• Title/Summary/Keyword: Technetium

Search Result 133, Processing Time 0.025 seconds

Early-Phase SPECT/CT for Diagnosing Osteomyelitis: A Retrospective Pilot Study

  • Soo Jin Lee;Kyoung Sook Won;Hyung Jin Choi;Yun Young Choi
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.604-611
    • /
    • 2021
  • Objective: The aim of this pilot study was to investigate the potential of early-phase single-photon emission computed tomography (SPECT)/computed tomography (CT) using technetium-99m methyl diphosphonate (99mTc-MDP) for diagnosing osteomyelitis (OM). Materials and Methods: Twenty-one patients with suspected OM were enrolled retrospectively. Three-phase bone scan (TPBS), early-phase SPECT/CT (immediately after blood pool planar imaging), and delayed-phase SPECT/CT (immediately after delayed planar imaging) were performed. The final diagnoses were established through surgery or clinical follow-up for over 6 months. We compared three diagnostic criteria based on (I) TPBS alone, (II) combined TPBS and delayed-phase SPECT/CT, and (III) early-phase SPECT/CT alone. Results: OM was diagnosed in 11 of 21 patients (nine surgically and two clinically). Of the 11 OM patients, criterion-I, criterion-II, and criterion-III were positive in six, seven, and 10 patients, respectively. Of the 10 non-OM patients, criterion-I, criterion-II, and criterion-III were negative in five, five, and seven patients, respectively. The sensitivity/specificity/accuracy of criterion-I, criterion-II, and criterion-III for diagnosing OM were 54.5%/50.0%/55.0%, 63.6%/50.0%/57.1%, and 90.9%/70.0%/87.5%, respectively. Conclusion: This pilot study demonstrated the potential of using the early-phase SPECT/CT to diagnose OM. Based on the results, prospective studies with a larger sample size should be conducted to confirm the efficacy of early-phase SPECT/CT.

Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques (조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가)

  • Nam, Ji-Ho;Ki, Yong-Kan;Kim, Dong-Won;Kim, Won-Taek
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.26-33
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The aim of this study is to evaluate and compare the incidence and aspects of myocardial perfusion defects in patients who were subjected to either two-dimensional or three-dimensional simulation techniques for early left-sided breast cancer. The myocardial perfusion defects were determined from using single photon emitted computerized tomography (SPECT) myocardial perfusion images. $\underline{Materials\;and\;Methods}$: Between January 2002 and August 2003, 32 patients were enrolled in this study. The patients were diagnosed as having early (AJCC stage T1-T2N0M0) left-sided breast cancer and were treated with tangential irradiation after breast-conserving surgery and systemic chemotherapy. The patients were divided into two groups according to the type of simulation received: two-dimensional simulation using an X-ray fluoroscope simulator or three-dimensional simulation with a CT simulator. All patients underwent technetium-99m-sestamibi gated perfusion SPECT at least 3 years after radiotherapy. The incidence and area of myocardial perfusion defects were evaluated and were compared in the two groups, and at the same time left ventricular ejection fraction and cardiac wall motion were also analyzed. The cardiac volume included in the radiation fields was calculated and evaluated to check for a correlation between the amount of irradiated cardiac volume and aspects of myocardial perfusion defects. $\underline{Results}$: A myocardial perfusion defect was detected in 11 of 32 patients (34.4%). There were 7 (46.7%) perfusion defect cases in 15 patients who underwent the two-dimensional simulation technique and 4 (23.5%) patients with perfusion defects in the three-dimensional simulation group (p=0.0312). In 10 of 11 patients who had myocardial perfusion changes, the perfusion defects were observed in the cardiac apex. The left ventricular ejection fraction was within the normal range and cardiac wall motion was normal in all patients. The irradiated cardiac volume of patients in the three-dimensional simulation group was less than that of patients who received the two-dimensional simulation technique, but there was no statistical significance as compared to the incidence of perfusion defects. $\underline{Conclusion}$: Radiotherapy with a CT simulator (three-dimensional simulation technique) for early left-sided breast cancer may reduce the size of the irradiated cardiac volume and the incidence of myocardial perfusion defects. Further investigation and a longer follow-up duration are needed to analyze the relationship between myocardial perfusion defects and clinical ischemic heart disease.

