• 제목/요약/키워드: Technetium-99m

검색결과 120건 처리시간 0.033초

자궁경부암 환자에서의 Lymphoscintigraphy 소견 (Iliopelvic Lymphoscintigraphic Findings in Carcinoma of Uterine Cervix)

  • 임상무;홍성운;박상윤;이제호;이의돈;이경희;박기복;최창운
    • 대한핵의학회지
    • /
    • 제24권2호
    • /
    • pp.286-292
    • /
    • 1990
  • Iliopelvic lymphoscintigraphy was performed to visualize the changes of the lymphatic system using Technetium-99m antimony sulfide colloid in carcinoma of uterine cervix. There were no differences between various indices and clinical stages, but comparison with computed tomographic and postoperative findings, there was meaningful difference in index of decrease and increase, respectively. And lymphoscintigraphy showed by pass way of lymphatic channel in 42 cases (16%) and this suggested the presence of normal shunts of lymphatic channels. Iliopelvic lymphoscintigraphy may be useful for evaluation of lymphatic system in carcinoma of uterine cervix, expecially for screening method.

  • PDF

이중에너지 X선 흡수법을 이용한 골밀도 측정시 99mTc-MDP 투여 전·후 측정값의 변화 (Change in the Measured Value at 99mTc-MDP Administration before and after Bone Density Measurement using the Dual Energy X-ray Absorptiometry)

  • 강용길;원도연;정홍문
    • 한국방사선학회논문지
    • /
    • 제11권1호
    • /
    • pp.43-48
    • /
    • 2017
  • 최근 동위원소를 이용한 뼈 스캔 (Bone Scan)검사 후 골밀도 (BMD; Bone Mineral Density)검사를 당일검사로 병행한 경우 이로 인한 골밀도 측정값에 오차 발생 가능성이 제기되고 있으나 방사성의약품 표지화합물 투여 후 이중에너지 X선을 이용한 골밀도 측정값 변화에 대한 임상적 자료가 미비하여 핵의학 체내검사 후 당일 골다공증 검사의 측정값에 대한 논란의 소지가 있다. 따라서 동위원소 표지화합물인 $^{99m}Tc-MDP$가 골밀도 측정값에 영향을 미치는지 임상적 측면에서 실험하였다. 실험에 참가한 대상자의 평균 나이는 $35.17{\pm}9.45$세로 실험 대상자 17명 중 대사성 질환과 골밀도 측정에 영향을 줄 수 있는 허리뼈 압박골절 및 몸쪽 넓적다리뼈 골절이 있는 자를 제외한 12명 중 정상 골밀도 T-scores>-1.0의 환자 6명을 대상으로 $^{99m}Tc-MDP$ 투여 전 후 측정값을 분석한 결과 허리뼈에서 전 후 각각 평균 $0.975{\pm}0.084g/cm^2$, $0.966{\pm}0.078g/cm^2$으로 $0.009g/cm^2$ 증가, 우측 몸쪽 넓적다리뼈에서는 전 후 각각 평균 $0.909{\pm}0.078g/cm^2$, $0.913{\pm}0.086g/cm^2$으로 $0.004g/cm^2$ 감소, 좌측 몸쪽 넓적다리뼈에서는 각각 평균 $0.887{\pm}0.099g/cm^2$, $0.881{\pm}0.103g/cm^2$으로 $0.007g/cm^2$의 증가를 보여 몸쪽 넓적다리뼈 보다 허리뼈에서 더 큰 골밀도 변화를 보여주었다. 그러나 허리뼈와 몸쪽 넓적다리뼈 전체에서 전 후 변화 평균은 $0.0038{\pm}0.014g/cm^2$으로 골밀도 측정값에 유의한 영향이 없음을 알 수 있으며, 또한 두 실험간 전체 상관계수는 0.987으로 방사성동위원소 표지화합물인 $^{99m}Tc-MDP$ 투여가 골밀도 측정값에 영향을 주지 않았다. 따라서 140 keV의 감마선 에너지를 방출하는 테크네슘 표지화합물을 이용한 뼈 스캔검사 후 골밀도 측정값에 유의한 영향을 미치지 않음을 확인하였다. 그러나 핵의학적 체내검사와 골다공증 검사를 당일로 검사함으로 인한 환자의 피폭을 고려한다면 시간 간격을 두고 검사를 시행하는 것이 좋을 것으로 사료된다.

