• Title/Summary/Keyword: Technical equipment

Search Result 755, Processing Time 0.029 seconds

Empirical Study for the Appraisal System of Execution Capacity using Correlation Analysis (상관관계분석을 이용한 시공능력평가 제도의 실증적 고찰)

  • Jeong, Keun Chae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.2
    • /
    • pp.3-14
    • /
    • 2018
  • The system to appraise the execution capabilities of construction companies had been began as the Construction Contract Restriction System in 1958, was changed as the Construction Subcontract Restriction System in 1961, and finally has been operated as the Appraisal and Public Announcement of Execution Capacity (APAEC) from 1996. The APAEC system has been utilized as a firm and unique tool for assessing the execution capacities of construction companies despite many problems and continuous system changes. In spite of numerous studies to improve the APAEC system, however, efforts to analyze the system from the empirical point of view were insufficient. In this study, we analyze the status of APAEC system through analyzing correlations among assessment results of the APAEC, earned values of construction works, construction management performance indexes, and macroeconomic indexes for the past 10 years from 2007 to 2016. As a result of the analysis, it was found that Appraisal Value of Execution Capacity (AVEC) is excessively inflated in engineering and landscaping areas compared to Earned Value of Construction Work (EVCW) and the correlations between the AVECs and EVECs are not high in the areas of engineering, industrial equipment, and landscaping. In addition, technical appraisal values are excessively inflated in engineering and landscaping areas and correlations between AVEC and its components are high in the areas of engineering & building, industrial equipment, and large companies, but low in the areas of engineering, building, landscaping, and small and medium companies. Finally, the concentration of the AVEC is intensifying more and more and the concentration deteriorates construction management performance indexes and macroeconomic indexes. If we continuously improve the APAEC system based on the implications derived in this study, the APAEC system will be able to maintain it's position of a firm and unique means to access the execution capacities of construction companies.

Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT (영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교)

  • Kim, Woo-Hyun;Jung, Woo-Young;Lee, Ju-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: Nowadays in the nuclear medicine, many studies and efforts are being made to reduce the scan time, as well as the waiting time to be needed to execute exams after injection of radionuclide medicines. Several methods are being used in clinic, such as developing new radionuclide compounds that enable to be absorbed into target organs more quickly and reducing acquisition scan time by increase the number of Gamma Camera detectors to examine. Each medical equipment manufacturer has improved the imaging process techniques to reduce scan time. In this paper, we tried to analyze the difference of image quality between FBP, 3D OSEM reconstruction methods that commercialized and being clinically applied, and Astonish reconstruction method (A kind of Iterative fast reconstruction method of Philips), also difference of image quality on scan time. Material and Methods: We investigated in 32 patients that examined the Bone SPECT from June to July 2008 at department of nuclear medicine, ASAN Medical Center in Seoul. 40sec/frame and 20sec/frame images were acquired that using Philips‘ PRECEDENCE 16 Gamma Camera and then reconstructed those images by using the Astonish (Philips’ Reconstruction Method), 3D OSEM and FBP methods. The blinded test was performed to the clinical interpreting physicians with all images analyzed by each reconstruction method for qualitative analysis. And we analyzed target to non target ratio by draws lesions as the center of disease for quantitative analysis. At this time, each image was analyzed with same location and size of ROI. Results: In a qualitative analysis, there was no significant difference by acquisition time changes in image quality. In a quantitative analysis, the images reconstructed Astonish method showed good quality due to better sharpness and distinguish sharply between lesions and peripheral lesions. After measuring each mean value and standard deviation value of target to non target ratio with 40 sec/frame and 20sec/frame images, those values are Astonish (40 sec-$13.91{\pm}5.62$ : 20 sec-$13.88{\pm}5.92$), 3D OSEM (40 sec-$10.60{\pm}3.55$ : 20 sec-$10.55{\pm}3.64$), FBP (40 sec-$8.30{\pm}4.44$ : 20 sec-$8.19{\pm}4.20$). We analyzed target to non target ratio from 20 sec and 40 sec images. And we analyzed the result, In Astonish (t=0.16, p=0.872), 3D OSEM (t=0.51, p=0.610), FBP (t=0.73, p=0.469) methods, there was no significant difference statistically by acquisition time change in image quality. But FBP indicates no statistical differences while some images indicate difference between 40 sec/frame and 20 sec/frame images by various factors. Conclusions: In the circumstance, try to find a solution to reduce nuclear medicine scan time, the development of nuclear medicine equipment hardware has decreased while software has marched forward at a relentless. Due to development of computer hardware, the image reconstruction time was reduced and the expanded capacity to restore enables iterative methods that couldn't be performed before due to technical limits. As imaging process technique developed, it reduced scan time and we could observe that image quality keep similar level. While keeping exam quality and reducing scan time can induce the reduction of patient's pain and sensory waiting time, also accessibility of nuclear medicine exam will be improved and it provide better service to patients and clinical physician who order exams. Consequently, those things make the image of department of nuclear medicine be improved. Concurrent Imaging - A new function that setting up each image acquisition parameter and enables to acquire images simultaneously with various parameters to once examine.