A Necessity for Lumbar Puncture and VCUG in Febrile UTI Infants less than 3 Months of Age (고열을 동반한3개월 미만 요로 감염 영아에서 척추천자와 배뇨성 방광요도조영술의 필요성)

  • Kim, Ji-Hee;Lee, Jun-Ho
    • Childhood Kidney Diseases
    • /
    • v.13 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • Purpose : Our aim is to reduce the rate of lumbar spinal tapping and voiding cystourethrography (VCUG) in febrile urinary tract infection (UTI) infants less than 3 months of age. Methods : We reviewed the prevalence of UTI, sepsis, meningitis and UTI with bacterial meningitis in febrile infants less than 3 months of age during the period from Jan. 2001 to Jun. 2008. Renal ultrasonography, Technetium-99m dimercaptosuccinic acid (DMSA) renal scan or VCUG were performed in infants with UTI. Infants with UTI were divided into two groups according to the presence of abnormal findings of ultrasonography and DMSA renal scan : group 1-Infants in whom both ultrasonography and DMSA were normal, group 2-Infants in whom ultrasonography or DMSA were abnormal. Prevalence of VUR was compared between the two groups. We followed up the clinical course of patients who had VUR in group 1. Results : Among 1962 Infants, UTI, sepsis and bacterial meningitis were diagnosed in 620 (31.6%), 63 (3.2%), 8 (0.4%) respectively. Lumbar puncture was performed in 413 (66.6%) infants with UTI and we did not detect a case of bacterial meningitis in association. 348 infants with proven UTI were undergone ultrasonography, DMSA, VCUG. In group 1 with 110 infants (31.6%), the presence of VUR was 4 (3.6%). In group 2 with 238 infants (68.4%), the presence of VUR was 51 (21.4%). Abnormal findings of ultrasonography or DMSA renal scan were closely related with high grade VUR. Most of patients with VUR in group1 had good prognosis. Conclusion : Lumbar puncture and VCUG are invasive procedures. Therefore we should decide whether to perform lumbar puncture or VCUG in infants less than 3 months. of age with their first febrile UTI.

Glomerular Filtration Rate Measurements Using $^{99m}$Technetium-mercaptoacetyltriglycine Dynamic Renal Scintigraphy in Children with Renal Disease (신장 질환이 있는 소아에서 $^{99m}$Technetium-mercaptoacetyltriglycine ($^{99m}Tc$-MAG3) 신장 스캔에 의한 사구체 여과율 측정)

  • Yoon, In Ae;Yun, Ki Wook;Lim, In Seok;Choi, Eung Sang;Yoo, Byung Hun
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.57-64
    • /
    • 2013
  • Purpose: In children, 24-hour urine collections are unreliable for evaluating glomerular filtration rate (GFR) because of the difficulty of regulating voiding and the daily variation of urinary creatinine up to 25%. Additionally, creatinine clearance (Ccr) based on urinary creatinine is considered inaccurate. The purpose of this study was to compare estimated GFR determined using Ccr, formulas with serum cystatin C and creatinine, and $^{99m}Tc$-mercaptoacetyltriglycine (MAG3) dynamic renal scintigraphy. Methods: This retrospective study included 101 patients (age, <18 years) who visited Chung-Ang University Hospital between July 2011 and August 2012. GFR was estimated using 24-hour urinary creatinine, five formulas with serum creatinine and cystatin C, and $^{99m}Tc$-MAG3 renal scan. Results: Of the 101 patients, glomerular renal diseases were present in 60 patients (59.4%) and non-glomerular diseases were present in 41 patients (40.6%). There was a significant correlation between estimated GFR determined using $^{99m}Tc$-MAG3 renal scan and Ccr (r=0.389, P <0.001). The correlation values between estimated GFR determined using $^{99m}Tc$-MAG3 renal scan and each formula of Schwartz, Counahan-Barratt, Cockcroft-Gault, Filler and Lepage, and Bokencamp were 0.265 (P=0.007), 0.128 (P=0.044), 0.230 (P=0.021), 0.356 (P<0.001), and 0.355 (P <0.001), respectively. $^{99m}Tc$-MAG3 renal scan was correlated with estimated-GFR by all formulas in decreased renal function. Conclusion: Estimated GFRs determined using serum creatinine and cystatin C, and $^{99m}Tc$-MAG3 renal scan correlated well with estimated GFR determined using Ccr. $^{99m}Tc$-MAG3 renal scan may be replaced for evaluation of renal function with convenience in patients with renal disease and decreased renal function in childhood.