감마 카메라의 Flood Table에 대한 이해와 적절한 이용 (Comprehension and Appropriate Use of a Flood Table on a Gamma Camera)

  • 김재일;임정진;김진의;김현주
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.29-33
    • /
    • 2011
  • 감마 카메라 안에는 검출기의 감도를 균일하게 해주는 flood table이 내장되어있어 있는데, 우수한 균일성을 유지하기 위해서는 적합한 flood table을 사용하여야 한다. 왜냐면 flood table은 입사된 방사선의 종류와 에너지, 용량에 따라 차이가 나기 때문이다. 그래서 본 논문에서는 적절치 못한 flood table을 사용하였을 때, 영상의 균일성이 어떻게 변화하는지를 알아보겠다. 입사 방사선으로 $^{57}Co$, $^{99m}Tc$, $^{201}Tl$ 370 MBq를 사용하였다. Philips 사의 SkyLight, GE 사의 Infinia 감마 카메라를 사용하여. 각 선원 별로 각각 $^{57}Co$로 교정된 flood table, $^{99m}Tc$으로 교정된 flood table로 보정한 영상을 얻고, 균일성을 보정하지 않은 영상과 비교하였다. 추가적으로 콜리메이터를 장착한 상태에서 데이터를 얻고 내인성 flood table과 외인성 flood table로 보정 해보았다. 이렇게 나온 결과 영상을 가지고 균일도를 평가하였고, 그 값들을 서로 비교하였다. $^{57}Co$를 사용한 경우 보정을 하지 않았을 때 균일도는 9.34% 이고, $^{99m}Tc$ flood table로 보정하였을 때는 5.91%, $^{57}Co$ flood table일 경우 4.9%가 나왔다. $^{201}Tl$을 사용한 경우, 보정하지 않으면 9.81%, $^{99m}Tc$ flood table은 7.03%, $^{57}Co$ flood table은 7.49% 나왔다. $^{99m}Tc$을 사용한 경우, 무보정 시 9.67%, $^{99m}Tc$ flood table은 3.96%, $^{57}Co$ flood table은 5.69% 나왔다. 그리고 내인성 flood table로 보정을 한 경우 6.28% 나왔다. flood table이 입사된 방사선의 종류와 맞지 않는다면 균일도는 변화되는걸 알 수 있었고, 입사된 방사선과 flood table을 교정한 방사선원의 종류가 일치할 때, 감마 카메라의 균일도는 가장 좋음을 알 수 있다. 더불어 내인성, 외인성 시스템처럼 콜리메이터의 유무에 따라 다르게 교정한 flood table에 따라서도 균일도는 변화됨을 알 수 있다. 따라서 감마선을 받아 들이는 상황과 방사선원에 따라 일치한 flood table를 지정하여야 하고, 정기적으로 flood table을 개선시켜 주어야 높은 균일성을 유지 시킬 수 있을 것이다.

  • PDF

Serum levels of interleukin-6 and interleukin-8 as diagnostic markers of acute pyelonephritis in children