  • PDF

A Study on Survey of Non Face to Face Realtime Education Focused on Firefighter in COVID-19 (코로나19 상황에서 소방공무원의 비대면 실시간 교육에 관한 의식조사연구)

  • Park, Jin Chan;Baek, Min Ho
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.722-732
    • /
    • 2021
  • Purpose: Due to the coronavirus infection-19 (COVID) pendemics, all educational institutions were required to provide full non-face-to-face real-time education, and fire officials were required to provide fire-fighting education by applying non-face-to-face education. In this difficult situation, the National Fire Service Academy tries to find the direction of the non-face-to-face real-time education and suggest ways to improve it through a survey of the status of non-face-to-face real-time education conducted by the NFSA to fire officials. Method: A survey was conducted on fire officials under the theme of "Consciousness Survey for Improving the Quality and Specialization of Non-face-to-face Real-Time Remote Education" and an in-depth analysis was conducted based on the results. Result & Conclusion: First, professors or educational operators shall actively utilize remote education programs suitable for educational characteristics by utilizing various programs. Second, a dedicated notebook for non-face-to-face training should be provided to provide an educational environment where all learners can participate in the training without difficulty. Third, in the case of education and training that requires the use of equipment due to the nature of fire officials' education and training, it is necessary to consider it as a non-face-to-face training place by arranging educational equipment at each fire station. Fourth, it is hard to expect a satisfactory educational effect to cope with practical education with theoretical education. Therefore, facilities and programs that enable non-face-to-face real-time hands-on training should be developed. It is worth considering the proper combination of face-to-face education while maintaining the social distance as much as possible until such non-face-to-face training is possible. Fifth, non-face-to-face education is considered to have high eye fatigue due to the light and electromagnetic waves of the computer screen, and as time goes by, the concentration level decreases. Therefore, it is necessary to form an education time to reduce the eye fatigue of learners and increase concentration through proper class and rest time. Finally, professors should operate a learner participation-oriented education that allows professors and learners to interact rather than one-sided knowledge transfer education. In addition, technical problems of non-face-to-face remote education should be thoroughly prepared through preliminary system checks to ensure that education is not disrupted.

Study on the Recognition of Forest-Official's and Stakeholders's Toward Improvement of Tree Cutting Permit System (입목벌채 허가제도 개선에 대한 벌채허가 담당자와 벌채 실행자의 인식조사)

  • Park, Kyung-Seok;Lee, Seong-Youn;Bae, Sang-Won;Kim, Min-Hee;Kim, Hyun-Sig;Baik, Kyung-Soo;An, Ki-Wan
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.2
    • /
    • pp.292-304
    • /
    • 2011
  • The purpose of this study is to draw institutional implications for tree cutting permit system improvement in comparison with Korea and foreign countries (German, Japan). A survey about recognition of cutting system and cutting-invigorating factors for two groups in charge of work for cutting permit (forest-official) and cutting operation (forest owner, tree butcher, forestry association, and forestry corporation) was carried out. The survey provides basic information which is necessary to improve current cutting system. The result of analysis about both German and Japan's cutting system show that clear cutting area to hinder function of forests tends to decrease and flexible final age of maturity considering condition of regional forest not uniform cutting age were applied. As a result of German and Japan's cutting system review flexible cutting system on regional characteristics is used to manage for the purpose of forest regeneration. The survey result about awareness and invigorating factors of cutting system represents that only public official group said final age of pine tree (3.13) and cedar (3.05) was proper and final age of other species of trees should have shortened. In matters of cutover area, current standard is less than 5ha per a felling area and the largest total area limit is 30 ha, only tree butcher, forestry corporation said cutover area must expand. Invigorating factors of current cutting system are reinforcement of cutover area, facility support, enrichment of technical training, increase of equipment support, simplification of administrative procedures, and provision of various benefits. The reinforcement of technical training among them especially represents the statistical significance of the participants' differential recognition.