Different Uptake of Tc-99m ECD and Tc-99m HMPAO in the Normal Brains: Analysis by Statistical Parametric Mapping (정상 뇌 혈류 영상에서 방사성의약품에 따라 혈류 분포에 차이가 있는가: 통계적 파라미터 지도를 사용한 분석)

  • Kim, Euy-Neyng;Jung, Yong-An;Sohn, Hyung-Sun;Kim, Sung-Hoon;Yoo, Ie-Ryung;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.244-254
    • /
    • 2002
  • Purpose: This study investigated the differences between technetium-99m ethyl cysteinate dimer (Tc-99m ECD) and technetium-99m hexamethylpropylene amine oxime (Tc-99m HMPAO) uptake in the normal brain by means of statistical parametric mapping (SPM) analysis. Materials and Methods: We retrospectively analyzed age and sex matched 53 cases of normal brain SPECT. Thirty-two cases were obtained with Tc-99m ECD and 21 cases with Tc-99m HMPAO. There were no abnormal findings on brain MRIs. All of the SPECT images were spatially transformed to standard space, smoothed and globally normalized. The differences between the Tc-99m ECD and Tc-99m HMPAO SPECT images were statistically analyzed using statistical parametric mapping (SPM'99) software. The differences bgetween the two groups were considered significant ant a threshold of corrected P values less than 0.05. Results: SPM analysis revealed significantly different uptakes of Tc-99m ECD and Tc-99m HMPAO in the normal brains. On the Tc-99m ECD SPECT images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the basal ganglia and thalamus, and in the superior region of the cerebellum. On the Tc-99m HMPAO SPECT images, relatively higher uptakes was observed in subcortical areas of the frontal region, temporal lobe, and posterior portion of inferior cerebellum. Conclusion: Uptake of Tc-99m ECD and Tc-99m HMPO in the normallooking brain was significantly different on SPM analysis. The selective use of Tc-99m ECD of Tc-99m HMPAO in brain SPECT imaging appears especially valuable for the interpretation of cerebral perfusion. Further investigation is necessary to determine which tracer is more accurate for diagnosing different clinical conditions.

Ictal single-photon emission computed tomography with slow dye injection for determining primary epileptic foci in infantile spasms (영아연축에서 추적자의 느린 점적주사를 이용한 발작기 SPECT)

  • Hur, Yun Jung;Lee, Joon Soo;Kang, Hoon Chul;Park, Hye Jung;Yun, Mi Jin;Kim, Heung Dong
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.7
    • /
    • pp.804-810
    • /
    • 2009
  • Purpose : We investigated whether ictal single-photon emission computed tomography (SPECT) with prolonged injection of technetium-99m (99mTc) ethyl cysteinate dimer during repeated spasms can localize the epileptogenic foci in children with infantile spasms. Methods : Fourteen children with infantile spasms (11 boys, 3 girls; mean age, $2.2{\pm}1.3$ years) were examined. When a cluster of spasms was detected during video electroencephalography (EEG) monitoring, $^{99m}Tc$ ethyl cysteinate dimer was slowly and continuously injected for 2 minutes to determine the presence of ictal SPECT. For 7 children, the ictal and interictal SPECT images were visually analyzed, while for the remaining 7 children, the SPECT images were analyzed using the subtraction ictal SPECT coregistered to magnetic resonance imaging (MRI) (SISCOM) technique. Subsequently, we analyzed the association between the ictal SPECT findings and those of other diagnostic modalities such as EEG, MRI, and positron emission tomography (PET). Results : Increase in cerebral blood flow on ictal SPECT involved the epileptogenic foci in 10 cases6 cases analyzed by visual assessment and 4 analyzed by the SISCOM technique. The ictal SPECT and video-EEG findings showed moderate agreement (Kappa=0.57; 95% confidence interval, 0.18-0.96). Conclusion : Ictal SPECT with prolonged injection of a tracer could provide supplementary information to localize the epileptogenic foci in infantile spasms.