  • Mahyar, Abolfazl;Ayazi, Parviz;Maleki, Mohammad Reza;Daneshi-Kohan, Mohammad Mahdi;Sarokhani, Hamid Reza;Hashemi, Hassan Jahani;Talebi-Bakhshayesh, Mousa
    • Clinical and Experimental Pediatrics
    • /
    • 제56권5호
    • /
    • pp.218-223
    • /
    • 2013
  • Purpose: Early diagnosis and treatment of acute pyelonephritis in children is of special importance in order to prevent serious complications. This study was conducted to determine the diagnostic value of serum interleukin (IL)-6 and IL-8 in children with acute pyelonephritis. Methods: Eighty-seven patients between 1 month to 12 years old with urinary tract infection (UTI) were divided into 2 groups based on the result of 99m-technetium dimercapto-succinic acid renal scan: acute pyelonephritis (n=37) and lower UTI (n=50) groups. White blood cell (WBC) count, neutrophil (Neutl) count, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) concentration, platelet count, and serum IL-6 and IL-8 concentrations of both groups were measured and compared. Results: There was a significant difference between two groups regarding WBC count, Neutl count, ESR, and CRP concentration (P<0.05). In addition, the difference between the two groups regarding serum IL-6 and IL-8 concentrations was not significant (IL-6, 60 and 35.4 pg/mL and IL-8, 404 and 617 pg/mL, respectively). The sensitivity and specificity of serum IL-6 and IL-8 for diagnosis of acute pyelonephritis were 73%, 42% and 78%, 32%, respectively. Sensitivity, specificity, negative and positive predictive values of serum IL-6 and IL-8 were less than those of acute phase serum reactants such as CRP. Conclusion: This study showed that there was no significant difference between acute pyelonephritis and lower UTI groups regarding serum IL-6 and IL-8 levels. Therefore, despite confirming results of previous studies, it seems that IL-6 and IL-8 are not suitable markers for differentiating between acute pyelonephritis and lower UTI.

실험적으로 전십자 인대를 단열한 개에서 TPLO의 핵의학적 평가 (Scintigraphic Evaluation of Dogs with Experimentally Transected Cranial Cruciate Ligaments Treated Using Tibial Plateau Leveling Osteotomy)

  • 이재영;김중현;이원국;강성수;배춘식;최석화
    • 한국임상수의학회지
    • /
    • 제22권1호
    • /
    • pp.21-25
    • /
    • 2005
  • This study was performed to assess therapeutic effect of the tibial plateau leveling osteotomy (TPLO) in dogs with experimentally transected cranial cruciate ligaments (CrCL). Nine healthy adult Beagle dogs were transected left CrCL under general anesthesia. The dogs were assigned to TPLO and non-TPLO control groups. The TPLO procedures for correcting the CrCL rupture in the left stifle of dogs were performed under sterile conditions. Before TPLO procedures, all dogs were screened by orthopedic and radiographic examinations. Dogs were lameness free for the previous three months, and when examined at the walk and trot on a hard surface, in a straight line and on a circle. Lateral and craniocaudal radiographs were done to confirm the soundness of the both knee joint in dogs and not detectable lesions were diagnosed. The dogs were intravenously injected with a 10 mci/kg of 99mTechnetium-methylene diphosphonate (99mTc-MDP) under general anesthesia. Scintigraphs were obtained using a large field of view gamma camera equipped a parallel-hole, low-energy about 3 hours after intravenous injection of 99mTc-MDP. Before CrCL transection and 4, 8, and 12 weeks after the procedures, scintigraphy were conducted. Bone uptake of the left stifle joint increased after the procedures in all dogs. When the bone uptake from the TPLO procedure was compared with that of the control, there was a significant difference (p < 0.05). At 12 weeks after the TPLO procedure, the dogs showed normal anatomical posture and gait. It is concluded that TPLO procedure was effective in reconstruct of the stifle joint in dogs with CrCL rupture.

혈관 수술 후 심장 합병증 발생을 예측하기 위한 선별 검사로서 심근 관류 단일 광자 단층촬영의 유용성에 대한 연구 (Myocardial Perfusion SPECT as a Screening Test before Planned Vascular Surgery for Predicting Perioperative Cardiac Complications)