A Study on Status of Utilization and The Related Factors of Primary Medical Care in a Rural Area (일부 농촌지역의 일차의료이용실태와 그 관련요인에 관한 연구)

  • Wie, Cha-Hyung
    • Journal of agricultural medicine and community health
    • /
    • v.20 no.2
    • /
    • pp.157-168
    • /
    • 1995
  • This study was carried out, through analyzing the annual reports(year of 1973-1993) on health status of Su Dong-Myun, and specific survey data of 332 households(Su Dong-Myun 209, Byul Nae-Myun 123), located in Nam Yang Ju-Si, Kyung Gi-Do, from July 20 to July 31, 1995, to find out more effective means for primary medical care in a rural area. The results were as fellows : 1. Number of population in Su Dong-Myun was 5,419 in 1973, 4,591(the lowest) in 1987 and 5,707 in 1995. In the composition rate of population, "0-14" of age group showed markedly decreasing tendency from 43.1% in 1975, to 19.1% in 1995, however "65 and over" markedly in creasing tendency form 5.3% in 1975 to 9.8% in 1995. 2. Annual utilization rate per 1,000 inhabitants in Su Dong-Myun showed markedly increasing tendency from 1973 to 1977 such as 343 in 1973, 540 in 1975, 900 in 1977. However, since 1979, the rate showed rapidly decreasing tendency, such as 846 in 1979, 519 in 1985, 190 in 1991 and 1993. 3. The morbid household rate per year was 53.6% of respondents and the rate per 15 days was 48.2%. In disease classification rate of morbid household per year, Arthralgia & Neuralgia was the highest rate(33.9%) and gastro-intestinal disorder(19.3%), Cough(11,9%), Hypertension(7.8%), Accident(3.2%) in next order. 4. In the utilizing facilities for Primary Medical Care, Medical facilities was showed the highest rate(58.1% of respondents) and Pharmacy and Drug Shp(33.1%), Tradition Method(4.0%) in next order. In the Medical facilities, General private clinic was showed the highest rate(34.3%) and specific private Clinic(22.3%), Hospital(19.0%), Health (Sub)center(16.3%), Nurse practitioner (3.3%), Oriental hospital and clinic(2.7%) in next order. 5. Experience rate, utilizing health subcenter was 51.8% of the respondents, and it was 55.0% in Su Dong-Myun and 46.3% in Byul Nae-Myun. In utilization times of health subcenter, times-rate showed next orders such as 1-2 times/6months(31.6%), 1-2 times/year (22.1%), 1-2 times/months(19.2%), 1-2 times/3months(15.6%). 6. In objectives, visiting Health Subcenter, Medical Care was the highest rate(59.8% of the respondents) and health control(23.3%) was in next order. In Medical Care, Primary Care by general physician was higher rate(51.1%) almost all. In the Health control, Immunization too was high rate(18.0%) in health control activities. 7. The reasons rate, utilizing health subcenter showed next order, such as distance to Medical facilities(33.0% of the respondents), Medical Cost(28.1%), Simple process of consultation (10.8%), Effectiveness of cure(7.6%), Function of primary medical care(7.0%) and Attitude of physician(6.5%). 8. In the affecting factors to utilization of primary medical facilities, medical needs was showed the highest rate(29.5% of the respondents) and medical cost(15.4%), distance to medical facilities(14.2%), traffic vehicle(14.2%) and farm work(6.9%) in next order. 9. In the priority between 'daily farm work,' and 'primary medical care', only 46.4% of respondents answered that primary health care is more important than the daily farm work The 22.6% of respondents answered 'daily farm work', and the 12.3% answered 'the equal of the both'. 10. In the criterion of medical facilities choice, medical knowledge and technical quality was showed the highest rate(56.3%), distance or time to medical facilities(10.9%), sincerity and kindness of physician(9.4%), medical cost(8.7%) and traffic vehicle(6.5%) in next order 11. In the advise for improvement of health subcenter function, the 36.1% of respondents answered that 'enforcement of medical personnel and equipment' was required, and then 'improved medical technology'(25.5%), 'good attitude of physician'(14.9%), 'improved medical system'(13.3%), 'enforced drug'(6.7%) in next order. 12. The study on affecting factors to utilization of primary medical facilities was very difficult subject to systematize the analyzed results, due to a prejudice of protocol planner, surveyer and respondent, and variety and overlapping of subject matter.