Synthesis Characterization and Biodistribution of $^{99m}Tc$-Ethyl-3-Isocyanobutyrate as a New Myocardial Perfusion Agent (새로운 심관관류 영상 화합물로서 $^{99m}Tc$-Ethyl-3-Isocyano-butyrate의 합성, 표지 및 체내동태에 대한 연구)

  • Lee, Myung-Chul;Cho, Jung-Hyuck;Lee, Dong-Soo;Lim, Sang-Moo;Oh, Seung-Joon;Chung, Soo-Wook;Lee, Kyung-Han;Jeong, Jae-Min;Chung, June-Key;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.223-232
    • /
    • 1993
  • Technetium labeled isonitrile analogues are widely used as myocardial perfusion imaging agents. We synthesized and characterized a new isonitrile compound, ethyl 3-isocyanobutyrate(EIB). Proton and $^{13}C$ NMR spectroscopy and thin layer chromatography with a $C_{18}$ coat was performed. EIB was easily labeled with $^{99m}TcO_4^-$- with sodium dithionite. The labeling efficiency measured by RP-HPLC was over 95%. The labeled product was stable with dilution in normal saline and with prolonged incubation at room temperature. There was no formation of secondary products or free $^{99m}TcO_4^-$. In vivo kinetics study of $^{99m}Tc$ (I) labeled EIB in rabbits showed adequate myocardial uptake, good contrast against lung background, and relatively rapid liver clearance. The heart to lung ratio was over 2.5 and the heart to liver ratio was approximately from 0.4 to 5 at 60 minutes post injection. Hepatic clearance of $^{99m}Tc-MIBI$ was faster ($t_{1/2}$=6 minutes) than that of $^{99m}Tc-MIBI$. In vivo kinetics observed in dog was similar to that in rabbit but there was faster gallbladder filling, and thus lower liver background. SPECT imaging of the canine myocardium showed favorable imaging characteristics. However, biodistribution in mice demonstrated a myocardial % injected dose/organ of less than 0.1%. This was thought to be due to interspecies difference in plasma esterase activity. In human plasma, $^{99m}Tc$ ( I ) labeled EIB was stable for at least 2 hours, without production of secondary products by HPLC. We conclude that ethyl 3-isocyanobutyrate may be a potential new myocardial perfusion imaging agent and deserves further investigation as to its usefulness for clinical use.

  • PDF

Evaluation of Reductive Effect of Exposure Dose by Using Air Gap Apron in Nuclear Medicine Related Work Environment (핵의학과 내 작업 환경에서 공기층 납치마의 피폭선량 감소 효과 평가)

  • Lee, Wang-Hui;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.12
    • /
    • pp.845-853
    • /
    • 2014
  • In this study, we measured the dose reaching the OSLD dosimeter by using the regular lead apron, and air gap apron through 3 experiments, and researched the reductive effect of air gap apron on exposure dose based on the 140 keV gamma ray radiating from $^{99m}technetium$, which is the most commonly used in nuclear medicine. As a result, when the gap between the dosimeter and 0.2mm lead plate is 0 Cm, the average value of 10 dosimeters was 0.515 mSv, and when the gap between the dosimeter and lead plate is 20 Cm, the average value of 10 dosimeters was 0.138 mSv, which shows reductive effect of dose as much as 0.388 mSv. When the gap between the dosimeter and 0.5mm lead plate is 0 Cm, the average value of 10 dosimeters was 0.296 mSv, and when the gap between the dosimeter and lead plate is 20 Cm, the average value of 10 dosimeters was 0.075 mSv, which shows reductive effect of dose as much as 0.221 mSv. As we check the cumulative dosage for 3 days, the lead apron without air layer shows average 0.239 mSv, and the air gap apron shows 0.176 mSv, which is actually reduced by 0.062 mSv. As we check the cumulative dosage for a month, the lead apron without air layer shows 0.59 mSv, and the air gap apron shows 0.54 mSv, which is reduced by 0.05 mSv.