  • 이형채;황윤호;위진홍;전희재;이양행;조광현
    • Journal of Chest Surgery
    • /
    • 제43권1호
    • /
    • pp.25-32
    • /
    • 2010
  • 배경: 혈관질환 환자는 관상동맥질환 및 심장질환을 많이 동반함으로 인하여 혈관 수술 후 잠재되어 있는 심장질환이 악화 또는 유발될 수 있는 가능성이 있다. 이러한 심장질환을 확인하기 위한 검사중 비교적 간단하고 비침습적인 SPECT 촬영에 대한 효용성은 아직 논란이 되고 있다. 본 연구에서는 수술 전 SPECT를 촬영하고, 그 결과에 따른 검사 및 처치들이 혈관 수술 후 심장 합병증 발생에 미치는 임상적인 효과를 평가하고자 한다. 대상 및 방법: 2004년 4월부터 2007년 9월까지 3년 6개월간 본 병원에서 혈관 수술 전 아데노신 부하 Tc-99m 테트로포스민 SPECT를 촬영한 63명의 환자를 대상으로 하였다. 결과: SPECT 촬영 유소견의 심장 합병증 발생 예측에 대한 민감도와 특이도는 각각 41.2%와 52.2%로 비교적 낮게 나왔다. 그러나 비정상적인 SPECT 촬영결과를 보인 환자에게 관상동맥 조영술을 시행하고 관상동맥 병변에 대한 비정상 소견이 있을 때 관상동맥 중재적 시술 및 관상동맥 우회로술 등의 적극적인 처치를 한 경우 심장 합병증의 발생률이 낮은 경향을 보였다. 결론: SPECT 촬영은 혈관수술 후 심장 합병증 발생위험을 예측하기 위한 선별검사로서 효용성이 떨어진다.

부갑상선: 부갑상선 영상에 익숙하지 않은 영상의학과 의사들을 위한 전반적인 검토 (The Parathyroid Gland: An Overall Review of the Hidden Organ for Radiologists)

  • 김수호;신정희;한수연;김해정;김명경
    • 대한영상의학회지
    • /
    • 제85권2호
    • /
    • pp.327-344
    • /
    • 2024
  • 부갑상선은 부갑상선 호르몬(parathyroid hormone; 이하 PTH)을 생성하여 칼슘 대사를 조절하는 작은 내분비선으로 구성되어 있다. 일반적으로 갑상선 뒤에 4개의 부갑상선이 위치해 있으나 개수 또는 위치는 개인차가 있으며 4개보다 많거나 적은 경우들이 있다. 부갑상선 질환은 부갑상선 기능 장애와 관련이 있으며, 부갑상선 자체의 문제 또는 신장질환으로 인한 비정상적인 혈청 칼슘 수치로 인해 발생할 수 있다. 최근 건강검진이 보편화되면서 우연히 비정상적으로 높은 혈청 칼슘 값이 발견되어 PTH 검사, 초음파, 테크네튬-99m 세스타 미비 부갑상선 스캔, 단일광자방출단층촬영/컴퓨터단층촬영(SPECT/CT), 4차원 컴퓨터단층촬영(4D-CT), 그리고 양전자방출단층촬영/컴퓨터단층촬영(PET/CT) 등의 추가적인 검사가 시행된다. 그러나 부갑상선은 여전히 영상의학과 의사에게 익숙하지 않은 기관이다. 이 종설에서 부갑상선의 해부학, 병태생리, 영상 및 임상 소견에 대해 알아보고자 한다.

체외순환도관의 혈액적합성 평가 - 방사선 동위원소(Tc99m) 활성화 혈소판의 생체 내 주입을 이용한 정량분석법의 개발 - (Evaluation of Biocompatibility of Extracorporeal Circuit - Development of a Quantification Technique using in-vivo Injection of Tc99m Radioactive Platelets -)