  • PDF

A Study on Integrated Logistic Support (통합병참지원에 관한 연구)

  • 나명환;김종걸;이낙영;권영일;홍연웅;전영록
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2001.06a
    • /
    • pp.277-278
    • /
    • 2001
  • The successful operation of a product In service depends upon the effective provision of logistic support in order to achieve and maintain the required levels of performance and customer satisfaction. Logistic support encompasses the activities and facilities required to maintain a product (hardware and software) in service. Logistic support covers maintenance, manpower and personnel, training, spares, technical documentation and packaging handling, storage and transportation and support facilities.The cost of logistic support is often a major contributor to the Life Cycle Cost (LCC) of a product and increasingly customers are making purchase decisions based on lifecycle cost rather than initial purchase price alone. Logistic support considerations can therefore have a major impact on product sales by ensuring that the product can be easily maintained at a reasonable cost and that all the necessary facilities have been provided to fully support the product in the field so that it meets the required availability. Quantification of support costs allows the manufacturer to estimate the support cost elements and evaluate possible warranty costs. This reduces risk and allows support costs to be set at competitive rates.Integrated Logistic Support (ILS) is a management method by which all the logistic support services required by a customer can be brought together in a structured way and In harmony with a product. In essence the application of ILS:- causes logistic support considerations to be integrated into product design;- develops logistic support arrangements that are consistently related to the design and to each other;- provides the necessary logistic support at the beginning and during customer use at optimum cost.The method by which ILS achieves much of the above is through the application of Logistic Support Analysis (LSA). This is a series of support analysis tasks that are performed throughout the design process in order to ensure that the product can be supported efficiently In accordance with the requirements of the customer.The successful application of ILS will result in a number of customer and supplier benefits. These should include some or all of the following:- greater product uptime;- fewer product modifications due to supportability deficiencies and hence less supplier rework;- better adherence to production schedules in process plants through reduced maintenance, better support;- lower supplier product costs;- Bower customer support costs;- better visibility of support costs;- reduced product LCC;- a better and more saleable product;- Improved safety;- increased overall customer satisfaction;- increased product purchases;- potential for purchase or upgrade of the product sooner through customer savings on support of current product.ILS should be an integral part of the total management process with an on-going improvement activity using monitoring of achieved performance to tailor existing support and influence future design activities. For many years, ILS was predominantly applied to military procurement, primarily using standards generated by the US Government Department of Defense (DoD). The military standards refer to specialized government infrastructures and are too complex for commercial application. The methods and benefits of ILS, however, have potential for much wider application in commercial and civilian use. The concept of ILS is simple and depends on a structured procedure that assures that logistic aspects are fully considered throughout the design and development phases of a product, in close cooperation with the designers. The ability to effectively support the product is given equal weight to performance and is fully considered in relation to its cost.The application of ILS provides improvements in availability, maintenance support and longterm 3ogistic cost savings. Logistic costs are significant through the life of a system and can often amount to many times the initial purchase cost of the system.This study provides guidance on the minimum activities necessary to Implement effective ILS for a wide range of commercial suppliers. The guide supplements IEC60106-4, Guide on maintainability of equipment Part 4: Section Eight maintenance and maintenance support planning, which emphasizes the maintenance aspects of the support requirements and refers to other existing standards where appropriate. The use of Reliability and Maintainability studies is also mentioned in this study, as R&M is an important interface area to ILS.

  • PDF

Research of z-axis geometric dose efficiency in multi-detector computed tomography (MDCT 장치의 z-축 기하학적 선량효율에 관한 연구)

  • Kim, You-Hyun;Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.167-175
    • /
    • 2006
  • With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows ; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. 4. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for image reconstruction. As a conclusion, for reduction of patient radiation dose delivered from CT examination we are particularly concerned with dose efficiency of equipment and have to select proper scanning parameters which increase z-axis geometric dose efficiency within the range of preserving optimum clinical information in MDCT examination.

  • PDF

The study of the status of teaching and learning and needs assessment for 'The basis of the Invention Patent' subjects ('발명.특허 기초' 과목의 교수.학습 방법 실태 및 요구 조사 연구)

  • Lee, Chan Joo;Lee, Byung Wook;Kang, Kyoung Kyoon;Im, Yoo Hwa
    • 대한공업교육학회지
    • /
    • v.38 no.1
    • /
    • pp.105-124
    • /
    • 2013
  • This study aims to analyze the teaching and learning methods realities and needs in the subjects 'The basis of the Invention Patent'. To this end, research and analysis of the subjects 'The basis of the Invention Patent' the teacher and take advantage of their current teaching and learning methods, 'The basis of the Invention Patent' subject teachers to recognize the most desirable teaching and learning methods, subjects 'The basis of the Invention Patent' of teaching and learning and the operating requirements of the difficult matters. Survey of 48 schools across the country in high school teachers to teach the subjects 'The basis of the Invention Patent' was conducted, the results of this study are as follows. First, a high percentage of theoretical learning activities, teaching methods, such as 'lectures' and take advantage of the higher percentage. Module was to conduct classes such as 'project', 'lab experiments', 'discussion', 'investigation' by taking advantage of the high proportion of practice learning activities. Second, Higher requirements for the experience and practice of student-centered 'lab experiments', 'project', 'Case Studies', 'field trips' and theory-driven rather than 'lectures'. Third, 'The basis of the Invention Patent' subjects 'Teaching and learning important when operating requirements for the degree' as a whole was highly recognized. in particular, operating requirements for teaching and learning in accordance with the former college of education of education than non-group differences were higher overall response. Fourth, 'The basis of the Invention Patent' subjects 'Teaching and learning difficult when operating your degree' as a whole was highly recognized. In particular, was recognized by difficult questions, such as lack of preparation classes due to excessive work, educational facilities and equipment shortage, lack of prior knowledge about the subject, individual differences of the students considering the difficulties, student's