Lower Incidence but More Aggressive Behavior of Right Sided Breast Cancer in Pakistani Women: Does Right Deserve More Respect?

  • Fatima, Nosheen;Zaman, Maseeh Uz;Maqbool, Aamir;Khan, Shaista H.;Riaz, Nazia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.43-45
    • /
    • 2013
  • Background: The aim of this epidemiological study was to establish the laterality of breast cancer (BC) and its association with size, receptor status of the primary tumor and bone metastasis (BM) in a local population. Materials and Methods: This retrospective study included cases of BC from Jan-2009 to Dec-2011 who were referred for metastatic work up or follow up survey with Technetium-99m MDP bone scan (BS) to the Nuclear Medicine Department of Karachi Institute of Radiotherapy and Nuclear Medicine (KIRAN). A total of 384 patients out of 521 were included and all reviewed for age, primary tumor size (PTS), laterality, receptor status like estrogen receptor (ER) progesterone receptor (PR) and Her-2-Neu receptor, presence or absence of BM with sites of involvement and time interval between diagnosis of BC and appearance of BM. Results: The left to right sided BC proportion was significantly higher than unity (59%:41%; p<0.001). The right sided BC was observed in younger age group (46:52 years; p<0.0001) and with a smaller PTS than the left sided (3.43:4.15 cm; p<0.0001). The patients with BM had relatively higher negative receptor status with a significant predominance of right sided BC. The overall incidence of BM on BS was 28% and relatively higher in right than left breast (33%:24% p=0.068). The average number of BM sites was also significantly greater for the right side (6:4, P<0.0001). The % cumulative risk of BM in right breast was noted at significantly smaller PTS than left side with log rank value of 5.579; p<0.05. The Kaplan Meier survival plot for event free survival of BM in left sided BC was significantly higher than for the right side (log rank value=4.155, p<0.05), with an earlier appearance of BM in right BC. Conclusions: 1) A left sided predominance of BC was seen in local population; 2) right sided BC had a more aggressive behavior with extensive and earlier appearance of BM at relatively younger age, smaller PTS and receptor (s) negativity.

PRELIMINARY STUDY OF BRAIN SPECT IN CHILDREN WITH PERVASIVE DEVELOPMENTAL DISORDER OR DEVELOPMENTAL LANGUAGE DISORDER (전반적발달장애 아동 및 발달성언어장애 아동의 뇌 단일광자방출전산화단층촬영 소견에 대한 예비연구)

  • Shin, Yee-Jin;Ryu, Young-Hoon;Yook, Ki-Hwan;Noh, Kyung S;Song, Dong-Ho;Lee, Ho-Bun
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.8 no.2
    • /
    • pp.256-265
    • /
    • 1997
  • Objectives:The purpose of this study was to investigate the characteristics and differences of brain function in pervasive developmental disorder and developmental language disorder. Method:The subjects were composed of 14 cases of pervasive developmental disorder and 13 cases developmental language disorder. They were investigated by technitium-99m-EDC SPECT. All SPECT were visually assessed by two nuclear medicine specialists, and then quantified by region of interest including temporal, parietal cortex, thalamus, basal ganglia and cerebellum. Result:In both groups, cerebral blood flow was decreased in the temporal, parietal cortex, basal ganglia, thalamus, cerebellum by visual assessment. There was no significant difference between the 2 groups by quantitative and qualitative assessment. Conclusion:These results suggest that pervasive developmental disorder and developmental language disorder are caused by defects in the interneural connection and that both disorders are spectrum disorders.

  • PDF