  • 이성호;선경;최재걸;손호성;정재승;안상수;오혜정;이환성;이혜원;김광택;정윤섭;김영하;김형묵
    • Journal of Chest Surgery
    • /
    • 제35권3호
    • /
    • pp.171-176
    • /
    • 2002
  • 배경: 혈액이 이물질과 접촉을 하면 체내에서 응고 및 염증기전을 활성화 시키게 되고 임상적으로 폐 및 신장 기능의 저하, 출혈 등을 유발할 수 있고 심한 경우 다발성 장기기능 저하까지 발생할 수 있다. 이 때문에 혈액-이물질 접촉표면을 개선하는 여러 가지 시도들이 이루어지고 있고 혈액접촉표면의 적합성을 평가하는 지표의 선택은 대단히 중요하다. 접촉면의 응고기전에서 혈소판의 침착이 가장 중요한 단계이고 혈소판의 침착을 확인하기 위하여 표면흡착 정도를 비교하는 방법이 흔히 사용되고 있는데, 대부분 in-vitro 혹은ex-vivo조건에서 시행되고 있으므로 생체 내 in-vivo상황을 정확히 대변한다고 보기 힘들다. 따라서 본 연구는 in-vivo 실험조건에서 동위원소(radioisotope)를 이용하여 혈소판의 표면흡착 정도를 정량 분석하는 방법의 유용성을 분석하고자 계획되었다. 대상 및 방법: 돼지(20-25 kg, n=6)를 이용하여 하행대동맥 우회회로를 구성하였다. 우회회로는 헤파린 표면처리가 안된 일반 PVC 도관(대조군; Capiox, Terumo, Japan)과 이온결합 헤파린 표면 처리된 PVC 도관(실험군; Duraflo ll, Baxter, USA)을 Y-connector로 연결하여 2개의 회로를 동시에 구성하였다. 수술 전날 동종의 실험동물로부터 혈액을 채취하여 원심분리를 통해 고농도 혈소판 용액(platelet concentrate)을 추출하였고, 수술 당일 동위원소(Tc-99m-HMPAO, 180 $\mu$Ci)을 섞어 30분간 방치한 다음, 10분간 원심분리하여 침전층의 labeling efficiency를 측정하였다. 분리된 침전층에 혈장을 섞어(5 ml) 실험동물에 정맥주사한 후, 전신 헤파린 처치 상태에서(1 mg/kg) 하행대동맥을 차단하여 우회도관 쪽으로 2시간 동안 혈액을 순환시키고 분리하였다. 각 도관의 내강을 생리식염수 500 ml로 동시에 세척한 다음, 일정 간격으로10$\times$10 mm 크기의 절편을 5개 채취하였다. 절편을 세분하여 측정튜브에 담아 동위원소 측정기(gamma counter, Cobra II , Packard ,USA)를 이용하여 Tc-99m-HMPAO의 분당 count수를 측정함으로써 혈소판의 흡착정도를 정량분석 비교하였다. 결과: 동위원소 측정기를 이용한 평균 count수는 각각의 실험군과 대조군의 비율을 이용하여 비교하였다. 평균 count수는 대조군에서 537.3 Ci/min였고 실험군에서는 311.1Ci/min로 측정되었으며, 두 군 사이의 비율은 대조군에 비하여 실험군이 1: 0.58로 통계적으로 유의하였다.(p=0.004) 결론: 위결과를 통하여 실험군이 대조군에 비하여 혈소판 표면흡착측면에서 우수하다는 것을 정량적으로 증명할 수 있었다. 저자 등이 사용한 in-vivo 동위원소 측정법으로 혈소판 흡착정도의 생체 내 실험으로 유용하며 의료용 고분자 재료의 혈액적합성 판정의 지표로 제시하고자 한다.

조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가 (Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques)