A Study on Improvement of Test Method of Nuclear Power Plant ESF ACS by applying Regulatory Guide 1.52 (Rev.3) (Reg. Guide 1.52(Rev.3)를 적용한 원전 ESF 공기정화계통 성능시험법 개선 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kae-Woo;Park, Jeong-Seo;Cho, Byoung-Ho;Yoo, Byeang-Jea;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.311-318
    • /
    • 2010
  • U. S. NRC Regulation Guide 1.52 regulating ESF ACS in nuclear power plants has been revised to revision 3. To apply reduction of operability test time, allowance of alternative challenge agents for in-place leak test of HEPA filters, and upgrade of Methyl Iodide penetration acceptance criterion in activated carbon performance test suggested in Reg. Guide 1.52(Rev.3) on Yonggwang units 5 and 6 ESF ACSes, technical feasibility study was carried out with on-site experiments as well as experiments with a lab-scale model. It was confirmed that the moisture in the system returned to the level before the test in 1 or 4 days even though the moisture was removed during the operability test lasting more than 10 hours. Therefore, it is appropriate to perform monthly operability test in 15 minutes just long enough to check the operability of equipment. To change challenge material for in-place HEPA filter leak test, size of aerosol, production rate, and leak detection capability were compared for DOP and PAO. It was concluded that PAO can be substituted for DOP in nuclear power plants. The upgrade of Methyl Iodide penetration acceptance criterion from 0.175 % to 0.5 % in active carbon filter bed deeper than 4 inches was to conform to the change of activated carbon performance test method to ASTM D3803(1989). It was confirmed that Methyl Iodide penetration acceptance criterion of 0.5 % under $30^{\circ}C$, relative humidity 95 % condition was conservatively good enough for testing performance of active carbon insitu. The licence change of Yonggwang units 5 and 6 has been completed based on this study.

Imaging Characteristics of Computed Radiography Systems (CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가)

  • Jung, Ji-Young;Park, Hye-Suk;Cho, Hyo-Min;Lee, Chang-Lae;Nam, So-Ra;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.63-72
    • /
    • 2008
  • With recent advancement of the medical imaging systems and picture archiving and communication system (PACS), installation of digital radiography has been accelerated over past few years. Moreover, Computed Radiography (CR) which was well established for the foundation of digital x-ray imaging systems at low cost was widely used for clinical applications. This study analyzes imaging characteristics for two systems with different pixel sizes through the Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE). In addition, influence of radiation dose to the imaging characteristics was also measured by quantitative assessment. A standard beam quality RQA5 based on an international electro-technical commission (IEC) standard was used to perform the x-ray imaging studies. For the results, the spatial resolution based on MTF at 10% for Agfa CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.9 cycles/mm and 2.8 cycles/mm, respectively. The spatial resolution based on MTF at 10% for Fuji CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.4 cycles/mm and 3.2 cycles/mm, respectively. There was difference in the spatial resolution for $14{\times}17$ inches, although radiation dose does not effect to the MTF. The NPS of the Agfa CR system shows similar results for different pixel size between $100{\mu}m$ for $8{\times}10$ inch I.P and $150{\mu}m$ for $14{\times}17$ inch I.P. For both systems, the results show better NPS for increased radiation dose due to increasing number of photons. DQE of the Agfa CR system for $8{\times}10$ inch I.P and $14{\times}17$ inch I.P resulted in 11% and 8.8% at 1.5 cycles/mm, respectively. Both systems show that the higher level of radiation dose would lead to the worse DQE efficiency. Measuring DQE for multiple factors of imaging characteristics plays very important role in determining efficiency of equipment and reducing radiation dose for the patients. In conclusion, the results of this study could be used as a baseline to optimize imaging systems and their imaging characteristics by measuring MTF, NPS, and DQE for different level of radiation dose.

  • PDF