sivakumar, M.;Karpagavani, K.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1677-1685
    • /
    • 2014
  • Major problem in the high voltage power transmission line is the flashover due to polluted ceramic insulators which leads to failure of equipments, catastrophic fires and power outages. This paper deals with the development of a better diagnostic tool to predict the flashover and pollution severity of power transmission line insulators based on the wavelet transform and fuzzy c-means clustering approach. In this work, laboratory experiments were carried out on power transmission line porcelain insulators under AC voltages at different pollution conditions and corresponding leakage current patterns were measured. Discrete wavelet transform technique is employed to extract important features of leakage current signals. Variation of leakage current magnitude and distortion ratio at different pollution levels were analyzed. Fuzzy c-means algorithm is used to cluster the extracted features of the leakage current data. Test results clearly show that the flashover and pollution severity of power transmission line insulators can be effectively realized through fuzzy clustering technique and it will be useful to carry out preventive maintenance work.

Calculation of Leakage Inductance of Integrated Magnetic Transformer with Separated Secondary Winding Used in ZVS PSFB Converter

  • Tian, Jiashen;Zhang, Yiming;Ren, Xiguo;Wang, Xuhong;Tao, Haijun
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.644-651
    • /
    • 2016
  • A novel zero voltage switching (ZVS) phase shift full bridge (PSFB) converter used in geophysical exploration is proposed in this paper. To extend the ZVS ranges and increase power density of the converter, external inductor acting as leakage inductance is applied and integrated into the integrated magnetic (IM) transformer with separated secondary winding. Moreover, the loss of ZVS PSFB converter is also decreased. Besides, the analysis and accurate prediction methodology of the leakage inductance of the IM transformer are proposed, which are based on magnetic energy and Lebedev. Finally, to verify the accuracy of analysis and methodology, the experimental and finite element analysis (FEA) results of IM transformer and 40 kW converter prototypes are given.

The Error Analysis of Leak Measurement for Pneumatic Cylinder Using Isothermal Chamber

  • Jang, Ji-Seong;Ji, Sang-Won;Kagawa, Toshiharu
    • 유공압시스템학회논문집
    • /
    • 제5권1호
    • /
    • pp.6-12
    • /
    • 2008
  • ISO pneumatic cylinder reliability test requires air leakage measurement. Air cylinder has many parts and the leakage shall be measured before, during and after endurance test, and, the leakage should smaller than the specified value. The existing measurement method needs complex operation and the calibration of leak detector, and, has to separate the testing cylinder from endurance test device, which causes the change of contact condition of seal in the cylinder. Therefore, it is hard to evaluate the air leakage during endurance test, and guarantee the reliability of the conventional measurement method. In this paper, a new method for air leakage measurement using isothermal chamber, which does not requires calibration or temperature compensation, and, can measure air leakage accurately with quite simple operations, is proposed. As a result, reliability of air leakage measurement can be improved because the proposed method does not have to separate the testing cylinder from the endurance test device for air leakage measurement. The effectiveness of the proposed method is proved by error analysis of leak measurement from experimental result.

  • PDF