  • 남지호;기용간;김동원;김원택
    • Radiation Oncology Journal
    • /
    • 제25권1호
    • /
    • pp.26-33
    • /
    • 2007
  • 목 적: 좌측 조기유방암으로 보존수술 후 2차원 또는 3차원 모의치료를 통해 방사선치료를 받은 환자들에서 SPECT (single photon emitted computerized tomography) 영상을 이용하여 심근관류결손의 부위와 빈도를 비교 평가하고자 하였다. 대상 및 방법: 2002년 1월부터 2003년 8월까지 AJCC 병기 T1-T2N0M0인 좌측 조기유방암으로 진단되어 외과에서 보존수술 및 화학요법 후 방사선치료를 시행하였던 32명의 환자들을 대상으로 하였다. X선 투시기를 이용한 2차원 모의치료를 통해 방사선치료를 받은 환자들과 컴퓨터단층촬영 기반의 3차원 모의치료 방법을 이용했던 환자들을 구분하여 연구를 진행하였다. 이들을 대상으로 최소 3년 이상의 추적관찰 기간 후에 technetium-99m-sestamibi gated perfusion SPECT를 시행하여 각 군에서의 심근관류결손의 부위와 빈도를 비교 평가하였고, 각 환자들에서의 심벽의 운동상태와 좌심실의 박출량을 측정하여 분석하였다. 또한 모의치료 과정에서 방사선에 피폭되는 심장영역을 각 군에서 측정하여 심근관류결손과의 상관관계를 알아보았다. 결 과: SPECT 영상 결과, 심근관류결손이 확인된 경우는 전체 32명의 환자 중 11명(34.4%)이었다. 2차원 모의치료를 받은 15명의 환자 중 7명(46.7%)에서, 3차원 모의치료를 받은 17명의 환자 중 4명(23.5%)에서 관류결손이 발견되었는데, 3차원 모의치료를 이용한 환자들에서 심근관류결손의 빈도가 통계적으로 유의하게 낮았다(p=0.0312). 심근관류결손이 확인된 11명 중, 심첨부 결손을 보인 경우가 10명으로 대부분을 차지했다. 심벽의 운동상태와 심실박출량은 모두 정상이었으며, 방사선 조사야에 포함된 심장영역은 3차원 모의치료 군에서 보다 작았으나 양군에서의 심근관류결손과의 통계적 유의성은 확인할 수 없었다. 결 론: 저자들은 이번 연구를 통해 좌측 조기유방암 환자에서 보존수술 후 방사선치료 시 전산화단층촬영 모의치료기를 이용한 3차원 모의치료 방법을 이용하면 심근에 대한 조사용적을 줄일 수 있어 심근관류결손의 빈도를 낮출 수 있음을 확인하였다. 그러나 심근관류스캔상의 결손과 향후 임상적인 허혈성 심장질환으로의 발전 또는 이로 인한 사망률의 증가와의 연관성은 장기간의 추적관찰과 전향적 임상연구를 통해 확인할 필요가 있겠다.

부하-휴식과 휴식-부하 1일 심근관류영상법의 관동맥질환 진단율 비교 (Comparison of Stress-rest and Rest-stress One Day Myocardial Perfusion Scintigraphies in Detecting Coronary Artery Diseases)

  • 범희승;민정준;송호천;김지열
    • 대한핵의학회지
    • /
    • 제31권1호
    • /
    • pp.30-35
    • /
    • 1997
  • 지금까지 부하-휴식 1일 영상법과 휴식-부하 1일 영상법의 심근관류 신티그라피 영상을 비교한 연구는 있었으나 이들의 관동맥질환의 진단율을 비교한 연구는 국내외적으로 찾아보기 힘들다. 본 연구에서는 이들 두 가지 영상법의 관동맥질환 진단율을 비교하고자 하였다. 1996년을 둘로 나누어 전반기 (1월-6월)에는 부하-휴식 1일 영상법을, 그리고 후반기 (7월-12월)에는 휴식-부하 1일 영상법을 이용하여 심근관류 SPECT를 전향적으로 시행하였고, 이 중 1개월 이내에 관동맥조영술로 관동맥질환 유무가 진단된 280명 (부하-휴식 160명, 휴식-부하 120명)을 대상으로 관동맥질환 진단율을 비교하였는데, 부하-휴식 영상법의 예민도, 특이도 및 정확도는 99%, 35%, 68%였고, 휴식-부하 영상법은 각각 96%, 47%, 78%으로 두가지 방법 간에 차이가 없었고, 각 관동맥 분지별 진단율에서도 유의한 차이가 없었다 (p>0.05). 따라서, 휴식-부하 1일 영상법과 부하-휴식 1일 영상법 중 어떤 방법을 사용하더라도 관동맥질환을 같은 진단율로 진단할 수 있을 것으로 판단되었다.

  • PDF